Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where I. Israelashvili is active.

Publication


Featured researches published by I. Israelashvili.


Journal of Instrumentation | 2012

A novel liquid-Xenon detector concept for combined fast-neutrons and gamma imaging and spectroscopy

A. Breskin; I. Israelashvili; M. Cortesi; L. Arazi; S. Shchemelinin; R. Chechik; V. Dangendorf; B. Bromberger; D. Vartsky

A new detector concept is presented for combined imaging and spectroscopy of fast-neutrons and gamma rays. It comprises a liquid-Xenon (LXe) converter and scintillator coupled to a UV-sensitive gaseous imaging photomultiplier (GPM). Radiation imaging is obtained by localization of the scintillation-light from LXe with the position-sensitive GPM. The latter comprises a cascade of Thick Gas Electron Multipliers (THGEM), where the first element is coated with a CsI UV-photocathode. We present the concept and provide first model-simulation results of the processes involved and the expected performances of a detector having a LXe-filled capillaries converter. The new detector concept has potential applications in combined fast-neutron and gamma-ray screening of hidden explosives and fissile materials with pulsed sources.


Journal of Instrumentation | 2015

A comprehensive simulation study of a Liquid-Xe detector for contraband detection

I. Israelashvili; M. Cortesi; David Vartsky; L. Arazi; D. Bar; E. N. Caspi; A. Breskin

Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier (THGEM)-based imaging photomultiplier (GPM). In this work we present and discuss the results of a systematic computer-simulation study aiming at optimizing the type and performance of LXe converter. We have evaluated the detector spectral response, detection efficiency and spatial resolution for gamma-rays and neutrons in the energy range of 2-15 MeV for 50 mm thick converters consisting of plain LXe volume and LXe-filled capillaries, of Teflon, Polyethylene or hydrogen-containing Teflon (Tefzel). Neutron detection efficiencies for plain LXe, Teflon-capillaries and Tefzel-capillaries converters were about 20% over the entire energy range. In polyethylene capillaries converters the neutron detection efficiency was about 10% at 2 MeV and increased up to about 20% at 14 MeV. Detection efficiencies of gammas in Teflon, Tefzel and polyethylene converters were ~35%. The plain-LXe converter provided the highest gamma-ray detection efficiency, of ~40-50% for 2-15 MeV energy range. Optimization of LXe-filled Tefzel capillary dimensions resulted in spatial resolution of ~1.5mm (FWHM) for neutrons and up to 3.5 mm (FWHM) for gamma-rays. Simulations of radiographic images of various materials using two discrete energy gamma-rays (4.4 MeV and 15.1 MeV) and neutrons in broad energy range (2-10 MeV) were performed in order to evaluate the potential of elemental discrimination.


Applied Radiation and Isotopes | 2016

Quantitative discrimination between oil and water in drilled bore cores via Fast-Neutron Resonance Transmission Radiography.

David Vartsky; Mark Goldberg; V. Dangendorf; I. Israelashvili; Ilan Mor; D. Bar; K. Tittelmeier; M. Weierganz; B. Bromberger; A. Breskin

A novel method utilizing the Fast Neutron Resonance Transmission Radiography is proposed for non-destructive, quantitative determination of the weight percentages of oil and water in cores taken from subterranean or underwater geological formations. The ability of the method to distinguish water from oil stems from the unambiguously-specific energy dependence of the neutron cross-sections for the principal elemental constituents. Monte-Carlo simulations and initial results of experimental investigations indicate that the technique may provide a rapid, accurate and non-destructive method for quantitative evaluation of core fluids in thick intact cores, including those of tight shales for which the use of conventional core analytical approaches appears to be questionable.


Journal of Instrumentation | 2017

Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier

I. Israelashvili; A. E. C. Coimbra; David Vartsky; L. Arazi; S. Shchemelinin; E. N. Caspi; A. Breskin

Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe converter/scintillator, coupled to a triple-THGEM imaging-GPM, with its first electrode coated by a CsI UV-photocathode, operated in Ne/5%CH4 cryogenic temperatures. Radiation localization in 2D was derived from scintillation-induced photoelectron avalanches, measured on the GPMs segmented anode. The localization properties of Co-60 gamma-rays and a mixed fast-neutron/gamma-ray field from an AmBe neutron source were derived from irradiation of a Pb edge absorber. Spatial resolutions of 12+/-2 mm and 10+/-2 mm (FWHM) were reached with Co-60 and AmBe sources, respectively. The experimental results are in good agreement with GEANT4 simulations. The calculated ultimate expected resolutions for our application-relevant 4.4 and 15.1 MeV gamma-rays and 1-15 MeV neutrons are 2-4 mm and ~2 mm (FWHM), respectively. These results indicate the potential applicability of the new detector concept to Fast-Neutron Resonance Radiography (FNRR) and Dual-Discrete-Energy Gamma Radiography (DDEGR) of large objects.


Journal of Instrumentation | 2016

Photoelectron extraction efficiency from a CsI photocathode and THGEM operation in He−CF4 and He−CH4 mixtures

A E C Coimbra; I. Israelashvili; J.M.F. dos Santos

This work presents the experimental measurements obtained for UV-induced photo-electron extraction efficiency from a CsI photocathode into He with CF4 and CH4 gas mixtures. A 1000A CsI photocathode was deposited on a gold plated THGEM for photo-electron conversion. Charge-gain measurements were obtained with a Single-THGEM detector operating in these gas mixtures using a continuous UV lamp for the extraction of photo-electrons. Charge-gains in excess of 105 were obtained for gas mixtures containing percentages of quencher higher than 20% while photo-electron extraction efficiency achieved ~ 50% for He/CF4 and ~ 30% for He/CH4. Single photon electron measurements were also performed to assess the maximal gains reached in this regime. A discussion for future GPM cryogenic applications is presented.


Journal of Instrumentation | 2017

Characterization of THGEM coupled to submillimetric induction gaps in Ne/CH4 and Ar/CH4 mixtures

A E C Coimbra; C.A.O. Henriques; I. Israelashvili; J.A. Mir; J.M.F. dos Santos

The coupling of a THGEM to an induction region having a thickness below 1 mm allows the application of intense induction electric fields, resulting in a more efficient extraction of the avalanche electrons into the anode electrode and the extension of the charge avalanche amplification into the induction region. In the present work, we investigate the performance of such configuration, operating in Ne-5% CH4 and Ar-20% CH4 mixtures, in terms of gain characteristics and energy resolution for 5.9 keV X-rays. Gains above 105 can be achieved in both mixtures without jeopardizing the energy resolution for induction gaps of 0.8 and 0.5 mm, while applying lower biasing voltages to the THGEM. We have demonstrated that it is possible to implement gas electron multiplier configurations having an effective reduction of its thickness and that high gains can be achieved in Ar-based mixtures having CH4 concentrations as high as 20%. Ar based mixtures present higher ionization yields and lower electron diffusion coefficients, when compared to Ne-based ones.


Journal of Instrumentation | 2015

First results of a large-area cryogenic gaseous photomultiplier coupled to a dual-phase liquid xenon TPC

L. Arazi; A E C Coimbra; E. Erdal; I. Israelashvili; M. L. Rappaport; S. Shchemelinin; David Vartsky; J.M.F. dos Santos; A. Breskin


Journal of Physics: Conference Series | 2015

Cryogenic gaseous photomultipliers and liquid hole- multipliers: advances in THGEM-based sensors for future noble-liquid TPCs

L. Arazi; A E C Coimbra; E. Erdal; I. Israelashvili; M. L. Rappaport; S. Shchemelinin; David Vartsky; J.M.F. dos Santos; A. Breskin


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2016

Liquid-Xe detector for contraband detection

David Vartsky; I. Israelashvili; M. Cortesi; L. Arazi; A. E. C. Coimbra; L. Moleri; E. Erdal; D. Bar; M. L. Rappaport; S. Shchemelinin; E. N. Caspi; O. Aviv; A. Breskin


Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2018

Determination of oil and water in drilled bore cores via fast-neutron resonance transmission radiography

D. Vartsky; Mark Goldberg; V. Dangendorf; I. Israelashvili; Ilan Mor; D. Bar; K. Tittelmeier; M. Weierganz; B. Bromberger; A. Breskin

Collaboration


Dive into the I. Israelashvili's collaboration.

Top Co-Authors

Avatar

A. Breskin

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar

David Vartsky

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar

L. Arazi

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar

S. Shchemelinin

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

E. Erdal

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar

M. Cortesi

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar

M. L. Rappaport

Weizmann Institute of Science

View shared research outputs
Top Co-Authors

Avatar

D. Vartsky

Brookhaven National Laboratory

View shared research outputs
Researchain Logo
Decentralizing Knowledge