Circulation | 1996

Marked Inflammatory Sequelae to Implantation of Biodegradable and Nonbiodegradable Polymers in Porcine Coronary Arteries

Willem J. van der Giessen; A. Michael Lincoff; Robert S. Schwartz; Heleen M.M. van Beusekom; Patrick W. Serruys; David R. Holmes; Stephen G. Ellis; Eric J. Topol

BACKGROUND With the thrombogenic tendency and permanent implant nature of metallic stents, synthetic polymers have been proposed as candidate materials for stents and local drug delivery designs. We investigated the biocompatibility of several synthetic polymers after experimental placement in the coronary artery. METHODS AND RESULTS Five different biodegradable polymers (polyglycolic acid/polylactic acid [PGLA], polycaprolactone [PCL], polyhydroxybutyrate valerate [PHBV], polyorthoester [POE], and polyethyleneoxide/polybutylene terephthalate [PEO/ PBTP]) and three nonbiodegradable polymers (polyurethane [PUR], silicone [SIL], and polyethylene terephthalate [PETP]) were tested as strips deployed longitudinally across 90 degrees of the circumferential surface of coil wire stents. Appropriately sized polymer-loaded stents were implanted in porcine coronary arteries of 2.5- to 3.0-mm diameter. Four weeks after implantation, stent patency was assessed by angiography followed by microscopic examination of the coronary arteries. The biodegradable PCL, PHBV, and POE and the nonbiodegradable PUR and SIL evoked extensive inflammatory responses and fibrocellular proliferation (thickness of tissue response: 0.79 +/- 0.22, 1.12 +/- 0.01, 2.36 +/- 0.60, 1.24 +/- 0.36, and 1.43 +/- 0.15 mm, respectively). Less but still severe responses were observed for the biodegradable PGLA and PEO/PBTP (0.46 +/- 0.18 and 0.61 +/- 0.23 mm, respectively) and for the nonbiodegradable PETP (0.46 +/- 0.11 mm). CONCLUSIONS An array of both biodegradable and nonbiodegradable polymers has been demonstrated to induce a marked inflammatory reaction within the coronary artery with subsequent neointimal thickening, which was not expected on the basis of in vitro tests. The observed tissue response may be attributable to a combination of parent polymer compound, biodegradation products, and possibly implant geometry.


Journal of the American College of Cardiology | 2012

Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation.

Guillermo J. Tearney; Evelyn Regar; Takashi Akasaka; Tom Adriaenssens; Hiram G. Bezerra; Brett E. Bouma; Nico Bruining; Jin-man Cho; Saqib Chowdhary; Marco A. Costa; Ranil de Silva; Jouke Dijkstra; Carlo Di Mario; Darius Dudeck; Erlin Falk; Marc D. Feldman; Peter J. Fitzgerald; Hector Garcia Garcia; Nieves Gonzalo; Juan F. Granada; Giulio Guagliumi; Niels R. Holm; Yasuhiro Honda; Fumiaki Ikeno; Masanori Kawasaki; Janusz Kochman; Lukasz Koltowski; Takashi Kubo; Teruyoshi Kume; Hiroyuki Kyono

OBJECTIVES The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. BACKGROUND Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ~10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. METHODS The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. RESULTS Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. CONCLUSIONS This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data.


American Heart Journal | 2009

Optical coherence tomography patterns of stent restenosis

Nieves Gonzalo; Patrick W. Serruys; Takayuki Okamura; Heleen M.M. van Beusekom; Hector M. Garcia-Garcia; Gijs van Soest; Wim J. van der Giessen; Evelyn Regar

BACKGROUND Stent restenosis is an infrequent but poorly understood clinical problem in the drug-eluting stent era. The aim of the study was to evaluate the morphologic characteristics of stent restenosis by optical coherence tomography (OCT). METHODS Patients (n = 24, 25 vessels) presenting with angiographically documented stent restenosis were included. Quantitative OCT analysis consisted of lumen and stent area measurement and calculation of restenotic tissue area and burden. Qualitative restenotic tissue analysis included assessment of tissue structure, backscattering and symmetry, visible microvessels, lumen shape, and presence of intraluminal material. RESULTS By angiography, restenosis was classified as diffuse, focal, and at the margins in 9, 11, and 5 vessels, respectively. By OCT, restenotic tissue structure was layered in 52%, homogeneous in 28%, and heterogeneous in 20%. The predominant backscatter was high in 72%. Microvessels were visible in 12%. Lumen shape was irregular in 28% and there was intraluminal material in 20%. The mean restenotic tissue symmetry ratio was 0.58 +/- 0.19. Heterogeneous and low scattering restenotic tissue was more frequent in focal (45.5% and 54.5%, respectively) than in diffuse (0 and 11.1%) and margin restenosis (0 and 0%) (P = .005 for heterogeneous, P = .03 for low scattering). Restenosis patients with unstable angina symptoms presented more frequently irregular lumen shape (60 vs 6.7%, P = .007). Stents implanted </=12 months ago had more frequently restenotic tissue with layered appearance (84.6% vs 16.7%, P = .003). CONCLUSIONS We demonstrate the ability of OCT to identify differential patterns of restenotic tissue after stenting. This information could help in understanding the mechanism of stent restenosis.


Circulation | 1996

Reduction in Thrombotic Events With Heparin-Coated Palmaz-Schatz Stents in Normal Porcine Coronary Arteries.

Peter A. Hårdhammar; Heleen M.M. van Beusekom; H. Emanuelsson; Sjoerd H. Hofma; Per A. Albertsson; Pieter D. Verdouw; Eric Boersma; Patrick W. Serruys; Willem J. van der Giessen

BACKGROUND The use of stents improves the result after balloon coronary angioplasty. Thrombogenicity of stents is, however, a concern. In the present study, we compared stents with an antithrombotic coating with regular stents. METHODS AND RESULTS Regular stents were placed in coronary arteries of pigs receiving no aspirin (group 1; n = 8) or aspirin over 4 weeks (group 2, n = 10) or 12 weeks (group 3, n = 9). Stents coated with heparin (antithrombin III uptake, 5 pmol/stent) were placed in 7 pigs that did not receive aspirin (group 4). The other animals received aspirin and coated stents with a heparin activity of 12 pmol antithrombin III/stent (group 5, n = 10) or 20 pmol/stent (group 6, n = 10; group 7, n = 10). Quantitative arteriography was performed at implantation and after 4 (groups 1, 2, and 4 through 6) or 12 weeks (groups 3 and 7). In an additional 5 animals, five regular and five coated stents (20 pmol/stent) were placed and explanted after 5 days for examination of the early responses to the implants. Thrombotic occlusion of the regular stent occurred in 9 of 27 in groups 1 through 3. However, in 0 of 30 of the animals receiving high-activity heparin-coated stents (groups 5 through 7), thrombotic stent occlusion was observed (P < .001). Histological analysis at 4 weeks showed that the neointima in group 6 was thicker compared with its control group 2 (259 +/- 104 and 117 +/- 36 microns, P < .01), but at 12 weeks the thickness was similar (152 +/- 61 and 198 +/- 49 microns, respectively). Comparison at 5 days suggested delayed endothelialization of the coating. CONCLUSIONS High-activity heparin coating of stents eliminates subacute thrombosis in porcine coronary arteries.


Journal of Biomechanics | 2000

Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution.

Jolanda J. Wentzel; Deirdre M. Whelan; Willem J. van der Giessen; Heleen M.M. van Beusekom; Ivan Andhyiswara; Patrick W. Serruys; Cornelis J. Slager; Rob Krams

Mechanisms of in-stent restenosis are not fully understood. Shear stress is known to play a role in plaque and thrombus formation and is sensitive to changes in regional vessel geometry. Hence, we evaluated the regional changes in 3-D geometry and shear stress induced by stent placement in coronary arteries of pigs.Methods. 3-D reconstruction was performed, applying a combined angiographic and IVUS technique (ANGUS), from seven Wallstents (diameter 3.5 (n=3) and 5mm (n=4)), which were implanted in seven coronary arteries of five pigs. This 3-D geometry was used to calculate locally the curvature, while the shear stress distribution was obtained by computational fluid dynamics. Local changes in shear stress were obtained at the entrance and exit of the stent for baseline (0. 65+/-0.22 ml/s) and hyperemic flow (2.60+/-0.86 ml/s) conditions. Results. After stent implantation, the curvature increased by 121% at the entrance and by 100% at the exit of the stent, resulting in local changes in shear stress. In general, at the entrance of the stent local maxima in shear stress were generated, while at the exit both local maxima and minima in shear stress were observed (p<0.05). Additionally, the shear stress at the entrance and exit of the stent were correlated with the local curvature (r: 0.30-0.84).Conclusion. Stent implantation changes 3-D vessel geometry in such a way that regions with decreased and increased shear stress occur close to the stent edges. These changes might be related to the asymmetric patterns of in-stent restenosis.


Journal of the American College of Cardiology | 1993

Histology after stenting of human saphenous vein bypass grafts: Observations from surgically excised grafts 3 to 320 days after stent implantation☆

Heleen M.M. van Beusekom; Willem J. van der Giessen; Robert J. van Suylen; Egbert Bos; FréT. Bosman; Patrick W. Serruys

OBJECTIVES To gain insight into the mechanism of stenting in humans and its short- and long-term implications, we studied the vascular wall of saphenous vein aortocoronary bypass grafts after implantation of the Wallstent. BACKGROUND The implantation of a stent in aortocoronary bypass grafts may provide an alternative solution for revascularization in patients who are poor candidates for reoperation. Because human histopathologic findings after stenting with the Wallstent have not previously been described in detail, we examined graft segments that were surgically retrieved from 10 patients (21 stents) at 3 days to 10 months after implantation of the stent. METHODS The grafts were examined by a combination of the following techniques: light microscopy, immunocytochemistry and both scanning and transmission electron microscopy. RESULTS Early observations revealed that large amounts of platelets and leukocytes adhered to the stent wires during the first few days. At 3 months, the wires were embedded in a layered new intimal thickening, consisting of smooth muscle cells in a collagenous matrix. In addition, foam cells were abundant near the wires. Extracellular lipids and cholesterol crystals were found after 6 months. Smooth muscle cells and extracellular matrix formed the predominant component of restenosis. This new intimal thickening was lined with endothelium, in some cases showing defect intercellular junctions and abnormal adherence of leukocytes and platelets as late as 10 months after implantation. CONCLUSIONS This type of stent is potentially thrombogenic and seems to be associated with extracellular lipid accumulation in venous aortocoronary bypass grafts.


Optics Letters | 2011

Intravascular photoacoustic imaging of human coronary atherosclerosis.

Krista Jansen; Ton van der Steen; Heleen M.M. van Beusekom; Wolter Oosterhuis; Gijs van Soest

We demonstrate intravascular photoacoustic imaging of human coronary atherosclerotic plaque. The data was obtained from two fresh human coronary arteries ex vivo, showing different stages of disease. A 1.25 mm diameter intravascular imaging catheter was built, comprising an angle-polished optical fiber adjacent to a 30 MHz ultrasound transducer. Specific photoacoustic imaging of lipid content, a key factor in vulnerable plaques that may lead to myocardial infarction, is achieved by spectroscopic imaging at different wavelengths between 1180 and 1230 nm. Simultaneous imaging with intravascular ultrasound was performed.


Journal of the American College of Cardiology | 1998

Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries

Heleen M.M. van Beusekom; Deirdre M. Whelan; Sjoerd H. Hofma; Stefan C. Krabbendam; Victor W.M. van Hinsbergh; Pieter D. Verdouw; Willem J. van der Giessen

OBJECTIVE To compare percutaneous transluminal coronary angioplasty (PTCA) and stent implantation with respect to the long-term changes they induce in the newly formed endothelium in porcine coronary arteries by studying both morphological and functional parameters of the endothelium at 2 weeks and 3 months after intervention. BACKGROUND Problems affecting PTCA or stent implantation have been overcome to a large extent by means of better techniques and the availability of new drugs. Late problems, however, still exist in that restenosis affects a large number of patients. With an increasing number of patients being treated with stents, the problem of in-stent restenosis is of even greater concern, as this seems difficult to treat. A functional endothelial lining is thought to be important in controlling the growth of the underlying vascular tissue. We hypothesized that the enhanced neointimal hyperplasia observed after stenting is associated with a more pronounced and prolonged endothelial dysfunction. METHODS Arteries were analyzed using a dye-exclusion test and planimetry of permeable areas. Thereafter, the arteries were processed for light and scanning electron microscopy for assessment of morphology and proliferative response. RESULTS Leakage of the endothelium for molecules such as Evans blue-albumin as well as prolonged endothelial proliferation is observed as late as 3 months after the intervention, and is more pronounced after stenting. Permeability is associated with distinct morphologic characteristics: endothelial retraction, the expression of surface folds, and the adhesion of leukocytes. CONCLUSIONS Stenting especially decreases long-term vascular integrity with respect to permeability and endothelial proliferation, and is associated with distinct morphologic characteristics.


Journal of the American College of Cardiology | 1991

Stenting of coronary arteries: has a modern Pandora's box been opened?

Patrick W. Serruys; Bradley H. Strauss; Heleen M.M. van Beusekom; Willem J. van der Giessen

Interventional cardiology has recently witnessed the growth of several alternatives to percutaneous transluminal angioplasty, including coronary stenting. Although stenting appears to be useful in treating abrupt closure after coronary angioplasty, its effectiveness in limiting the complex processes responsible for late restenosis is much less certain. Pathologic examination of stented human saphenous bypass grafts shows extensive deposits of platelets, fibrin and leukocytes along the stent wires within the 1st week and formation of a neointima of variable thickness after 3 months without evidence of foreign body reaction. The long-term effects of continuous barotrauma induced by the expanded stent remain unknown. It is difficult to assess the relative merits of the new devices, but stenting has several theoretic advantages. It seems less disruptive to the underlying architecture of the vessel wall and enjoys favorable theoretic and effective expansion ratios. Wide-spread clinical acceptance for stenting will depend on demonstrating that its safety, efficacy and cost efficiency are superior to those of balloon angioplasty.


Circulation-cardiovascular Interventions | 2015

Angiographic and Optical Coherence Tomography Insights Into Bioresorbable Scaffold Thrombosis Single-Center Experience

Antonios Karanasos; Nicolas M. Van Mieghem; Nienke S. van Ditzhuijzen; Cordula Felix; Joost Daemen; Anouchska Autar; Yoshinobu Onuma; Mie Kurata; Roberto Diletti; Marco Valgimigli; Floris Kauer; Heleen M.M. van Beusekom; Peter de Jaegere; Felix Zijlstra; Robert-Jan van Geuns; Eveline Regar

Background—As bioresorbable vascular scaffolds (BVSs) are being increasingly used in complex real-world lesions and populations, BVS thrombosis cases have been reported. We present angiographic and optical coherence tomography (OCT) findings in a series of patients treated in our center for definite bioresorbable scaffold thrombosis. Methods and Results—Up to June 2014, 14 patients presented with definite BVS thrombosis in our center. OCT was performed in 9 patients at the operator’s discretion. Angiographic and OCT findings were compared with a control group comprising 15 patients with definite metallic stent thrombosis. In the BVS group, time interval from index procedure to scaffold thrombosis ranged from 0 to 675 days. Incomplete lesion coverage by angiography was identified in 4 of 14 cases, malapposition by OCT in 5 of 9 cases, strut discontinuity in 2 of 9 cases, and underexpansion in 2 of 9 cases. Five patients had discontinued dual antiplatelet therapy, and in 3 of them discontinued dual antiplatelet therapy discontinuation had occurred the week preceding the event. There were no significant differences in angiographic or OCT findings between BVS and metallic stent thrombosis. Conclusions—Suboptimal implantation with incomplete lesion coverage, underexpansion, and malapposition comprises the main pathomechanism for both early and late BVS thrombosis, similar to metallic stent thrombosis. Dual antiplatelet therapy discontinuation seems to also be a secondary contributor in several late events. Our observations suggest that several potential triggers for BVS thrombosis could be avoided.

Collaboration


Dive into the Heleen M.M. van Beusekom's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Patrick W. Serruys

University of Texas Health Science Center at Houston

View shared research outputs
Top Co-Authors

Avatar

Oana Sorop

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Dirk J. Duncker

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mieke van den Heuvel

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar

Gijs van Soest

Erasmus University Rotterdam

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge