Igor Jovanović
University of Niš
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Igor Jovanović.
Measurement Science and Technology | 2016
Marjan Blagojevic; Uglješa Jovanović; Igor Jovanović; Dragan Mančić; Radivoje Popovic
In this paper the realization and optimization of two coreless open-loop bus bar current transducers based on a Hall effect sensor are presented. Two types of bus bar are evaluated: flat rectangular and rectangular with a restrictive region in the middle. Both realized transducers are capable of measuring AC and DC currents up to 300 A and 10 kHz frequency with nonlinearity less than 0.3% in the entire range. Several methods for resolving issues with the skin effect and stray magnetic fields are presented along with the experimental test results. Some of the presented methods are novel and have never been evaluated.
Clinical Oral Implants Research | 2014
Aleksa Markovic; Tijana Mišić; Dragan Mančić; Igor Jovanović; Miodrag Šćepanović; Zoran Jezdic
OBJECTIVES To compare the effect of two surgical techniques, lateral condensation and bone drilling, on changes in temperature of the adjacent low-density bone during implant placement into posterior maxilla and to investigate the influence of the host factors - age, gender, region of implantation, bone density, and thickness of the cortical bone at the recipient sites. MATERIAL AND METHODS Local bone temperature was measured thermographically during implant placement into posterior maxilla following lateral bone condensing (test group) or bone drilling (controls). The main study outcomes were baseline bone temperature prior to implantation and maximum bone temperature recorded during implantation. Early implant success was evaluated after 6 months of healing. RESULTS A total of 40 implants were randomly allocated to test and control groups and placed into maxillary premolar and/or molar region of 18 participants of both genders and average age of 51.74 years. All recorded bone temperatures were below the threshold for thermal necrosis. Although both groups showed significant increase in bone temperature during implant placement procedure (P ≤ 0.0005), it was significantly higher for bone condensing compared with drilling (P ≤ 0.0005; 3.79 ± 1.54°C; 1.91 ± 0.70°C respectively). No host factor was singled out as a significant predictor of bone temperature changes, although trend of higher increase was observed in young patients, regardless of gender, during implant placement procedure into maxillary first premolar region with bone density type 3 and cortical layer thicker than 1 mm. Early implant success rate after 6 months follow-up was 100%. CONCLUSION Although both surgical techniques, bone condensing and bone drilling, can be considered safe regarding their thermal effect on the bone of posterior maxilla, bone drilling is associated with fewer local bone heating during implantation. Host factors do not affect the bone thermal changes significantly.
international conference on telecommunications | 2013
Uglješa Jovanović; Igor Jovanović; Andrija Z. Petrusic; Zoran Petrusic; Dragan Mančić
In this paper a prototype of wireless system for dust density measurement is presented. The system is developed with inexpensive commercially available components and can measure dust density up to 0.5mg/m3. The system is modular and consists of a base station connected to a PC via USB communication and an autonomous sensing node equipped with an optical dust sensor GP2Y1010AU0F. A virtual instrument made in LabVIEW is created to monitor the system operation, data acquisition and data storage.
Serbian Journal of Electrical Engineering | 2018
Igor Jovanović; Uglješa Jovanović; Dragan Mančić
Ultrasonic sandwich transducer is a half-wave resonant structure which oscillates in thickness direction. This paper presents a new Matlab/ Simulink model of a prestressed unsymmetrical ultrasonic sandwich transducer, which is modeled by applying three-dimensional (3D) Matlab/Simulink models of piezoceramic rings and metal endings derived from the piezoceramic ring model. With the cascade connection of the piezoceramic rings model with metal endings model, a complete model of ultrasonic transducer is obtained. Using this model one may determine any transducer transfer function, whereat is taken into the account the external medium influence, as well as the influence of the thickness and radial modes of each transducer component. The electromechanical equivalent circuit of the hammer transducer, which represents onedimensional (1D) model, is also derived and presented in this paper. The comparisons between experimental and theoretical results are quite good and validate the new analytical 3D design approach.
Serbian Journal of Electrical Engineering | 2018
Uglješa Jovanović; Igor Jovanović; Marjan Blagojevic; Dejan Krstić; Dragan Mančić
Electrical Engineering | 2018
Marjan Blagojevic; Uglješa Jovanović; Igor Jovanović; Dragan Mančić
Journal of Electrical Engineering & Technology | 2017
Uglješa Jovanović; Dragan Mančić; Igor Jovanović; Zoran Petrusic
Journal of Computational Electronics | 2017
Igor Jovanović; Dragan Mančić; Uglješa Jovanović; Miodrag Prokić
Facta universitatis. Series electronics and energetics | 2016
Marjan Blagojevic; Uglješa Jovanović; Igor Jovanović; Dragan Mančić; Radivoje Popovic
Facta Universitatis, Series: Working and Living Environmental Protection | 2015
Igor Jovanović; Ljubisa Peric; Uglješa Jovanović; Dragan Mančić