Artificial Organs | 2018

Accurate Method of Quantification of Aortic Insufficiency During Left Ventricular Assist Device Support by Thermodilution Analysis: Proof of Concept and Validation by a Mock Circulatory System: QUANTIFICATION OF AORTIC INSUFFICIENCY BY THERMODILUTION

Daichi Akiyama; Takashi Nishimura; Hirohito Sumikura; Kei Iizuka; Toshihide Mizuno; Tomonori Tsukiya; Yoshiaki Takewa; Minoru Ono; Eisuke Tatsumi

Aortic insufficiency (AI) is an intractable complication during long term left ventricular assist device (LVAD) support. Conventional evaluation of AI depends on ultrasound evaluation, which is mainly a qualitative, not a quantitative method. The pathophysiology of AI during LVAD is shunt formation. Conversely, the methods to quantify the shunt of congenital heart disease are already established, and among these is the thermodilution technique. To develop an accurate quantification method for AI (namely, a shunt), we have adopted this conventional thermodilution technique. The purpose of this study was to determine whether this technique could calculate the shunt magnitude accurately in a simulated cardiac circuit. The magnitude of AI was represented by the recirculation rate (RR), defined by regurgitant flow (RF) divided by pump flow (PF). A mock circulatory system for an LVAD endurance test (Laboheart NCVC; Iwaki & Co., Ltd, Tokyo, Japan) was used. A centrifugal LVAD was equipped in the Laboheart in parallel from the left ventricle to the aorta. A parallel shunt circuit was created across the aortic valve to mimic AI. To control the magnitude of AI, the resistance of the AI circuit was changed. Heart failure was simulated by controlling the parameters of the Laboheart. The LVAD was driven in full bypass condition, confirming that the heart did not eject forward flow via the aortic valve. PF, RF, and the temperatures of two points of the outflow graft measured with two thermistors were monitored. Analyses were started after confirming that circuit water temperature was the same as room temperature. Hot water was injected from a port between the two thermistors of the outflow conduit. The time-temperature curves of both thermistors were recorded, and RR was calculated. Two values of RR calculated in two different ways (by analyzing thermistors and by calculating from flowmeter values) were compared. Multiple measurements were done by changing the magnitude of AI. The existence of AI could be easily confirmed by analyzing the temperature data. There was a good correlation between RR by thermistor and RR by flowmeter data (r = 0.984). Furthermore, the two RR values were almost the same. This novel technique could provide an accurate method for quantifying AI during LVAD support. This method can be clinically applied by left-sided cardiac catheterization if a dedicated catheter with two thermistors and an injection hole is developed.


Advances in Chemical Engineering and Science | 2013

Improved Hemolytic Performance of Blood Pump with Fluorine-Doped Hydrogenated Amorphous Carbon Coating

Yasuharu Ohgoe; Masanori Hiratsuka; Hirohito Sumikura; Kazuyoshi Fukunaga; Akihiko Homma; Kenji Hirakuri; Akio Funakubo; Yasuhiro Fukui


Archive | 2011

Heart-function simulator

Yoshiyuki Taenaka; 義之 妙中; Eisuke Tatsumi; 巽 英介; Akihiko Homma; 章彦 本間; Hirohito Sumikura; 博仁 住倉; Kentaro Ohnuma; 健太郎 大沼; Kazuo Katano; 一夫 片野; Hiroshi Mukaibayashi; 宏 向林


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2018

Development of a portable pneumatic driver for ventricular assist devices

Tomonori Tsukiya; Hirohito Sumikura; Akihiko Homma; Kentaro Ohnuma; Kouichi Kojima; Eisuke Tatsumi


The Proceedings of the JSME Conference on Frontiers in Bioengineering | 2017

Development of a portable pneumatic driver for an extracorporeal ventricular assist device

Tomonori Tsukiya; Hirohito Sumikura; Akihiko Homma; Kentaro Ohnuma; Eisuke Tatsumi


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2017

Evaluation of antithrombogenicity of the extracorporeal ventricular assist device

Tomonori Tsukiya; Hirohito Sumikura; Toshihide Mizuno; Yoshiaki Takewa; Eisuke Tatsumi; Yoshiyuki Taenaka


The Proceedings of Mechanical Engineering Congress, Japan | 2016

Preclinical Evaluations of an Extracorporeal Ventricular Assist Device

Tomonori Tsukiya; Hirohito Sumikura; Toshihide Sumikura; Yoshiaki Takewa; Eisuke Tatsumi


The Proceedings of Mechanical Engineering Congress, Japan | 2016

Autonomous Flow Rate Control for a Ventricular Assist Device on the Basis of Driving Current by Stochastic Method

Kentaro Ohnuma; Hirohito Sumikura; Akihiko Homma; Tomonori Tsukiya; Eisuke Tatsumi


The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME | 2015

1B21 Development of a Centrifugal Pump for Extracorporeal Left Heart Bypass

Tomonori Tsukiya; Hirohito Sumikura; Yutaka Fujii; Toshihide Mizuno; Yoshiaki Takewa; Eisuke Tatsumi


The Proceedings of Mechanical Engineering Congress, Japan | 2015

S0220102 Improvement and evaluation of a mechanical circulatory support device for assisting selective renal blood circulation

Hirohito Sumikura; Kentaro Ohnuma; Shigeru Hanada; Tomonori Tsukiya; Toshihide Mizuno; Akihiko Homma; Hiroshi Mukaibayashi; Koichi Kojima; Yoshiaki Takewa; Eisuke Tatsumi

Collaboration


Dive into the Hirohito Sumikura's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge