Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hidenobu Suzuki is active.

Publication


Featured researches published by Hidenobu Suzuki.


Proceedings of SPIE | 2013

Blood vessel-based liver segmentation through the portal phase of a CT dataset

Ahmed S. Maklad; Mikio Matsuhiro; Hidenobu Suzuki; Yoshiki Kawata; Noboru Niki; Noriyuki Moriyama; Tohru Utsunomiya; Mitsuo Shimada

Blood vessels are dispersed throughout the human body organs and carry unique information for each person. This information can be used to delineate organ boundaries. The proposed method relies on abdominal blood vessels (ABV) to segment the liver considering the potential presence of tumors through the portal phase of a CT dataset. ABV are extracted and classified into hepatic (HBV) and nonhepatic (non-HBV) with a small number of interactions. HBV and non-HBV are used to guide an automatic segmentation of the liver. HBV are used to individually segment the core region of the liver. This region and non-HBV are used to construct a boundary surface between the liver and other organs to separate them. The core region is classified based on extracted posterior distributions of its histogram into low intensity tumor (LIT) and non-LIT core regions. Non-LIT case includes normal part of liver, HBV, and high intensity tumors if exist. Each core region is extended based on its corresponding posterior distribution. Extension is completed when it reaches either a variation in intensity or the constructed boundary surface. The method was applied to 80 datasets (30 Medical Image Computing and Computer Assisted Intervention (MICCAI) and 50 non-MICCAI data) including 60 datasets with tumors. Our results for the MICCAI-test data were evaluated by sliver07 [1] with an overall score of 79.7, which ranks seventh best on the site (December 2013). This approach seems a promising method for extraction of liver volumetry of various shapes and sizes and low intensity hepatic tumors.


Medical Physics | 2013

Blood vessel‐based liver segmentation using the portal phase of an abdominal CT dataset

Ahmed S. Maklad; Mikio Matsuhiro; Hidenobu Suzuki; Yoshiki Kawata; Noboru Niki; Mitsuo Satake; Noriyuki Moriyama; Toru Utsunomiya; Mitsuo Shimada

PURPOSE Blood vessel (BV) information can be used to guide body organ segmentation on computed tomography (CT) imaging. The proposed method uses abdominal BVs (ABVs) to segment the liver through the portal phase of an abdominal CT dataset. This method aims to address the wide variability in liver shape and size, separate liver from other organs of similar intensity, and segment hepatic low-intensity tumors (LITs). METHODS Thin ABVs are enhanced using three-dimensional (3D) opening. ABVs are extracted and classified into hepatic BVs (HBVs) and nonhepatic BVs (non-HBVs) with a small number of interactions, and HBVs and non-HBVs are used for constraining automatic liver segmentation. HBVs are used to individually segment the core region of the liver. To separate the liver from other organs, this core region and non-HBVs are used to construct an initial 3D boundary surface. To segment LITs, the core region is classified into non-LIT- and LIT-parts by fitting the histogram of the core region using a variational Bayesian Gaussian mixture model. Each part of the core region is extended based on its corresponding component of the mixture, and extension is completed when it reaches a variation in intensity or the constructed boundary surface, which is reconfirmed to fit robustly between the liver and neighboring organs of similar intensity. A solid-angle technique is used to refine main BVs at the entrances to the inferior vena cava and the portal vein. RESULTS The proposed method was applied to 80 datasets: 30 Medical Image Computing and Computer Assisted Intervention (MICCAI) and 50 non-MICCAI; 30 datasets of non-MICCAI data include tumors. Our results for MICCAI-test data were evaluated by sliver07 (http://www.sliver07.org/) organizers with an overall score of 85.7, which ranks best on the site as of July 2013. These results (average ± standard deviation) include the five error measures of the 2007 MICCAI workshop for liver segmentation as follows. Results for volume overlap error, relative volume difference, average symmetric surface distance, root mean square symmetric surface distance, and maximum symmetric surface distance were 4.33 ± 0.73, 0.28 ± 0.87, 0.63 ± 0.16, 1.19 ± 0.28, and 14.01 ± 2.88, respectively; and when applying our method to non-MICCAI data, results were 3.21 ± 0.75, 0.06 ± 1.29, 0.45 ± 0.17, 0.98 ± 0.26, and 12.69 ± 3.89, respectively. These results demonstrate high performance of the method when applied to different CT datasets. CONCLUSIONS BVs can be used to address the wide variability in liver shape and size, as BVs provide unique details for the structure of each studied liver. Constructing a boundary surface using HBVs and non-HBVs can separate liver from its neighboring organs of similar intensity. By fitting the histogram of the core region using a variational Bayesian Gaussian mixture model, LITs are segmented and measuring the volumetry of non-LIT- and LIT-parts becomes possible. Further examination of the proposed method on a large number of datasets is required for clinical applications, and development of the method for full automation may be possible and useful in the clinic.


Proceedings of SPIE | 2013

Extraction method of interlobar fissure based on multi-slice CT images

Mikio Matsuhiro; Hidenobu Suzuki; Yoshiki Kawata; Noboru Niki; Junji Ueno; Yasutaka Nakano; Emiko Ogawa; Shigeo Muro; Michiaki Mishima; Hironobu Ohmatsu; Noriyuki Moriyama

Extraction of inter lobar fissure is an active study for diagnosis and treatment. However, lung diseased cases have problems. The proposed method covers diseased cases, and contains three phases of coarse extract, fine extract and correction, using behavior of membrane. We applied this method to normal and lung diseased cases. Rate (average±standard eviation) of gold standard within 2 mm of extraction result were 91.2±3.6% for normal, and 89.7±4.9% for lung diseased cases. Rate of extraction result within 2 mm of gold standard for normal cases were 95.5±3.7%, and 93.6±4.8% for lung diseased.


Medical Imaging 2007: PACS and Imaging Informatics | 2007

Anonymization server system for DICOM images

Hidenobu Suzuki; Masafumi Amano; Mitsuru Kubo; Yoshiki Kawata; Noboru Niki; Hiromu Nishitani

We have developed an anonymization system for DICOM images. It requires consent from the patient to use the DICOM images for research or education. However, providing the DICOM image to the other facilities is not safe because it contains a lot of personal data. Our system is a server that provides anonymization service of DICOM images for users in the facility. The distinctive features of the system are, input interface, flexible anonymization policy, and automatic body part identification. In the first feature, we can use the anonymization service on the existing DICOM workstations. In the second feature, we can select a best policy fitting for the Protection of personal data that is ruled by each medical facility. In the third feature, we can identify the body parts that are included in the input image set, even if the set lacks the body part tag in DICOM header. We installed the system for the first time to a hospital in December 2005. Currently, the system is working in other four facilities. In this paper we describe the system and how it works.


Proceedings of SPIE | 2012

Extraction of liver volumetry based on blood vessel from the portal phase CT dataset

Ahmed S. Maklad; Mikio Matsuhiro; Hidenobu Suzuki; Yoshiki Kawata; Noboru Niki; Tohru Utsunomiya; Mitsuo Shimada

At liver surgery planning stage, the liver volumetry would be essential for surgeons. Main problem at liver extraction is the wide variability of livers in shapes and sizes. Since, hepatic blood vessels structure varies from a person to another and covers liver region, the present method uses that information for extraction of liver in two stages. The first stage is to extract abdominal blood vessels in the form of hepatic and nonhepatic blood vessels. At the second stage, extracted vessels are used to control extraction of liver region automatically. Contrast enhanced CT datasets at only the portal phase of 50 cases is used. Those data include 30 abnormal livers. A reference for all cases is done through a comparison of two experts labeling results and correction of their inter-reader variability. Results of the proposed method agree with the reference at an average rate of 97.8%. Through application of different metrics mentioned at MICCAI workshop for liver segmentation, it is found that: volume overlap error is 4.4%, volume difference is 0.3%, average symmetric distance is 0.7 mm, Root mean square symmetric distance is 0.8 mm, and maximum distance is 15.8 mm. These results represent the average of overall data and show an improved accuracy compared to current liver segmentation methods. It seems to be a promising method for extraction of liver volumetry of various shapes and sizes.


Proceedings of SPIE | 2009

An automated distinction of DICOM images for lung cancer CAD system

Hidenobu Suzuki; Shinsuke Saita; Mitsuru Kubo; Yoshiki Kawata; Noboru Niki; Hiromu Nishitani; Hironobu Ohmatsu; Kenji Eguchi; Masahiro Kaneko; Noriyuki Moriyama

Automated distinction of medical images is an important preprocessing in Computer-Aided Diagnosis (CAD) systems. The CAD systems have been developed using medical image sets with specific scan conditions and body parts. However, varied examinations are performed in medical sites. The specification of the examination is contained into DICOM textual meta information. Most DICOM textual meta information can be considered reliable, however the body part information cannot always be considered reliable. In this paper, we describe an automated distinction of DICOM images as a preprocessing for lung cancer CAD system. Our approach uses DICOM textual meta information and low cost image processing. Firstly, the textual meta information such as scan conditions of DICOM image is distinguished. Secondly, the DICOM image is set to distinguish the body parts which are identified by image processing. The identification of body parts is based on anatomical structure which is represented by features of three regions, body tissue, bone, and air. The method is effective to the practical use of lung cancer CAD system in medical sites.


International Journal of Chronic Obstructive Pulmonary Disease | 2018

Relationship of annual change in bone mineral density with extent of emphysematous lesions and pulmonary function in patients with COPD

Kenichi Goto; Emiko Ogawa; Kaoruko Shimizu; Hironi Makita; Hidenobu Suzuki; Yoshiki Kawata; Noboru Niki; Masaharu Nishimura; Yasutaka Nakano

Background Osteoporosis is a well-known comorbidity in COPD. It is associated with poor health status and prognosis. Although the exact pathomechanisms are unclear, osteoporosis is suggested to be either a comorbidity due to shared risk factors with COPD or a systematic effect of COPD with a cause–effect relationship. This study aimed to evaluate whether progression of osteoporosis is synchronized with that of COPD. Materials and methods Data from 103 patients with COPD included in the Hokkaido COPD cohort study were analyzed. Computed tomography (CT) attenuation values of thoracic vertebrae 4, 7, and 10 were measured using custom software, and the average value (average bone density; ABD4,7,10) was calculated. The percentage of low attenuation volume (LAV%) for each patient was also calculated for evaluation of emphysematous lesions. Annual change in thoracic vertebral CT attenuation, which is strongly correlated with dual-energy X-ray absorptiometry-measured bone mineral density, was compared with that in FEV1.0 or emphysematous lesions. Results In the first CT data set, ABD4,7,10 was significantly correlated with age (ρ=−0.331; p=0.0006), body mass index (BMI; ρ=0.246; p=0.0136), St George’s Respiratory Questionnaire (SGRQ) activity score (ρ=−0.248; p=0.0115), eosinophil count (ρ=0.229; p=0.0198), and LAV% (ρ=−0.372; p=0.0001). However, ABD4,7,10 was not associated with FEV1.0. After adjustment for age, BMI, SGRQ activity score, and eosinophil count, no significant relationship was found between ABD4,7,10 and LAV%. Annual change in ABD4,7,10 was not associated with annual change in LAV% or FEV1.0. Conclusion Progression of osteoporosis and that of COPD are not directly related or synchronized with each other.


Medical Imaging 2018: Computer-Aided Diagnosis | 2018

Computer aided detection system for Osteoporosis using low dose thoracic 3D CT images

Daisuke Tsuji; Mikio Matsuhiro; Hidenobu Suzuki; Yoshiki Kawata; Noboru Niki; Yasutaka Nakano; Masafumi Harada; Masahiko Kusumoto; Takaaki Tsuchida; Kenji Eguchi; Masahiro Kaneko

The patient of osteoporosis is about 13 million people in Japan and it is one of healthy life problems in the aging society. It is necessary to do early stage detection and treatment in order to prevent the osteoporosis. Multi-slice CT technology has been improving the three dimensional (3D) image analysis with higher resolution and shorter scan time. The 3D image analysis of thoracic vertebra can be used for supporting to diagnosis of osteoporosis. This analysis can be used for lung cancer detection at the same time. We develop method of shape analysis and CT values of spongy bone for the detection osteoporosis. Osteoporosis and lung cancer screening show high extraction rate by the thoracic vertebral evaluation CT images. In addition, we created standard pattern of CT value per thoracic vertebra for male age group using 298 low dose data.


Medical Imaging 2018: Computer-Aided Diagnosis | 2018

Quantitative assessment for pneumoconiosis severity diagnosis using 3D CT images.

Koki Hino; Hidenobu Suzuki; Mikio Matsuhiro; Yoshiki Kawata; Noboru Niki; Katsuya Kato; Takumi Kishimoto; Kazuto Ashizawa

Pneumoconiosis is an occupational respiratory illness that occur by inhaling dust to the lungs. 240,000 participants are screened for diagnosis of pneumoconiosis every year in Japan. Radiograph is used for staging of severity rate in pneumoconiosis worldwide. CT imaging is useful for the differentiation of requirements for industrial accident approval because it can detect small lesions in comparison with radiograph. In this paper, we extracted lung nodules from 3D pneumoconiosis CT images by two manual processes and automatic process, and created a database of pneumoconiosis CT images. We used the database to analyze, compare, and evaluate visual diagnostic results of radiographs and quantitative assessment (number, size and volume) of lung nodules. This method was applied to twenty pneumoconiosis patients. Initial results showed that the proposed method can assess severity rate in pneumoconiosis quantitatively. This study demonstrates effectiveness on diagnosis and prognosis of pneumoconiosis in CT screening.


Medical Imaging 2018: Computer-Aided Diagnosis | 2018

Automatic blood vessel based- liver segmentation using the portal phase abdominal CT.

Ahmed S. Maklad; Mikio Matsuhiro; Hidenobu Suzuki; Yoshiki Kawata; Noboru Niki; Mitsuo Shimada; Gen Iinuma

Liver segmentation is the basis for computer-based planning of hepatic surgical interventions. In diagnosis and analysis of hepatic diseases and surgery planning, automatic segmentation of liver has high importance. Blood vessel (BV) has showed high performance at liver segmentation. In our previous work, we developed a semi-automatic method that segments the liver through the portal phase abdominal CT images in two stages. First stage was interactive segmentation of abdominal blood vessels (ABVs) and subsequent classification into hepatic (HBVs) and non-hepatic (non-HBVs). This stage had 5 interactions that include selective threshold for bone segmentation, selecting two seed points for kidneys segmentation, selection of inferior vena cava (IVC) entrance for starting ABVs segmentation, identification of the portal vein (PV) entrance to the liver and the IVC-exit for classifying HBVs from other ABVs (non-HBVs). Second stage is automatic segmentation of the liver based on segmented ABVs as described in [4]. For full automation of our method we developed a method [5] that segments ABVs automatically tackling the first three interactions. In this paper, we propose full automation of classifying ABVs into HBVs and non- HBVs and consequently full automation of liver segmentation that we proposed in [4]. Results illustrate that the method is effective at segmentation of the liver through the portal abdominal CT images.

Collaboration


Dive into the Hidenobu Suzuki's collaboration.

Top Co-Authors

Avatar

Noboru Niki

University of Tokushima

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Yasutaka Nakano

Shiga University of Medical Science

View shared research outputs
Top Co-Authors

Avatar

Kenji Eguchi

University of Tokushima

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge