Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hélène Eltchaninoff is active.

Publication


Featured researches published by Hélène Eltchaninoff.


Circulation | 2002

Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis First Human Case Description

Alain Cribier; Hélène Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Geneviève Derumeaux; Frédéric Anselme; François Laborde; Martin B. Leon

Background— The design of a percutaneous implantable prosthetic heart valve has become an important area for investigation. A percutaneously implanted heart valve (PHV) composed of 3 bovine pericardial leaflets mounted within a balloon-expandable stent was developed. After ex vivo testing and animal implantation studies, the first human implantation was performed in a 57-year-old man with calcific aortic stenosis, cardiogenic shock, subacute leg ischemia, and other associated noncardiac diseases. Valve replacement had been declined for this patient, and balloon valvuloplasty had been performed with nonsustained results. Methods and Results— With the use of an antegrade transseptal approach, the PHV was successfully implanted within the diseased native aortic valve, with accurate and stable PHV positioning, no impairment of the coronary artery blood flow or of the mitral valve function, and a mild paravalvular aortic regurgitation. Immediately and at 48 hours after implantation, valve function was excellent, resulting in marked hemodynamic improvement. Over a follow-up period of 4 months, the valvular function remained satisfactory as assessed by sequential transesophageal echocardiography, and there was no recurrence of heart failure. However, severe noncardiac complications occurred, including a progressive worsening of the leg ischemia, leading to leg amputation with lack of healing, infection, and death 17 weeks after PHV implantation. Conclusions— Nonsurgical implantation of a prosthetic heart valve can be successfully achieved with immediate and midterm hemodynamic and clinical improvement. After further device modifications, additional durability tests, and confirmatory clinical implantations, PHV might become an important therapeutic alternative for the treatment of selected patients with nonsurgical aortic stenosis.


The New England Journal of Medicine | 2012

Registry of transcatheter aortic-valve implantation in high-risk patients

Martine Gilard; Hélène Eltchaninoff; Bernard Iung; Patrick Donzeau-Gouge; Karine Chevreul; Jean Fajadet; Pascal Leprince; Alain Leguerrier; Michel Lievre; Alain Prat; Emmanuel Teiger; Thierry Lefèvre; Dominique Himbert; Didier Tchetche; Didier Carrié; Bernard Albat; Alain Cribier; Gilles Rioufol; Arnaud Sudre; Didier Blanchard; Frederic Collet; Pierre Dos Santos; Nicolas Meneveau; Ashok Tirouvanziam; Christophe Caussin; Philippe Guyon; Jacques Boschat; Frédéric Collart; Remi Houel; Stephane Delpine

BACKGROUND Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. METHODS All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. RESULTS A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (±SD) age was 82.7±7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. CONCLUSIONS This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.).


European Heart Journal | 2011

Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry

Hélène Eltchaninoff; Alain Prat; Martine Gilard; Alain Leguerrier; Didier Blanchard; Gerard Fournial; Bernard Iung; Patrick Donzeau-Gouge; Christophe Tribouilloy; Jean-Louis Debrux; Alain Pavie; Pascal Gueret

AIMS Transcatheter aortic valve implantation is a therapeutic alternative for high-surgical-risk patients with severe symptomatic aortic stenosis. Two models of prosthesis are currently commercialized in France, which can be implanted either via a transarterial or a transapical approach. The aim of the study was to evaluate in a national French registry the early safety and efficacy of transcatheter aortic valve replacement (AVR) using either the Edwards SAPIEN™ or CoreValve™ in high-surgical-risk patients with severe aortic stenosis. METHODS AND RESULTS The multicentre national registry was conducted in 16 centres between February 2009 and June 2009, under the authority of the French Societies of Cardiology and Thoracic and Cardio-Vascular Surgery. The primary endpoint was mortality at 1 month. Two hundred and forty-four high-surgical-risk patients (logistic EuroSCORE ≥20%, STS ≥10%, or contra-indication to AVR) were enrolled. Mean age was 82 ± 7 years and 43.9% were female. Edwards SAPIEN and CoreValve were implanted in 68 and 32% of patients, respectively. The approaches used were transarterial (transfemoral: 66%; subclavian: 5%) or transapical in 29%. Device success rate was 98.3% and 30-day mortality was 12.7%. Severe complications included stroke (3.6%), tamponade (2%), acute coronary occlusion (1.2%), and vascular complications (7.3%). Pacemaker was required in 11.8%. At 1 month, 88% of patients were in NYHA class II or less. CONCLUSION This prospective registry reflects the real-life experience of transcatheter aortic valve implantation in high-risk elderly patients in France. The early results are satisfactory in terms of feasibility, short-term haemodynamic and functional improvement, and safety. Longer term follow-up will be further assessed.


European Heart Journal | 2011

One year follow-up of the multi-centre European PARTNER transcatheter heart valve study

Thierry Lefèvre; Ari Pieter Kappetein; Ernst Wolner; Patrick Nataf; Martyn Thomas; Volker Schächinger; Bernard De Bruyne; Hélène Eltchaninoff; Matthias Thielmann; Dominique Himbert; Mauro Romano; Patrick W. Serruys; Gerhard Wimmer-Greinecker

Background Transcatheter aortic valve implantation (TAVI) has emerged as a new therapeutic option in high-risk patients with severe aortic stenosis. Aims PARTNER EU is the first study to evaluate prospectively the procedural and mid-term outcomes of transfemoral (TF) or transapical (TA) implantation of the Edwards SAPIEN® valve involving a multi-disciplinary approach. Methods and results Primary safety endpoints were 30 days and 6 months mortality. Primary efficacy endpoints were haemodynamic and functional improvement at 12 months. One hundred and thirty patients (61 TF, 69 TA), aged 82.1 ± 5.5 years were included. TA patients had higher logistic EuroSCORE (33.8 vs. 25.7%, P = 0.0005) and more peripheral disease (49.3 vs. 16.4%, P< 0.0001). Procedures were aborted in four TA (5.8%) and six TF cases (9.8%). Valve implantation was successful in the remaining patients in 95.4 and 96.4%, respectively. Thirty days and 6 months survival were 81.2 and 58.0% (TA) and 91.8 and 90.2% (TF). In both groups, mean aortic gradient decreased from 46.9 ± 18.1 to 10.9 ± 5.4 mmHg 6 months post-TAVI. In total, 78.1 and 84.8% of patients experienced significant improvement in New York Heart Association (NYHA) class, whereas 73.9 and 72.7% had improved Kansas City Cardiomyopathy Questionnaire (KCCQ) scores in TA and TF cohorts, respectively. Conclusion This first team-based multi-centre European TAVI registry shows promising results in high-risk patients treated by TF or TA delivery. Survival rates differ significantly between TF and TA groups and probably reflect the higher risk profile of the TA cohort. Optimal patient screening, approach selection, and device refinement may improve outcomes.


Circulation | 2008

Comparison of Thrombolysis Followed by Broad Use of Percutaneous Coronary Intervention With Primary Percutaneous Coronary Intervention for ST-Segment-Elevation Acute Myocardial Infarction : Data From the French Registry on Acute ST-Elevation Myocardial Infarction (FAST-MI)

Nicolas Danchin; Pierre Coste; Jean Ferrières; Philippe-Gabriel Steg; Yves Cottin; Didier Blanchard; Loic Belle; Bernard Ritz; Gilbert Kirkorian; Michael Angioi; Philippe Sans; Bernard Charbonnier; Hélène Eltchaninoff; Pascal Gueret; Khalife Khalife; Philippe Asseman; Jacques Puel; Patrick Goldstein; Jean-Pierre Cambou; Tabassome Simon

Background— Intravenous thrombolysis remains a widely used treatment for ST-elevation myocardial infarction; however, it carries a higher risk of reinfarction than primary PCI (PPCI). There are few data comparing PPCI with thrombolysis followed by routine angiography and PCI. The purpose of the present study was to assess contemporary outcomes in ST-elevation myocardial infarction patients, with specific emphasis on comparing a pharmacoinvasive strategy (thrombolysis followed by routine angiography) with PPCI. Methods and Results— This nationwide registry in France included 223 centers and 1714 patients over a 1-month period at the end of 2005, with 1-year follow-up. Sixty percent of the patients underwent reperfusion therapy, 33% with PPCI and 29% with intravenous thrombolysis (18% prehospital). At baseline, the Global Registry of Acute Coronary Events score was similar in thrombolysis and PPCI patients. Time to initiation of reperfusion therapy was significantly shorter in thrombolysis than in PPCI (median 130 versus 300 minutes). After thrombolysis, 96% of patients had coronary angiography, and 84% had subsequent PCI (58% within 24 hours). In-hospital mortality was 4.3% for thrombolysis and 5.0% for PPCI. In patients with thrombolysis, 30-day mortality was 9.2% when PCI was not used and 3.9% when PCI was subsequently performed (4.0% if PCI was performed in the same hospital and 3.3% if performed after transfer to another facility). One-year survival was 94% for thrombolysis and 92% for PPCI (P=0.31). After propensity score matching, 1-year survival was 94% and 93%, respectively. Conclusions— When used early after the onset of symptoms, a pharmacoinvasive strategy that combines thrombolysis with a liberal use of PCI yields early and 1-year survival rates that are comparable to those of PPCI.


Circulation | 2005

Maintenance of Long-Term Clinical Benefit With Sirolimus-Eluting Coronary Stents Three-Year Results of the RAVEL Trial

Jean Fajadet; Marie Claude Morice; Christoph Bode; Paul Barragan; Patrick W. Serruys; William Wijns; Constantino R. Constantini; Jean Léon Guermonprez; Hélène Eltchaninoff; Didier Blanchard; Antonio L. Bartorelli; Gert Jan Laarman; MarcoAntonio Perin; J. Eduardo Sousa; Gerhard Schuler; Ferenc Molnar; Giulio Guagliumi; Antonio Colombo; Ernesto Ban Hayashi; Egon Wülfert

Background—The use of sirolimus-eluting coronary stents has been associated with a nearly complete elimination of restenosis at 6 months and with a very low 1-year incidence of major adverse cardiac events (MACE). This analysis examined whether these beneficial effects persist over the longer term. Methods and Results—This multicenter trial randomly assigned 238 patients to revascularization of single, de novo, native coronary artery lesions with sirolimus-eluting versus conventional bare-metal stents. Survival free from target lesion revascularization (TLR), target vessel failure (TVF), and MACE up to 3 years of follow-up was compared between the 2 treatment groups. Complete data sets were available in 94.2% of patients treated with sirolimus-eluting stents and in 94.1% of patients randomized to the control group. The cumulative 1-, 2-, and 3-year event-free survival rates were 99.2%, 96.5%, and 93.7% for TLR and 95.8%, 92.3%, and 87.9% for TVF, respectively, in the sirolimus-eluting stent group, versus 75.9%, 75.9%, and 75.0% for TLR and 71.2%, 69.4%, and 67.3% for TVF in the control group (P<0.001 for both comparisons at 3 years). Rates of MACE at 3 years were 15.8% in patients randomly assigned to sirolimus-eluting stents versus 33.1% in patients assigned to bare-metal stents (P=0.002). One patient treated with a sirolimus-eluting stent died of a cardiac cause between 12 and 36 months. Conclusions—Treatment of de novo coronary stenosis with sirolimus-eluting stents was associated with a sustained clinical benefit and very low rates of TLR and of other MACE up to 3 years after device implantation.


Circulation | 2003

Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis

Alain Cribier; Hélène Eltchaninoff; Assaf Bash; Nicolas Borenstein; Christophe Tron; Fabrice Bauer; Geneviève Derumeaux; Frédéric Anselme; François Laborde; Martin B. Leon

Background—The design of a percutaneous implantable prosthetic heart valve has become an important area for investigation. A percutaneously implanted heart valve (PHV) composed of 3 bovine pericardial leaflets mounted within a balloon-expandable stent was developed. After ex vivo testing and animal implantation studies, the first human implantation was performed in a 57-year-old man with calcific aortic stenosis, cardiogenic shock, subacute leg ischemia, and other associated noncardiac diseases. Valve replacement had been declined for this patient, and balloon valvuloplasty had been performed with nonsustained results. Methods and Results—With the use of an antegrade transseptal approach, the PHV was successfully implanted within the diseased native aortic valve, with accurate and stable PHV positioning, no impairment of the coronary artery blood flow or of the mitral valve function, and a mild paravalvular aortic regurgitation. Immediately and at 48 hours after implantation, valve function was excellent, resulting in marked hemodynamic improvement. Over a follow-up period of 4 months, the valvular function remained satisfactory as assessed by sequential transesophageal echocardiography, and there was no recurrence of heart failure. However, severe noncardiac complications occurred, including a progressive worsening of the leg ischemia, leading to leg amputation with lack of healing, infection, and death 17 weeks after PHV implantation. Conclusions—Nonsurgical implantation of a prosthetic heart valve can be successfully achieved with immediate and midterm hemodynamic and clinical improvement. After further device modifications, additional durability tests, and confirmatory clinical implantations, PHV might become an important therapeutic alternative for the treatment of selected patients with nonsurgical aortic stenosis.


Eurointervention | 2013

The 2011-12 pilot European Sentinel Registry of Transcatheter Aortic Valve Implantation: in-hospital results in 4,571 patients.

Carlo Di Mario; Hélène Eltchaninoff; Neil Moat; Javier Goicolea; Gian Paolo Ussia; Petr Kala; Peter Wenaweser; Marian Zembala; Georg Nickenig; Eduardo Alegria Barrero; Thomas Snow; Bernard Iung; Pepe Zamorano; Gerhard Schuler; Roberto Corti; Ottavio Alfieri; Bernard Prendergast; Peter Ludman; Stephan Windecker; Manel Sabaté; Martine Gilard; Adam Witowski; Haim D. Danenberg; Erwin Schroeder; Francesco Romeo; Carlos Macaya; Geneviève Derumeaux; Aldo P. Maggioni; Luigi Tavazzi

AIMS The aim of this prospective multinational registry is to assess and identify predictors of in-hospital outcome and complications of contemporary TAVI practice. METHODS AND RESULTS The Transcatheter Valve Treatment Sentinel Pilot Registry is a prospective independent consecutive collection of individual patient data entered into a web-based case record form (CRF) or transferred from compatible national registries. A total of 4,571 patients underwent TAVI between January 2011 and May 2012 in 137 centres of 10 European countries. Average age was 81.4±7.1 years with equal representation of the two sexes. Logistic EuroSCORE (20.2±13.3), access site (femoral approach: 74.2%), type of anaesthesia and duration of hospital stay (9.3±8.1 days) showed wide variations among the participating countries. In-hospital mortality (7.4%), stroke (1.8%), myocardial infarction (0.9%), major vascular complications (3.1%) were similar in the SAPIEN XT and CoreValve (p=0.15). Mortality was lower in transfemoral (5.9%) than in transapical (12.8%) and other access routes (9.7%; p<0.01). Advanced age, high logistic EuroSCORE, pre-procedural ≥grade 2 mitral regurgitation and deployment failure predicted higher mortality at multivariate analysis. CONCLUSIONS Increased operator experience and the refinement of valve types and delivery catheters may explain the lower rate of mortality, stroke and vascular complications than in historical studies and registries.


Journal of the American College of Cardiology | 1998

Balloon angioplasty for the treatment of coronary in-stent restenosis : Immediate results and 6-month angiographic recurrent restenosis rate

Hélène Eltchaninoff; René Koning; Christophe Tron; Vivek Gupta; Alain Cribier

OBJECTIVES The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.


Circulation | 2014

Postprocedural Aortic Regurgitation in Balloon-Expandable and Self-Expandable Transcatheter Aortic Valve Replacement Procedures Analysis of Predictors and Impact on Long-Term Mortality: Insights From the FRANCE2 Registry

Eric Van Belle; Francis Juthier; Sophie Susen; André Vincentelli; Bernard Iung; Jean Dallongeville; Hélène Eltchaninoff; Marc Laskar; Pascal Leprince; Michel Lievre; Carlo Banfi; Jean-Luc Auffray; Cedric Delhaye; Patrick Donzeau-Gouge; Karine Chevreul; Jean Fajadet; Alain Leguerrier; Alain Prat; Martine Gilard; Emmanuel Teiger

Background— Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results— TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P=0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery (P=0.04), larger aortic annulus (P=0.0004), and smaller prosthesis diameter (P=0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery(P=0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P=0.0001) and SE-TAVR (hazard ratio=2.11; P=0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions— Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2.Background— Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results— TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P =0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery ( P =0.04), larger aortic annulus ( P =0.0004), and smaller prosthesis diameter ( P =0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery( P =0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P =0.0001) and SE-TAVR (hazard ratio=2.11; P =0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions— Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2. # CLINICAL PERSPECTIVE {#article-title-26}

Collaboration


Dive into the Hélène Eltchaninoff's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Eric Durand

Paris Descartes University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Jean Fajadet

Charles University in Prague

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge