Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Haruhiko Miyagawa is active.

Publication


Featured researches published by Haruhiko Miyagawa.


Forensic Toxicology | 2013

Mass spectrometric differentiation of the isomers of mono-methoxyethylamphetamines and mono-methoxydimethylamphetamines by GC–EI–MS–MS

Kei Zaitsu; Haruhiko Miyagawa; Yuki Sakamoto; Shuntaro Matsuta; Kento Tsuboi; Hiroshi Nishioka; Munehiro Katagi; Takako Sato; Michiaki Tatsuno; Hitoshi Tsuchihashi; Koichi Suzuki; Akira Ishii

Mass spectrometric differentiation of the six isomers of mono-methoxyethylamphetamines (MeO-EAs) and mono-methoxydimethylamphetamines (MeO-DMAs) by gas chromatography–electron ionization–tandem mass spectrometry (GC–EI–MS–MS) was investigated. Based on their EI-mass spectra, the fragment ions at m/z 121 and 72 were selected as precursor ions for their regioisomeric and structurally isomeric differentiation, respectively. Collision-induced dissociation provides intensity differences in product ions among the isomers, enabling mass spectrometric differentiation of the isomers. Furthermore, high reproducibility of the product ion spectra at the optimized collision energy was confirmed, demonstrating the reliability of the method. To our knowledge, this is the first report on mass spectrometric differentiation of the six isomers of MeO-EAs and MeO-DMAs by GC–EI–MS–MS. Isomeric differentiation by GC–EI–MS–MS has a high potential to discriminate isomers of newly encountered designer drugs, making GC–MS–MS a powerful tool in the forensic toxicology field.


Talanta | 2014

Simultaneous detection of multiple hydroxylated polychlorinated biphenyls from a complex tissue matrix using gas chromatography/isotope dilution mass spectrometry

Akifumi Eguchi; Kei Nomiyama; Mari Ochiai; Hazuki Mizukawa; Yasuko Nagano; Katsuhiro Nakagawa; Kouki Tanaka; Haruhiko Miyagawa; Shinsuke Tanabe

In this study, we developed a comprehensive, highly sensitive, and robust method for determining 53 congeners of three to eight chlorinated OH-PCBs in liver and brain samples by using isotope dilution gas chromatography (GC) coupled with electron capture negative ionization mass spectrometry (ECNI-MS). These results were compared with those from GC coupled with electron ionization high-resolution mass spectrometry (EI-HRMS). Clean-up procedures for analysis of OH-PCBs homologs in liver and brain samples involve a pretreatment step consisting of acetonitrile partition and 5% hydrated silica-gel chromatography before derivatization. Recovery rates of tri- and tetra-chlorinated OH-PCBs in the acetonitrile partition method followed by the 5% hydrated silica-gel column (82% and 91%) were higher than conventional sulfuric acid treatment (2.0% and 3.5%). The method detection limits of OH-PCBs for each matrix obtained by GC/ECNI-MS and GC/EI-HRMS were 0.58-2.6 pg g(-1) and 0.36-1.6 pg g(-1) wet wt, respectively. Recovery rates of OH-PCB congeners in spike tests using sample matrices (10 and 50 pg) were 64.7-117% (CV: 4.7-14%) and 70.4-120% (CV: 2.3-12%), respectively. This analytical method may enable the simultaneous detection of various OH-PCBs from complex tissue matrices. Furthermore, this method allows more comprehensive assessment of the biological effects of OH-PCB exposure on critical organs.


Analytical Sciences | 2015

Screening of phthalates in polymer materials by pyrolysis GC/MS.

Fumitaka Maruyama; Shigehiko Fujimaki; Yuki Sakamoto; Yukihiko Kudo; Haruhiko Miyagawa

A study on the rapid identification of phthalates in polymer materials has been conducted by employing gas chromatography-mass spectrometry coupled with a pyrolyzer (Py-GC/MS). Since Py-GC/MS does not require any complex solvent-extraction process, a rapid screening of phthalates should be possible. In this study, polymer samples were directly introduced into the pyrolyzer in order to thermally extract phthalates from the polymer under specific heating conditions. By optimizing the Py-GC/MS parameters, a sequential testing cycle of 35 min per sample was feasible without causing any major decomposition of the base materials. Thus, a rapid screening of over 20 samples per day was achieved without any time constraints by effectively utilizing specifically prepared reference polymer sheets for quality control. Py-GC/MS was found to be suitable and effective for identifying phthalates in polymer materials.


Molecules | 2018

Simultaneous Screening of Major Flame Retardants and Plasticizers in Polymer Materials Using Pyrolyzer/Thermal Desorption Gas Chromatography Mass Spectrometry (Py/TD–GC–MS)

Hiroyuki Yanagisawa; Yukihiko Kudo; Katsuhiro Nakagawa; Haruhiko Miyagawa; Fumitaka Maruyama; Shigehiko Fujimaki

This study was conducted with the aim of achieving the simultaneous screening of various additives in polymer materials by utilizing a solvent-free pyrolyzer/thermal desorption gas chromatography mass spectrometry (Py/TD-GC–MS) method. As a first step to achieve this goal, simultaneous screening has been examined by selecting major substances representing plasticizers and flame retardants, such as short chain chlorinated paraffins (SCCPs), decabromodiphenyl ether (DecaBDE), hexabromocyclododecane (HBCDD), and di(2-ethylhexyl) phthalate (DEHP). A quantitative MS analysis was performed to check for the peak areas and sensitivities. Since Py/TD-GC–MS is fraught with the risk of thermal degradation of the sample, temperatures during the analytical process were finely tuned for securing reliable results. The instrumental sensitivity was confirmed by the S/N ratio on each component. The detection limits of all components were less than 50 mg/kg, which are sufficiently lower than the regulatory criteria. With regard to reproducibility, a relative standard deviation (RSD) of about 5% was confirmed by employing a spike recovery test on a polystyrene polymer solution containing mixed standard solution (ca. 1000 mg/kg). In conclusion, the results obtained in this study indicate that Py/TD-GC–MS is applicable for the screening of major flame retardants and plasticizers in real samples with sufficient reproducibility at regulatory levels.


Archive | 2006

Gas chromatography/mass spectrometry system

Haruhiko Miyagawa


Archive | 1998

Method and apparatus in gas chromatography for introducing a sample

Kiyoshi Sugimoto; Haruhiko Miyagawa; Katsuhiro Nakagawa


Archive | 1993

MS/MS-TYPE MASS SPECTROMETER

Megumi Hirooka; Haruhiko Miyagawa; Atsushi Nagata; Yasufumi Tanaka; Yoshitake Yamamoto; 治彦 宮川; 善丈 山本; 恵 廣岡; 淳 永田; 靖文 田中


Chromatographia | 2011

Reproducibility of Programmed-Temperature Retention Indices under Average Linear Velocity Carrier Gas Control of GC and GC–MS

Haruhiko Miyagawa; Katsuhiro Nakagawa; Kiwao Kadokami


Lc Gc North America | 2007

Multiresidue pesticides analysis using synchronous scan/SIM mode GC-MS

Melissa Waller; Richard Whitney; Mark Taylor; Haruhiko Miyagawa; Keisuke Matsuda; Katsuhiro Nakagawa


Archive | 2006

CHROMATOGRAPHIC MASS SPECTROMETER

Haruhiko Miyagawa

Collaboration


Dive into the Haruhiko Miyagawa's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kiwao Kadokami

University of Kitakyushu

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge