The New England Journal of Medicine | 1996

IMPROVED SURVIVAL WITH AN IMPLANTED DEFIBRILLATOR IN PATIENTS WITH CORONARY DISEASE AT HIGH RISK FOR VENTRICULAR ARRHYTHMIA

Arthur J. Moss; W. Jackson Hall; David S. Cannom; James P. Daubert; Steven L. Higgins; Helmut U. Klein; Joseph Levine; Sanjeev Saksena; Albert L. Waldo; David J. Wilber; Mary W. Brown; Moonseong Heo

BACKGROUND Unsustained ventricular tachycardia in patients with previous myocardial infarction and left ventricular dysfunction is associated with a two-year mortality rate of about 30 percent. We studied whether prophylactic therapy with an implanted cardioverter-defibrillator, as compared with conventional medical therapy, would improve survival in this high-risk group of patients. METHODS Over the course of five years, 196 patients in New York Heart Association functional class I, II, or III with prior myocardial infarction; a left ventricular ejection fraction < or = 0.35; a documented episode of asymptomatic unsustained ventricular tachycardia; and inducible, nonsuppressible ventricular tachyarrhythmia on electrophysiologic study were randomly assigned to receive an implanted defibrillator (n = 95) or conventional medical therapy (n=101). We used a two-sided sequential design with death from any cause as the end point. RESULTS The base-line characteristics of the two treatment groups were similar. During an average follow-up of 27 months, there were 15 deaths in the defibrillator group (11 from cardiac causes) and 39 deaths in the conventional-therapy group (27 from cardiac causes) (hazard ratio for overall mortality, 0.46; 95 percent confidence interval, 0.26 to 0.82; P=0.009). There was no evidence that amiodarone, beta-blockers, or any other antiarrhythmic therapy had a significant influence on the observed hazard ratio. CONCLUSIONS In patients with a prior myocardial infarction who are at high risk for ventricular tachyarrhythmia, prophylactic therapy with an implanted defibrillator leads to improved survival as compared with conventional medical therapy.


The New England Journal of Medicine | 2009

Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events

Arthur J. Moss; Warren T. Jackson; David S. Cannom; Helmut U. Klein; Mary W. Brown; James P. Daubert; Elyse Foster; Henry Greenberg; Steven L. Higgins; Marc A. Pfeffer; Scott D. Solomon; David J. Wilber; Wojciech Zareba

BACKGROUND This trial was designed to determine whether cardiac-resynchronization therapy (CRT) with biventricular pacing would reduce the risk of death or heart-failure events in patients with mild cardiac symptoms, a reduced ejection fraction, and a wide QRS complex. METHODS During a 4.5-year period, we enrolled and followed 1820 patients with ischemic or nonischemic cardiomyopathy, an ejection fraction of 30% or less, a QRS duration of 130 msec or more, and New York Heart Association class I or II symptoms. Patients were randomly assigned in a 3:2 ratio to receive CRT plus an implantable cardioverter-defibrillator (ICD) (1089 patients) or an ICD alone (731 patients). The primary end point was death from any cause or a nonfatal heart-failure event (whichever came first). Heart-failure events were diagnosed by physicians who were aware of the treatment assignments, but they were adjudicated by a committee that was unaware of assignments. RESULTS During an average follow-up of 2.4 years, the primary end point occurred in 187 of 1089 patients in the CRT-ICD group (17.2%) and 185 of 731 patients in the ICD-only group (25.3%) (hazard ratio in the CRT-ICD group, 0.66; 95% confidence interval [CI], 0.52 to 0.84; P=0.001). The benefit did not differ significantly between patients with ischemic cardiomyopathy and those with nonischemic cardiomyopathy. The superiority of CRT was driven by a 41% reduction in the risk of heart-failure events, a finding that was evident primarily in a prespecified subgroup of patients with a QRS duration of 150 msec or more. CRT was associated with a significant reduction in left ventricular volumes and improvement in the ejection fraction. There was no significant difference between the two groups in the overall risk of death, with a 3% annual mortality rate in each treatment group. Serious adverse events were infrequent in the two groups. CONCLUSIONS CRT combined with ICD decreased the risk of heart-failure events in relatively asymptomatic patients with a low ejection fraction and wide QRS complex. (ClinicalTrials.gov number, NCT00180271.)


Circulation | 1999

Effect of Pacing Chamber and Atrioventricular Delay on Acute Systolic Function of Paced Patients With Congestive Heart Failure

Angelo Auricchio; Christoph Stellbrink; Michael Block; Stefan Sack; Jürgen Vogt; Patricia F.A. Bakker; Helmut U. Klein; Andrew P. Kramer; Jiang Ding; Rodney W. Salo; Bruce Tockman; Thierry Pochet; Julio C. Spinelli

BACKGROUND Previous studies of pacing therapy for dilated congestive heart failure (CHF) have not established the relative importance of pacing site, AV delay, and patient heterogeneity on outcome. These variables were compared by a novel technique that evaluated immediate changes in hemodynamic function during brief periods of atrial-synchronous ventricular pacing. METHODS AND RESULTS Twenty-seven CHF patients with severe left ventricular (LV) systolic dysfunction and LV conduction disorder were implanted with endocardial pacing leads in the right atrium and right ventricle (RV) and an epicardial lead on the LV and instrumented with micromanometer catheters in the LV, aorta, and RV. Patients in normal sinus rhythm were stimulated in the RV, LV, or both ventricles simultaneously (BV) at preselected AV delays in a repeating 5-paced/15-nonpaced beat sequence. Maximum LV pressure derivative (LV+dP/dt) and aortic pulse pressure (PP) changed immediately at pacing onset, increasing at a patient-specific optimal AV delay in 20 patients with wide surface QRS (180+/-22 ms) and decreasing at short AV delays in 5 patients with narrower QRS (128+/-12 ms) (P<0.0001). Overall, BV and LV pacing increased LV+dP/dt and PP more than RV pacing (P<0.01), whereas LV pacing increased LV+dP/dt more than BV pacing (P<0.01). CONCLUSIONS In this population, CHF patients with sufficiently wide surface QRS benefit from atrial-synchronous ventricular pacing, LV stimulation is required for maximum acute benefit, and the maximum benefit at any site occurs with a patient-specific AV delay.


American Journal of Cardiology | 2002

Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy

Frank Grothues; Gillian C. Smith; James C Moon; Nicholas G. Bellenger; Peter Collins; Helmut U. Klein; Dudley J. Pennell

Fast breath-hold cardiovascular magnetic resonance (CMR) shows excellent results for interstudy reproducibility of left ventricular (LV) volumes, ejection fraction, and mass, which are thought to be superior to results of 2-dimensional echocardiography. However, there is no direct comparison of the interstudy reproducibility of both methods in the same subjects. A total of 60 subjects (normal volunteers [n = 20], or patients with heart failure [n = 20] or LV hypertrophy [n = 20]) underwent 2 CMRs and 2 echocardiographic studies for assessment of LV volumes, function, and mass. The interstudy reproducibility coefficient of variability was superior for CMR in all groups for all parameters. Statistical significance was reached for end-systolic volume (4.4% to 9.2% vs 13.7% to 20.3%, p <0.001), ejection fraction (2.4% to 7.3% vs 8.6% to 19.4%, p <0.001), and mass (2.8% to 4.8% vs 11.6% to 15.7% p <0.001), with a trend for end-diastolic volume (2.9% to 4.9% vs 5.5% to 10.5%, p = 0.17). The superior interstudy reproducibility resulted in considerably lower calculated sample sizes (reductions of 55% to 93%) required by CMR compared with echocardiography to show clinically relevant changes in LV dimensions and function. Thus, CMR has excellent interstudy reproducibility in normal, dilated, and hypertrophic hearts, and is superior to 2-dimensional echocardiography.


The New England Journal of Medicine | 2012

Reduction in Inappropriate Therapy and Mortality through ICD Programming

Arthur J. Moss; Claudio Schuger; Christopher A. Beck; Mary W. Brown; David S. Cannom; James P. Daubert; Henry Greenberg; Warren T. Jackson; David T. Huang; Josef Kautzner; Helmut U. Klein; Scott McNitt; Brian Olshansky; Morio Shoda; David J. Wilber; Wojciech Zareba

BACKGROUND The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects. METHODS We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.5-second delay before the initiation of therapy at a heart rate of ≥200 beats per minute) or delayed therapy (with a 60-second delay at 170 to 199 beats per minute, a 12-second delay at 200 to 249 beats per minute, and a 2.5-second delay at ≥250 beats per minute) was associated with a decrease in the number of patients with a first occurrence of inappropriate antitachycardia pacing or shocks, as compared with conventional programming (with a 2.5-second delay at 170 to 199 beats per minute and a 1.0-second delay at ≥200 beats per minute). RESULTS During an average follow-up of 1.4 years, high-rate therapy and delayed ICD therapy, as compared with conventional device programming, were associated with reductions in a first occurrence of inappropriate therapy (hazard ratio with high-rate therapy vs. conventional therapy, 0.21; 95% confidence interval [CI], 0.13 to 0.34; P<0.001; hazard ratio with delayed therapy vs. conventional therapy, 0.24; 95% CI, 0.15 to 0.40; P<0.001) and reductions in all-cause mortality (hazard ratio with high-rate therapy vs. conventional therapy, 0.45; 95% CI, 0.24 to 0.85; P=0.01; hazard ratio with delayed therapy vs. conventional therapy, 0.56; 95% CI, 0.30 to 1.02; P=0.06). There were no significant differences in procedure-related adverse events among the three treatment groups. CONCLUSIONS Programming of ICD therapies for tachyarrhythmias of 200 beats per minute or higher or with a prolonged delay in therapy at 170 beats per minute or higher, as compared with conventional programming, was associated with reductions in inappropriate therapy and all-cause mortality during long-term follow-up. (Funded by Boston Scientific; MADIT-RIT ClinicalTrials.gov number, NCT00947310.).


Journal of the American College of Cardiology | 2008

Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II : Frequency, Mechanisms, Predictors, and Survival Impact

James P. Daubert; Wojciech Zareba; David S. Cannom; Scott McNitt; Spencer Rosero; Paul J. Wang; Claudio Schuger; Jonathan S. Steinberg; Steven L. Higgins; David J. Wilber; Helmut U. Klein; Mark L. Andrews; W. Jackson Hall; Arthur J. Moss

OBJECTIVES This study sought to identify the incidence and outcome related to inappropriate implantable cardioverter-defibrillator (ICD) shocks, that is, those for nonventricular arrhythmias. BACKGROUND The MADIT (Multicenter Automatic Defibrillator Implantation Trial) II showed that prophylactic ICD implantation improves survival in post-myocardial infarction patients with reduced ejection fraction. Inappropriate ICD shocks are common adverse consequences that may impair quality of life. METHODS Stored ICD electrograms from all shock episodes were adjudicated centrally. An inappropriate shock episode was defined as an episode during which 1 or more inappropriate shocks occurred; another inappropriate ICD episode occurring within 5 min was not counted. Programmed parameters for patients with and without inappropriate shocks were compared. RESULTS One or more inappropriate shocks occurred in 83 (11.5%) of the 719 MADIT II ICD patients. Inappropriate shock episodes constituted 184 of the 590 total shock episodes (31.2%). Smoking, prior atrial fibrillation, diastolic hypertension, and antecedent appropriate shock predicted inappropriate shock occurrence. Atrial fibrillation was the most common trigger for inappropriate shock (44%), followed by supraventricular tachycardia (36%), and then abnormal sensing (20%). The stability detection algorithm was programmed less frequently in patients receiving inappropriate shocks (17% vs. 36%, p = 0.030), whereas other programming parameters did not differ significantly from those without inappropriate shocks. Importantly, patients with inappropriate shocks had a greater likelihood of all-cause mortality in follow-up (hazard ratio 2.29, p = 0.025). CONCLUSIONS Inappropriate ICD shocks occurred commonly in the MADIT II study, and were associated with increased risk of all-cause mortality.


Circulation | 2011

Effectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT)

Wojciech Zareba; Helmut U. Klein; Iwona Cygankiewicz; W. Jackson Hall; Scott McNitt; Mary Beth Brown; David S. Cannom; James P. Daubert; Michael Eldar; Michael R. Gold; Jeffrey J. Goldberger; Ilan Goldenberg; Edgar Lichstein; Pitschner Hf; Mayer Rashtian; Scott D. Solomon; Sami Viskin; Paul J. Wang; Arthur J. Moss

Background— This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) trial. Methods and Results— Baseline 12-lead ECGs were evaluated with regard to QRS morphology. Heart failure event or death was the primary end point of the trial. Death, heart failure event, ventricular tachycardia, and ventricular fibrillation were secondary end points. Among 1817 patients with available sinus rhythm ECGs at baseline, there were 1281 (70%) with left bundle-branch block (LBBB), 228 (13%) with right bundle-branch block, and 308 (17%) with nonspecific intraventricular conduction disturbances. The latter 2 groups were defined as non-LBBB groups. Hazard ratios for the primary end point for comparisons of CRT-D patients versus patients who only received an implantable cardioverter defibrillator (ICD) were significantly (P<0.001) lower in LBBB patients (0.47; P<0.001) than in non-LBBB patients (1.24; P=0.257). The risk of ventricular tachycardia, ventricular fibrillation, or death was decreased significantly in CRT-D patients with LBBB but not in non-LBBB patients. Echocardiographic parameters showed significantly (P<0.001) greater reduction in left ventricular volumes and increase in ejection fraction with CRT-D in LBBB than in non-LBBB patients. Conclusions— Heart failure patients with New York Heart Association class I or II and ejection fraction ⩽30% and LBBB derive substantial clinical benefit from CRT-D: a reduction in heart failure progression and a reduction in the risk of ventricular tachyarrhythmias. No clinical benefit was observed in patients with a non-LBBB QRS pattern (right bundle-branch block or intraventricular conduction disturbances). Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT00180271.


Journal of the American College of Cardiology | 2000

Increased expression of extracellular signal-regulated kinase and angiotensin-converting enzyme in human atria during Atrial fibrillation

Andreas Goette; Thorsten Staack; Christoph Röcken; Marco Arndt; J. Christoph Geller; Christof Huth; Siegfried Ansorge; Helmut U. Klein; Uwe Lendeckel

OBJECTIVES The purpose of this study was to determine whether atrial expression of the extracellular signal-regulated kinases Erk1/Erk2 and of the angiotensin-converting enzyme (ACE) is altered in patients with atrial fibrillation (AF). BACKGROUND Recent studies have demonstrated that atrial fibrosis can provide a pathophysiologic substrate for AF. However, the molecular mechanisms responsible for the development of atrial fibrosis are unclear. METHODS Atrial tissue samples of 43 patients undergoing open heart surgery were examined. Seventeen patients had chronic persistent AF (> or =6 months; CAF), 8 patients had paroxysmal AF (PAF) and 18 patients had no history of AF. Erk expression was analyzed at the mRNA (quantitative reverse transcription polymerase chain reaction), the protein (immunoblot techniques) and atrial tissue (immunohistochemistry) levels. Erk-activating kinases (MEK1/2) and ACE were analyzed by immunoblot techniques. RESULTS Increased amounts of Erk2-mRNA were found in patients with CAF (75 +/- 20 U vs. sinus rhythm: 31 +/- 25 U; p < 0.05). Activated Erk1/Erk2 and MEK1/2 were increased to more than 150% in patients with AF compared to patients with sinus rhythm. No differences between CAF and PAF were found. The expression of ACE was three-fold increased during CAF. Amounts of activated Erk1/Erk2 were reduced in patients treated with ACE inhibitors. Patients with AF showed an increased expression of Erk1/Erk2 in interstitial cells and marked atrial fibrosis. CONCLUSIONS An ACE-dependent increase in the amounts of activated Erk1/Erk2 in atrial interstitial cells may contribute as a molecular mechanism for the development of atrial fibrosis in patients with AF. These findings may have important impact on the treatment of AF.


Circulation | 2004

Characterization of Left Ventricular Activation in Patients With Heart Failure and Left Bundle-Branch Block

Angelo Auricchio; Cecilia Fantoni; François Regoli; Corrado Carbucicchio; Andreas Goette; Christoph Geller; Michael Kloss; Helmut U. Klein

Background—Conventional activation mapping in the dilated human left ventricle (LV) with left bundle-branch block (LBBB) morphology is incomplete given the limited number of recording sites that may be collected in a reasonable time and given the lack of precision in marking specific anatomic locations. Methods and Results—We studied LV activation sequences in 24 patients with heart failure and LBBB QRS morphology with simultaneous application of 3D contact and noncontact mapping during intrinsic rhythm and asynchronous pacing. Approximately one third of the patients with typical LBBB QRS morphology had normal transseptal activation time and a slightly prolonged or near-normal LV endocardial activation time. A “U-shaped” activation wave front was present in 23 patients because of a line of block that was located anteriorly (n=12), laterally (n=8), and inferiorly (n=3). Patients with a lateral line of block had significantly shorter QRS (P <0.003) and transseptal durations (P <0.001) and a longer distance from the LV breakthrough site to line of block (P <0.03). Functional behavior of the line of block was demonstrated by a change in its location during asynchronous ventricular pacing at different sites and cycle lengths. Conclusions—A U-shaped conduction pattern is imposed on the LV activation sequence by a transmural functional line of block located between the LV septum and the lateral wall with a prolonged activation time. Assessment of functional block is facilitated by noncontact mapping, which may be useful for identifying and targeting specific locations that are optimal for successful cardiac resynchronization therapy.


Circulation | 2011

Left Ventricular Lead Position and Clinical Outcome in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) Trial

Jagmeet P. Singh; Helmut U. Klein; David T. Huang; Sven Reek; Malte Kuniss; Aurelio Quesada; Alon Barsheshet; David S. Cannom; Ilan Goldenberg; Scott McNitt; James P. Daubert; Wojciech Zareba; Arthur J. Moss

Background— An important determinant of successful cardiac resynchronization therapy for heart failure is the position of the left ventricular (LV) pacing lead. The aim of this study was to analyze the impact of the LV lead position on outcome in patients randomized to cardiac resynchronization-defibrillation in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) study. Methods and Results— The location of the LV lead was assessed by means of coronary venograms and chest x-rays recorded at the time of device implantation. The LV lead location was classified along the short axis into an anterior, lateral, or posterior position and along the long axis into a basal, midventricular, or apical region. The primary end point of MADIT-CRT was heart failure (HF) hospitalization or death, whichever came first. The LV lead position was assessed in 799 patients, (55% patients ≥65 years of age, 26% female, 10% LV ejection fraction ⩽25%, 55% ischemic cardiomyopathy, and 71% left bundle-branch block) with a follow-up of 29±11 months. The extent of cardiac resynchronization therapy benefit was similar for leads in the anterior, lateral, or posterior position (P=0.652). The apical lead location compared with leads located in the nonapical position (basal or midventricular region) was associated with a significantly increased risk for heart failure/death (hazard ratio=1.72; 95% confidence interval, 1.09 to 2.71; P=0.019) after adjustment for the clinical covariates. The apical lead position was also associated with an increased risk for death (hazard ratio=2.91; 95% confidence interval, 1.42 to 5.97; P=0.004). Conclusion— LV leads positioned in the apical region were associated with an unfavorable outcome, suggesting that this lead location should be avoided in cardiac resynchronization therapy. Clinical Trial Registration— URL: http://clinicaltrials.gov. Unique identifier: NCT00180271.

Collaboration


Dive into the Helmut U. Klein's collaboration.

Top Co-Authors

Avatar

Arthur J. Moss

University of Rochester Medical Center

View shared research outputs
Top Co-Authors

Avatar

Wojciech Zareba

University of Rochester Medical Center

View shared research outputs
Top Co-Authors

Avatar

Scott McNitt

University of Rochester Medical Center

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Valentina Kutyifa

University of Rochester Medical Center

View shared research outputs
Top Co-Authors

Avatar

Andreas Goette

Otto-von-Guericke University Magdeburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Sven Reek

University of Alabama at Birmingham

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge