Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Heesuk Shin is active.

Publication


Featured researches published by Heesuk Shin.


Annals of Rehabilitation Medicine | 2013

The Effect of Extracorporeal Shock Wave Therapy on Lower Limb Spasticity in Subacute Stroke Patients

Seung Won Moon; Jin Hoan Kim; Mi Jin Jung; Seungnam Son; Joong Hoon Lee; Heesuk Shin; Eun Shin Lee; Chul Ho Yoon; Min-Kyun Oh

Objective To evaluate the effect of extracorporeal shock wave therapy (ESWT) on lower limb spasticity in subacute stroke patients. Methods We studied thirty hemiplegic subacute stroke patients with ankle plantar flexor spasticity. ESWT was applied for 1 session/week, with a total of 3 sessions at the musculotendinous junction of medial and lateral gastrocnemius muscles. Patients were evaluated both clinically and biomechanically at baseline, after sham stimulation, and at immediately 1 week and 4 weeks after ESWT. For clinical assessment, Modified Ashworth Scale (MAS), clonus score, passive range of motion of ankle, and Fugl-Myer Assessment for the lower extremity were used. A biomechanical assessment of spasticity was conducted by an isokinetic dynamometer. Two parameters, peak eccentric torque (PET) and torque threshold angle (TTA), were analyzed at the velocities of 60°/sec, 180°/sec, and 240°/sec. Results After sham stimulation, there were no significant changes between each assessment. MAS and PET (180°/sec and 240°/sec) were significantly improved immediately and 1 week after ESWT. However, these changes were not significant at 4 weeks after ESWT. PET (60°/sec) and TTA (60°/sec, 180°/sec, and 240°/sec) were significantly improved immediately after ESWT. Yet, these changes were not significant at 1 week and 4 weeks after ESWT as well. Conclusion Lower limb spasticity in subacute stroke patients was significantly improved immediately after ESWT. Although the therapeutic effect of ESWT reduced with time and therefore was not significant at 4 weeks after ESWT, the degree of spasticity was lower than that of the baseline. Future studies with a larger sample of patients are warranted in order to verify the protocols which can optimize the effect of ESWT on spasticity.


Annals of Rehabilitation Medicine | 2013

Medial Antebrachial Cutaneous Nerve Injury After Brachial Plexus Block: Two Case Reports

Mi Jin Jung; Ha Young Byun; Chang Hee Lee; Seung Won Moon; Min-Kyun Oh; Heesuk Shin

Medial antebrachial cutaneous (MABC) nerve injury associated with iatrogenic causes has been rarely reported. Local anesthesia may be implicated in the etiology of such injury, but has not been reported. Two patients with numbness and painful paresthesia over the medial aspect of the unilateral forearm were referred for electrodiagnostic study, which revealed MABC nerve lesion in each case. The highly selective nature of the MABC nerve injuries strongly suggested that they were the result of direct nerve injury by an injection needle during previous brachial plexus block procedures. Electrodiagnostic studies can be helpful in evaluating cases of sensory disturbance after local anesthesia. To our knowledge, these are the first documented cases of isolated MABC nerve injury following ultrasound-guided axillary brachial plexus block.


Annals of Rehabilitation Medicine | 2012

Reliability of the Pinch Strength with Digitalized Pinch Dynamometer

Heesuk Shin; Seung Won Moon; Gab-Soon Kim; Jung Dong Park; Jin Hoan Kim; Mi Jin Jung; Chul Ho Yoon; Eun Shin Lee; Min-Kyun Oh

Objective To examine the intra-rater, inter-rater, and inter-instrumental reliability of the digitalized pinch muscle strength dynamometer. Method Thirty normal subjects were examined for pinch strength, using both the Preston pinch gauge and the digitalized pinch dynamometer. The participants performed all pinch strength tests in the seated position as recommended by the American Society of Hand Therapists (ASHT). Three successive measurements were taken for each hand. The mean of the three trials was used for data analysis. The pinch strength tests performed used a repeated measure design and measurements were taken by each rater. Results The relationship between the Preston pinch gauge and the digitalized pinch dynamometer in pinch strength was reliable (the ICC were 0.821 and 0.785 in rater 1 and rater 2 respectively). The relationship between the first session and second session in pinch strength using the digitalized pinch dynamometer was reliable (the ICC were 0.872 and 0.886 in rater A and rater B respectively). The relationship between rater A and rater B in pinch strength using the digitalized pinch dynamometer was reliable (the ICC was 0.754). Conclusion The pinch strength measurement using the digitalized pinch dynamometer is reliable within the rater and between raters. Thus, the Preston pinch gauge and the digitalized dynamometer measure grip strength equivalently, and can be used interchangeably.


Journal of Institute of Control, Robotics and Systems | 2010

Development of Force Measuring System using Three-axis Force Sensor for Measuring Two-finger Force

Hyeon-Min Kim; Jongwon Yoon; Heesuk Shin; Gab-Soon Kim

Stroke patients can`t use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers (thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). But, at present, the grasping finger force of two-finger can`t be accurately measured, because there is not a proper finger-force measuring system. Therefore, doctors can`t correctly judge the rehabilitating extent. So, the finger-force measuring system which can measure the grasping force of two-finger must be developed. In this paper, the finger-force measuring system with a three-axis force sensor which can measure the pressing force was developed. The three-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (Digital Signal Processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods.


Journal of Korean Medical Science | 2012

Korean Brain Rehabilitation Registry for Rehabilitation of Persons with Brain Disorders: Annual Report in 2009

Seung Nam Yang; Si Woon Park; Han Young Jung; Ueon Woo Rah; Yun Hee Kim; Min Ho Chun; Nam Jong Paik; Seung Don Yoo; Sung Bom Pyun; Min Wook Kim; Sam Gyu Lee; Byung Kyu Park; Heesuk Shin; Yong Il Shin; Heeyeon Lee; Tai Ryoon Han

This first annual report provides a description of patients discharged from rehabilitation facilities in Korea based on secondary data analysis of Korean Brain Rehabilitation Registry V1.0 subscribed in 2009. The analysis included 1,697 records of patients with brain disorders including stroke, traumatic brain injury, brain tumor and other disorders from 24 rehabilitation facilities across Korea. The data comprised 1,380 cases of stroke, 104 cases of brain injury, 55 cases of brain tumor, and 58 cases of other brain diseases. The functional status of each patient was measured using the Korean version of the Modified Barthel Index (KMBI). The average change in the KMBI score was 15.9 for all patients in the inpatient rehabilitation facility. The average length of stay for inpatient rehabilitation was 36.9 days. The transfer rates to other hospitals were high, being 62.4% when all patients were considered. Patients with brain disorders of Korea in 2009 and measurable functional improvement was observed in patients. However, relatively high percentages of patients were not discharged to the community after inpatient rehabilitation. Based on the results of this study, consecutive reports of the status of rehabilitation need to be conducted in order to provide useful information to many practitioners.


Annals of Rehabilitation Medicine | 2016

The Availability of Radiological Measurement of Femoral Anteversion Angle: Three-Dimensional Computed Tomography Reconstruction

Ha Young Byun; Heesuk Shin; Eun Shin Lee; Min Sik Kong; Seung Hun Lee; Chang Hee Lee

Objective To assess the intra-rater and inter-rater reliability for measuring femoral anteversion angle (FAA) by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT). Methods The study included 82 children who presented with intoeing gait. 3D-CT data taken between 2006 and 2014 were retrospectively reviewed. FAA was measured by 3D-CT. FAA is defined as the angle between the long axis of the femur neck and condylar axis of the distal femur. FAA measurement was performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coefficient (ICC). Results One hundred and sixty-four lower limbs of 82 children (31 boys and 51 girls, 6.3±3.2 years old) were included. The ICCs of intra-rater measurement for the angle of femoral neck axis (NA) were 0.89 for rater A and 0.96 for rater B, and those of condylar axis (CA) were 0.99 for rater A and 0.99 for rater B, respectively. The ICC of inter-rater measurement for the angle of NA was 0.89 and that of CA was 0.92. By each rater, the ICCs of the intrarater measurement for FAA were 0.97 for rater A and 0.95 for rater B, respectively and the ICC of the inter-rater measurement for FAA was 0.89. Conclusion The 3D-CT measures for FAA are reliable within individual raters and between different raters. The 3D-CT measures of FAA can be a useful method for accurate diagnosis and follow-up of femoral anteversion.


Annals of Rehabilitation Medicine | 2014

Retrospective Assessment of the Implementation of Critical Pathway in Stroke Patients in a Single University Hospital

Jin Hoan Kim; Ha Young Byun; Seungnam Son; Joong Hoon Lee; Chul Ho Yoon; Eun Shin Lee; Heesuk Shin; Min Kyun Oh

Objective To evaluate the effects of the implementation of critical pathway (CP) in stroke patients treated at a single university hospital. Methods A retrospective medical review collected data from 497 patients who had suffered acute stroke in the rehabilitation center. Stroke outcomes were compared between before and after the implementation of CP based on factors including demographic factors, stroke characteristics, pre-existing medical conditions, medical complications, functional states, and length of stay (LOS). Results After the implementation of CP, the patients showed significantly higher stage for upper proximal (p=0.008) and lower extremity (p=0.001) on Brunnstrom stage and significantly lower scores for modified Rankin Scale (p=0.003) at transfer. For those with pre-existing medical conditions, there were significantly increased osteoarthritis (p=0.002) and valvular heart disease (p=0.011). Regarding medical complications during acute inpatient rehabilitation, there were significantly decreased shoulder pain (p=0.001) and dysphagia (p=0.017), and significantly increased gastrointestinal symptoms (p=0.001). Functional gain and efficiency of stroke patients during rehabilitation center hospitalization did not significantly change after implementation of CP. But, shorter LOS of total hospitalization, pre-rehabilitation center hospitalization, and rehabilitation center hospitalization were evident. Conclusion After the implementation of CP, patients less often developed complications and displayed no changes in functional gain and efficiency. They had shorter LOS of total hospitalization, pre-rehabilitation center hospitalization and rehabilitation center hospitalization.


Annals of Rehabilitation Medicine | 2018

Change of Femoral Anteversion Angle in Children With Intoeing Gait Measured by Three-Dimensional Computed Tomography Reconstruction: One-Year Follow-Up Study

Minsik Kong; Hongsik Jo; Chang Han Lee; Se-Woong Chun; Chul-Ho Yoon; Heesuk Shin

Objective To evaluate femoral anteversion angle (FAA) change in children with intoeing gait depending on age, gender, and initial FAA using three-dimensional computed tomography (3D-CT). Methods The 3D-CT data acquired between 2006 and 2016 were retrospectively reviewed. Children 4 to 10 years of age with symptomatic intoeing gait with follow-up interval of at least 1 year without active treatment were enrolled. Subjects were divided into three groups based on age: group 1 (≥4 and <6 years), group 2 (≥6 and <8 years), and group 3 (≥8 and <10 years). Initial and follow-up FAAs were measured using 3D-CT. Mean changes in FAAs were calculated and compared. Results A total of 200 lower limbs of 100 children (48 males and 52 females, mean age of 6.1±1.6 years) were included. The mean follow-up period was 18.0±5.4 months. Average initial and follow-up FAA in children with intoeing gait was 31.1°±7.8° and 28.9°±8.2°, respectively. The initial FAA of group 1 was largest (33.5°±7.7°). Follow-up FAA of group 1 was significantly reduced to 28.7°±9.2° (p=0.000). FAA changes in groups 1, 2, and 3 were −6.5°±5.8°, −6.4°±5.1°, and −5.3°±4.0°, respectively. These changes of FAA were not significantly (p=0.355) different among the three age groups. However, FAA changes were higher (p=0.012) in females than those in males. In addition, FAA changes showed difference depending on initial FAA. When initial FAA was smaller than 30°, mean FAA change was −5.6°±4.9°. When initial FAA was more than 30°, mean FAA change was −6.8°±5.4° (p=0.019). Conclusion FAA initial in children with intoeing gait was the greatest in age group 1 (4–6 years). This group also showed significant FAA decrease at follow-up. FAA changes were greater when the child was a female, younger, and had greater initial FAA.


Annals of Rehabilitation Medicine | 2017

Collet-Sicard Syndrome With Hypoglossal Nerve Schwannoma: A Case Report

Seung Hun Lee; Eun Shin Lee; Chul Ho Yoon; Heesuk Shin; Chang Han Lee

Collet-Sicard syndrome is a rare syndrome that involves paralysis of 9th to 12th cranial nerves. We report an uncommon case of schwannoma of the hypoglossal nerve in a 39-year-old woman presented with slurred speech, hoarse voice, and swallowing difficulty. Physical examination revealed decreased gag reflex on the right side, decreased laryngeal elevation, tongue deviation to the right side, and weakness of right trapezius muscle. MRI revealed a mass lesion in the right parapharyngeal space below the jugular foramen. The tumor was surgically removed. It was confirmed as hypoglossal nerve schwannoma via pathologic examination. Videofluoroscopic swallowing study revealed aspiration of liquid food and severe bolus retention in the vallecula and piriform sinus. Laryngoscopy revealed right vocal cord palsy. Electrodiagnostic study revealed paralysis of the right 11th cranial nerve. In summary, we report an uncommon case of schwannoma of the hypoglossal nerve with 9th to 12th cranial nerve palsy presenting as Collet-Sicard syndrome.


Annals of Rehabilitation Medicine | 2016

Ureteral Rupture Caused by a Suprapubic Catheter in a Male Patient With Spinal Cord Injury: A Case Report

Hye Jung Choi; Chang Han Lee; Heesuk Shin

Spinal cord injury (SCI) may lead to urinary system disturbances. Patients with SCI usually have neurogenic bladder, and treatment optionss for this condition include clean intermittent catheterization and a permanent indwelling urethral or suprapubic catheter. Complications of catheterization include urinary tract infection, calculi, urinary tract injury, bladder contraction, bladder spasm, renal dysfunction, bladder cancer, and so forth. To the best of our knowledge, ureteral rupture is an unusual complication of catheterization, and ureteral rupture has been rarely reported in SCI patients. Therefore, here we report a case of ureteral rupture caused by a suprapubic catheter used for the treatment of neurogenic bladder with vesicoureteral reflux in a male patient with SCI. Due to SCI with neurogenic bladder, ureteral size can be reduced and the suprapubic catheter tip can easily migrate to the distal ureteral orifice. Thus, careful attention is required when a catheter is inserted into the bladder in patients with SCI.

Collaboration


Dive into the Heesuk Shin's collaboration.

Top Co-Authors

Avatar

Eun Shin Lee

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Min-Kyun Oh

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Chul Ho Yoon

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Chul-Ho Yoon

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Gab-Soon Kim

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Chang Han Lee

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Ha Young Byun

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Hyeon-Min Kim

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Jin Hoan Kim

Gyeongsang National University

View shared research outputs
Top Co-Authors

Avatar

Joong Hoon Lee

Gyeongsang National University

View shared research outputs
Researchain Logo
Decentralizing Knowledge