Hani F. Ounsi
Lebanese University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Hani F. Ounsi.
Dental Materials | 2009
Moustafa N. Aboushelib; Hesam Mirmohamadi; Jukka Pekka Matinlinna; Edwin Kukk; Hani F. Ounsi; Ziad Salameh
OBJECTIVES The zirconia-resin bond strength was enhanced using novel engineered zirconia primers in combination with selective infiltration etching as a surface pre-treatment. The aim of this study was to evaluate the effect of artificial aging on the chemical stability of the established bond and to understand the activation mechanism of the used primers. METHODS Selective infiltration etched zirconia discs (Procera; NobelBiocare) were coated with one of four novel engineered zirconia primers containing reactive monomers and were bonded to resin-composite discs (Panavia F2.0). Fourier transform infrared spectroscopy (FT-IR) was carried out to examine the chemical activation of zirconia primers from mixing time and up to 60min. The bilayered specimens were cut into microbars (1mm(2) in cross-section area) and zirconia-resin microtensile bond strength (MTBS) was evaluated immediately and after 90 days of water storage at 37 degrees C. Scanning electron microscopy (SEM) was used to analyze the fracture surface. RESULTS There was a significant drop in MTBS values after 90 days of water storage for all tested zirconia primers from ca. 28-41MPa to ca. 15-18MPa after completion of artificial aging. SEM revealed increase in percentage of interfacial failure after water storage. FTIR spectra suggested adequate activation of the experimental zirconia primers within 1h of mixing time. SIGNIFICANCE The novel engineered zirconia primers produced initially high bond strength values which were significantly reduced after water storage. Long-term bond stability requires developing more stable primers.
Journal of Endodontics | 1999
Gaby Haddad; Walid Nehme; Hani F. Ounsi
C-shaped canals are mostly found in mandibular second molars. Studies have shown that frequency ranges from 2.7 to 31%. This study was undertaken to provide further knowledge of the distribution of such canal anatomy, by determining the frequency of C-shaped canals in a sample representing the Lebanese population. Ninety-four mandibular second molars with scheduled endodontic treatment were examined over a 1-yr period. Of the 94 treated molars, 18 exhibited C-shaped canals that would represent 19.1% of the sample. The geographical position of Lebanon could represent an explanation for this phenomenon.
Journal of Endodontics | 2008
Ziad Salameh; Roberto Sorrentino; Hani F. Ounsi; Walid Sadig; Fadi Atiyeh; Marco Ferrari
The aim of this study was to compare the fracture resistance and failure pattern of endodontically treated maxillary incisors restored using composite resin with or without fiber-reinforced composite (FRC) posts under different types of full-coverage crowns. The null hypothesis tested was that fracture resistance and the failure pattern of these teeth were not affected by the use of FRC posts or by the type of full-coverage crown. One hundred twenty maxillary incisors were endodontically treated and divided into 4 groups of 30 each. Each group was divided into two subgroups: restoration with or without fiber post. PFM crowns were placed in group 1, Empress II crowns in group 2, SR Adoro crowns in group 3, and Cercon crowns in group 4. Fracture tests were performed by loading specimens to fracture. Data were analyzed with two-way analysis of variance (alpha = 0.05). The type of crown was not a significant factor affecting fracture resistance (p = 0.4), whereas the presence of a post was (p = 0.001). Both the presence of post and the type of crown had a significant influence on the proportion of restorable versus unrestorable fractures. Although prosthodontics textbooks do not generally advocate the placement of fiber posts in endodontically treated incisors, the results of this study indicate that the use of fiber posts in such teeth increases their resistance to fracture and improves the prognosis in case of fracture.
Journal of Endodontics | 1998
Hani F. Ounsi; Gaby Haddad
A new generation of electronic apex locators (Endex) that operates in moistened canals has been developed lately. An experimental comparison of this apparatus with the real, tactile, and radiographic measurements of the root canal length has been conducted. Results show that tactile determination is highly inaccurate and that the Endex is as accurate as radiographic measurements. It also demonstrates that the nonreproducibility of radiographic measurements is statistically significant, whereas that of the Endex is not significant.
Journal of Dentistry | 2008
Ziad Salameh; Hani F. Ounsi; Moustafa N. Aboushelib; Walid Sadig; Marco Ferrari
OBJECTIVE The aim of this study was to investigate the influence of a fiber post on the fracture mechanics of zirconia crowns inserted over endodontically treated teeth with different extent of coronal damage. METHODS Endodontically treated human molars with three types of coronal damage received fiber posts before cementation of zirconia-veneered crowns. Controls received composite resin cores without fiber posts. The specimens were loaded to failure and fractographically examined using a scanning electron microscope (SEM). RESULTS Statistical analysis revealed that specimens with fiber posts demonstrated significantly higher failure loads and favorable fracture pattern compared to the controls. At fractographic analysis, specimens with fiber posts demonstrated delamination of the veneer ceramic from intact zirconia under structure. Meanwhile, the specimens that were restored without a fiber post demonstrated micro-cracking of the composite core build-up resulting in loss of the support under the zirconia crowns which was responsible for the initiation of radial crack and catastrophic damage. CONCLUSIONS Within the limitation of this study, the insertion of fiber post improved the support under zirconia crowns which resulted in higher fracture loads and favorable failure type compared to composite core build-up.
Journal of Endodontics | 2011
Hani F. Ounsi; Giovanni Franciosi; Raffaele Paragliola; Khalid Al Huzaimi; Ziad Salameh; Franklin R. Tay; Marco Ferrari; Simone Grandini
INTRODUCTION The shaping capacity of nickel-titanium (NiTi) rotary instruments is often assessed by photographic or micro-computed tomography (micro-CT) measurements, and these instruments are often used more than once clinically. This study was conducted to compare photographic and micro-CT measurements and to assess if the repeated use of NiTi instruments affected the shape of canal preparation. METHODS Ten new sets of ProTaper Universal instruments (Dentsply-Maillefer, Ballaigues, Switzerland) were used in 60 resin blocks simulating curved root canals. Groups 1 to 6 (n=10) represented the first to sixth use of the instrument, respectively. Digitized images of the prepared blocks were taken in both mesiodistal (MD) and buccolingual (BL) directions and area measurements (mm(2)) were calculated using AutoCAD (Autodesk Inc, San Rafael, CA). The volumes of the same prepared canals were measured using micro-CT (mm(3)). Statistical analysis was performed to detect differences between photographic and volumetric measurements and differences between uses. RESULTS Two-way repeated-measures analysis of variance revealed significant differences between groups (P < .001). Regarding measurement type, there were no significant differences between BL and MD measurements, but there were significant differences between micro-CT and BL measurements (P < .001) and micro-CT and MD measurements (P=.001). Significant differences were also noted between uses. CONCLUSIONS Within the limitations of the present study, micro-CT scanning is more discriminative of the changes in canal space associated with repeated instrument use than photographic measurements. Canal preparations are significantly smaller after the third use of the same instrument.
Journal of Prosthetic Dentistry | 2018
Elie E. Daou; Hani F. Ounsi; Mutlu Özcan; Nadin Al-Haj Husain; Ziad Salameh
Statement of problem. Limited information is available on the precision of new metal processing technologies. Purpose. The purpose of this in vitro study was to evaluate the marginal and internal fit of pre‐sintered cobalt‐chromium (Co‐Cr) and zirconia 3‐unit fixed dental prostheses using x‐ray microcomputed tomography. Material and methods. Three‐unit fixed dental prostheses were prepared on metal dies (N=12) using a typodont model from the maxillary first premolar to the first molar. A standardized preparation with a 1.2‐mm chamfer (360 degrees) and a 2‐mm occlusal reduction was prepared on abutment teeth. The dies were scanned and divided into 2 groups to receive the fixed dental prostheses (n=6) made of pre‐sintered Co‐Cr and pre‐sintered zirconia. Each framework was seated on its cast, and marginal and internal discrepancies were measured at 9 points, starting from the most distal point from the pontic for the maxillary first premolar and the first molar (points 1–4, mesial; point 5, occlusal; points 6–9, distal) of each abutment tooth using microcomputed tomography. The data were analyzed using the Levene test, t test, and ANOVA (&agr;=.05). Results. When overall mean discrepancy values were compared, no significant difference was observed between pre‐sintered Co‐Cr and pre‐sintered zirconia (P=.085). Discrepancy values for points 1, 2, and 3 were significantly different for pre‐sintered Co‐Cr and pre‐sintered zirconia, with the lowest mean values for point 1 and the highest for point 5. On the abutment tooth basis, for the maxillary first premolar and the first molar, a significant difference was found only in points 6 (P<.001) and 8 (P<.003) for both materials. When the discrepancies for the maxillary first premolar were considered for pre‐sintered Co‐Cr and pre‐sintered zirconia, the mean values were significantly different only at points 1 (P<.001), 2 (P=.007), and 3 (P=.003) and were smaller for pre‐sintered zirconia. For the tooth the first molar, a significant difference was observed at point 2 (P=.002) and point 3 (P=.008) for both materials, where the mean values were higher for pre‐sintered Co‐Cr than for pre‐sintered zirconia. The pairwise comparison between points showed a significant difference between measurement points within each material (P<.05). The increase in values between points 1 and 5 was evident for both pre‐sintered Co‐Cr and pre‐sintered zirconia materials. Conclusions. Three‐unit fixed dental prostheses made of pre‐sintered Co‐Cr or zirconia showed similar marginal and internal discrepancy values, with the highest discrepancy values at the occlusal region in both the first premolar and first molar.
Journal of Endodontics | 2018
Jorge N.R. Martins; Moataz-Bellah A.M. Alkhawas; Zaher Altaki; Gianmarco Bellardini; Luiza Berti; Carlos Boveda; Antonis Chaniotis; Daniel Flynn; Jose Antonio Gonzalez; Jojo Kottoor; Miguel Seruca Marques; Adam Monroe; Hani F. Ounsi; Peter Parashos; Gianluca Plotino; Magnús F. Ragnarsson; Rubén Rosas Aguilar; Fábio Santiago; Hussein C. Seedat; Walter Vargas; Murilo von Zuben; Yuerong Zhang; Yongchun Gu; António Ginjeira
Introduction: Maxillary first molar second mesiobuccal (MB2) root canal prevalence may change among different populations. The aim of this study was to analyze the worldwide prevalence of the MB2 root canal and understand its possible relation with sex, age, side, and root configuration using in vivo cone‐beam computed tomographic (CBCT) assessment. Methods: Observers from 21 regions were calibrated to achieve a similar CBCT assessment methodology and instructed to collect data from 250 maxillary first molars in previously existing examinations. Intra‐ and interrater reliability tests were performed. The sample size included 5250 molars and was defined by way of a preliminary trial. Data collected included MB2 presence, sex, age, side, number of roots per tooth, and mesiobuccal root configuration. The z test for proportions in independent groups was used to analyze the differences among subgroups. P < .05 was considered significant. Results: The worldwide CBCT‐assessed MB2 prevalence was 73.8%, ranging from 48.0% in Venezuela to 97.6% in Belgium. The prevalence in males and females was 76.3% and 71.8%, respectively (P < .05). Significantly higher MB2 proportions were found in younger patients and 3‐rooted molar configurations. The group intraclass correlation coefficient and the percentage of agreement for the MB2 presence were 0.95 and 0.91, respectively. The intrarater Cohen kappa value was above 0.61 for all observers. Conclusions: MB2 prevalence in the analyzed regions varied widely. The differences may be associated with specificities within each region but also patient demographics. Males, younger patients, and 3‐rooted configurations were associated with higher MB2 proportions.
BioMed Research International | 2018
Hasan Skienhe; Roland Habchi; Hani F. Ounsi; Marco Ferrari; Ziad Salameh
This study evaluated the effect of air abrasion before and after sintering with different particle type, shape, and size on the surface morphology, monoclinic phase transformation, and bond strength between resin cement and zirconia surface using primer containing silane and MDP. Airborne particle abrasion (APA) was performed on zirconia before and after sintering with different particle shape and size (50 μm Al2O3 and 25 μm silica powder). 120 square shaped presintered zirconia samples (Amann Girrbach) were prepared (3 mm height × 10 mm width × 10 mm length) and polished with grit papers #800, 1000, 1200, 1500, and 2000. Samples were divided into 6 groups according to surface treatment—group A: (control) no surface treatment; group B: APA 50 μm Al2O3 before sintering (BS); group C: APA 50 μm Al2O3 after sintering (AS); group D: APA25 μm silica powder (BS); group E: APA25 μm silica powder (AS) at a pressure of 3.5 bar; and group F: APA 25 μm silica powder (AS) at a pressure of 4 bar. Samples were analyzed using XRD, AFM, and SEM. The samples were submitted to shear bond strength (SBS) test. A dual cure resin cement (RelyX Ultimate) and primer (Scotchbond Universal) were used. Data were analyzed with ANOVA and Tukey test (α ≥ 0.05). APA in group B significantly increased the surface roughness when compared to all other groups. A significant monoclinic phase transformation (t-m) value was observed in groups C and F and a reverse transformation occurred in presintered groups. The SBS value of group A was 11.58 ± 1.43 and the highest significant shear bond strength value was for groups B (15.86 ± 1.92) and C (17.59 ± 2.21 MPa) with no significant difference between them. Conclusions. The use of APA 50 μm Al2O3 before sintering and the application of primer containing MDP seem to be valuable methods for durable bonding with zirconia. The use of APA 50 μm Al2O3 after sintering induced the highest (t-m) phase transformation.
Actual problems in dentistry | 2015
Марко Феррари; Marco Ferrari; Зиад Саламех; Ziad Salameh; Хани Ф. Оунси; Hani F. Ounsi; Мустафа Н. Абушелиб; Moustafa N. Aboushelib; Рана Аль-Хамдан; Rana Al-Hamdan; Валид Садиг; Walid Sadig
PURPOSE To investigate the relationship between post and core build-up materials on the fracture resistance of endodontically treated teeth restored with different onlay restorations. METHODS 60 mandibular molars were endodontically treated and divided into three experimental groups that received one of the following onlay restorations: gold onlays, glass ceramic onlays (Empress I), or resin composite onlays (Gradia). Half of the specimens in each group received a fiber post (n=10). Two controls groups (n=10) were included: one group composed of sound mandibular molars, and the second group was composed of endodontically treated unrestored molars. Fracture tests were carried out by applying axial load using a universal loading machine until fracture. All fractured specimens were fractographically examined using a scanning electron microscope (SEM). Data were analyzed using two-way ANOVA and Tukey multiple comparison tests (alpha=0.05). RESULTS Statistical analysis showed that restoration of endodontically treated teeth with gold onlays improved fracture resistance when compared to glass ceramic or resin composite onlays. The presence of a fiber post significantly improved (P<0.045) fracture resistance of gold onlays from 2271 to 2874N while it did not influence the performance of the other two groups. Fractographic analyses revealed that the presence of fiber post resulted in more restorable fractures due to better stress distribution of the applied load. All onlay systems resulted in significant improvement of the fracture resistance compared to unrestored teeth (711N) but neither of them resulted in restoring the fracture resistance to match that of sound teeth (3212 N).Purpose: To investigate the relationship between post and core build-up materials on the fracture resistance of endodontically treated teeth restored with different onlay restorations. Methods: 60 mandibular molars were endodontically treated and divided into three experimental groups that received one of the following onlay restorations: gold onlays, glass ceramic onlays, or resin composite onlays. Half of the specimens in each group received a fiber post (n = 10). Two controls groups (n = 10) were included: one group composed of sound mandibular molars, and the second group was composed of endodontically treated unrestored molars. Fracture tests were carried out by applying axial load using a universal loading machine until fracture. All fractured specimens were fractographically examined using a scanning electron microscope. Data were analyzed using two-way ANOVA and Tukey multiple comparison tests (a = 0.05). Results: Statistical analysis showed that restoration of endodontically treated teeth with gold onlays improved fracture resistance when compared to glass ceramic or resin composite onlays. The presence of a fiber post significantly improved (P< 0.045) fracture resistance of gold onlays from 2271 to 2874N while it did not influence the performance of the other two groups. Fractographic analyses revealed that the presence of fiber post resulted in more restorable fractures due to better stress distribution of the applied load. All onlay systems resulted in significant improvement of the fracture resistance compared to unrestored teeth (711N) but neither of them resulted in restoring the fracture resistance to match that of sound teeth (3212 N). (Am J Dent 2010; 23: 81-86).