Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hirokazu Atsumori is active.

Publication


Featured researches published by Hirokazu Atsumori.


NeuroImage | 2013

A NIRS–fMRI investigation of prefrontal cortex activity during a working memory task

Hiroki Sato; Noriaki Yahata; Tsukasa Funane; Takusige Katura; Hirokazu Atsumori; Yukika Nishimura; Akihide Kinoshita; Masashi Kiguchi; Hideaki Koizumi; Masato Fukuda; Kiyoto Kasai

Near-infrared spectroscopy (NIRS) is commonly used for studying human brain function. However, several studies have shown that superficial hemodynamic changes such as skin blood flow can affect the prefrontal NIRS hemoglobin (Hb) signals. To examine the criterion-related validity of prefrontal NIRS-Hb signals, we focused on the functional signals during a working memory (WM) task and investigated their similarity with blood-oxygen-level-dependent (BOLD) signals simultaneously measured by functional magnetic resonance imaging (fMRI). We also measured the skin blood flow with a laser Doppler flowmeter (LDF) at the same time to examine the effect of superficial hemodynamic changes on the NIRS-Hb signals. Correlation analysis demonstrated that temporal changes in the prefrontal NIRS-Hb signals in the activation area were significantly correlated with the BOLD signals in the gray matter rather than those in the soft tissue or the LDF signals. While care must be taken when comparing the NIRS-Hb signal with the extracranial BOLD or LDF signals, these results suggest that the NIRS-Hb signal mainly reflects hemodynamic changes in the gray matter. Moreover, the amplitudes of the task-related responses of the NIRS-Hb signals were significantly correlated with the BOLD signals in the gray matter across participants, which means participants with a stronger NIRS-Hb response showed a stronger BOLD response. These results thus provide supportive evidence that NIRS can be used to measure hemodynamic signals originating from prefrontal cortex activation.


Review of Scientific Instruments | 2009

Development of wearable optical topography system for mapping the prefrontal cortex activation

Hirokazu Atsumori; Masashi Kiguchi; Akiko Obata; Hiroki Sato; Takusige Katura; Tsukasa Funane; Atsushi Maki

Optical topography (OT) based on near infrared spectroscopy is effective for measuring changes in the concentrations of oxygenated hemoglobin (oxy-Hb) and deoxygenated hemoglobin (deoxy-Hb) in the brain. It can be used to investigate brain functions of subjects of all ages because it is noninvasive and less constraining for subjects. Conventional OT systems use optical fibers to irradiate the scalp and detect light transmitted through the tissue in the human head, but optical fibers limit the subjects head position, so some small systems have been developed without using optical fibers. These systems, however, have a small number of measurement channels. We developed a prototype of a small, light, and wearable OT system that covers the entire forehead. We measured changes in the concentrations of oxy-Hb and deoxy-Hb in the prefrontal cortex while a subject performed a word fluency task. The results show typical changes in oxy-Hb and deoxy-Hb during the task and suggest that the prototype of our system can be used to investigate functions in the prefrontal cortex.


Journal of Biomedical Optics | 2010

Noninvasive imaging of prefrontal activation during attention-demanding tasks performed while walking using a wearable optical topography system

Hirokazu Atsumori; Masashi Kiguchi; Takusige Katura; Tsukasa Funane; Akiko Obata; Hiroki Sato; Takaaki Manaka; Mitsumasa Iwamoto; Atsushi Maki; Hideaki Koizumi; Kisou Kubota

Optical topography (OT) based on near-infrared spectroscopy is a noninvasive technique for mapping the relative concentration changes in oxygenated and deoxygenated hemoglobin (oxy- and deoxy-Hb, respectively) in the human cerebral cortex. In our previous study, we developed a small and light wearable optical topography (WOT) system that covers the entire forehead for monitoring prefrontal activation. In the present study, we examine whether the WOT system is applicable to OT measurement while walking, which has been difficult with conventional OT systems. We conduct OT measurements while subjects perform an attention-demanding (AD) task of balancing a ping-pong ball on a small card while walking. The measured time course and power spectra of the relative concentration changes in oxy- and deoxy-Hb show that the step-related changes in the oxy- and deoxy-Hb signals are negligible compared to the task-related changes. Statistical assessment of the task-related changes in the oxy-Hb signals show that the dorsolateral prefrontal cortex and rostral prefrontal area are significantly activated during the AD task. These results suggest that our functional imaging technique with the WOT system is applicable to OT measurement while walking, and will be a powerful tool for evaluating brain activation in a natural environment.


Journal of Biomedical Optics | 2008

Extracting task-related activation components from optical topography measurement using independent components analysis

Takusige Katura; Hiroki Sato; Yutaka Fuchino; Takamasa Yoshida; Hirokazu Atsumori; Masashi Kiguchi; Atsushi Maki; Masanori Abe; Naoki Tanaka

Optical topography (OT) signals measured during an experiment that used activation tasks for certain brain functions contain neuronal-activation induced blood oxygenation changes and also physiological changes. We used independent component analysis to separate the signals and extracted components related to brain activation without using any hemodynamic models. The analysis procedure had three stages: first, OT signals were separated into independent components (ICs) by using a time-delayed decorrelation algorithm; second, task-related ICs (TR-ICs) were selected from the separated ICs based on their mean intertrial cross-correlations; and third, the TR-ICs were categorized by k-means clustering into TR activation-related ICs (TR-AICs) and TR noise ICs (TR-NICs). We applied this analysis procedure to the OT signals obtained from experiments using one-handed finger-tapping tasks. In the averaged waveform of the TR-AICs, a small overshoot can be seen for a few seconds after the onset of each task and a few seconds after it ends, and the averaged waveforms of the TR-NICs have an N-shaped pattern.


Neurophotonics | 2016

Tutorial on platform for optical topography analysis tools

Stephanie Sutoko; Hiroki Sato; Atsushi Maki; Masashi Kiguchi; Yukiko Hirabayashi; Hirokazu Atsumori; Akiko Obata; Tsukasa Funane; Takusige Katura

Abstract. Optical topography/functional near-infrared spectroscopy (OT/fNIRS) is a functional imaging technique that noninvasively measures cerebral hemoglobin concentration changes caused by neural activities. The fNIRS method has been extensively implemented to understand the brain activity in many applications, such as neurodisorder diagnosis and treatment, cognitive psychology, and psychiatric status evaluation. To assist users in analyzing fNIRS data with various application purposes, we developed a software called platform for optical topography analysis tools (POTATo). We explain how to handle and analyze fNIRS data in the POTATo package and systematically describe domain preparation, temporal preprocessing, functional signal extraction, statistical analysis, and data/result visualization for a practical example of working memory tasks. This example is expected to give clear insight in analyzing data using POTATo. The results specifically show the activated dorsolateral prefrontal cortex is consistent with previous studies. This emphasizes analysis robustness, which is required for validating decent preprocessing and functional signal interpretation. POTATo also provides a self-developed plug-in feature allowing users to create their own functions and incorporate them with established POTATo functions. With this feature, we continuously encourage users to improve fNIRS analysis methods. We also address the complications and resolving opportunities in signal analysis.


Journal of Biomedical Optics | 2012

Dynamic phantom with two stage-driven absorbers for mimicking hemoglobin changes in superficial and deep tissues.

Tsukasa Funane; Hirokazu Atsumori; Masashi Kiguchi; Yukari Tanikawa; Eiji Okada

In near-infrared spectroscopy (NIRS) for monitoring brain activity and cerebral functional connectivity, the effect of superficial tissue on NIRS signals needs to be considered. Although some methods for determining the effect of scalp and brain have been proposed, direct validation of the methods has been difficult because the actual absorption changes cannot be known. In response to this problem, we developed a dynamic phantom that mimics hemoglobin changes in superficial and deep tissues, thus allowing us to experimentally validate the methods. Two absorber layers are independently driven with two one-axis automatic stages. We can use the phantom to design any type of waveform (e.g., brain activity or systemic fluctuation) of absorption change, which can then be reproducibly measured. To determine the effectiveness of the phantom, we used it for a multiple source-detector distance measurement. We also investigated the performance of a subtraction method with a short-distance regressor. The most accurate lower-layer change was obtained when a shortest-distance channel was used. Furthermore, when an independent component analysis was applied to the same data, the extracted components were in good agreement with the actual signals. These results demonstrate that the proposed phantom can be used for evaluating methods of discriminating the effects of superficial tissue.


IEICE Transactions on Communications | 2008

GO-STOP Control Using Optical Brain-Computer Interface during Calculation Task

Kei Utsugi; Akiko Obata; Hiroki Sato; Ryuta Aoki; Atsushi Maki; Hideaki Koizumi; Kazuhiko Sagara; Hiroaki Kawamichi; Hirokazu Atsumori; Takusige Katura

We have developed a prototype optical brain-computer interface (BCI) system that can be used by an operator to manipulate external, electrically controlled equipment. Our optical BCI uses near-infrared spectroscopy and functions as a compact, practical, unrestrictive, non-invasive brain-switch. The optical BCI system measured spatiotemporal changes in the hemoglobin concentrations in the blood flow of a subjects prefrontal cortex at 22 measurement points. An exponential moving average (EMA) filter was applied to the data, and then their weighted sum with a taskrelated parameter derived from a pretest is utilized for time-indicated control (GO-STOP) of an external object. In experiments using untrained subjects, the system achieved control patterns within an accuracy of ±6 sec for more than 80% control.


Neurophotonics | 2015

Concurrent fNIRS-fMRI measurement to validate a method for separating deep and shallow fNIRS signals by using multidistance optodes.

Tsukasa Funane; Hiroki Sato; Noriaki Yahata; Yukika Nishimura; Akihide Kinoshita; Takusige Katura; Hirokazu Atsumori; Masato Fukuda; Kiyoto Kasai; Hideaki Koizumi; Masashi Kiguchi

Abstract. It has been reported that a functional near-infrared spectroscopy (fNIRS) signal can be contaminated by extracerebral contributions. Many algorithms using multidistance separations to address this issue have been proposed, but their spatial separation performance has rarely been validated with simultaneous measurements of fNIRS and functional magnetic resonance imaging (fMRI). We previously proposed a method for discriminating between deep and shallow contributions in fNIRS signals, referred to as the multidistance independent component analysis (MD-ICA) method. In this study, to validate the MD-ICA method from the spatial aspect, multidistance fNIRS, fMRI, and laser-Doppler-flowmetry signals were simultaneously obtained for 12 healthy adult males during three tasks. The fNIRS signal was separated into deep and shallow signals by using the MD-ICA method, and the correlation between the waveforms of the separated fNIRS signals and the gray matter blood oxygenation level–dependent signals was analyzed. A three-way analysis of variance (signal depth×Hb kind×task) indicated that the main effect of fNIRS signal depth on the correlation is significant [F(1,1286)=5.34, p<0.05]. This result indicates that the MD-ICA method successfully separates fNIRS signals into spatially deep and shallow signals, and the accuracy and reliability of the fNIRS signal will be improved with the method.


Applied Physics Letters | 2010

Noncontact brain activity measurement system based on near-infrared spectroscopy

Tsukasa Funane; Hirokazu Atsumori; Atsushi Suzuki; Masashi Kiguchi

We have developed a noncontact brain activity measurement system based on near-infrared spectroscopy. With this system,phosphor is placed on the scalp of the forehead and irradiated only by excitation light that has propagated in tissue. Only fluorescence emitted by the phosphor is detected, while the excitation and disturbance lights are cut using optical filters. This configuration resolved the problem of the signal-to-noise ratio loss induced by the disturbance light. The changes in hemoglobin of the human brain were measured during a working memory task, and typical time course data were obtained.


Review of Scientific Instruments | 2011

Optical scanning system for light-absorption measurement of deep biological tissue

Tsukasa Funane; Hirokazu Atsumori; Masashi Kiguchi; Yukari Tanikawa; Eiji Okada

A noncontact near-infrared scanning system for multi-distance absorption measurement of deep biological tissue was developed. An 808-nm laser, whose focal point on the surface of biological tissue is controlled by a galvano scanner, is used as a light source. A phosphor is placed at a detection focal point on the tissue surface. The light that propagates through tissue and exits from the tissue surface beneath the phosphor excites the phosphor. The fluorescence emitted from the phosphor is detected by an avalanche photodiode. The system is used to measure 20 points on tissue surface at which source-detector (S-D) distances are 7-45 mm (with 2-mm intervals). Neither the light source nor the detector contacts the tissue surface. The system was validated by using it to measure the absorption change of an absorber (which is embedded in a deep layer of a tissue-simulating phantom) while the surface-layer thickness of the phantom was changed from 1 to 12 mm. It was demonstrated that both the relative absorption change of the absorber and the absolute thickness of the surface layer can be estimated from the measured optical-density change (ΔOD) and the dependence of ΔOD on S-D distance, respectively.

Collaboration


Dive into the Hirokazu Atsumori's collaboration.

Researchain Logo
Decentralizing Knowledge