Pflügers Archiv: European Journal of Physiology | 1977

The continuous high-precision measurement of the density of flowing blood

Thomas Kenner; Hans Leopold; Helmut Hinghofer-Szalkay

SummaryThe “mechanical oscillator” technique for the measurement of the density of fluids is based on the influence of mass on the natural frequency of a mechanical oscillator. The practical application of this principle was worked out by Kratky et al. (1969) and Leopold (1970). It is demonstrated in this study that the method permits the continuous high-precision measurement of the density of flowing blood in anesthetized animals. The accuracy is 10−5 g/ml, the maximum sampling rate 20/min.As found in rabbits and cats during the control state, physiological blood density changes related to spontaneous blood pressure variations are up to 2·10−4 g/ml. The method can be combined with i.v. injections of isotonic and iso-oncotic solutions to determine cardiac output and blood volume on the basis of a “density dilution” principle. Since the density of the interstitial fluid is lower than that of blood, fluid shifts through the capillary walls can be detected. The effects of hypertonic glucose and of hyperoncotic dextran have been examined. Changes in the density of the arterial blood appear within 10 s after i.v. injection of these fluids. Similarly, density changes result from hemorrhage and reinfusion. During and after i.v. administration of vasoactive drugs (noradrenaline, angiotensin II, acetylcholine), marked transient changes in blood density are seen which obviously reflect the effects of fluid shifts through the capillary walls. During hemorrhagic hypotension we found periodic variations in the blood density synchronous with spontaneously occurring Mayer waves. The new method seems to be a promising tool for investigations on physiological and pathological capillary fluid dynamics.


Monatshefte Fur Chemie | 1978

Präzisionsmessung der Dichte einiger organischer Flüssigkeiten nach der Biegeschwingermethode

Rainer M. Jelinek; Hans Leopold

The densities of the pure organic liquids: cyclohexane, nitrobenzene, 1-hexanol, 1-octanol, 1-decanol, and 1-dodecanol have been measured with an accuracy of 10−5 g/cm3 using the mechanical oscillator technique. The results were compared to the values given in the literature. From the measured densities the coefficients of thermal expansion were calculated.


Monatshefte Fur Chemie | 1967

Eine neue Methode zur Präzisionsmessung der Dichte von Flüssigkeiten

Hans Stabinger; Hans Leopold; O. Kratky


Archive | 1992

Resistance ratio measurement utilizing measuring currents of opposite plural direction

Hans Leopold; Hans Stabinger; Klaus Peter Dr. Schröcker


Archive | 1992

Apparatus for determining the density of liquids and gases from a period of an oscillator filled with a test sample

Hans Stabinger; Hans Leopold


Archive | 1977

Apparatus for density determination

O. Kratky; Hans Leopold; Hans Stabinger


Archive | 1988

Density measuring instrument

Hans Leopold; Hans Stabinger


Archive | 1984

Einrichtung zur untersuchung von fluessigkeitseigenschaften

Helmut Heimel; Hans Leopold; Hans Stabinger


Angewandte Makromolekulare Chemie | 1978

Die Messung der Dichte zur Detektion in der Gelchromatographie. 1. Untersuchungen an Poly(propylenoxiden)

Hans Leopold; Bernd Trathnigg


Archive | 1984

Device for investigating liquid properties

Helmut Heimel; Hans Leopold; Hans Stabinger