Astrobiology | 2012
Petr Vítek; Jan Jehlička; Howell G. M. Edwards; Ian B. Hutchinson; Carmen Ascaso; Jacek Wierzchos
Raman spectroscopy is being adopted as a nondestructive instrumentation for the robotic exploration of Mars to search for traces of life in the geological record. Here, miniaturized Raman spectrometers of two different types equipped with 532 and 785 nm lasers for excitation, respectively, were compared for the detection of microbial biomarkers in natural halite from the hyperarid region of the Atacama Desert. Measurements were performed directly on the rock as well as on the homogenized, powdered samples prepared from this material-the effects of this sample preparation and the excitation wavelength employed in the analysis are compared and discussed. From these results, 532 nm excitation was found to be superior for the analysis of powdered specimens due to its high sensitivity toward carotenoids and hence a higher capability for their detection at relatively low concentration in bulk powdered specimens. For the same reason, this wavelength was a better choice for the detection of carotenoids in direct measurements made on the rock samples. The 785 nm excitation wavelength, in contrast, proved to be more sensitive toward the detection of scytonemin.
Astrobiology | 2013
Howell G. M. Edwards; Ian B. Hutchinson; Richard Ingley; John Parnell; Petr Vítek; Jan Jehlička
A novel miniaturized Raman spectrometer is scheduled to fly as part of the analytical instrumentation package on an ESA remote robotic lander in the ESA/Roscosmos ExoMars mission to search for evidence for extant or extinct life on Mars in 2018. The Raman spectrometer will be part of the first-pass analytical stage of the sampling procedure, following detailed surface examination by the PanCam scanning camera unit on the ExoMars rover vehicle. The requirements of the analytical protocol are stringent and critical; this study represents a laboratory blind interrogation of specimens that form a list of materials that are of relevance to martian exploration and at this stage simulates a test of current laboratory instrumentation to highlight the Raman technique strengths and possible weaknesses that may be encountered in practice on the martian surface and from which future studies could be formulated. In this preliminary exercise, some 10 samples that are considered terrestrial representatives of the mineralogy and possible biogeologically modified structures that may be identified on Mars have been examined with Raman spectroscopy, and conclusions have been drawn about the viability of the unambiguous spectral identification of biomolecular life signatures. It is concluded that the Raman spectroscopic technique does indeed demonstrate the capability to identify biomolecular signatures and the mineralogy in real-world terrestrial samples with a very high degree of success without any preconception being made about their origin and classification.
Analytical and Bioanalytical Chemistry | 2012
Howell G. M. Edwards; Ian B. Hutchinson; Richard Ingley
AbstractThe molecular specificity of Raman spectroscopy provides a powerful tool for the analytical interrogation of mineralogical and many biological specimens. The Raman Laser Spectrometer (RLS) is a compact Raman spectrometer under development for deployment on the Martian surface as part of the forthcoming ESA ExoMars mission. This will be the first Raman instrument deployed in space. The scientific interpretation of the data emerging from such an instrument not only addresses the geological and mineral composition of the specimens but also enables an assessment to be made of organic biomaterials that may be preserved in the planetary geological record. The latter evidence centres on the residual and distinctive chemistry relating to the biological adaptation of the geological matrix that has occurred as a result of extremophilic organisms colonizing suitable geological niches for their survival in environmentally stressed habitats on Mars. These biogeological modifications have been studied terrestrially for Mars analogue sites and consist of both a geological component and residual key organic biomarkers, the recognition of which would be a prime factor in life detection surveys of a planetary surface and subsurface. In this paper, the protocols required for the Raman spectral discrimination of key biogeological features that may be detectable on the Martian planetary surface or subsurface are developed using the UK breadboard (UKBB) instrument. This instrument has been constructed to be functionally equivalent to the RLS flight instrument design in order to evaluate the feasible science return of the instrument which will finally be delivered to Mars. Initial Raman measurements using the UKBB are presented and compared with the performance of a commercial laboratory Raman microscope. The initial measurements reported here demonstrate this flight-like prototype achieves straightforward detection of biological signatures contained in geological matrices with Raman band signal to noise ratios high enough to determine sample composition by inspection and without the need for deconvolution or further processing. FigureRaman excitation of sample at 532nm using commercial optical head.
Philosophical Transactions of the Royal Society A | 2014
Ian B. Hutchinson; Richard Ingley; Howell G. M. Edwards; Liam V. Harris; Melissa McHugh; Cédric Malherbe; John Parnell
The first Raman spectrometers to be used for in situ analysis of planetary material will be launched as part of powerful, rover-based analytical laboratories within the next 6 years. There are a number of significant challenges associated with building spectrometers for space applications, including limited volume, power and mass budgets, the need to operate in harsh environments and the need to operate independently and intelligently for long periods of time (due to communication limitations). Here, we give an overview of the technical capabilities of the Raman instruments planned for future planetary missions and give a review of the preparatory work being pursued to ensure that such instruments are operated successfully and optimally. This includes analysis of extremophile samples containing pigments associated with biological processes, synthetic materials which incorporate biological material within a mineral matrix, planetary analogues containing low levels of reduced carbon and samples coated with desert varnish that incorporate both geo-markers and biomarkers. We discuss the scientific importance of each sample type and the challenges using portable/flight-prototype instrumentation. We also report on technical development work undertaken to enable the next generation of Raman instruments to reach higher levels of sensitivity and operational efficiency.
International Journal of Astrobiology | 2012
Howell G. M. Edwards; Ian B. Hutchinson; Richard Ingley
The survival strategies of extremophilic organisms in terrestrially stressed locations and habitats are critically dependent on the production of protective chemicals in response to desiccation, low wavelength radiation insolation, temperature and the availability of nutrients. The adaptation of life to these harsh prevailing conditions involves the control of the substratal geology; the interaction between the rock and the organisms is critical and the biological modification of the geological matrix plays a very significant role in the overall survival strategy. Identification of these biological and biogeological chemical molecular signatures in the geological record is necessary for the recognition of the presence of extinct or extant life in terrestrial and extraterrestrial scenarios. Raman spectroscopic techniques have been identified as valuable instrumentation for the detection of life extra-terrestrially because of the use of non-invasive laser-based excitation of organic and inorganic molecules, and molecular ions with high discrimination characteristics; the interactions effected between biological organisms and their environments are detectable through the molecular entities produced at the interfaces, for which the vibrational spectroscopic band signatures are unique. A very important attribute of Raman spectroscopy is the acquisition of molecular experimental data non-destructively without the need for chemical or mechanical pre-treatment of the specimen; this has been a major factor in the proposal for the adoption of Raman instrumentation on robotic landers and rovers for planetary exploration, particularly for the forthcoming European Space Agency (ESA)/National Aeronautics and Space Administration (NASA) ExoMars mission. In this paper, the merits of using Raman spectroscopy for the recognition of key molecular biosignatures from several terrestrial extremophile specimens will be illustrated. The data and specimens used in this presentation have been acquired from Arctic and Antarctic cold deserts and a meteorite crater, from which it will be possible to assess spectral data relevant for the detection of extra-terrestrial extremophilic life signatures.
Philosophical Transactions of the Royal Society A | 2014
Petr Vítek; Jan Jehlička; Howell G. M. Edwards; Ian B. Hutchinson; Carmen Ascaso; Jacek Wierzchos
This study is primarily focused on proving the potential of miniaturized Raman systems to detect any biomolecular and mineral signal in natural geobiological samples that are relevant for future application of the technique within astrobiologically aimed missions on Mars. A series of evaporites of varying composition and origin from two extremely dry deserts were studied, namely Atacama and Mojave. The samples represent both dry evaporitic deposits and recent evaporitic efflorescences from hypersaline brines. The samples comprise halite and different types of sulfates and carbonates. The samples were analysed in two different ways: (i) directly as untreated rocks and (ii) as homogenized powders. Two excitation wavelengths of miniaturized Raman spectrometers were compared: 532 and 785 nm. The potential to detect carotenoids as biomarkers on Mars compared with the potential detection of carbonaceous matter using miniaturized instrumentation is discussed.
Proceedings of SPIE | 2005
A. Short; Gordon R. Hopkinson; Anouk Laborie; Pierre Pouny; Cyril Vetel; Tim Eaton; Roy Steward; Andrew D. Holland; Ian B. Hutchinson; David R. Smith; Jos de Bruijne; P. Gare; M. A. C. Perryman; Giuseppe Sarri; Igor Zayer
ESAs Gaia astrometry mission is due for launch in 2011. The astrometric instrument focal plane will have an area of up to 0.5m2 and will contain more than 100 CCDs. These will be operated in Time Delay and Integration mode in order to track and observe sources whilst the telescopes continuously scan the sky. Gaias target for astrometric precision of a few millionths of an arc second, places extreme demands on focal plane thermo--mechanical stability and electronics performance. The CCDs themselves are large area, back illuminated, full--frame, four phase devices. They require maximum efficiency for observing the majority of (faint) objects, yet must simultaneously be able to handle very bright objects that will regularly cross the field of view. Achieving the final astrometric precision will also require excellent noise performance and MTF. In addition to demanding excellent performance from each CCD, they will need to be produced in large numbers which raises production and yield issues. When analyzing Gaia data it will be essential to understand and calibrate CCD behaviour correctly, including the expected performance degradation due to radiation damage. This is being addressed through comprehensive testing and the development of CCD models.
Philosophical Transactions of the Royal Society A | 2014
Howell G. M. Edwards; Ian B. Hutchinson; Richard Ingley; Jan Jehlička
The remote robotic exploration of extraterrestrial scenarios for evidence of biological colonization in ‘search for life’ missions using Raman spectroscopy is critically dependent on two major factors: firstly, the Raman spectral recognition of characteristic biochemical spectral signatures in the presence of mineral matrix features; and secondly, the positive unambiguous identification of molecular biomaterials which are indicative of extinct or extant life. Both of these factors are considered here: the most important criterion is the clear definition of which biochemicals truly represent biomarkers, whose presence in the planetary geological record from an analytical astrobiological standpoint will unambiguously be indicative of life as recognized from its remote instrumental interrogation. Also discussed in this paper are chemical compounds which are associated with living systems, including biominerals, which may not in themselves be definitive signatures of life processes and origins but whose presence provides an indicator of potential life-bearing matrices.
Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms | 2003
Richard M. Ambrosi; David R. Smith; A. F. Abbey; Ian B. Hutchinson; E. Kendziorra; A. Short; Andrew D. Holland; M.J.L. Turner; Alan A. Wells
Abstract The University of Tubingen 3.5 MeV Van de Graaff accelerator facility was used to investigate the effect of low-energy protons on the performance of the European Photon Imaging Camera, metal-oxide-semiconductor, charge-coupled devices (CCDs). Two CCDs were irradiated in different parts of their detecting areas using different proton spectra and dose rates. Iron-55 was the calibration source in all cases and was used to measure any increases in charge transfer inefficiency (CTI) and spectral resolution of the CCDs. Additional changes in the CCD bright pixel table and changes in the low X-ray energy response of the device were examined. The Monte Carlo code Stopping Range of Ions in Matter was used to model the effect of a 10 MeV equivalent fluence of protons interacting with the CCD. Since the non-ionising energy loss function could not be applied effectively at such low proton energies. From the 10 MeV values, the expected CTI degradation could be calculated and then compared to the measured CTI changes.
International Journal of Astrobiology | 2014
John Parnell; Sean McMahon; Nigel J.F. Blamey; Ian B. Hutchinson; Liam V. Harris; Richard Ingley; Howell G. M. Edwards; Edward P. Lynch; M. Feely
C. W. Taylor and J. Still are thanked for skilled technical support. J. Parnell, H.G.M. Edwards, I. Hutchinson and R. Ingley acknowledge the support of the UKSA and the STFC Research Council in the UK ExoMars programme. L. V. Harris and S. McMahon acknowledge STFC studentship funding.