Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hal T. Butler is active.

Publication


Featured researches published by Hal T. Butler.


Journal of Chromatography A | 1984

Survey of organic molten salt phases for gas chromatography

Colin F. Poole; Hal T. Butler; Myra E. Coddens; Subhash C. Dhanesar; Frank. Pacholec

Abstract The organic molten salts tetra- n- hexylammonium benzoate, tetra- n- heptylammonium chloride, 1-methyl-3-ethylimidazolium chloride, ethylpyridinium bromide, tri- n- butylbenzylphosphonium chloride, tetra- n- butylammonium tetrafluoroborate, and sodium isovalerate are evaluated as stationary phases for gas chromatography. They all behave as stable isotropic liquids over a temperature range of at least 50°C, and in most cases, greater than 100°C. As a series these salts provide a range of liquid phases spanning temperatures from room temperature to ca . 290°C. The principal solute-retaining forces are orientation and proton donor interactions, the magnitude of which depends on the identity of the salt. The physical and chemical properties of the organic molten salts are compatible with their use in gas chromatography to separate a wide range of sample types including alcohols, halocarbon compounds, substituted benzene and naphthalene derivatives, and essential oils. Calcium nitrate tetrahydrate is also evaluated as an example of a hydrated melt. Excessive retention of polar solutes and poor peak shape make its general use impractical.


Journal of Liquid Chromatography & Related Technologies | 1985

Some quantitative aspects of scanning densitometry in high-performance liquid chromatography

Colin F. Poole; Myra E. Coddens; Hal T. Butler; S. A. Schuette; S. S. J. Ho; S. Khatib; L. Piet; K. K. Brown

Abstract The optimization of instrumental parameters that influence resolution and signal-to-noise ratios in the recording of thinlayer chromatograms by scanning densitometry are discussed. A standardized method of determining sensitivity and detectability is proposed and used to evaluate the performance of a Shimadzu CS-910 scanning densitometer. Fluorescence enhancement reagents are discussed as a method of improving sample detectability in the fluorescence mode. The influence of the sorbent medium on both the position and intensity of the fluorescence emission signal is discussed.


Journal of Chromatography A | 1984

Qualitative identification of polycyclic aromatic hydrocarbons by high-performance thin-layer chromatography and fluorescence scanning densitometry

Hal T. Butler; Myra E. Coddens; Colin F. Poole

Abstract A procedure is described for the accurate measurement of emission response ratios for polycyclic aromtic hydrocarbons using fluorescence scanning densitometry and reversed-phase high-performance thin-layer chromatography. By optimizing instrumental conditions and using perylene as a reference standard, the emission response ratios can be reproduced to better than 3% relative standard deviation on a day-to-day basis. The emission response ratios enable the optimum detection conditions for sensitivity or selectivity to be easily identified. The normalized emission response ratios can be used to improve the confidence in the identification of a particular compound made by coincidence of retention in the chromatographic system. The method has been applied to the identification of polycyclic aromatic hydrocarbons in samples of laboratory dust and a diesel engine exhaust particulate sample.


Journal of Chromatography A | 1983

Characterization of a scanning densitometer for high-performance thin-layer chromatography

Hal T. Butler; Sheila A. Schuette; Frank. Pacholec; Colin F. Poole

Abstract Optimum conditions to maximize the observed resolution and signal-to-noise ratio of the Shimadzu CS-910 scanning densitometer for high-performance thin-layer chromatography (HPTLC) are described. Resolution is shown to depend only on the slit width and is constant for slit widths in the range 0.05–0.80 mm. Signal-to-noise ratios depend on the size of the sampling beam which is fixed by the dimensions of the slit. At small slit dimensions the noise component dominates the signal-to-noise ratio. For scanning HPTLC plates dual-beam single-wavelength operation, linear scanning, scan speeds of 24 or 48 mm min −1 , slit widths of 0.5–0.8 mm and slit height ≈ 3.0 mm are recommended for general use.


Journal of Chromatography A | 1984

Comparison of methods for separating polycyclic aromatic hydrocarbons by high-performance thin-layer chromatography

Colin F. Poole; Hal T. Butler; Myra E. Coddens; Salwa Khatib; Rene VanDervennet

A comparison is made of different stationary phases (silica gel, cellulose, acetylated cellulose, and 3-aminopropyl-, ethyl-, octyl-, octadecyl-, and diphenylsilanized silica gel), mobile phases, and development techniques (conventional, continuous, and multiple) for the separation of environmentally important polycyclic aromatic hydrocarbons by high-performance thin-layer chromatography. Reversed-phase separations using octadecylsilanized silica gel and methanol-water or methanol-water-based ternary solvent systems were found to give the best separations. A new development technique, multiple development with application of the mobile phase further up the plate at each successive development, provided superior resolution of the polycyclic aromatic hydrocarbons compared with conventional multiple development.


Journal of Chromatography A | 1983

Mode selection and optimization of parameters for recording high-performance thin-layer chromatograms by transmission measurements

Myra E. Coddens; Salwa Khatib; Hal T. Butler; Colin F. Poole

Abstract Optimum conditions to maximize the observed resolution and signal-to-noise ratio of a scanning densitometer for high-performance thin-layer chromatography are described. Transmission measurements are compared in three operating modes; two being pseudo dual-beam methods and the third a dual-wavelength single-beam mode. In all modes resolution is shown to be independent of those parameters which control the dimensions of the measuring beam within their accessible ranges. Signal-to-noise ratios depend on both the operating mode and the dimensions of the measuring beam. In particular, signal shows a marked dependence on the ratio of slit height to spot diameter. Similar values for resolution and better signal-to-noise characteristics may be obtained in the transmission mode compared to reflectance for substances absorbing in the visible range.


Journal of Chromatography A | 1981

Evaluation of substituted polyphenyl ethers as polar phases in gas chromatography

Colin F. Poole; Hal T. Butler; S.A. Agnello; W.-F. Sye; A. Zlatkis; G. Holzer

Abstract Five- and six-ring meta -linked polyphenyl ethers containing NO 2 , Br, CH 3 CO, CH 2 Cl and CN sustituent groups have been prepared. The reaction conditions result in the formation of isomeric mixtures which can be analyzed by reversed-phase high-performance liquid chromatography. Although these substances are not suitable as starting materials for the synthesis of thermally stable reference stationary phases with a defined chemical structure, they do have useful stationary phase properties in their own right. The cyanopolyphenyl ethers (SPE-15 and SPE-16) have similar polarity to Carbowax 20M and Silar 5CP and are more thermally stable. They have good chromatographic properties and can be used to prepare high efficiency packed or capillary columns.


Archive | 1986

Instrumental Evaluation of Thin-Layer Chromatograms

Colin F. Poole; Hal T. Butler; Myra E. Coddens; Sheila A. Schuette

Recent changes in the practice of thin-layer chromatography (TLC) have created a renaissance of interest in this technique and led to its wider acceptance as a powerful tool for qualitative and quantitative analysis of mixtures. The performance breakthrough in TLC, referred to as high performance thin-layer chromatography (HPTLC), was not a result of any specific advances in instrumentation or materials, but was rather a culmination of improvements in practically all of the operations comprising TLC, [1–6]. Improvements in the quality of the sorbent layer, methods of sample application, new development techniques, and the availability of scanning densitometers for in situ quantitative analysis were all important developments in the evolution of HPTLC. The new HPTLC plates were prepared from sorbents of smaller average particle diameter and of narrower particle size distribution than those used to prepare conventional TLC plates. The performance of these plates improved an order of magnitude over those used for conventional TLC. Because of the lower sample capacity of the HPTLC sorbent layer, the amount of sample applied to it had to be scaled down from those commonly used in conventional TLC. Typical sample volumes applied to the plates are in the range 100–200 nl, sample amounts less than ca. 0.1 μg, and starting spot sizes of 1.0–2.0 mm.


Analytical Chemistry | 1982

Molten organic salt phase for gas-liquid chromatography

Frank. Pacholec; Hal T. Butler; Colin F. Poole


Journal of Chromatography A | 1983

Fluorescence enhancement of polycyclic aromatic hydrocarbons separated on silica gel high-performance thin-layer chromatography plates

Shaun S.J. Ho; Hal T. Butler; Colin F. Poole

Collaboration


Dive into the Hal T. Butler's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

G. Holzer

Colorado School of Mines

View shared research outputs
Top Co-Authors

Avatar

K. K. Brown

Wayne State University

View shared research outputs
Top Co-Authors

Avatar

L. Piet

Wayne State University

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge