Hyung Tae Kim
Korea University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Hyung Tae Kim.
Korean Journal of Air-Conditioning and Refrigeration Engineering | 2013
Ki-Cheol Kim; Gen-Soo Song; Hyung Tae Kim; Kyung-Hoon Yoo; Dae-Kun Shin; Dug-Jun Park
For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.
Korean Journal of Air-Conditioning and Refrigeration Engineering | 2012
Ki-Cheol Kim; Hyung Tae Kim; Gen-Soo Song; Kyung-Hoon Yoo; Seung-Woo Son; Dae-Kun Shin; Dug-Jun Park
In recent large-scale semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems to heat, humidify, cool and dehumidify incoming outdoor air represents about 45% of the total air conditioning load required to maintain a clean room environment. Therefore, the energy performance evaluation and analysis of outdoor air conditioning systems is useful for reducing the outdoor air conditioning load for a clean room. In the present study, an experiment was conducted to compare the energy consumption of outdoor air conditioning systems with a simple air washer, an exhaust air heat recovery type air washer and a DCC return water heat recovery type air washer. It was shown from the present lab-scale experiment with an outdoor air flow of 1,000 that the exhaust air heat recovery type and DCC return water heat recovery type air washer outdoor air conditioning systems were more energy-efficient for the summer and winter operations than the simple air washer outdoor air conditioning system and furthermore, the DCC return water heat recovery type one was the most energy-efficient in the winter operation.
Transactions of The Korean Society of Mechanical Engineers B | 2011
Hyung Tae Kim; Gen Soo Song; Ki-Cheol Kim; Kyung Hoon Yoo; Seung Woo Son; Dae Kun Shin; Dug Jun Park; Oh Myung Kwon
ABSTRACT:For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidifica-tion type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.Keywords:Clean room(클린룸), Outdoor air conditioning system(외기공조시스템), Annual energy consumption(연간 에너지 소비량), Steam humidification(증기가습), Water spray humidification(수분무가습)
Transactions of The Korean Society of Mechanical Engineers B | 2013
Ki-Cheol Kim; Gen-Soo Song; Hyung Tae Kim; Kyung-Hoon Yoo; Jeong-Jin Kang; Jun-Young Hwang; Sang-Ho Lee; Kyungtae Kang; Heuiseok Kang; Youngjune Cho
AZO (aluminum-doped zinc oxide) is one of the best candidate materials to replace ITO (indium tin oxide) for TCOs (transparent conductive oxides) used in flat panel displays, organic light-emitting diodes (OLEDs), and organic solar cells (OSCs). In the present study, to apply an AZO thin film to the transparent electrode of an organic solar cell, a low-temperature selective atomic layer deposition (ALD) process was adopted to deposit an AZO thin film on a flexible poly-ethylene-naphthalate (PEN) substrate. The reactive gases for the ALD process were di-ethyl-zinc (DEZ) and tri-methyl-aluminum (TMA) as precursors and H2O as an oxidant. The structural, electrical, and optical characteristics of the AZO thin film were evaluated. From the measured results of the electrical and optical characteristics of the AZO thin films deposited on the PEN substrates by ALD, it was shown that the AZO thin film appeared to be comparable to a commercially used ITO thin film, which confirmed the feasibility of AZO as a TCO for flexible organic solar cells in the near future.
Korean Journal of Air-Conditioning and Refrigeration Engineering | 2010
Gen-Soo Song; Hyung Tae Kim; Kyung-Hoon Yoo; Seung-Woo Son; Dae-Kun Shin; Young-Il Kim
Journal of the Korean Physical Society | 2001
Sun Il Shim; Keun Tae Kim; Kwang Moo Kim; Hyung Dae Kim; Seong Eun Kim; Hyung Tae Kim; Jung Ho Park; Deok Ha Woo
Archive | 2016
김승택; Seung Taek Kim; 박문수; Moon Soo Park; 김종석; Jongseok Kim; 김형태; Hyung Tae Kim
Archive | 2015
김승택; Seung Taek Kim; 김종석; Jongseok Kim; 강희석; Heui Seok Kang; 강경태; Kyung Tae Kang; 김형태; Hyung Tae Kim; 박문수; Moon Soo Park
/data/revues/00165107/unassign/S0016510715024359/ | 2015
Jin Young Yoon; Hyung Tae Kim; Sung Pil Hong; Hyun Gun Kim; Jin-Oh Kim; Dong-Hoon Yang; Dong Il Park; Seun Ja Park; Hyun-Soo Kim; Bora Keum; Cheol Hee Park; Chang Soo Eun; Suck-Ho Lee; Il Hyun Baek; Dong Kyung Chang; Tae Il Kim
#N#Third International Conference on Advances in Computing, Electronics and Communication - ACEC 2015#N# | 2015
Hyung Tae Kim; Jongseok Kim; Kyung-Chan Jin; Moonsoo Park; Seungtaek Kim