Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Ian Munro is active.

Publication


Featured researches published by Ian Munro.


Optics Express | 2000

A low cost adaptive optics system using a membrane mirror

Carl Paterson; Ian Munro; J. C. Dainty

A low cost adaptive optics system constructed almost entirely of commercially available components is presented. The system uses a 37 actuator membrane mirror and operates at frame rates up to 800Hz using a single processor. Numerical modelling of the membrane mirror is used to optimize parameters of the system. The dynamic performance of the system is investigated in detail using a diffractive wavefront generator based on a ferroelectric spatial light modulator. This is used to produce wavefronts with time-varying aberrations. The ability of the system to correct for Kolmogorov turbulence with different strengths and effective wind speeds is measured experimentally using the wavefront generator.


Journal of Cell Biology | 2006

Microclusters of inhibitory killer immunoglobulin–like receptor signaling at natural killer cell immunological synapses

Bebhinn Treanor; Peter M. P. Lanigan; Sunil Kumar; Christopher Dunsby; Ian Munro; Egidijus Auksorius; Fiona J. Culley; Marco A. Purbhoo; David Phillips; Mark A. A. Neil; Deborah N. Burshtyn; Paul M. W. French; Daniel M. Davis

We report the supramolecular organization of killer Ig–like receptor (KIR) phosphorylation using a technique applicable to imaging phosphorylation of any green fluorescent protein–tagged receptor at an intercellular contact or immune synapse. Specifically, we use fluorescence lifetime imaging (FLIM) to report Förster resonance energy transfer (FRET) between GFP-tagged KIR2DL1 and a Cy3-tagged generic anti-phosphotyrosine monoclonal antibody. Visualization of KIR phosphorylation in natural killer (NK) cells contacting target cells expressing cognate major histocompatibility complex class I proteins revealed that inhibitory signaling is spatially restricted to the immune synapse. This explains how NK cells respond appropriately when simultaneously surveying susceptible and resistant target cells. More surprising, phosphorylated KIR was confined to microclusters within the aggregate of KIR, contrary to an expected homogeneous distribution of KIR signaling across the immune synapse. Also, yellow fluorescent protein–tagged Lck, a kinase important for KIR phosphorylation, accumulated in a multifocal distribution at inhibitory synapses. Spatial confinement of receptor phosphorylation within the immune synapse may be critical to how activating and inhibitory signals are integrated in NK cells.


Biophysical Journal | 2008

Multiplexed FRET to image multiple signaling events in live cells.

David M. Grant; Wei Zhang; Ewan J. McGhee; Tom D. Bunney; Clifford Talbot; Sunil Kumar; Ian Munro; Christopher Dunsby; Mark A. A. Neil; Matilda Katan; Paul M. W. French

We report what to our knowledge is a novel approach for simultaneous imaging of two different Förster resonance energy transfer (FRET) sensors in the same cell with minimal spectral cross talk. Previous methods based on spectral ratiometric imaging of the two FRET sensors have been limited by the availability of suitably bright acceptors for the second FRET pair and the spectral cross talk incurred when measuring in four spectral windows. In contrast to spectral ratiometric imaging, fluorescence lifetime imaging (FLIM) requires measurement of the donor fluorescence only and is independent of emission from the acceptor. By combining FLIM-FRET of the novel red-shifted TagRFP/mPlum FRET pair with spectral ratiometric imaging of an ECFP/Venus pair we were thus able to maximize the spectral separation between our chosen fluorophores while at the same time overcoming the low quantum yield of the far red acceptor mPlum. Using this technique, we could read out a TagRFP/mPlum intermolecular FRET sensor for reporting on small Ras GTP-ase activation in live cells after epidermal growth factor stimulation and an ECFP/Venus Cameleon FRET sensor for monitoring calcium transients within the same cells. The combination of spectral ratiometric imaging of ECFP/Venus and high-speed FLIM-FRET of TagRFP/mPlum can thus increase the spectral bandwidth available and provide robust imaging of multiple FRET sensors within the same cell. Furthermore, since FLIM does not require equal stoichiometries of donor and acceptor, this approach can be used to report on both unimolecular FRET biosensors and protein-protein interactions with the same cell.


Optics Letters | 2004

High-speed wide-field time-gated endoscopic fluorescence-lifetime imaging

Jose Requejo-Isidro; J. McGinty; Ian Munro; D. S. Elson; Neil Galletly; M. J. Lever; Mark A. A. Neil; Gordon Stamp; Paul M. W. French; P. A. Kellett; Jonathan D. Hares; A. K. L. Dymoke-Bradshaw

We report the development of a high-speed wide-field fluorescence-lifetime imaging (FLIM) system that provides fluorescence-lifetime images at rates of as many as 29 frames/s. A FLIM multiwell plate reader and a potentially portable FLIM endoscopic system operating at 355-nm excitation have been demonstrated.


PLOS ONE | 2013

Rapid global fitting of large fluorescence lifetime imaging microscopy datasets.

Sean C. Warren; Anca Margineanu; Dominic Alibhai; Douglas J. Kelly; Clifford Talbot; Yuriy Alexandrov; Ian Munro; Matilda Katan; Christopher Dunsby; Paul M. W. French

Fluorescence lifetime imaging (FLIM) is widely applied to obtain quantitative information from fluorescence signals, particularly using Förster Resonant Energy Transfer (FRET) measurements to map, for example, protein-protein interactions. Extracting FRET efficiencies or population fractions typically entails fitting data to complex fluorescence decay models but such experiments are frequently photon constrained, particularly for live cell or in vivo imaging, and this leads to unacceptable errors when analysing data on a pixel-wise basis. Lifetimes and population fractions may, however, be more robustly extracted using global analysis to simultaneously fit the fluorescence decay data of all pixels in an image or dataset to a multi-exponential model under the assumption that the lifetime components are invariant across the image (dataset). This approach is often considered to be prohibitively slow and/or computationally expensive but we present here a computationally efficient global analysis algorithm for the analysis of time-correlated single photon counting (TCSPC) or time-gated FLIM data based on variable projection. It makes efficient use of both computer processor and memory resources, requiring less than a minute to analyse time series and multiwell plate datasets with hundreds of FLIM images on standard personal computers. This lifetime analysis takes account of repetitive excitation, including fluorescence photons excited by earlier pulses contributing to the fit, and is able to accommodate time-varying backgrounds and instrument response functions. We demonstrate that this global approach allows us to readily fit time-resolved fluorescence data to complex models including a four-exponential model of a FRET system, for which the FRET efficiencies of the two species of a bi-exponential donor are linked, and polarisation-resolved lifetime data, where a fluorescence intensity and bi-exponential anisotropy decay model is applied to the analysis of live cell homo-FRET data. A software package implementing this algorithm, FLIMfit, is available under an open source licence through the Open Microscopy Environment.


Biomedical Optics Express | 2010

Wide-field fluorescence lifetime imaging of cancer

James McGinty; Neil Galletly; Christopher Dunsby; Ian Munro; Daniel S. Elson; Jose Requejo-Isidro; Patrizia Cohen; Raida Ahmad; Amanda Forsyth; Andrew V. Thillainayagam; Mark A. A. Neil; Paul M. W. French; Gordon Stamp

Optical imaging of tissue autofluorescence has the potential to provide rapid label-free screening and detection of surface tumors for clinical applications, including when combined with endoscopy. Quantitative imaging of intensity-based contrast is notoriously difficult and spectrally resolved imaging does not always provide sufficient contrast. We demonstrate that fluorescence lifetime imaging (FLIM) applied to intrinsic tissue autofluorescence can directly contrast a range of surface tissue tumors, including in gastrointestinal tissues, using compact, clinically deployable instrumentation achieving wide-field fluorescence lifetime images of unprecedented clarity. Statistically significant contrast is observed between cancerous and healthy colon tissue for FLIM with excitation at 355 nm. To illustrate the clinical potential, wide-field fluorescence lifetime images of unstained ex vivo tissue have been acquired at near video rate, which is an important step towards real-time FLIM for diagnostic and interoperative imaging, including for screening and image-guided biopsy applications.


Optics Express | 2007

High speed optically sectioned fluorescence lifetime imaging permits study of live cell signaling events

David M. Grant; J. McGinty; Ewan J. McGhee; Tom D. Bunney; Dylan M. Owen; Clifford Talbot; Wei Zhang; Sunil Kumar; Ian Munro; Peter M. P. Lanigan; Gordon T. Kennedy; Christopher Dunsby; Anthony I. Magee; Patrick Courtney; M. Katan; Mark A. A. Neil; Paul M. W. French

We present a time domain optically sectioned fluorescence lifetime imaging (FLIM) microscope developed for high-speed live cell imaging. This single photon excited system combines wide field parallel pixel detection with confocal sectioning utilizing spinning Nipkow disc microscopy. It can acquire fluorescence lifetime images of live cells at up to 10 frames per second (fps), permitting high-speed FLIM of cell dynamics and protein interactions with potential for high throughput cell imaging and screening applications. We demonstrate the application of this FLIM microscope to real-time monitoring of changes in lipid order in cell membranes following cholesterol depletion using cyclodextrin and to the activation of the small GTP-ase Ras in live cells using FRET.


Journal of Microscopy | 2005

Imaging fluorescence lifetime heterogeneity applied to GFP-tagged MHC protein at an immunological synapse

Bebhinn Treanor; Peter M. P. Lanigan; Klaus Suhling; T Schreiber; Ian Munro; Mark A. A. Neil; David Phillips; Daniel M. Davis; Paul M. W. French

Fluorescence imaging of green fluorescent protein (GFP) may be used to locate proteins in live cells and fluorescence lifetime imaging (FLIM) may be employed to probe the local microenvironment of proteins. Here we apply FLIM to GFP‐tagged proteins at the cell surface and at an inhibitory natural killer (NK) cell immunological synapse (IS). We present a novel quantitative analysis of fluorescence lifetime images that we believe is useful to determine whether apparent FLIM heterogeneity is statistically significant. We observe that, although the variation of observed fluorescence lifetime of GFP‐tagged proteins at the cell surface is close to the expected statistical range, the lifetime of GFP‐tagged proteins in cells is shorter than recombinant GFP in solution. Furthermore the lifetime of GFP‐tagged major histocompatibility complex class I protein is shortened at the inhibitory NK cell IS compared with the unconjugated membrane. Following our previous work demonstrating the ability of FLIM to report the local refractive index of GFP in solution, we speculate that these lifetime variations may indicate local refractive index changes. This application of our method for detecting small but significant differences in fluorescence lifetimes shows how FLIM could be broadly useful in imaging discrete membrane environments for a given protein.


Journal of Biomedical Optics | 2005

Toward the clinical application of time-domain fluorescence lifetime imaging

Ian Munro; J. McGinty; Neil Galletly; Jose Requejo-Isidro; Peter M. P. Lanigan; D. S. Elson; Christopher Dunsby; Mark A. A. Neil; M. J. Lever; Gordon Stamp; P. M. W. French

High-speed (video-rate) fluorescence lifetime imaging (FLIM) through a flexible endoscope is reported based on gated optical image intensifier technology. The optimization and potential application of FLIM to tissue autofluorescence for clinical applications are discussed.


New Journal of Physics | 2004

Real-time time-domain fluorescence lifetime imaging including single-shot acquisition with a segmented optical image intensifier

D. S. Elson; Ian Munro; Jose Requejo-Isidro; J. McGinty; Christopher Dunsby; Neil Galletly; Gordon Stamp; Mark A. A. Neil; M. J. Lever; P A Kellett; A Dymoke-Bradshaw; J Hares; P. M. W. French

High-speed (video-rate) fluorescence lifetime imaging (FLIM) is reported using two different time-domain approaches based on gated optical image intensifier technology. The first approach utilizes a rapidly switchable variable delay generator with sequential image acquisition, while the second employs a novel segmented gated optical imager to acquire lifetime maps in a single shot. Lifetimes are fitted using both a non-linear least-squares fit analysis and the rapid lifetime determination method. Monte Carlo simulations were used to optimize the acquisition parameters and a comparison between theory and experiment is presented. The importance of single-shot imaging to minimize the deleterious impact of sample movements is highlighted. Real-time FLIM movies of multi-well plate samples and tissue autofluorescence are presented.

Collaboration


Dive into the Ian Munro's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Gordon Stamp

Francis Crick Institute

View shared research outputs
Top Co-Authors

Avatar

D. S. Elson

Imperial College London

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge