Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Helen R. Murphy is active.

Publication


Featured researches published by Helen R. Murphy.


BMJ | 2011

Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies

Roman Hovorka; Kavita Kumareswaran; Julie Harris; Janet M. Allen; Daniela Elleri; Dongyuan Xing; Craig Kollman; Marianna Nodale; Helen R. Murphy; David B. Dunger; Stephanie A. Amiel; Simon Heller; Malgorzata E. Wilinska; Mark L. Evans

Objective To compare the safety and efficacy of overnight closed loop delivery of insulin (artificial pancreas) with conventional insulin pump therapy in adults with type 1 diabetes. Design Two sequential, open label, randomised controlled crossover, single centre studies. Setting Clinical research facility. Participants 24 adults (10 men, 14 women) with type 1 diabetes, aged 18-65, who had used insulin pump therapy for at least three months: 12 were tested after consuming a medium sized meal and the other 12 after consuming a larger meal accompanied by alcohol. Intervention During overnight closed loop delivery, sensor measurements of glucose were fed into a computer algorithm, which advised on insulin pump infusion rates at 15 minute intervals. During control nights, conventional insulin pump settings were applied. One study compared closed loop delivery of insulin with conventional pump therapy after a medium sized evening meal (60 g of carbohydrates) at 1900, depicting the scenario of “eating in.” The other study was carried out after a later large evening meal (100 g of carbohydrates) at 2030, accompanied by white wine (0.75 g/kg ethanol) and depicted the scenario of “eating out.” Main outcome measures The primary outcome was the time plasma glucose levels were in target (3.91-8.0 mmol/L) during closed loop delivery and a comparable control period. Secondary outcomes included pooled data analysis and time plasma glucose levels were below target (≤3.9 mmol/L). Results For the eating in scenario, overnight closed loop delivery of insulin increased the time plasma glucose levels were in target by a median 15% (interquartile range 3-35%), P=0.002. For the eating out scenario, closed loop delivery increased the time plasma glucose levels were in target by a median 28% (2-39%), P=0.01. Analysis of pooled data showed that the overall time plasma glucose was in target increased by a median 22% (3-37%) with closed loop delivery (P<0.001). Closed loop delivery reduced overnight time spent hypoglycaemic (plasma glucose ≤3.9 mmol/L) by a median 3% (0-20%), P=0.04, and eliminated plasma glucose concentrations below 3.0 mmol/L after midnight. Conclusion These two small crossover trials suggest that closed loop delivery of insulin may improve overnight control of glucose levels and reduce the risk of nocturnal hypoglycaemia in adults with type 1 diabetes. Trial registration ClinicalTrials.gov NCT00910767 and NCT00944619.


BMJ | 2008

Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial

Helen R. Murphy; Gerry Rayman; Karen Lewis; Susan Kelly; Balroop Johal; Katherine Duffield; Duncan Fowler; Peter J. Campbell; Rosemary C. Temple

Objective To evaluate the effectiveness of continuous glucose monitoring during pregnancy on maternal glycaemic control, infant birth weight, and risk of macrosomia in women with type 1 and type 2 diabetes. Design Prospective, open label randomised controlled trial. Setting Two secondary care multidisciplinary obstetric clinics for diabetes in the United Kingdom. Participants 71 women with type 1 diabetes (n=46) or type 2 diabetes (n=25) allocated to antenatal care plus continuous glucose monitoring (n=38) or to standard antenatal care (n=33). Intervention Continuous glucose monitoring was used as an educational tool to inform shared decision making and future therapeutic changes at intervals of 4-6 weeks during pregnancy. All other aspects of antenatal care were equal between the groups. Main outcome measures The primary outcome was maternal glycaemic control during the second and third trimesters from measurements of HbA1c levels every four weeks. Secondary outcomes were birth weight and risk of macrosomia using birthweight standard deviation scores and customised birthweight centiles. Statistical analyses were done on an intention to treat basis. Results Women randomised to continuous glucose monitoring had lower mean HbA1c levels from 32 to 36 weeks’ gestation compared with women randomised to standard antenatal care: 5.8% (SD 0.6) v 6.4% (SD 0.7). Compared with infants of mothers in the control arm those of mothers in the intervention arm had decreased mean birthweight standard deviation scores (0.9 v 1.6; effect size 0.7 SD, 95% confidence interval 0.0 to 1.3), decreased median customised birthweight centiles (69% v 93%), and a reduced risk of macrosomia (odds ratio 0.36, 95% confidence interval 0.13 to 0.98). Conclusion Continuous glucose monitoring during pregnancy is associated with improved glycaemic control in the third trimester, lower birth weight, and reduced risk of macrosomia. Trial registration Current Controlled Trials ISRCTN84461581.


Diabetes Care | 2014

Overnight Closed-Loop Insulin Delivery in Young People With Type 1 Diabetes: A Free-Living, Randomized Clinical Trial

Roman Hovorka; Daniela Elleri; Hood Thabit; Janet Macdonald Allen; Lalantha Leelarathna; Ranna El-Khairi; Kavita Kumareswaran; Karen Caldwell; Peter Calhoun; Craig Kollman; Helen R. Murphy; Carlo L. Acerini; Malgorzata E Wilinska; Marianna Nodale; David B. Dunger

OBJECTIVE To evaluate feasibility, safety, and efficacy of overnight closed-loop insulin delivery in free-living youth with type 1 diabetes. RESEARCH DESIGN AND METHODS Overnight closed loop was evaluated at home by 16 pump-treated adolescents with type 1 diabetes aged 12–18 years. Over a 3-week period, overnight insulin delivery was directed by a closed-loop system, and on another 3-week period sensor-augmented therapy was applied. The order of interventions was random. The primary end point was time when adjusted sensor glucose was between 3.9 and 8.0 mmol/L from 2300 to 0700 h. RESULTS Closed loop was constantly applied over at least 4 h on 269 nights (80%); sensor data were collected over at least 4 h on 282 control nights (84%). Closed loop increased time spent with glucose in target by a median 15% (interquartile range −9 to 43; P < 0.001). Mean overnight glucose was reduced by a mean 14 (SD 58) mg/dL (P < 0.001). Time when glucose was <70 mg/dL was low in both groups, but nights with glucose <63 mg/dL for at least 20 min were less frequent during closed loop (10 vs. 17%; P = 0.01). Despite lower total daily insulin doses by a median 2.3 (interquartile range −4.7 to 9.3) units (P = 0.009), overall 24-h glucose was reduced by a mean 9 (SD 41) mg/dL (P = 0.006) during closed loop. CONCLUSIONS Unsupervised home use of overnight closed loop in adolescents with type 1 diabetes is safe and feasible. Glucose control was improved during the day and night with fewer episodes of nocturnal hypoglycemia.


Diabetic Medicine | 2006

Psycho-educational interventions for children and young people with Type 1 diabetes.

Helen R. Murphy; Gerry Rayman; Timothy Skinner

Background  A systematic review of the literature in 2000 revealed numerous methodological shortcomings in education research, but in recent years progress has been made in the quantity and quality of psycho‐educational intervention studies.


Diabetes Care | 2013

Closed-Loop Basal Insulin Delivery Over 36 Hours in Adolescents With Type 1 Diabetes: Randomized clinical trial

Daniela Elleri; Janet M. Allen; Kavita Kumareswaran; Lalantha Leelarathna; Marianna Nodale; Karen Caldwell; Peiyao Cheng; Craig Kollman; Ahmad Haidar; Helen R. Murphy; Malgorzata E. Wilinska; Carlo L. Acerini; David B. Dunger; Roman Hovorka

OBJECTIVE We evaluated the safety and efficacy of closed-loop basal insulin delivery during sleep and after regular meals and unannounced periods of exercise. RESEARCH DESIGN AND METHODS Twelve adolescents with type 1 diabetes (five males; mean age 15.0 [SD 1.4] years; HbA1c 7.9 [0.7]%; BMI 21.4 [2.6] kg/m2) were studied at a clinical research facility on two occasions and received, in random order, either closed-loop basal insulin delivery or conventional pump therapy for 36 h. During closed-loop insulin delivery, pump basal rates were adjusted every 15 min according to a model predictive control algorithm informed by subcutaneous sensor glucose levels. During control visits, subjects’ standard infusion rates were applied. Prandial insulin boluses were given before main meals (50–80 g carbohydrates) but not before snacks (15–30 g carbohydrates). Subjects undertook moderate-intensity exercise, not announced to the algorithm, on a stationary bicycle at a 140 bpm heart rate in the morning (40 min) and afternoon (20 min). Primary outcome was time when plasma glucose was in the target range (71–180 mg/dL). RESULTS Closed-loop basal insulin delivery increased percentage time when glucose was in the target range (median 84% [interquartile range 78–88%] vs. 49% [26–79%], P = 0.02) and reduced mean plasma glucose levels (128 [19] vs. 165 [55] mg/dL, P = 0.02). Plasma glucose levels were in the target range 100% of the time on 17 of 24 nights during closed-loop insulin delivery. Hypoglycemia occurred on 10 occasions during control visits and 9 occasions during closed-loop delivery (5 episodes were exercise related, and 4 occurred within 2.5 h of prandial bolus). CONCLUSIONS Day-and-night closed-loop basal insulin delivery can improve glucose control in adolescents. However, unannounced moderate-intensity exercise and excessive prandial boluses pose challenges to hypoglycemia-free closed-loop basal insulin delivery.


Diabetic Medicine | 2005

The pregnancies of women with Type 2 diabetes: poor outcomes but opportunities for improvement

Jonathan M Roland; Helen R. Murphy; V. Ball; J. Northcote-Wright; Rosemary C. Temple

Aim  To compare the outcomes of Type 1 and Type 2 diabetic pregnancies and identify risk factors for poor outcome of Type 2 pregnancies


Diabetes Care | 2010

Effectiveness of a Regional Prepregnancy Care Program in Women With Type 1 and Type 2 Diabetes: Benefits beyond glycemic control

Helen R. Murphy; Jonathan M Roland; Timothy Skinner; David Simmons; Eleanor Gurnell; Nicholas J Morrish; Shiu-Ching Soo; Suzannah Kelly; Boon Lim; Joanne Randall; Sarah Thompsett; Rosemary C. Temple

OBJECTIVE To implement and evaluate a regional prepregnancy care program in women with type 1 and type 2 diabetes. RESEARCH DESIGN AND METHODS Prepregnancy care was promoted among patients and health professionals and delivered across 10 regional maternity units. A prospective cohort study of 680 pregnancies in women with type 1 and type 2 diabetes was performed. Primary outcomes were adverse pregnancy outcome (congenital malformation, stillbirth, or neonatal death), congenital malformation, and indicators of pregnancy preparation (5 mg folic acid, gestational age, and A1C). Comparisons were made with a historical cohort (n = 613 pregnancies) from the same units during 1999–2004. RESULTS A total of 181 (27%) women attended, and 499 women (73%) did not attend prepregnancy care. Women with prepregnancy care presented earlier (6.7 vs. 7.7 weeks; P < 0.001), were more likely to take 5 mg preconception folic acid (88.2 vs. 26.7%; P < 0.0001) and had lower A1C levels (A1C 6.9 vs. 7.6%; P < 0.0001). They had fewer adverse pregnancy outcomes (1.3 vs. 7.8%; P = 0.009). Multivariate logistic regression confirmed that in addition to glycemic control, lack of prepregnancy care was independently associated with adverse outcome (odds ratio 0.2 [95% CI 0.05–0.89]; P = 0.03). Compared with 1999–2004, folic acid supplementation increased (40.7 vs. 32.5%; P = 0.006) and congenital malformations decreased (4.3 vs. 7.3%; P = 0.04). CONCLUSIONS Regional prepregnancy care was associated with improved pregnancy preparation and reduced risk of adverse pregnancy outcome in type 1 and type 2 diabetes. Prepregnancy care had benefits beyond improved glycemic control and was a stronger predictor of pregnancy outcome than maternal obesity, ethnicity, or social disadvantage.


Diabetes Care | 2011

Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes

Helen R. Murphy; Daniela Elleri; Janet M. Allen; Julie Harris; David Simmons; Gerry Rayman; Rosemary C. Temple; David B. Dunger; Ahmad Haidar; Marianna Nodale; Malgorzata E. Wilinska; Roman Hovorka

OBJECTIVE This study evaluated closed-loop insulin delivery with a model predictive control (MPC) algorithm during early (12–16 weeks) and late gestation (28–32 weeks) in pregnant women with type 1 diabetes. RESEARCH DESIGN AND METHODS Ten women with type 1 diabetes (age 31 years, diabetes duration 19 years, BMI 24.1 kg/m2, booking A1C 6.9%) were studied over 24 h during early (14.8 weeks) and late pregnancy (28.0 weeks). A nurse adjusted the basal insulin infusion rate from continuous glucose measurements (CGM), fed into the MPC algorithm every 15 min. Mean glucose and time spent in target (63–140 mg/dL), hyperglycemic (>140 to ≥180 mg/dL), and hypoglycemic (<63 to ≤50 mg/dL) were calculated using plasma and sensor glucose measurements. Linear mixed-effects models were used to compare glucose control during early and late gestation. RESULTS During closed-loop insulin delivery, median (interquartile range) plasma glucose levels were 117 (100.8–154.8) mg/dL in early and 126 (109.8–140.4) mg/dL in late gestation (P = 0.72). The overnight mean (interquartile range) plasma glucose time in target was 84% (50–100%) in early and 100% (94–100%) in late pregnancy (P = 0.09). Overnight mean (interquartile range) time spent hyperglycemic (>140 mg/dL) was 7% (0–40%) in early and 0% (0–6%) in late pregnancy (P = 0.25) and hypoglycemic (<63 mg/dL) was 0% (0–3%) and 0% (0–0%), respectively (P = 0.18). Postprandial glucose control, glucose variability, insulin infusion rates, and CGM sensor accuracy were no different in early or late pregnancy. CONCLUSIONS MPC algorithm performance was maintained throughout pregnancy, suggesting that overnight closed-loop insulin delivery could be used safely during pregnancy. More work is needed to achieve optimal postprandial glucose control.


Diabetes Care | 2011

Safety and Efficacy of 24-H Closed-Loop Insulin Delivery in Well-Controlled Pregnant Women With Type 1 Diabetes A randomized crossover case series

Helen R. Murphy; Kavita Kumareswaran; Daniela Elleri; Janet M. Allen; Karen Caldwell; Martina Biagioni; David Simmons; David B. Dunger; Marianna Nodale; Malgorzata E. Wilinska; Stephanie A. Amiel; Roman Hovorka

OBJECTIVE To evaluate the safety and efficacy of closed-loop insulin delivery in well-controlled pregnant women with type 1 diabetes treated with continuous subcutaneous insulin infusion (CSII). RESEARCH DESIGN AND METHODS A total of 12 women with type 1 diabetes (aged 32.9 years, diabetes duration 17.6 years, BMI 27.1 kg/m2, and HbA1c 6.4%) were randomly allocated to closed-loop or conventional CSII. They performed normal daily activities (standardized meals, snacks, and exercise) for 24 h on two occasions at 19 and 23 weeks’ gestation. Plasma glucose time in target (63–140 mg/dL) and time spent hypoglycemic were calculated. RESULTS Plasma glucose time in target was comparable for closed-loop and conventional CSII (median [interquartile range]: 81 [59–87] vs. 81% [54–90]; P = 0.75). Less time was spent hypoglycemic (<45 mg/dL [0.0 vs. 0.3%]; P = 0.04), with a lower low blood glucose index (2.4 [0.9–3.5] vs. 3.3 [1.9–5.1]; P = 0.03), during closed-loop insulin delivery. CONCLUSIONS Closed-loop insulin delivery was as effective as conventional CSII, with less time spent in extreme hypoglycemia.


Diabetes Care | 2017

International Consensus on Use of Continuous Glucose Monitoring

Thomas Danne; Revital Nimri; Tadej Battelino; Richard M. Bergenstal; Kelly L. Close; J. Hans DeVries; Satish K. Garg; Lutz Heinemann; Irl B. Hirsch; Stephanie A. Amiel; Roy W. Beck; Emanuele Bosi; Bruce Buckingham; Claudio Cobelli; Eyal Dassau; Francis J. Doyle; Simon Heller; Roman Hovorka; Weiping Jia; Timothy W. Jones; Olga Kordonouri; Boris P. Kovatchev; Aaron J. Kowalski; Lori Laffel; David M. Maahs; Helen R. Murphy; Kirsten Nørgaard; Christopher G. Parkin; Eric Renard; Banshi Saboo

Measurement of glycated hemoglobin (HbA1c) has been the traditional method for assessing glycemic control. However, it does not reflect intra- and interday glycemic excursions that may lead to acute events (such as hypoglycemia) or postprandial hyperglycemia, which have been linked to both microvascular and macrovascular complications. Continuous glucose monitoring (CGM), either from real-time use (rtCGM) or intermittently viewed (iCGM), addresses many of the limitations inherent in HbA1c testing and self-monitoring of blood glucose. Although both provide the means to move beyond the HbA1c measurement as the sole marker of glycemic control, standardized metrics for analyzing CGM data are lacking. Moreover, clear criteria for matching people with diabetes to the most appropriate glucose monitoring methodologies, as well as standardized advice about how best to use the new information they provide, have yet to be established. In February 2017, the Advanced Technologies & Treatments for Diabetes (ATTD) Congress convened an international panel of physicians, researchers, and individuals with diabetes who are expert in CGM technologies to address these issues. This article summarizes the ATTD consensus recommendations and represents the current understanding of how CGM results can affect outcomes.

Collaboration


Dive into the Helen R. Murphy's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Rosemary C. Temple

Norfolk and Norwich University Hospital

View shared research outputs
Top Co-Authors

Avatar

Gerry Rayman

University of Southampton

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge