Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hiroomi Sumida is active.

Publication


Featured researches published by Hiroomi Sumida.


Magnetic Resonance in Medical Sciences | 2018

How to Improve the Conspicuity of Breast Tumors on Computed High b-value Diffusion-weighted Imaging

Takayuki Tamura; Miyuki Takasu; Toru Higaki; Kazushi Yokomachi; Yuji Akiyama; Hiroomi Sumida; Yasushi Nagata; Kazuo Awai

Purpose: The aim of this study was to compare the tumor conspicuity on actual measured diffusion-weighted images (aDWIs) and computed DWI (cDWI) of human breast tumors and to examine, by use of a phantom, whether cDWI improves their conspicuity. Materials and Methods: We acquired DWIs (b-value 0, 700, 1400, 2100, 2800, and 3500 s/mm2) of 148 women with breast tumors. cDWIs with b-values of 1400, 2100, 2800, and 3500 s/mm2 were calculated from aDWI scans where b = 0 and 700 s/mm2; the tumor signal-to-noise ratio (SNR) was compared at each b-value. We also subjected a phantom harboring a breast tumor and mammary glands to DWI. For reference we used two models. The model with b = 0, 1000, 1500, 2000, 2500, and 3000 s/mm2 was our multiple b-value model. In the single b-value model, we applied b = 0 and 1000 s/mm2 and changed the number of excitations (NEX). cDWIs were generated at b = 0 and 1000 and used to compare the SNR, the contrast ratio (CR), and the contrast-to-noise ratio (CNR). Results: In the phantom study, the CNR of cDWI generated from high SNR images obtained at lower b-values and a high NEX was outperformed aDWI. However, the CR and CNR on cDWI obtained using the same scanning parameters were inferior to aDWI scans. Similarly, in the clinical study, breast tumor conspicuity was worse on high b-value cDWIs than aDWIs. Conclusion: To improve tumor conspicuity on cDWI, the quality of the source images must be improved. It may easily cause inferior conspicuity to aDWIs if high b-value cDWIs were generated from insufficient SNR images.


American Journal of Roentgenology | 2004

Validation of Dental Panoramic Radiography Measures for Identifying Postmenopausal Women with Spinal Osteoporosis

Akira Taguchi; Yoshikazu Suei; Mitsuhiro Sanada; Masahiko Ohtsuka; Takashi Nakamoto; Hiroomi Sumida; Koso Ohama; Keiji Tanimoto


Japanese Journal of Radiological Technology | 2018

Differentiation between Hepatic Focal Lesions and Heterogenous Physiological Accumulations by Early Delayed Scanning in 18 F-FDG PET/CT Examination

Ayaka Ushio; Komei Takauchi; Makoto Kobayashi; Nobukazu Abe; Hiroomi Sumida; Yasushi Nagata; Kazuo Awai


The Journal of Nuclear Medicine | 2013

A new administration dose index for optimization of acquisition time at PET imaging using count data using an ionization type survey meter

Koumei Takauchi; Ayaka Ushio; Nobukazu Abe; Minoru Ishifuro; Hiroomi Sumida; Daisuke Komoto; Kazuo Awai


Japanese Journal of Radiological Technology | 2005

Medical Information Systems in Oral and Maxillofacial Region(Medical Informatics)

Hiroomi Sumida


Japanese Journal of Radiological Technology | 2002

Digital sampling limitation on the dental radiograph(Report from the Scientific Research Group)

Hiroomi Sumida


Japanese Journal of Radiological Technology | 1997

Development and Operation of Order Entry System for Oral and Maxillofacial Radiology

Masahiko Ohtsuka; Noriaki Morimoto; Hideaki Amano; Hiroomi Sumida; Yumiko Yamane; Hiromoto Utsumi; Keiji Tanimoto


Japanese Journal of Radiological Technology | 1996

A Study of Relative Fluorescences and Relative Speeds of Radiographic Screens

Hiroomi Sumida; Akiyoshi Ohtsuka; Ken-Ichi Yoshida; Yoshiharu Higashida; Noboru Katsuda; Yasuhiro Hiai; Akira Yoshida; Masaki Asahara; Yoshie Kodera; Masahiko Ohtsuka; Tadashi Sunayashiki


Japanese Journal of Radiological Technology | 1996

Absolute speeds of screen-film systems measured in six facilities

Ken-Ichi Yoshida; Akiyoshi Ohtsuka; Z. Higashida; Yasunori Murakami; Masaki Asahara; Junji Morishita; Mitsugi Honda; Yoshie Kodera; Akira Yoshida; Hiroomi Sumida; Masahiko Ohtsuka


Japanese Journal of Radiological Technology | 1995

Attempt to apply New Type films at Panoramic Radiography

Hiroomi Sumida; Masahiko Ohtsuka; Tadashi Sunayashiki; Yumiko Yamane; Takurou Wada; Yoshie Kodera

Collaboration


Dive into the Hiroomi Sumida's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge