Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Hun Wi is active.

Publication


Featured researches published by Hun Wi.


IEEE Transactions on Biomedical Circuits and Systems | 2013

Nanofiber Web Textile Dry Electrodes for Long-Term Biopotential Recording

Tong InOh; Sun Yoon; Tae Eui Kim; Hun Wi; Kap Jin Kim; Eung Je Woo; Rosalind J. Sadleir

Electrode properties are key to the quality of measured biopotential signals. Ubiquitous health care systems require long-term monitoring of biopotential signals from normal volunteers and patients in home or hospital environments. In these settings it is appropriate to use dry textile electrode networks for monitoring purposes, rather than the gel or saline-sponge skin interfaces used with Ag/AgCl electrodes. In this study, we report performance test results of two different electrospun conductive nanofiber webs, and three metal plated fabrics. We evaluated contact impedance, step response, noise and signal fidelity performance indices for all five dry electrodes, and compared them to those of conventional Ag/AgCl electrodes. Overall, we found nanofiber web electrodes matched Ag/AgCl electrode performance more closely than metal plated fabric electrodes, with the contact resistance and capacitance of Ag plated PVDF nanofiber web electrodes being most similar to Ag/AgCl over the 10 Hz to 500 kHz frequency range. We also observed that step responses of all three metal-plated fabrics were poorer than those for nanofiber web electrodes and Ag/AgCl. Further, noise standard deviation and noise power spectral densities were generally lower in nanofiber web electrodes than metal plated fabrics; and waveform fidelity of ECG-like traces recorded from nanofiber web electrodes was higher than for metal plated fabrics. We recommend textile nanofiber web electrodes in applications where flexibility, comfort and durability are required in addition to good electrical characteristics.


Physiological Measurement | 2011

A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2

Tong In Oh; Hun Wi; Do Yub Kim; Pil Joong Yoo; Eung Je Woo

We report the development of a new multi-frequency electrical impedance tomography (EIT) system called the KHU Mark2. It is descended from the KHU Mark1 in terms of technical details such as digital waveform generation, Howland current source with multiple generalized impedance converters and digital phase-sensitive demodulators. New features include flexible electrode configurations to accommodate application-specific requirements, multiple independent current sources and voltmeters for fully parallel operations, improved data acquisition speeds for faster frame rates and compact mechanical design. Given an electrode configuration, we can design an analog backplane in such a way that both current injections and voltage measurements can be done without using any switch. The KHU Mark2 is based on an impedance measurement module (IMM) comprising a current source and a voltmeter. Using multiple IMMs, we can construct a multi-channel system with 16, 32 or 64 channels, for example. Adopting a pipeline structure, it has the maximum data acquisition speed of 100 scans s(-1) with the potential to detect fast physiological changes during respiration and cardiac activity. Measuring both in-phase and quadrature components of trans-impedances at multiple frequencies simultaneously, the KHU Mark2 is apt at spectroscopic EIT imaging. In this paper, we describe its design, construction, calibration and performance evaluation. It has about 84 dB signal-to-noise ratio and 0.5% reciprocity error. Time-difference images of an admittivity phantom are presented showing spectroscopic admittivity images. Future application studies using the KHU Mark2 are briefly discussed.


IEEE Transactions on Biomedical Circuits and Systems | 2014

Multi-Frequency Electrical Impedance Tomography System With Automatic Self-Calibration for Long-Term Monitoring

Hun Wi; Harsh Sohal; Alistair McEwan; Eung Je Woo; Tong In Oh

Electrical Impedance Tomography (EIT) is a safe medical imaging technology, requiring no ionizing or heating radiation, as opposed to most other imaging modalities. This has led to a clinical interest in its use for long-term monitoring, possibly at the bedside, for ventilation monitoring, bleeding detection, gastric emptying and epilepsy foci diagnosis. These long-term applications demand auto-calibration and high stability over long time periods. To address this need we have developed a new multi-frequency EIT system called the KHU Mark2.5 with automatic self-calibration and cooperation with other devices via a timing signal for synchronization with other medical instruments. The impedance measurement module (IMM) for flexible configuration as a key component includes an independent constant current source, an independent differential voltmeter, and a current source calibrator, which allows automatic self-calibration of the current source within each IMM. We installed a resistor phantom inside the KHU Mark2.5 EIT system for intra-channel and inter-channel calibrations of all voltmeters in multiple IMMs. We show the deterioration of performance of an EIT system over time and the improvement due to automatic self-calibration. The system is able to maintain SNR of 80 dB for frequencies up to 250 kHz and below 0.5% reciprocity error over continuous operation for 24 hours. Automatic calibration at least every 3 days is shown to maintain SNR above 75 dB and reciprocity error below 0.7% over 7 days at 1 kHz. A clear degradation in performance results with increasing time between automatic calibrations allowing the tailoring of calibration to suit the performance requirements of each application.


Measurement Science and Technology | 2012

Performance evaluation of wideband bio-impedance spectroscopy using constant voltage source and constant current source

Youssoufa Mohamadou; Tong In Oh; Hun Wi; Harsh Sohal; Adnan Farooq; Eung Je Woo; Alistair McEwan

Current sources are widely used in bio-impedance spectroscopy (BIS) measurement systems to maximize current injection for increased signal to noise while keeping within medical safety specifications. High-performance current sources based on the Howland current pump with optimized impedance converters are able to minimize stray capacitance of the cables and setup. This approach is limited at high frequencies primarily due to the deteriorated output impedance of the constant current source when situated in a real measurement system. For this reason, voltage sources have been suggested, but they require a current sensing resistor, and the SNR reduces at low impedance loads due to the lower current required to maintain constant voltage. In this paper, we compare the performance of a current source-based BIS and a voltage source-based BIS, which use common components. The current source BIS is based on a Howland current pump and generalized impedance converters to maintain a high output


Sensors | 2014

Electrical impedance spectroscopy for electro-mechanical characterization of conductive fabrics.

Tushar Kanti Bera; Youssoufa Mohamadou; Kyounghun Lee; Hun Wi; Tong In Oh; Eung Je Woo; Manuchehr Soleimani; Jin Keun Seo

When we use a conductive fabric as a pressure sensor, it is necessary to quantitatively understand its electromechanical property related with the applied pressure. We investigated electromechanical properties of three different conductive fabrics using the electrical impedance spectroscopy (EIS). We found that their electrical impedance spectra depend not only on the electrical properties of the conductive yarns, but also on their weaving structures. When we apply a mechanical tension or compression, there occur structural deformations in the conductive fabrics altering their apparent electrical impedance spectra. For a stretchable conductive fabric, the impedance magnitude increased or decreased under tension or compression, respectively. For an almost non-stretchable conductive fabric, both tension and compression resulted in decreased impedance values since the applied tension failed to elongate the fabric. To measure both tension and compression separately, it is desirable to use a stretchable conductive fabric. For any conductive fabric chosen as a pressure-sensing material, its resistivity under no loading conditions must be carefully chosen since it determines a measurable range of the impedance values subject to different amounts of loadings. We suggest the EIS method to characterize the electromechanical property of a conductive fabric in designing a thin and flexible fabric pressure sensor.


International Journal of Hyperthermia | 2014

Fast conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) for RF ablation monitoring

Oh In Kwon; Munish Chauhan; Hyung Joong Kim; Woo Chul Jeong; Hun Wi; Tong In Oh; Eung Je Woo

Abstract Purpose: This study shows the potential of magnetic resonance electrical impedance tomography (MREIT) as a non-invasive RF ablation monitoring technique. Materials and methods: We prepared bovine muscle tissue with a pair of needle electrodes for RF ablation, a temperature sensor, and two pairs of surface electrodes for conductivity image reconstructions. We used the injected current non-linear encoding with multi-echo gradient recalled echo (ICNE-MGRE) pulse sequence in a series of MREIT scans for conductivity imaging. We acquired magnetic flux density data induced by externally injected currents, while suppressing other phase artefacts. We used an 8-channel RF head coil and 8 echoes to improve the signal-to-noise ratio (SNR) in measured magnetic flux density data. Using the measured data, we reconstructed a time series of 180 conductivity images at every 10.24 s during and after RF ablation. Results: Tissue conductivity values in the lesion increased with temperature during RF ablation. After reaching 60 °C, a steep increase in tissue conductivity values occurred with relatively little temperature increase. After RF ablation, tissue conductivity values in the lesion decreased with temperature, but to values different from those before ablation due to permanent structural changes of tissue by RF ablation. Conclusion: We could monitor temperature and also structural changes in tissue during RF ablation by producing spatio-temporal maps of tissue conductivity values using a fast MREIT conductivity imaging method. We expect that the new monitoring method could be used to estimate lesions during RF ablation and improve the efficacy of the treatment.


Measurement Science and Technology | 2014

Evaluation of a multi-electrode bioimpedance spectroscopy tensor probe to detect the anisotropic conductivity spectra of biological tissues

Bishal Karki; Hun Wi; Alistair McEwan; Hyeuknam Kwon; Tong In Oh; Eung Je Woo; Jin Keun Seo

This paper presents bioimpedance spectroscopy measurements of anisotropic tissues using a 16 electrode probe and reconstruction method of estimating the anisotropic impedance spectrum in a local region just underneath the center of the probe. This may enable in-vivo surface bioimpedance measurements with similar performance to the ex-vivo gold standard that requires excising and placing the entire tissue sample in a unit measurement cell with uniform electric field. The multiple surface electrodes enable us to create a focused current pattern so that the resulting measured voltage is more sensitive to a local region and less sensitive to other areas. This is exploited in a reconstruction method to provide improved bioimpedance and anisotropy measurements. In this paper, we describe the current pattern for localized electrical energy concentration, performance with the spring loaded pin electrodes, data calibration and experimental results on anisotropic agar phantoms and different tissue types. The anisotropic conductivity spectra are able to differentiate insulating films of different thickness and detect their orientation. Bioimpedance spectra of biological tissues are in agreement with published data and reference instruments. The anisotropy expressed as the ratio of eigenvalues and the orientation of eigenfunctions were reconstructed at 45° intervals. This information is used to predict the underlying anisotropy of the region under the probe. Tissue measurements clearly demonstrate the expected higher anisotropy of muscle tissue compared to liver tissue and spectral changes.


Bioelectromagnetics | 2015

Real-time conductivity imaging of temperature and tissue property changes during radiofrequency ablation: An ex vivo model using weighted frequency difference

Hun Wi; Alistair McEwan; Vincent W. T. Lam; Hyung Joong Kim; Eung Je Woo; Tong In Oh

We demonstrated the feasibility of time difference and weighted frequency difference conductivity imaging for real-time monitoring of temperature distribution and ablation region estimation during radiofrequency (RF) ablation. The electrical conductivity spectrum of biological tissue reflects mobility of ions in intra- and extra-cellular fluids and changes in cellular morphology induced by heating. The time series conductivity spectra were measured in an ex vivo bovine liver by a high-speed electrical impedance tomography (EIT) system. The EIT system was protected by filters to suppress RF energy and allow interleaved real-time imaging. We recorded time and weighted frequency-difference conductivity images and direct temperature variations at the ablation region and control region during 8 min ablation and for the following 66 min of cooling. Conductivity variation in regions of interest was compared with temperature recordings. Contours of conductivity change were visualized and compared to estimate the ablation area. EIT images confirmed increase of conductivity at all frequencies and loss of frequency conductivity change associated with loss of cellular structure. Time difference conductivity images showed changes due to both heating during ablation and heat dissipation following ablation together with tissue property changes. Weighted frequency-difference images presented persistent changes following heating due to the morphological change in the ablation zone.


Biomedical Engineering Online | 2014

Design of a microscopic electrical impedance tomography system for 3D continuous non-destructive monitoring of tissue culture

Eun Jung Lee; Hun Wi; Alistair McEwan; Adnan Farooq; Harsh Sohal; Eung Je Woo; Jin Keun Seo; Tong In Oh

BackgroundNon-destructive continuous monitoring of regenerative tissue is required throughout the entire period of in vitro tissue culture. Microscopic electrical impedance tomography (micro-EIT) has the potential to monitor the physiological state of tissues by forming three-dimensional images of impedance changes in a non-destructive and label-free manner. We developed a new micro-EIT system and report on simulation and experimental results of its macroscopic model.MethodsWe propose a new micro-EIT system design using a cuboid sample container with separate current-driving and voltage sensing electrodes. The top is open for sample manipulations. We used nine gold-coated solid electrodes on each of two opposing sides of the container to produce multiple linearly independent internal current density distributions. The 360 voltage sensing electrodes were placed on the other sides and base to measure induced voltages. Instead of using an inverse solver with the least squares method, we used a projected image reconstruction algorithm based on a logarithm formulation to produce projected images. We intended to improve the quality and spatial resolution of the images by increasing the number of voltage measurements subject to a few injected current patterns. We evaluated the performance of the micro-EIT system with a macroscopic physical phantom.ResultsThe signal-to-noise ratio of the developed micro-EIT system was 66 dB. Crosstalk was in the range of -110.8 to -90.04 dB. Three-dimensional images with consistent quality were reconstructed from physical phantom data over the entire domain. From numerical and experimental results, we estimate that at least 20 × 40 electrodes with 120 μm spacing are required to monitor the complex shape of ingrowth neotissue inside a scaffold with 300 μm pore.ConclusionThe experimental results showed that the new micro-EIT system with a reduced set of injection current patterns and a large number of voltage sensing electrodes can be potentially used for tissue culture monitoring. Numerical simulations demonstrated that the spatial resolution could be improved to the scale required for tissue culture monitoring. Future challenges include manufacturing a bioreactor-compatible container with a dense array of electrodes and a larger number of measurement channels that are sensitive to the reduced voltage gradients expected at a smaller scale.


Biomedical Engineering Online | 2014

Electrical impedance imaging system using FPGAs for flexibility and interoperability.

Harsh Sohal; Hun Wi; Alistair McEwan; Eung Je Woo; Tong In Oh

BackgroundModern EIT systems require simultaneously operating multiple functions for flexibility, interoperability, and clinical applicability. To implement versatile functions, expandable design and implementation tools are needed. On the other hand, it is necessary to develop an ASIC-based EIT system to maximize its performance. Since the ASIC design is expensive and unchangeable, we can use FPGAs as a prior step to the digital ASIC design and carefully classify which functions should be included in the ASIC. In this paper, we describe the details of the FPGA design adopted in the KHU Mark2.5 EIT system.MethodsWe classified all functions of the KHU Mark2.5 EIT system into two categories. One is the control and processing of current injection and voltage measurement. The other includes the collection and management of the multi-channel data with timing controls for internal and external interconnections. We describe the implementation of these functions in two kinds of FPGAs called the impedance measurement module (IMM) FPGA and the intra-network controller FPGA.ResultsWe present functional and timing simulations of the key functions in the FPGAs. From phantom and animal imaging experiments, we show that multiple functions of the system are successfully implemented in the FPGAs. As examples, we demonstrate fast multi-frequency imaging and ECG-gated imaging.ConclusionGiven an analog design of a parallel EIT system, it is important to optimize its digital design to minimize systematic artifacts and maximize performance. This paper described technical details of the FPGA-based fully parallel EIT system called the KHU Mark2.5 with numerous functions needed for clinical applications. Two kinds of FPGAs described in this paper can be used as a basis for future EIT digital ASIC designs for better application-specific human interface as well as hardware performance.

Collaboration


Dive into the Hun Wi's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge