Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Inyoung Song is active.

Publication


Featured researches published by Inyoung Song.


Acta Radiologica | 2014

Detection of cardiac myxomas with non-contrast chest CT

Wonseon Shin; Yeon Hyeon Choe; Sung Mok Kim; Inyoung Song; Sam Soo Kim

Background Cardiac myxomas are sources of systemic embolism. Currently a large volume of chest CT and calcium-scoring CT scans are performed without contrast injection. Purpose To evaluate the diagnostic capability of non-contrast CT covering heart in detecting cardiac myxomas. Material and Methods This retrospective study included 36 non-contrast CT scans of 36 consecutive patients (16 men, 20 women) who underwent CT scan before surgery for left atrial myxomas and 20 patients without myxoma as a control group. Two independent readers who were blinded to medical information reviewed non-contrast CT scans of 36 patients with cardiac myxomas and 20 scans in the control group patients. They determined the presence of lesions suspicious of myxomas using a five-point scale. The other reader measured attenuation number in the non-calcific areas of the tumors and sizes of the masses on the non-contrast CT images. Results The average attenuation of cardiac myxoma (22.5 Hounsfield units [HU]; range, 8.9–32.9 HU) and adjacent unopacified blood (44.6 HU; range, 31.5–57 HU) were significantly different (P < 0.001). Twelve cardiac myxomas (31.6%) had internal calcification and all of them were detected by both of readers. Cardiac myxomas were measured smaller on non-contrast CT (mean, 3.5 cm; range, 1.1–9.7 cm) than on pathologic specimens (mean, 4.1 cm, 1.4–10.0 cm) (P < 0.001). Considering grade 3–5 on a five-grade scale as the detectability, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of non-contrast CT in detecting cardiac myxomas were 88.8%/86.1%, 95.0%/100%, 96.9%/100%, 82.6%/80.0%, and 91.1%/91.1%, by reader 1 and reader 2, respectively and there was good inter-observer reliability (kappa value = 0.92, P = 0.157). Conclusion Non-contrast CT scan is useful for detecting cardiac myxomas. Therefore, radiologists should be familiar with imaging findings of cardiac myxomas on non-contrast CT.


Acta Radiologica | 2013

Digital tomosynthesis of the thorax: the influence of respiratory motion artifacts on lung nodule detection

Sung Mok Kim; Myung Jin Chung; Kyung Soo Lee; Hee Kang; Inyoung Song; Eun Joo Lee; Hye Sun Hwang

Background Digital tomosynthesis considerably reduces problems created by overlapping anatomy compared with chest X-ray (CXR). However, digital tomosynthesis requires a longer scan time compared with CXR, and thus may be vulnerable to motion artifacts. Purpose To compare the diagnostic performance of digital tomosynthesis in subjects with and without respiratory motion artifacts. Material and Methods The institutional review board approved this retrospective study, and the requirement for written informed consent was waived. A total of 46 subjects with imaging containing respiratory motion artifacts were enrolled in this study, 18 of whom were positive and 28 of whom were negative for lung nodules on computed tomography (CT). The control group was comprised of 92 age-matched subjects with imaging devoid of motion artifacts. Of these, 36 were positive and 56 were negative for lung nodules on subsequent CT scan. The size criteria of nodules were 4–10 mm. Three chest radiologists independently evaluated the radiographs and digital tomosynthesis images for the presence of pulmonary nodules. Multireader multicase receiver-operating characteristic (ROC) analyses was used for statistical comparisons. Results Within the control group, the areas under curve (AUC) for observer performances in detecting lung nodules on digital tomosynthesis was higher than that on CXR (P = 0.017). Within the study group, there were no significant differences in AUCs for observer performances (P = 0.576). Conclusion When no motion artifacts are present, the detection performance of nodules (4–10 mm) on digital tomosynthesis is significantly better than that on CXR, whereas there is not a significant difference in cases with motion artifacts.


Korean Journal of Radiology | 2016

Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring.

Inyoung Song; Jeong Geun Yi; Jeong Hee Park; Sung Mok Kim; Kyung Soo Lee; Myung Jin Chung

Objective To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. Materials and Methods This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated VNC images were reconstructed using two kinds of 2-material decomposition algorithms (material density iodine-water pair [MDW], material density iodine-calcium pair [MDC]) and a material suppressed algorithm (material suppressed iodine [MSI]). Two readers independently quantified calcium on VNC and TNC images. The Spearman correlation coefficient test and Bland-Altman method were used for statistical analyses. Results Coronary artery calcium scores from all three VNC images showed excellent correlation with those from the TNC images (Spearmans correlation coefficient [ρ] = 0.94, 0.88, and 0.89 for MDW, MDC, and MSI, respectively; p < 0.001 for all pairs). Measured coronary calcium volumes from VNC images also correlated well with those from TNC images (ρ = 0.92, 0.87, and 0.91 for MDW, MDC, and MSI, respectively; p < 0.001 for all pairs). Among the three VNC images, coronary calcium from MDW correlated best with that from TNC. The coronary artery calcium scores and volumes were significantly lower from the VNC images than from the TNC images (p < 0.001 for all pairs). Conclusion The use of VNC images from contrast-enhanced CT using dual-energy material decomposition/suppression is feasible for coronary calcium scoring. The absolute value from VNC tends to be smaller than that from TNC.


Acta Radiologica | 2015

Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT:

Young So; Jeong Geun Yi; Inyoung Song; Won Woo Lee; Hyun Woo Chung; Jeong Hee Park; Sung Gyu Moon

Background Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. Purpose To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. Material and Methods We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Results Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P < 0.005). On average, 2.6 more organs with concomitant metastases were found when SMM was revealed by PET-CT. Conclusion The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM.


PLOS ONE | 2016

Indirect CT Venography at 80 kVp with Sinogram-Affirmed Iterative Reconstruction Compared to 120 kVp with Filtered Back Projection: Assessment of Image Quality and Radiation Dose

Inyoung Song; Jeong Geun Yi; Jeong Hee Park; Sung Min Ko

Objective To evaluate the image quality and radiation dose of indirect computed tomographic venography (CTV) using 80 kVp with sinogram-affirmed iterative reconstruction (SAFIRE) and 120 kVp with filtered back projection (FBP). Materials and Methods This retrospective study was approved by our institution and informed consent was waived. Sixty-one consecutive patients (M: F = 27: 34, mean age 60 ± 16, mean BMI 23.6 ± 3.6 kg/m2) underwent pelvic and lower extremity CTVs [group A (n = 31, 120 kVp, reconstructed with FBP) vs. group B (n = 30, 80 kVp, reconstructed with SAFIRE)]. The vascular enhancement, image noise, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared. Subjective image analysis for image quality and noise was performed by two radiologists. Radiation dose was compared between the two groups. Results Compared with group A, higher mean vascular enhancement was observed in the group B (group A vs. B, 118.8 ± 15.7 HU vs. 178.6 ± 39.6 HU, p < 0.001), as well as image noise (12.0 ± 3.8 HU vs. 17.9 ± 6.1 HU, p < 0.001) and CNR (5.1 ± 1.9 vs. 7.6 ± 3.0, p < 0.001). The SNRs were not significantly different in both groups (11.2 ± 4.8 vs. 10.8 ± 3.7, p = 0.617). There was no significant difference in subjective image quality between the two groups (all p > 0.05). The subjective image noise was higher in the group B (p = 0.036 in reader 1, p = 0.005 in reader 2). The inter-observer reliability for assessing subjective image quality was good (ICC 0.746~0.784, p < 0.001). The mean CT dose index volume (CTDIvol) and mean dose length product (DLP) were significantly lower in group B than group A [CTDIvol, 6.4 ± 1.3 vs. 2.2 ± 2.2 mGy (p < 0.001); DLP, 499.1 ± 116.0 vs. 133.1 ± 45.7 mGy × cm (p < 0.001)]. Conclusions CTV using 80 kVp combined with SAFIRE provides lower radiation dose and improved CNR compared to CTV using 120 kVp with FBP.


Korean Journal of Radiology | 2018

Diagnostic Accuracy of Electrocardiogram-Gated Thoracic Computed Tomography Angiography without Heart Rate Control for Detection of Significant Coronary Artery Stenosis in Patients with Acute Ischemic Stroke: A Comparative Study

Inyoung Song; Ji Hun Kang; Mi Young Kim; Hweung Kon Hwang; Han Young Kim; Sung Min Ko

Objective To compare the diagnostic performance of electrocardiogram (ECG)-gated thoracic computed tomography angiography (TCTA) without heart rate (HR) control in ischemic stroke patients with coronary CTA (CCTA) in non-stroke patients for detection of significant coronary artery stenosis. Materials and Methods From September 2009 through August 2014, we retrospectively enrolled 138 consecutive patients diagnosed with acute ischemic stroke who had undergone ECG-gated TCTA and conventional coronary angiography (CCA). Over the same period, we selected 167 non-stroke patients with suspected or known coronary artery disease who had undergone CCTA and CCA. With CCA as the reference standard, the diagnostic performance of TCTA and CCTA for identification of significant coronary stenosis (diameter reduction ≥ 50%) was calculated. Results There was no significant difference in baseline characteristics between TCTA (n = 132) and CCTA (n = 164), except for the higher prevalence of atrial fibrillation in the stroke group. There was significant difference (p < 0.001) between TCTA and CCTA in average HR (68 ± 12 vs. 61 ± 10 beats per minute) and image quality score (1.3 ± 0.6 vs. 1.2 ± 0.6). Significant coronary stenosis was identified in 101 (77%) patients, 179 (45%) vessels, and 293 (15%) segments of stroke patients, and in 136 (83%) patients, 259 (53%) vessels, and 404 (16%) segments of non-stroke patients. Diagnostic performance on a per-vessel and per-patient basis was similar in both TCTA and CCTA groups. There was only significant difference in area under receiver-operating characteristic curve between TCTA and CCTA groups (0.79 vs. 0.87, p < 0.001) on per-segment basis. Conclusion Electrocardiogram-gated TCTA without HR control facilitates the identification of significant coronary stenosis in patients with ischemic stroke.


Acta Radiologica | 2018

Diagnostic performance of static single-scan stress perfusion cardiac computed tomography in detecting hemodynamically significant coronary artery stenosis: a comparison with combined invasive coronary angiography and cardiovascular magnetic resonance-myocardial perfusion imaging

Inyoung Song; Jeong Geun Yi; Jeong Hee Park; Mi Young Kim; Je Kyoun Shin; Sung Min Ko

Background Non-invasive anatomical and physiological evaluations of coronary artery disease (CAD) may be obtained with static single-scan stress perfusion cardiac computed tomography (SSPCT). Purpose To determine the diagnostic performance of static SSPCT for identifying hemodynamically significant CAD. Material and Methods This prospective study included 29 patients with suspected or known CAD who underwent static SSPCT, cardiovascular magnetic resonance myocardial perfusion imaging (CMR-MPI), and invasive coronary angiography (ICA). CT was performed as follows: (i) coronary calcium scan; (ii) static SSPCT for both coronary artery (coronary CT angiography [CCTA]) and myocardial perfusion (perfusion CT [PCT]) during adenosine infusion; (iii) late-phase scan. The diagnostic performance of CCTA alone, PCT alone, and SSPCT for the detection of a hemodynamically significant CAD (a perfusion defect in a vascular territory subtended by a coronary vessel with ≥ 50% stenosis) was compared with that of combined ICA/CMR-MPI representing the standard of reference. Results Twenty-three (79%) patients and 47 (54%) vascular territories manifested ischemia-causing coronary stenoses by combined ICA/CMR-MPI. The per-vessel sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) of the SSPCT were 92%, 88%, 90%, 90%, and 0.90, respectively, compared to those of the combined ICA/CMR-MPI. These values for the CCTA alone were 96%, 63%, 75%, 93%, and 0.79, respectively; and the values for the PCT alone were 94%, 83%, 86%, 92%, and 0.88, respectively. The AUC of SSPCT was significantly (P = 0.013) higher than that of the CCTA alone. Conclusion Static SSPCT may facilitate detection of hemodynamically significant CAD.


PLOS ONE | 2017

Differences in Aortic Valve and Left Ventricular Parameters Related to the Severity of Myocardial Fibrosis in Patients with Severe Aortic Valve Stenosis

Inyoung Song; Sung Min Ko; Jeong Geun Yi; Hyun Keun Chee; Jun Seok Kim

Objective This study investigated the morphological and functional characteristics of the aortic valve and the left ventricular (LV) systolic functional parameters and myocardial mass related to the severity of myocardial fibrosis (MF) in patients with severe aortic valve stenosis (AS). Materials and Methods We retrospectively enrolled 81 patients (48 men; mean age: 59±12 years) with severe AS who underwent transthoracic echocardiography (TTE), cardiac computed tomography (CCT), and cardiovascular magnetic resonance (CMR) within 1 month and subsequent aortic valve surgery. Degree of MF was determined on delayed contrast-enhanced CMR with visual sub-segmental analysis-based quantification and was classified into three groups (no, mild, and severe) for identifying the differences in LV function and characteristics of the aortic valve. One-way ANOVA, Chi-square test or Fisher’s exact test were used to compare variables of the three groups. Univariate multinomial logistic regression analysis was performed to determine the association between the severity of MF and variables on imaging modalities. Results Of 81 patients, 34 (42%) had MF (mild, n = 18; severe, n = 16). Aortic valve calcium volume score on CCT, aortic valve area, LV mass index, LV end-diastolic volume index on CMR, presence of mild aortic regurgitation (AR), transaortic mean pressure gradient, and peak velocity on TTE were significantly different among the three groups and were associated with severity of MF on a univariate multinomial logistic regression analysis. Aortic valve calcium grade was different (p = 0.008) among the three groups but not associated with severity of MF (p = 0.375). Conclusions A multi-imaging approach shows that severe AS with MF is significantly associated with more severe calcific AS, higher LV end-diastolic volume, higher LV mass, and higher prevalence of mild AR.


Korean Journal of Radiology | 2016

Morphological and Functional Evaluation of Quadricuspid Aortic Valves Using Cardiac Computed Tomography

Inyoung Song; Jung Ah Park; Bo Hwa Choi; Sung Min Ko; Je Kyoun Shin; Hyun Keun Chee; Jun Seok Kim

Objective The aim of this study was to identify the morphological and functional characteristics of quadricuspid aortic valves (QAV) on cardiac computed tomography (CCT). Materials and Methods We retrospectively enrolled 11 patients with QAV. All patients underwent CCT and transthoracic echocardiography (TTE), and 7 patients underwent cardiovascular magnetic resonance (CMR). The presence and classification of QAV assessed by CCT was compared with that of TTE and intraoperative findings. The regurgitant orifice area (ROA) measured by CCT was compared with severity of aortic regurgitation (AR) by TTE and the regurgitant fraction (RF) by CMR. Results All of the patients had AR; 9 had pure AR, 1 had combined aortic stenosis and regurgitation, and 1 had combined subaortic stenosis and regurgitation. Two patients had a subaortic fibrotic membrane and 1 of them showed a subaortic stenosis. One QAV was misdiagnosed as tricuspid aortic valve on TTE. In accordance with the Hurwitz and Roberts classification, consensus was reached on the QAV classification between the CCT and TTE findings in 7 of 10 patients. The patients were classified as type A (n = 1), type B (n = 3), type C (n = 1), type D (n = 4), and type F (n = 2) on CCT. A very high correlation existed between ROA by CCT and RF by CMR (r = 0.99) but a good correlation existed between ROA by CCT and regurgitant severity by TTE (r = 0.62). Conclusion Cardiac computed tomography provides comprehensive anatomical and functional information about the QAV.


BMC Medical Imaging | 2016

Color radiography in lung nodule detection and characterization: comparison with conventional gray scale radiography

Inyoung Song; Jeong Geun Yi; Jeong Hee Park; Kyung Soo Lee; Myung Jin Chung

BackgroundTo compare the capability of lung nodule detection and characterization between dual-energy radiography with color-representation (DCR) and conventional gray scale chest radiography (GSR).MethodsA total of 130 paired chest radiographs (DCR and GSR) obtained from 65 patients (14 with normal scans and 51 with pulmonary nodules) were evaluated. After analysis, 45 non-calcified and 21 calcified nodules were identified. DCR was obtained by adding color space within material-decomposed data (blue for high attenuation and red for low attenuation) and by compounding the manipulated data to one color image. Three radiologists marked suggested nodules on radiographic images and assessed the level of confidence of lesion presence and probability of nodule calcification by using a nine-point rating scale. The jackknife active free-response receiver operating characteristics (JAFROC) analysis was used to evaluate lesion detectability, and multi-reader multi-case receiver operating characteristics (MRMC ROC) analysis was used for the evaluation of the accuracy of nodule calcification prediction.ResultsFigures of merit (FOM) from JAFROC was 0.807 for DCR and 0.811 for GSR, respectively; nodule detectability was not significantly different between DCR and GSR (p = 0.93). Areas under curve (AUC) from MRMC ROC were 0.944 for DCR and 0.828 for GSR, respectively; performance of DCR in predicting lung nodule calcification was significantly higher than that of GSR (p = 0.04).ConclusionsDCR showed similar performance in terms of lung nodule detection compared with GSR. However, DCR does provide a significant benefit in predicting the presence of nodule calcification.

Collaboration


Dive into the Inyoung Song's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mi Young Kim

Seoul National University Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge