Hans U. Kerl
Heidelberg University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Hans U. Kerl.
PLOS ONE | 2012
Teresa Fiebig; Hanne Boll; Giovanna Figueiredo; Hans U. Kerl; Stefanie Nittka; Christoph Groden; Martin Kramer; Marc A. Brockmann
Various murine models are currently used to study acute and chronic pathological processes of the liver, and the efficacy of novel therapeutic regimens. The increasing availability of high-resolution small animal imaging modalities presents researchers with the opportunity to precisely identify and describe pathological processes of the liver. To meet the demands, the objective of this study was to provide a three-dimensional illustration of the macroscopic anatomical location of the murine liver lobes and hepatic vessels using small animal imaging modalities. We analysed micro-CT images of the murine liver by integrating additional information from the published literature to develop comprehensive illustrations of the macroscopic anatomical features of the murine liver and hepatic vasculature. As a result, we provide updated three-dimensional illustrations of the macroscopic anatomy of the murine liver and hepatic vessels using micro-CT. The information presented here provides researchers working in the field of experimental liver disease with a comprehensive, easily accessable overview of the macroscopic anatomy of the murine liver.
Acta Neurochirurgica | 2012
Ingo Nölte; Lars Gerigk; Mansour Al-Zghloul; Christoph Groden; Hans U. Kerl
BackgroundDeep-brain stimulation (DBS) of the internal globus pallidus (GPi) has shown remarkable therapeutic benefits for treatment-resistant neurological disorders including dystonia and Parkinson’s disease (PD). The success of the DBS is critically dependent on the reliable visualization of the GPi.The aim of the study was to evaluate promising 3.0 Tesla magnetic resonance imaging (MRI) methods for pre-stereotactic visualization of the GPi using a standard installation protocol.MethodsMRI at 3.0 T of nine healthy individuals and of one patient with PD was acquired (FLAIR, T1-MPRAGE, T2-SPACE, T2*-FLASH2D, susceptibility-weighted imaging mapping (SWI)). Image quality and visualization of the GPi for each sequence were assessed by two neuroradiologists independently using a 6-point scale. Axial, coronal, and sagittal planes of the T2*-FLASH2D images were compared. Inter-rater reliability, contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR) for the GPi were determined. For illustration, axial T2*-FLASH2D images were fused with a section schema of the Schaltenbrand-Wahren stereotactic atlas.ResultsThe GPi was best and reliably visualized in axial and to a lesser degree on coronal T2*-FLASH2D images. No major artifacts in the GPi were observed in any of the sequences. SWI offered a significantly higher CNR for the GPi compared to standard T2-weighted imaging using the standard parameters. The fusion of the axial T2*-FLASH2D images and the atlas projected the GPi clearly in the boundaries of the section schema.ConclusionsUsing a standard installation protocol at 3.0 T T2*-FLASH2D imaging (particularly axial view) provides optimal and reliable delineation of the GPi.
Academic Radiology | 2013
Hanne Boll; Giovanna Figueiredo; Teresa Fiebig; Stefanie Nittka; Fabian Doyon; Hans U. Kerl; Ingo Nölte; Alex Förster; Martin Kramer; Marc A. Brockmann
RATIONALE AND OBJECTIVES The purpose of this study was to compare different contrast agents for longitudinal liver and spleen imaging in a mouse model of liver metastasis. MATERIALS AND METHODS Mice developing liver metastases underwent longitudinal micro-computed tomography imaging after injection of Fenestra LC, ExiTron nano 6000, or ExiTron nano 12000. Elimination times and contrast enhancement of liver and spleen were compared. RESULTS For all contrast agents, liver contrast peaked at approximately 4 hours and spleen contrast at 48 hours postinjection. A single dose of 100 μL of ExiTron nano 6000 or 12000 resulted in longstanding enhancement of liver and spleen tissue for longer than 3 weeks, whereas repeated injections of 400 μL of Fenestra LC were required to retain contrast at acceptable levels and allowed imaging of the liver/spleen for up to 2 and 9 days, respectively. CONCLUSION Both ExiTron nano agents provide longer and stronger contrast enhancement of liver and spleen compared to Fenestra LC, and they do so at a 75% lower injection volume in mice.
Journal of Neurosurgery | 2012
Hans U. Kerl; Lars Gerigk; Ioannis Pechlivanis; Mansour Al-Zghloul; Christoph Groden; Ingo Nölte
OBJECT Reliable visualization of the subthalamic nucleus (STN) is indispensable for accurate placement of electrodes in deep brain stimulation (DBS) surgery for patients with Parkinson disease (PD). The aim of the study was to evaluate different promising new MRI methods at 3.0 T for preoperative visualization of the STN using a standard installation protocol. METHODS Magnetic resonance imaging studies (T2-FLAIR, T1-MPRAGE, T2*-FLASH2D, T2-SPACE, and susceptibility-weighted imaging sequences) obtained in 9 healthy volunteers and in 1 patient with PD were acquired. Two neuroradiologists independently analyzed image quality and visualization of the STN using a 6-point scale. Interrater reliability, contrast-to-noise ratios, and signal-to-noise ratios for the STN were calculated. For illustration of the anatomical accuracy, coronal T2*-FLASH2D images were fused with the corresponding coronal section schema of the Schaltenbrand and Wahren stereotactic atlas. RESULTS The STN was best and reliably visualized on T2*-FLASH2D imaging (in particular, the coronal view). No major artifacts in the STN were observed in any of the sequences. Susceptibility-weighted, T2-SPACE, and T2*-FLASH2D imaging provided significantly higher contrast-to-noise ratio values for the STN than standard T2-weighted imaging. Fusion of the coronal T2*-FLASH2D and the digitized coronal atlas view projected the STN clearly within the boundaries of the STN found in anatomical sections. CONCLUSIONS For 3.0-T MRI, T2*-FLASH2D (particularly the coronal view) provides optimal delineation of the STN using a standard installation protocol.
Cephalalgia | 2014
Alex Förster; Holger Wenz; Hans U. Kerl; Marc A. Brockmann; Christoph Groden
Objectives Migraine with aura is a common neurological disorder, and differentiation from transient ischemic attack or stroke based on clinical symptoms may be difficult. Methods From an MRI report database we identified 33 patients with migraine with aura and compared these to 33 age-matched ischemic stroke patients regarding perfusion patterns on perfusion-weighted imaging (PWI)-derived maps: time to peak (TTP), mean transit time (MTT), and cerebral blood flow and volume (CBF, CBV). Results In 18/33 (54.5%) patients with migraine with aura, TTP showed areas of hypoperfusion, most of these not limited to the territory of a specific artery but affecting two or more vascular territories. In patients with migraine with aura, TTP (1.09 ± 0.05 vs. 1.47 ± 0.40, p < 0.001) and MTT ratios (1.01 ± 0.10 vs. 1.19 ± 0.21, p = 0.003) were significantly lower compared to patients with ischemic stroke. In contrast to this, CBF and CBV ratios did not differ significantly between both groups. Conclusions Migraine aura is usually associated with a perfusion deficit not limited to a specific vascular territory, and only a moderate increase of TTP. Thus, hypoperfusion restricted to a single vascular territory in combination with a marked increase of TTP or MTT may be regarded as atypical for migraine aura and suggestive of acute ischemic stroke.
Neurosurgery | 2014
Hans U. Kerl; Hanne Boll; Teresa Fiebig; Giovanna Figueiredo; Alex Förster; Ingo Nölte; Andrea Nonn; Christoph Groden; Marc A. Brockmann
BACKGROUND Flow-diverting stent (FDS) implantation is an endovascular treatment option for intracranial aneurysms. However, little is known about the hemodynamic effects. OBJECTIVE To assess the effect of stent compression on FDS porosity, to evaluate the influence of single and overlapping implantation of FDS on intra-aneurysmal flow profiles, and to correlate stent porosity with changes in static mean intra-aneurysmal pressure. METHODS Intra-aneurysmal time-density curves were recorded in a pulsatile in vitro flow model before and after implantation of FDSs (Pipeline Embolization Device; ev3) in 7 different types of aneurysm models. Reductions in the maximum contrast inflow and time to maximum intra-aneurysmal contrast were calculated. Micro--computed tomography was performed, and compression-related FDS porosity was measured. The influence of FDS placement on mean static intra-aneurysmal pressure was measured. RESULTS FDS compression resulted in an almost linear reduction in stent porosity. Stent porosity (struts per 1 mm) correlated significantly with the reduction of aneurysm contrast inflow (R = 0.81, P < .001) and delay until maximum contrast (R = 0.34, P = .001). Circulating intra-aneurysmal high-velocity flow was terminated in all sidewall models after implantation of a single stent. Superimposition of 2 stents reduced maximum intra-aneurysmal contrast by 69.1 ± 3.1% (mean ± SD) in narrow-necked sidewall aneurysm models, whereas no substantial reduction in maximum intra-aneurysmal contrast was observed in wide-necked sidewall aneurysm models. Intra-aneurysmal mean static pressure did not correlate with FDS porosity or number of implanted stents. CONCLUSION Implantation of FDS effectively reduces aneurysm inflow in a porosity-dependent way without relevantly affecting static mean intra-aneurysmal pressure. ABBREVIATIONS FDS, flow-diverting stentMAP, mean arterial pressurePED, Pipeline Embolization Device.
Journal of Computer Assisted Tomography | 2011
Hans U. Kerl; Cristina T. Isaza; Hanne Boll; Sebastian J. Schambach; Ingo Nölte; Christoph Groden; Marc A. Brockmann
Objective: Micro-computed tomography is used frequently in preclinical in vivo research. Limiting factors are radiation dose and long scan times. The purpose of the study was to compare a standard step-and-shoot to a continuous-rotation, high-speed scanning protocol. Methods: Micro-computed tomography of a lead grid phantom and a rat femur was performed using a step-and-shoot and a continuous-rotation protocol. Detail discriminability and image quality were assessed by 3 radiologists. The signal-to-noise ratio and the modulation transfer function were calculated, and volumetric analyses of the femur were performed. The radiation dose of the scan protocols was measured using thermoluminescence dosimeters. Results: The 40-second continuous-rotation protocol allowed a detail discriminability comparable to the step-and-shoot protocol at significantly lower radiation doses. No marked differences in volumetric or qualitative analyses were observed. Conclusions: Continuous-rotation micro-computed tomography significantly reduces scanning time and radiation dose without relevantly reducing image quality compared with a normal step-and-shoot protocol.
World Journal of Radiology | 2013
Hans U. Kerl; Lars Gerigk; Marc A. Brockmann; Sonia Huck; Mansour Al-Zghloul; Christoph Groden; Thomas H. Hauser; Armin M. Nagel; Ingo Nölte
AIM To evaluate different promising magnetic resonance imaging (MRI) methods at 7.0 Tesla (T) for the pre-stereotactic visualization of the zona incerta (ZI). METHODS Two neuroradiologists qualitatively and quantitatively examined T2-turbo spin-echo (T2-TSE), T1-weighted gradient-echo, as well as FLASH2D-T2Star and susceptibility-weighted imaging (SWI) for the visualization of the ZI at 7.0 T MRI. Delineation and image quality for the ZI were independently examined using a 6-scale grading system. Inter-rater reliability using Cohens kappa coefficient (κ) were assessed. Contrast-to-noise ratios (CNR), and signal-to-noise ratios (SNR) for the ZI were calculated for all sequences. Differences in delineation, SNR, and CNR between the sequences were statistically assessed using a paired t-test. For the anatomic validation the coronal FLASH2D-T2Star images were co-registered with a stereotactic atlas (Schaltenbrand-Wahren). RESULTS The rostral part of the ZI (rZI) could easily be identified and was best and reliably visualized in the coronal FLASH2D-T2Star images. The caudal part was not definable in any of the sequences. No major artifacts in the rZI were observed in any of the scans. FLASH2D-T2Star and SWI imaging offered significant higher CNR values for the rZI compared to T2-TSE images (P > 0.05). The co-registration of the coronal FLASH2D-T2Star images with the stereotactic atlas schema (Schaltenbrand-Wahren) confirmed the correct localization of the ZI in all cases. CONCLUSION FLASH2D-T2Star imaging (particularly coronal view) provides the reliable and currently optimal visualization of the rZI at 7.0 T. These results can facilitate a better and more precise targeting of the caudal part of the ZI than ever before.
PLOS ONE | 2013
Alex Förster; Hans U. Kerl; Holger Wenz; Marc A. Brockmann; Ingo Nölte; Christoph Groden
Purpose Characterization of lacunar infarction (LI) by use of multimodal MRI including diffusion- and perfusion-weighted imaging (DWI, PWI) is difficult because of the small lesion size. Only a few studies evaluated PWI in LI and the results are inconsistent. Methods In 16 LI patients who underwent initial MRI within 6 hours after symptom onset and follow-up MRI within 1 week demographics, clinical presentation, and MRI findings were analyzed with special emphasis on DWI and PWI findings. Time to peak maps were classified as showing a normal perfusion pattern or areas of hypoperfusion which were further categorized in mismatch (PWI>DWI), inverse mismatch (PWI<DWI), and match (PWI=DWI). Quantitative perfusion maps were generated and analyzed by use of Signal Processing in NMR-Software (SPIN). Results Of the 16 patients (mean age 65.5±12.9 years), 14 (87.5%) were male. Clinical symptoms comprised dysarthria (50%), hemiparesis (81.3%), and hemihypaesthesia (18.8%). Intravenous thrombolysis was performed in 7 (43.8%) patients. Clinical improvement was observed in 12 patients (75 %), while 2 (12.5%) patients showed a deterioration and another 2 (12.5%) a stable course. Acute ischemic lesions (mean volume of 0.46±0.29 cm3) were located in the thalamus (n=8, 50%), internal capsule (n=4, 25%), corona Radiata (n=3, 18.8%) and the mesencephalon (n=1, 6.3%). Circumscribed hypoperfusion (mean volume 0.61±0.48 cm3) was evident in 10 (62.5%) patients. Of these, 3 patients demonstrated a match, 4 an inverse mismatch, and 3 a mismatch between DWI and PWI lesion. Mean CBF and CBV ratios were 0.65±0.28 and 0.84±0.41 respectively. Growth of DWI lesions was observed in 7 (43.8%) and reversal of DWI lesions in 3 (18.8%) patients. Conclusions MRI allows identification of different DWI and PWI patterns in LI, including growth and reversal of ischemic lesions. Consequently, it may serve for a better characterization of this stroke subtype and support treatment decisions in daily clinical practice.
Journal of Neuroimaging | 2014
Alex Förster; Ingo Nölte; Holger Wenz; Mansour Al-Zghloul; Hans U. Kerl; Marc A. Brockmann; Christoph Groden
Bilateral paramedian thalamic infarction is a rare subtype of stroke the etiology of which still remains undetermined in many patients.