Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Haixin Ke is active.

Publication


Featured researches published by Haixin Ke.


Scientific Reports | 2015

Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection in Patients with Breast Cancer

Alejandro Garcia-Uribe; Todd N. Erpelding; Arie Krumholz; Haixin Ke; Konstantin Maslov; Catherine M. Appleton; Julie A. Margenthaler; Lihong V. Wang

The detection of regional lymph node metastases is important in cancer staging as it guides the prognosis of the patient and the strategy for treatment. Sentinel lymph node biopsy (SLNB) is an accurate, less invasive alternative to axillary lymph node dissection. The sentinel lymph node hypothesis states that the pathological status of the axilla can be accurately predicted by determining the status of the first lymph nodes that drain from the primary tumor. Physicians use radio-labeled sulfur colloid and/or methylene blue dye to identify the SLN, which is most likely to contain metastatic cancer cells. However, the surgical procedure causes morbidity and associated expenses. To overcome these limitations, we developed a dual-modality photoacoustic and ultrasonic imaging system to noninvasively detect SLNs based on the accumulation of methylene blue dye. Ultimately, we aim to guide percutaneous needle biopsies and provide a minimally invasive method for axillary staging of breast cancer.


Journal of Biomedical Optics | 2012

Performance characterization of an integrated ultrasound, photoacoustic, and thermoacoustic imaging system

Haixin Ke; Todd N. Erpelding; Ladislav Jankovic; Changjun Liu; Lihong V. Wang

We developed a novel trimodality system for human breast imaging by integrating photoacoustic (PA) and thermoacoustic (TA) imaging techniques into a modified commercial ultrasound scanner. Because light was delivered with an optical assembly placed within the microwave antenna, no mechanical switching between the microwave and laser sources was needed. Laser and microwave excitation pulses were interleaved to enable PA and TA data acquisition in parallel at a rate of 10 frames per second. A tube (7 mm inner diameter) filled with oxygenated bovine blood or 30 mM methylene blue dye was successfully detected in PA images in chicken breast tissue at depths of 6.6 and 8.4 cm, respectively, for the first time. The SNRs at these depths reached ∼24 and ∼15 dB, respectively, by averaging 200 signal acquisitions. Similarly, a tube (13 mm inner diameter) filled with saline solution (0.9%) at a depth of 4.4 cm in porcine fat tissue was successfully detected in TA images. The PA axial, lateral, and elevational resolutions were 640 μm, 720 μm, and 3.5 mm, respectively, suitable for breast cancer imaging. A PA noise-equivalent sensitivity to methylene blue solution of 260 nM was achieved in chicken tissue at a depth of 3.4 cm.


Optics Letters | 2013

Absolute photoacoustic thermometry in deep tissue.

Junjie Yao; Haixin Ke; Stephen Tai; Yong Zhou; Lihong V. Wang

Photoacoustic thermography is a promising tool for temperature measurement in deep tissue. Here we propose an absolute temperature measurement method based on the dual temperature dependences of the Grüneisen parameter and the speed of sound in tissue. By taking ratiometric measurements at two adjacent temperatures, we can eliminate the factors that are temperature irrelevant but difficult to correct for in deep tissue. To validate our method, absolute temperatures of blood-filled tubes embedded ~9 mm deep in chicken tissue were measured in a biologically relevant range from 28°C to 46°C. The temperature measurement accuracy was ~0.6°C. The results suggest that our method can be potentially used for absolute temperature monitoring in deep tissue during thermotherapy.


Journal of Biomedical Optics | 2013

Single-cell photoacoustic thermometry

Liang Gao; Lidai Wang; Chiye Li; Yan Liu; Haixin Ke; Chi Zhang; Lihong V. Wang

Abstract. A novel photoacoustic thermometric method is presented for simultaneously imaging cells and sensing their temperature. With three-seconds-per-frame imaging speed, a temperature resolution of 0.2°C was achieved in a photo-thermal cell heating experiment. Compared to other approaches, the photoacoustic thermometric method has the advantage of not requiring custom-developed temperature-sensitive biosensors. This feature should facilitate the conversion of single-cell thermometry into a routine lab tool and make it accessible to a much broader biological research community.


Journal of Biomedical Optics | 2014

Photoacoustic thermography of tissue

Haixin Ke; Stephen Tai; Lihong V. Wang

Abstract. Photoacoustic (PA) techniques can measure temperature in biological tissues because PA signal amplitude is sensitive to tissue temperature. So far, temperature-measuring PA techniques have focused on sensing of temperature changes at a single position. In this work, we photoacoustically measured spatial distribution of temperature in deep tissue. By monitoring the temperature at a single position using a thermocouple, the relationship between the PA signal amplitude and the actual temperature was determined. The relationship was then used to translate a PA image into a temperature map. This study showed that it is possible to calibrate the system for the temperature range of hyperthermia using single-point measurements over a smaller temperature range. Our experimental results showed a precision of −0.8±0.4°C (mean±standard error) in temperature measurement, and a spatial resolution as fine as 1.0 mm. PA techniques can be potentially applied to monitor temperature distribution deep in tissue during hyperthermia treatment of cancer.


Proceedings of SPIE | 2014

A Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection: Preliminary Clinical Results

Todd N. Erpelding; Alejandro Garcia-Uribe; Arie Krumholz; Haixin Ke; Konstantin Maslov; Catherine M. Appleton; Julie A. Margenthaler; Lihong V. Wang

Sentinel lymph node biopsy (SLNB) has emerged as an accurate, less invasive alternative to axillary lymph node dissection, and it has rapidly become the standard of care for patients with clinically node-negative breast cancer. The sentinel lymph node (SLN) hypothesis states that the pathological status of the axilla can be accurately predicted by determining the status of the first (i.e., sentinel) lymph nodes that drain from the primary tumor. Physicians use radio-labeled sulfur colloid and/or methylene blue dye to identify the SLN, which is most likely to contain metastatic cancer cells. However, the surgical procedure causes morbidity and associated expenses. To overcome these limitations, we developed a dual-modality photoacoustic and ultrasound imaging system to noninvasively detect SLNs based on the accumulation of methylene blue dye. Ultimately, we aim to guide percutaneous needle biopsies and provide a minimally invasive method for axillary staging of breast cancer. The system consists of a tunable dye laser pumped by a Nd:YAG laser, a commercial ultrasound imaging system (Philips iU22), and a multichannel data acquisition system which displays co-registered photoacoustic and ultrasound images in real-time. Our clinical results demonstrate that real-time photoacoustic imaging can provide sensitive and specific detection of methylene blue dye in vivo. While preliminary studies have shown that in vivo detection of SLNs by using co-registered photoacoustic and ultrasound imaging is feasible, further investigation is needed to demonstrate robust SLN detection.


Proceedings of SPIE | 2012

Temperature mapping using photoacoustic and thermoacoustic tomography

Haixin Ke; Todd N. Erpelding; Ladislav Jankovic; Lihong V. Wang

Photoacoustic (PA) and thermoacoustic (TA) effects are based on the generation of acoustic waves after tissues absorb electromagnetic energy. The amplitude of the acoustic signal is related to the temperature of the absorbing target tissue. A combined photoacoustic and thermoacoustic imaging system built around a modified commercial ultrasound scanner was used to obtain an image of the targets temperature, using reconstructed photoacoustic or thermoacoustic images. To demonstrate these techniques, we used photoacoustic imaging to monitor the temperature changes of methylene blue solution buried at a depth of 1.5 cm in chicken breast tissue from 12 to 42 °C. We also used thermoacoustic imaging to monitor the temperature changes of porcine muscle embedded in 2 cm porcine fat from 14 to 28 °C. The results demonstrate that these techniques can provide noninvasive real-time temperature monitoring of embedded objects and tissue.


Proceedings of SPIE | 2011

Photoacoustic and thermoacoustic tomography of dog prostates

Haixin Ke; Zijian Guo; Todd N. Erpelding; Ladislav Jankovic; Robert L. Grubb; Lihong V. Wang

We developed a tri-modal system combining photoacoustic (PA) tomography, thermoacoustic (TA) tomography, and ultrasound (US) imaging. Acquired images of an excised dog prostate were compared to histology results. All three modalities can image distinct features. Features like the urethra were shown in both TA and US images, but TA gave a higher contrast-to-noise ratio. Fibrous tissue was more clearly imaged by TA, while the duct structure was better shown in PA images. These experimental results demonstrate the potential advantages of our tri-modal imaging system.


Proceedings of SPIE | 2014

Noninvasive measurement of internal jugular venous oxygen saturation by photoacoustic imaging

Alejandro Garcia-Uribe; Todd N. Erpelding; Haixin Ke; Kavya Reddy; Anshuman Sharma; Lihong V. Wang

The metabolic rate and oxygen consumption of the brain is reflected in jugular venous oxygen saturation. In many clinical conditions, such as head trauma, stroke, and low cardiac output states, the brain is at risk for hypoxic-ischemic injury. The current gold standard for monitoring brain oxygenation is invasive and requires jugular vein catheterization under fluoroscopic guidance; and therefore it is rarely used. Photo-acoustic tomography in combination with ultrasound can be used to estimate oxygen saturation of the internal jugular vein in real-time. This noninvasive method will enable earlier detection and prevention of impending hypoxic brain injury. A wavelength-tunable dye laser pumped by a Nd:YAG laser delivers light through an optical fiber bundle, and a modified commercial ultrasound imaging system (Philips iU22) detects both the pulse-echo ultrasound (US) and photoacoustic (PA) signals. A custom-built multichannel data acquisition system renders co-registered ultrasound and photoacoustic images at 5 frames per second. After the jugular vein was localized in healthy volunteers, dualwavelength PA images were used to calculate the blood hemoglobin oxygen saturation from the internal jugular vein in vivo. The preliminary results raise confidence that this emerging technology can be used clinically as an accurate, noninvasive indicator of cerebral oxygenation.


Proceedings of SPIE | 2014

Co-registered spectral photoacoustic tomography and ultrasonography of breast cancer

Haixin Ke; Todd N. Erpelding; Alejandro Garcia-Uribe; Eileen Jacobs; Susan O. Holley; Barbara Monsees; Lihong V. Wang

Many breast cancer patients receive neoadjuvant treatment to reduce tumor size and enable breast conserving therapy. Most imaging methods used to monitor response to neoadjuvant chemotherapy or hormone therapy depend on overall gross tumor morphology and size measurements, which may not be sensitive or specific, despite tumor response on a cellular level. A more sensitive and specific method of detecting response to therapy might allow earlier adjustments in treatment, and thus result in better outcomes while avoiding unnecessary morbidity. We developed an imaging system that combines spectral photoacoustic tomography and ultrasonography to predict breast neoadjuvant therapeutic response based on blood volume and blood oxygenation contrast. The system consists of a tunable dye laser pumped by a Nd:YAG laser, a commercial ultrasound imaging system (Philips iU22), and a multichannel data acquisition system which displays co-registered photoacoustic and ultrasound images in real time. Early studies demonstrate functional imaging capabilities, such as oxygen saturation and total concentration of hemoglobin, in addition to ultrasonography of tumor morphology. Further study is needed to determine if the co-registered photoacoustic tomography and ultrasonography system may provide an accurate tool to assess treatment efficacy by monitoring tumor response in vivo.

Collaboration


Dive into the Haixin Ke's collaboration.

Top Co-Authors

Avatar

Lihong V. Wang

California Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Alejandro Garcia-Uribe

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Arie Krumholz

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Catherine M. Appleton

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Julie A. Margenthaler

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Konstantin Maslov

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Stephen Tai

Washington University in St. Louis

View shared research outputs
Top Co-Authors

Avatar

Anshuman Sharma

Washington University in St. Louis

View shared research outputs
Researchain Logo
Decentralizing Knowledge