Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hirotsugu Muratsu is active.

Publication


Featured researches published by Hirotsugu Muratsu.


American Journal of Sports Medicine | 2007

In Vivo Measurement of the Pivot-Shift Test in the Anterior Cruciate Ligament–Deficient Knee Using an Electromagnetic Device

Yuichi Hoshino; Ryosuke Kuroda; Kouki Nagamune; Masayoshi Yagi; Kiyonori Mizuno; Motoi Yamaguchi; Hirotsugu Muratsu; Shinichi Yoshiya; Masahiro Kurosaka

Background The pivot-shift test is commonly used for assessing dynamic instability in anterior cruciate ligament—insufficient knees, which is related to subjective knee function, unlike static load-displacement measurement. Conventional measurements of 3-dimensional position displacement cannot assess such dynamic instability in vivo and produce comparable parameters. Not only 3-dimensional position displacement but also its 3-dimensional acceleration should be measured for quantitative evaluation of the pivot-shift test. Hypothesis Knees with a positive pivot-shift test result have increased tibial anterior translation and acceleration of its subsequent posterior translation, and they are correlated with clinical grading. Study Design Controlled laboratory study. Materials and Methods Thirty patients with isolated anterior cruciate ligament injury were included. Pivot-shift tests were evaluated under anesthesia manually and experimentally using an electromagnetic knee 6 degrees of freedom measurement system. From 60 Hz of 6 degrees of freedom data, coupled tibial anterior translation was calculated, and acceleration of posterior translation was computed by secondary derivative. Results All anterior cruciate ligament—deficient knees demonstrated a positive pivot-shift test result. The coupled tibial anterior translation was 7.7 and 15.6 mm in anterior cruciate ligament—intact and —deficient knees, respectively. The acceleration of posterior translation was —797 and —2001 mm/s 2, respectively. These differences were significant (P < .01). The coupled tibial anterior translation and acceleration of posterior translation in the anterior cruciate ligament—deficient knee were larger in correlation with clinical grading (P = .03 and P < .01, respectively). Conclusion The increase of tibial anterior translation and acceleration of subsequent posterior translation could be detected in knees with a positive pivot-shift result, and this increase was correlated to clinical grading. Clinical Relevance These measurements can be used for quantified evaluation of dynamic instability demonstrated by the pivot-shift test.


Journal of Biomechanical Engineering-transactions of The Asme | 2006

Joint gap kinematics in posterior-stabilized total knee arthroplasty measured by a new tensor with the navigation system.

Tomoyuki Matsumoto; Hirotsugu Muratsu; Nobuhiro Tsumura; Kiyonori Mizuno; Ryosuke Kuroda; Shinichi Yoshiya; Masahiro Kurosaka

BACKGROUND The management of soft tissue balance during surgery is essential for the success of total knee arthroplasty (TKA) but remains difficult, leaving it much to the surgeons feel. Previous assessments for soft tissue balance have been performed under unphysiological joint conditions, with patellar eversion and without the prosthesis only at extension and 90 deg of flexion. We therefore developed a new tensor for TKA procedures, enabling soft tissue balance assessment throughout the range of motion while reproducing postoperative joint alignment with the patellofemoral (PF) joint reduced and the tibiofemoral joint aligned. Our purpose in the present study was to clarify joint gap kinematics using the tensor with the CT-free computer assisted navigation system. METHOD OF APPROACH Joint gap kinematics, defined as joint gap change during knee motion, was evaluated during 30 consecutive, primary posterior-stabilized (PS) TKA with the navigation system in 30 osteoarthritic patients. Measurements were performed using a newly developed tensor, which enabled the measurement of the joint gap throughout the range of motion, including the joint conditions relevant after TKA with PF joint reduced and trial femoral component in place. Joint gap was assessed by the tensor at full extension, 5 deg, 10 deg, 15 deg, 30 deg, 45 deg, 60 deg, 90 deg, and 135 deg of flexion with the patella both everted and reduced. The navigation system was used to obtain the accuracy of implantations and to measure an accurate flexion angle of the knee during the intraoperative joint gap measurement. RESULTS Results showed that the joint gap varied depending on the knee flexion angle. Joint gap showed an accelerated decrease during full knee extension. With the PF joint everted, the joint gap increased throughout knee flexion. In contrast, the joint gap with the PF joint reduced increased with knee flexion but decreased after 60 deg of flexion. CONCLUSIONS We clarified the characteristics of joint gap kinematics in PS TKA under physiological and reproducible joint conditions. Our findings can provide useful information for prosthetic design and selection and allow evaluation of surgical technique throughout the range of knee motion that may lead to consistent clinical outcomes after TKA.


Clinical Orthopaedics and Related Research | 2000

Graft healing in the bone tunnel in anterior cruciate ligament reconstruction

Shinichi Yoshiya; Masanori Nagano; Masahiro Kurosaka; Hirotsugu Muratsu; Kosaku Mizuno

The histologic sequence in the bone tunnel after anterior cruciate ligament reconstruction using the bone-patellar tendon-bone graft was investigated in this study. Eighteen adult mongrel dogs were used. After excision of the anterior cruciate ligament, the graft was routed through the bone tunnels and fixed with interference fit screws. After the dogs were sacrificed at intervals, the bone blocks containing the bone tunnels were isolated and processed for histologic examination. At the bone-bone interface, incorporation of the bone plug at each end of the graft was completed at 12 weeks. The structure of the tendon insertion of the grafted patellar tendon, consisting of four distinct zones, was observed without apparent necrotic and degenerative change for as long as 12 weeks. Between the tendon and the bone tunnel, a layer of hypercellular fibrous tissue gradually became mature with time. Thus, it appeared the morphologic characteristics and location of the reestablished attachment of the bone-patellar tendon-bone graft were more similar to those of the native anterior cruciate ligament compared with the graft to bone healing in the hamstring tendon graft.


Clinical Orthopaedics and Related Research | 2007

Reliability and usefulness of a new in vivo measurement system of the pivot shift.

S. Kubo; Hirotsugu Muratsu; Shinichi Yoshiya; Kiyonori Mizuno; Masahiro Kurosaka

Residual pivot shift after ACL reconstruction is a crucial factor related to poor clinical outcome. However, no method exists that is able to evaluate pivot shift quantitatively and noninvasively. We propose a new measurement system for the pivot shift test using an electromagnetic device and have evaluated its reliability and clinical usefulness. Posterior translation, lateral translation and maximum velocity during the reduction phase of pivot shift were calculated and used as parameters for evaluation. In measurement system analysis, discrepancies of motion between the bones and the sensors were minimal, while reproducibility in repeated measurement was acceptable. Next, clinical usefulness was evaluated by correlating the values obtained by kinematic measurement with the clinical grade. We found differences in each of the measured parameters among clinical grades. These data suggest the system is a valuable measurement tool for clinical evaluation of the pivot shift test.Level of Evidence: Level II, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.


American Journal of Sports Medicine | 2006

A Comparison of Bone–Patellar Tendon–Bone and Bone–Hamstring Tendon–Bone Autografts for Anterior Cruciate Ligament Reconstruction

Akio Matsumoto; Shinichi Yoshiya; Hirotsugu Muratsu; Masayoshi Yagi; Yasunobu Iwasaki; Masahiro Kurosaka; Ryosuke Kuroda

Background Most of the previous comparative studies between patellar tendon and hamstring tendon anterior cruciate ligament grafts compared grafts of different constructs fixed with different methods. Purpose To compare patellar tendon and hamstring tendon grafts with the same fixation method used to reconstruct the anterior cruciate ligament. Study Design Randomized controlled trial; Level of evidence, 1. Methods During the reconstructive procedure, the hamstring tendon graft was prepared as a bone-hamstring-bone graft; both bone-patellar tendon-bone and bone-hamstring-bone grafts were fixed with interference screws. Eighty consecutive patients who underwent anterior cruciate ligament reconstruction were randomly assigned to either bone-patellar tendon-bone or bone-hamstring-bone groups. Follow-up examinations were performed for at least 5 years postoperatively. Seventy-two of the 80 patients (37 patients in the bone-patellar tendon-bone group and 35 in the bone-hamstring-bone group) were evaluated, with a mean follow-up period of 87.0 and 80.8 months, respectively. Follow-up examinations were performed using the International Knee Documentation Committee knee ligament standard and subjective knee forms. Results The mean KT-1000 arthrometer evaluation results showed no significant difference between the bone-patellar tendon-bone and bone-hamstring-bone groups (1.2 ± 2.1 mm and 1.7 ± 1.4 mm, respectively; P =. 24). However, symptoms related to graft harvest (anterior kneeling pain) were more frequently observed in the bone-patellar tendon-bone group, and unsatisfactory results were correlated with severe kneeling pain in 3 patients from this group (P =. 0056). Significant hamstring muscle weakness without complaint of functional deficit was found in the bone-hamstring-bone group (P =. 0045). Conclusion Bone-hamstring-bone grafts were shown to reduce the risk of problems at the graft harvest site compared to bone-patellar tendon-bone grafts, with comparable results in the remaining clinical parameters tested.


Journal of Bone and Joint Surgery-british Volume | 2009

The intra-operative joint gap in cruciate-retaining compared with posterior-stabilised total knee replacement

Tomoyuki Matsumoto; Ryosuke Kuroda; S. Kubo; Hirotsugu Muratsu; Kousaku Mizuno; Masahiro Kurosaka

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0 degrees , 10 degrees , 45 degrees , 90 degrees and 135 degrees of flexion, with the patella both everted and reduced. While the measurement of the joint gap with a reduced patella in posterior-stabilised knees increased from extension to flexion, it remained constant for cruciate-retaining joints throughout a full range of movement. The joint gaps at deep knee flexion were significantly smaller for both types of prosthetic knee when the patellofemoral joint was reduced (p < 0.05).


International Orthopaedics | 2004

Prosthetic alignment and sizing in computer-assisted total knee arthroplasty

Tomoyuki Matsumoto; Nobuhiro Tsumura; Masahiro Kurosaka; Hirotsugu Muratsu; Ryosuke Kuroda; Katsuhiko Ishimoto; Kazuo Tsujimoto; Ryoichi Shiba; Shinichi Yoshiya

We implanted 60 posterior stabilized total knee prostheses (P.F.C. Sigma, DePuy, Warsaw, USA). In 30 cases, we used a CT-free navigation system (Vector Vision, Brain LAB, Heimstetten, Germany), and in 30 matched-paired controls, we used a conventional manual implantation. We compared postoperative long-leg radiographs in the two groups. The results revealed a significant difference in favor of navigation. In addition, we compared the preoperative anteroposterior dimension of the femoral condyle with the postoperative value. While there were no significant differences in the preoperative anteroposterior dimension of the femoral condyle between the two groups, the postoperative value in the navigation group was significantly larger than that of the preoperative value. Therefore, surgeons using navigation systems should guard against the possibility of oversizing when determining the size of the femoral component.RésuméNous avons implanté 60 prothèses totales postéro-stabilisées du genou (P.F.C. Sigma, DePuy). Dans 30 cas nous avons utilisé un système de navigation sans scanner (Vector vision R, Laboratoire du Cerveau, Heimstetten, Allemagne) et dans 30 contrôles appairés nous avons utilisé une implantation manuelle habituelle. Nous avons comparé les grandes radiographies postopératoires des membres inférieurs dans les deux groupes. Les résultats ont révélé une différence notable en faveur de la navigation. De plus nous avons comparé la dimension antéro-postérieure du condyle fémoral avant l’intervention avec la valeur postopératoire. Tandis qu’il n’y avait pas de différence notable dans la dimension antéro-postérieure préopératoire du condyle fémoral entre les deux groupes, la valeur postopératoire dans le groupe de la navigation était nettement plus grande que la valeur préopératoire. Par conséquent les chirurgiens qui utilisent des systèmes de navigation doivent prendre garde à ne pas implanter un composant fémoral sur-dimensionné.


Journal of Arthroplasty | 2009

Soft Tissue Balance Measurement in Posterior-Stabilized Total Knee Arthroplasty With a Navigation System

Tomoyuki Matsumoto; Hirotsugu Muratsu; Nobuhiro Tsumura; Kiyonori Mizuno; Masahiro Kurosaka; Ryosuke Kuroda

Using a tensor for total knee arthroplasty (TKA) that is designed to facilitate soft tissue balance measurements with a reduced patello-femoral joint, we intraoperatively measured the joint gap and ligament balance of 30 osteoarthritic knees at extension and 90 degrees flexion, with the patella both everted and reduced, while performing primary posterior-stabilized TKA. At the same time, we performed the same measurements with a navigation system and identified correlations between this system and the tensor. Specifically, the R(2) values obtained with the knee in extension and 90 degrees flexion were higher with the patella reduced than with the patella everted. We thereby suggest that the navigation system we describe is reliable for obtaining accurate measurements of soft tissue balancing with the patella reduced.


Clinical Biomechanics | 2010

Femoral component placement changes soft tissue balance in posterior-stabilized total knee arthroplasty

Hirotsugu Muratsu; Tomoyuki Matsumoto; S. Kubo; Akihiro Maruo; Hidetoshi Miya; Masahiro Kurosaka; Ryosuke Kuroda

BACKGROUND We developed a new tensor for total knee arthroplasty enabling the soft tissue balance measurement after femoral trial placement with the patello-femoral joint reduced. The purpose of the present study is to compare the measurements of joint gap and ligament balance between osteotomized femoral and tibial surfaces in posterior-stabilized total knee arthroplasty with that between surfaces of femoral trial component and tibial osteotomy. METHODS Using this tensor, the effect of femoral trial placement on the soft tissue balance was analyzed in 80 posterior-stabilized total knee arthroplasties for varus osteoarthritic knees. Both joint gap and varus ligament imbalance were measured with 40 lb of joint distraction force at extension and flexion, and compared between before and after femoral trial placement. FINDINGS In assessing the joint gap, there was significant decrease as much as 5.3mm at extension, not flexion, after femoral trial prosthesis placement. Varus ligament imbalances were significantly reduced with 3.1° at extension and increased with 1.2° in average at flexion after femoral trial placement. INTERPRETATION These changes at extension were caused by tensed posterior structures of the knee with the posterior condyle of the externally rotated aligned femoral trial. At the knee flexion, medial tension in the extensor mechanisms might be increased after femoral trial placement with patello-femoral joint repaired, and increased varus imbalance. Accordingly, we conclude that intensive medial release before femoral component placement to obtain rectangular joint gap depending on the conventional osteotomy gap measurement has a possible risk of medial looseness after total knee arthroplasty.


Knee Surgery, Sports Traumatology, Arthroscopy | 2007

Influence of intra-operative joint gap on post-operative flexion angle in osteoarthritis patients undergoing posterior-stabilized total knee arthroplasty

Tomoyuki Matsumoto; Kiyonori Mizuno; Hirotsugu Muratsu; Nobuhiro Tsumura; Naomasa Fukase; S. Kubo; Shinichi Yoshiya; Masahiro Kurosaka; Ryosuke Kuroda

Recently, we developed a new tensor for total knee arthroplasty (TKA) procedures enabling soft tissue balance assessment throughout the range of motion while reproducing post-operative joint alignment with the patello-femoral (PF) joint reduced and the tibiofemoral joint aligned. Using the tensor with a computer-assisted navigation system, we investigated the relationship between various intra-operative joint gap values and their post-operative flexion angles. An increased value during the extension to flexion gap and a decreased value during the flexion to deep flexion gap with PF joint reduced, not everted, showed an inverse correlation with post-operative knee flexion angle, not pre-operative flexion angle. In conclusion, understanding the characteristics of joint gap kinematics in posterior-stabilized TKA under physiological and reproducible joint conditions may enable the prediction of the post-operative flexion angle and help to determine the appropriate intra-operative joint gap.

Collaboration


Dive into the Hirotsugu Muratsu's collaboration.

Top Co-Authors

Avatar

Masahiro Kurosaka

Toyohashi University of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Tomoyuki Matsumoto

Tokyo University of Agriculture and Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge