Harald Althaus
Siemens
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Harald Althaus.
Clinical Chemistry and Laboratory Medicine | 2010
Anders Grubb; Soren Blirup; Veronica Lindström; C. Schmidt; Harald Althaus; Ingrid Zegers
Abstract The IFCC Working Group for the Standardisation of Cystatin C (WG-SCC), in collaboration with the Institute for Reference Materials and Measurements (IRMM), announces the availability of the new certified reference material ERM-DA471/IFCC. The material was characterised using a pure protein primary reference preparation (PRP) as calibrant. The PRP was prepared from recombinant cystatin C, and its concentration measured using dry mass determination. The characterisation of ERM-DA471/IFCC was performed by particle enhanced immuno-nephelometry, particle enhanced immuno-turbidimetry, and enzyme amplified single radial immuno-diffusion. The certified cystatin C mass concentration in ERM-DA471/IFCC, if reconstituted according to the specified procedure, is 5.48 mg/L, the expanded uncertainty (k=2) being 0.15 mg/L. Clin Chem Lab Med 2010;48:1619–21.
Clinical Chemistry | 2014
Anders Grubb; Masaru Horio; Lars-Olof Hansson; Jonas Björk; Ulf Nyman; Mats Flodin; Anders Larsson; Arend Bökenkamp; Yoshinari Yasuda; Hester N. Blufpand; Veronica Lindström; Ingrid Zegers; Harald Althaus; Søren Blirup-Jensen; Yoshi Itoh; Per Sjöström; Gunnar Nordin; Anders Christensson; Horst Klima; Kathrin Sunde; Per Hjort-Christensen; David Armbruster; Ferrero Ca
BACKGROUND Many different cystatin C-based equations exist for estimating glomerular filtration rate. Major reasons for this are the previous lack of an international cystatin C calibrator and the nonequivalence of results from different cystatin C assays. METHODS Use of the recently introduced certified reference material, ERM-DA471/IFCC, and further work to achieve high agreement and equivalence of 7 commercially available cystatin C assays allowed a substantial decrease of the CV of the assays, as defined by their performance in an external quality assessment for clinical laboratory investigations. By use of 2 of these assays and a population of 4690 subjects, with large subpopulations of children and Asian and Caucasian adults, with their GFR determined by either renal or plasma inulin clearance or plasma iohexol clearance, we attempted to produce a virtually assay-independent simple cystatin C-based equation for estimation of GFR. RESULTS We developed a simple cystatin C-based equation for estimation of GFR comprising only 2 variables, cystatin C concentration and age. No terms for race and sex are required for optimal diagnostic performance. The equation, [Formula: see text] is also biologically oriented, with 1 term for the theoretical renal clearance of small molecules and 1 constant for extrarenal clearance of cystatin C. CONCLUSIONS A virtually assay-independent simple cystatin C-based and biologically oriented equation for estimation of GFR, without terms for sex and race, was produced.
Scandinavian Journal of Clinical & Laboratory Investigation | 2008
Søren Blirup-Jensen; Anders Grubb; Veronica Lindström; C. Schmidt; Harald Althaus
A Primary Reference Preparation has been produced using pure, recombinant, Cystatin C in a solvent of 0.1 mol/L KCl. Dry mass determination of the Primary Reference Preparation resulted in a Cystatin C concentration of 5.20 g/L. Agarose‐electrophoresis and SDS‐electrophoresis, as well as N‐terminal sequencing, verified the purity, homogeneity and identity of Cystatin C in the Primary Reference Preparation. For the Secondary Reference Preparation, a serum pool was collected and stabilized. A pilot batch was made to verify the selected procedure and spiking with the pure, recombinant Cystatin C. The final Secondary Reference Preparation is now produced (4468 vials) and ready for value assignment and further characterization.
Clinical Chemistry and Laboratory Medicine | 2011
Henk te Velthuis; Ingrid Knop; Peter Stam; Monic van den Broek; Hannie Klaasse Bos; Suzanne Hol; Elisa Teunissen; Karin Schulte Fischedick; Harald Althaus; Brigitta Schmidt; Carola Wagner; Roel Melsert
Abstract Background: High serum concentrations of monoclonal free light chain (FLC) kappa or lambda are markers of plasma cell dyscrasia. Methods: We developed new, latex-enhanced, specific nephelometric assays based on monoclonal antibodies for the determination of FLC kappa and lambda in serum, EDTA plasma and Li-heparin plasma for use on the Siemens BN™ systems. Results: Reference ranges were determined from 369 samples: FLC kappa 6.7–22.4 mg/L, FLC lambda 8.3–27.0 mg/L and kappa/lambda ratio 0.31–1.56. Protection from falsely low results due to antigen excess is obtained with a built-in pre-reaction in the assay protocols. Lot-to-lot consistency between three different lots of reagent, calibrators and supplementary reagent lots showed normalized differences <7.5%. The reproducibility of serum samples varied between 4% and 7%. The method comparison with Freelite™ assays showed normalized differences of 19.7%, 32.7% and 21.7%, respectively, for FLC kappa, lambda and ratio, correlations of 0.94, 0.77 and 0.73, and concordance rates of 99.2%, 94.2% and 95%. Conclusions: N Latex FLC demonstrates high precision, good lot-to-lot consistency and freedom from a high-dose hook effect. The method comparison between Freelite™ and the N Latex FLC assays showed good clinical concordance. Further studies need to reveal the clinical value of the new FLC assays.
Clinical Chemistry and Laboratory Medicine | 2010
Andreas Kappel; Sina Stephan; Gerlinde Christ; Lena Pechmann; Christa Duwe; Bodo Fischer; Martin Hahn; Harald Althaus; Matthias Ehm; Herbert Schwarz; Frank Vitzthum
Abstract Background: Accurate determination of factor XIII (FXIII) activity is crucial for replacement therapy. FXIII activity is typically determined using a coupled enzymatic reaction that measures nicotinamide adenine dinucleotide hydride (NADH) consumption at 340 nm. Methods: Here, we describe the development of a prototype for a novel FXIII activity assay for detection at 405 nm by replacing NADH with thio-NADH, and the application of FXIII immuno-depleted plasma as a diluent for calibration. Results: Performance data show up to two-fold lower susceptibility of the prototype assay to interferences from hemolyzed, icteric, and lipemic samples when compared to a NADH assay format. In addition, the use of FXIII immuno-depleted plasma as diluent for calibration improved recovery almost two-fold in the lower measurement range. The novel prototype assay correlates well with a conventional assay (r=0.98, y=0.99·x+2.17% FXIII, n=173). Conclusions: The described prototype assay has the potential to (a) increase trueness of measurement of low levels of FXIII, (b) improve robustness due to reduction from interferences, and (c) can be used on a broad range of coagulation instruments due to its detection at 405 nm. Clin Chem Lab Med 2010;48:1739–43.
Clinical Chemistry and Laboratory Medicine | 2010
Herbert Schwarz; Sina Stephan; Johannes Jakobsen Sidelmann; Bodo Fischer; Harald Althaus; Martin Hahn; Andreas Kappel; Matthias Ehm; Frank Vitzthum
Abstract Background: The Marburg I (MRI) single nucleotide poly-morphism (SNP) of the factor VII-activating protease (FSAP) gene has been associated with thrombophilia, thromboembolism, atherosclerosis, and the incidence and progression of carotid stenosis. At present, MRI SNP testing is mainly performed using costly nucleic acid analysis. The ratio between FSAP activity and antigen concentrations in citrated plasma has been used to assess the FSAP genotype. Methods: This article describes the development of a prototype ELISA for the detection of the MRI FSAP alloenzyme, and its correlation to FSAP genotypes to assess whether a positive MRI FSAP ELISA result may be used as a surrogate marker for the presence of the MRI SNP. Results: ELISA results were correlated with FSAP genotypes from 523 blood donors measured using PCR. Diagnostic sensitivity and specificity of the assay for determina-tion of the genotype were 100% (95% confidence interval [CI]: 93.36–100) and 99.79% (95% CI: 98.80–99.96), respectively. Maximum run-to-run, within-run, and total coefficients of variation were 7.8%, 7.9%, and 9.9%, respectively. No cross-reactivities with homologues of the MRI FSAP alloenzyme were observed. Test performance was not affected by typical interfering compounds. Conclusions: The data demonstrate that an immunoassay applying antibodies specific to the MRI FSAP alloenzyme can provide sufficiently accurate detection of the MRI SNP. This will significantly simplify MRI FSAP testing, particularly in large cohorts. Clin Chem Lab Med 2010;48:1745–9.
Hamostaseologie | 2011
Andreas Kappel; S. Stephan; C. Duwe; L. Pechmann; Harald Althaus; Mathias Ehm; B. Fischer; Martin Hahn; Herbert Schwarz; Frank Vitzthum
UNLABELLED Coagulation factor XIII (FXIII) is essential for clot stabilization. Deficiency of FXIII is associated with a risk of bleeding and impaired wound healing. Substitution therapy with FXIII remedies for patients with low plasma levels of FXIII requires diagnostic quantification of the factor before and during therapy. Here, we describe a prototype of a preliminary research immunoassay for quantification of FXIII antigen on automated coagulation instruments. The prototype assay is based on a monoclonal antibody (mAb) directed against FXIII A chain, whereas the mAbs are coupled to latex particles. FXIII in a plasma specimen causes agglutination of the latex particles, which can be quantified turbidimetrically. Performance data of the assay prototype processed on BCS® XP and Sysmex® CA-1500 instruments demonstrate a good correlation to the Berichrom® factor XIII activity assay1 from Siemens Healthcare Diagnostics (r = 0.94). RESULTS Comparability of instruments was excellent (r = 0.98). Coefficients of variation of total imprecision measurements ranged from 2.2 to 3.4%. Linearity was excellent over the range tested (12-121% FXIII). Analytical sensitivity was 0.51% FXIII on BCS XP and 0.44% FXIII on Sysmex CA-1500, respectively. No interference (>10% bias) was observed with haemoglobin (up to 400 mg/dl), cholesterol (up to 300 mg/dl), bilirubin (up to 60 mg/dl) or triglycerides (up to 3000 mg/dl). CONCLUSION The preliminary research assay prototype has the potential for excellent analytical sensitivity, precision, and dynamic range suitable to measure reliably FXIII antigen levels in human plasma.
Clinical Chemistry and Laboratory Medicine | 2011
Andreas Kappel; Sina Stephan; Gerlinde Christ; Anja Haude-Barten; Madeleine Dahm; Herbert Schwarz; Bodo Fischer; Martin Hahn; Harald Althaus; Matthias Ehm; Frank Vitzthum
Abstract Background: The Luminescent Oxygen Channeling Immunoassay (LOCI®) technology is a well-established homogeneous assay format that allows for fast, accurate, and highly sensitive quantitation of analytes. We set out to develop and prove a novel concept to establish a LOCI format that should principally allow for the determination of the activity of coagulation factors and anticoagulants of clinical relevance. Methods: The concept is based on the linkage of LOCI nano-beads by a peptide that can be cleaved by a coagulation factor. To prove the principle, we used a peptide that can be cleaved by thrombin. Results: We were able to show that coagulation activation of plasma or whole blood samples that were combined with the LOCI components degraded the thrombin-sensitive peptide and consequently, led to a reduction of the LOCI signal. Signal reduction was proportional to the amount of active thrombin generated. The research prototype assay allowed for the detection of factor deficiencies in both the extrinsic and intrinsic coagulation pathways, and for the quantification of hirudin, a direct thrombin inhibitor. Conclusions: Taken together, we conclude that the LOCI technology has the potential for extension to functional blood coagulation assays.
Clinical Chemistry and Laboratory Medicine | 2011
Lars-Olof Hansson; Mats Flodin; Anders Larsson; Harald Althaus; Søren Blirup-Jensen; Anders Grubb
The first harmonization step on cystatin C, with the aim to introduce the first ERM-DA471/IFCC cystatin C calibrator and one worldwide company-independent EGFR equation
Clinical Chemistry and Laboratory Medicine | 2011
Sina Stephan; Herbert Schwarz; Anja Haude-Barten; Johannes Jakobsen Sidelmann; Bodo Fischer; Harald Althaus; Martin Hahn; Andreas Kappel; Matthias Ehm; Frank Vitzthum
Abstract Background: The Marburg I (MRI) single nucleotide polymorphism (SNP) of the factor VII-activating protease (FSAP) gene has been associated with thrombophilia and atherosclerotic disease. PCR is used to detect the SNP. Also, the specific FSAP activity to cleave single-chain urokinase-type plasminogen activator (scu-PA) serves as a surrogate for PCR testing. Development of further assays is indicated in order to increase testing opportunities for future studies. Methods: A direct chromogenic substrate immuno-capture activity assay for FSAP (FSAP dcs activity assay) was established. Performance characteristics of the FSAP dcs activity assay were compared to the FSAP scu-PA activity assay. Results: The FSAP dcs activity assay detects FSAP activity from 25% to 150% of the norm. Total CVs ranged from 6% to 10% for FSAP wild type samples and 9%–18% for MRI samples. Correlation between the FSAP dcs and scu-PA activity assays was low (R=0.7). The FSAP dcs activity determined the presence of the MRI FSAP alloenzyme with a diagnostic sensitivity and specificity of 100% [95% confidence interval (CI): 89.6%–100%] and 96.2% (95% CI: 93.2%–97.4%), respectively, whereas the specific FSAP dcs activity increased specificity to 99.0% (95% CI: 97.2%–99.6%). Conclusions: The specific FSAP dcs activity represents a reliable method for the detection of the FSAP MRI alloenzyme. Due to the limited correlation between the FSAP dcs and scu-PA activity assays, these different measurands may exhibit different utility in research and clinical applications. Thus, the FSAP dcs activity assay can represent a valuable complement or alternative for FSAP testing in future studies.