J. Du
Princeton University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by J. Du.
Acta Biomaterialia | 2013
J. Du; Xinrui Niu; Nima Rahbar; W. O. Soboyejo
The ceramic crown structures under occlusal contact are idealized as flat multilayered structures that are deformed under Hertzian contact loading. Those multilayers consist of a crown-like ceramic top layer, an adhesive layer and the dentin-like substrate. Bio-inspired design of the adhesive layer proposed functionally graded multilayers (FGM) that mimic the dentin-enamel junction in natural teeth. This paper examines the effects of FGM layer architecture on the contact-induced deformation of bio-inspired dental multilayers. Finite element modeling was used to explore the effects of thickness and architecture on the contact-induced stresses that are induced in bio-inspired dental multilayers. A layered nanocomposite structure was then fabricated by the sequential rolling of micro-scale nanocomposite materials with local moduli that increase from the side near the soft dentin-like polymer composite foundation to the side near the top ceramic layer. The loading rate dependence of the critical failure loads is shown to be well predicted by a slow crack growth model, which integrates the actual mechanical properties that are obtained from nanoindentation experiments.
Journal of Biomechanics | 2015
J. Du; Ji-Hyun Lee; Andrew T. Jang; Allen Gu; Mehran Hossaini-Zadeh; Richard Prevost; Donald A. Curtis; Sunita P. Ho
The effects of alveolar bone socket geometry and bone-implant contact on implant biomechanics, and resulting strain distributions in bone were investigated. Following extraction of lateral incisors on a cadaver mandible, implants were placed immediately and bone-implant contact area, stability implant biomechanics and bone strain were measured. In situ biomechanical testing coupled with micro X-ray microscopy (µ-XRM) illustrated less stiff bone-implant complexes (701-822 N/mm) compared with bone-periodontal ligament (PDL)-tooth complexes (791-913 N/mm). X-ray tomograms illustrated that the cause of reduced stiffness was due to limited bone-implant contact. Heterogeneous elemental composition of bone was identified by using energy dispersive X-ray spectroscopy (EDS). The novel aspect of this study was the application of a new experimental mechanics method, that is, digital volume correlation, which allowed mapping of strains in volumes of alveolar bone in contact with a loaded implant. The identified surface and subsurface strain concentrations were a manifestation of load transferred to bone through bone-implant contact based on bone-implant geometry, quality of bone, implant placement, and implant design. 3D strain mapping indicated that strain concentrations are not exclusive to the bone-implant contact regions, but also extend into bone not directly in contact with the implant. The implications of the observed strain concentrations are discussed in the context of mechanobiology. Although a plausible explanation of surgical complications for immediate implant treatment is provided, extrapolation of results is only warranted by future systematic studies on more cadaver specimens and/or in vivo models.
Journal of Applied Physics | 2015
O. K. Oyewole; Denis Y. W. Yu; J. Du; J. Asare; D. O. Oyewole; V. C. Anye; A. A. Fashina; M. G. Zebaze Kana; Winston O. Soboyejo
This paper presents the results of experimental and theoretical/computational micro-wrinkles and buckling on the surfaces of stretchable poly-dimethylsiloxane (PDMS) coated with nano-scale Gold (Au) layers. The wrinkles and buckles are formed by the unloading of pre-stretched PDMS/Au structure after the evaporation of nano-scale Au layers. They are then characterized using atomic force microscopy and scanning electron microscopy. The critical stresses required for wrinkling and buckling are analyzed using analytical models. The possible interfacial cracking that can occur along with film buckling is also studied using finite element simulations of the interfacial crack growth. The implications of the results are discussed for potential applications of micro-wrinkles and micro-buckles in stretchable electronic structures and biomedical devices.
Journal of Applied Physics | 2014
Denis Y. W. Yu; O. K. Oyewole; David Kwabi; Tiffany Tong; V. C. Anye; J. Asare; E. R. Rwenyagila; A. A. Fashina; Onobu Akogwu; J. Du; Winston O. Soboyejo
This paper presents the results of an experimental study of the adhesion between bi-material pairs that are relevant to organic light emitting devices, hybrid organic/inorganic light emitting devices, organic bulk heterojunction solar cells, and hybrid organic/inorganic solar cells on flexible substrates. Adhesion between the possible bi-material pairs is measured using force microscopy (AFM) techniques. These include: interfaces that are relevant to organic light emitting devices, hybrid organic/inorganic light emitting devices, bulk heterojunction solar cells, and hybrid combinations of titanium dioxide (TiO2) and poly(3-hexylthiophene). The results of AFM measurements are incorporated into the Derjaguin-Muller-Toporov model for the determination of adhesion energies. The implications of the results are then discussed for the design of robust organic and hybrid organic/inorganic electronic devices.
Journal of Applied Physics | 2014
J. Du; V. C. Anye; E. O. Vodah; Tiffany Tong; M. G. Zebaze Kana; W. O. Soboyejo
In this study, pressures of ∼5 to ∼8 MPa were applied to organic light emitting diodes containing either evaporated molybdenum trioxide (MoO3) or spin-coated poly(3,4-ethylene dioxythiophene) doped with poly(styrene sulphonate) (PEDOT:PSS) hole-injection layers (HILs). The threshold voltages for both devices were reduced by about half, after the application of pressure. Furthermore, in an effort to understand the effects of pressure treatment, finite element simulations were used to study the evolution of surface contact between the HIL and emissive layer (EML) under pressure. The blister area due to interfacial impurities was also calculated. This was shown to reduce by about half, when the applied pressures were between ∼5 and 8 MPa. The finite element simulations used Youngs modulus measurements of MoO3 that were measured using the nanoindentation technique. They also incorporated measurements of the adhesion energy between the HIL and EML (measured by force microscopy during atomic force microscopy)....
Journal of Applied Physics | 2015
O. K. Oyewole; Denis Y. W. Yu; J. Du; J. Asare; V. C. Anye; A. A. Fashina; M. G. Zebaze Kana; Winston O. Soboyejo
In this paper, a combined experimental, computational, and analytical approach is used to provide new insights into the lamination of organic solar cells and light emitting devices at macro- and micro-scales. First, the effects of applied lamination force (on contact between the laminated layers) are studied. The crack driving forces associated with the interfacial cracks (at the bi-material interfaces) are estimated along with the critical interfacial crack driving forces associated with the separation of thin films, after layer transfer. The conditions for successful lamination are predicted using a combination of experiments and computational models. Guidelines are developed for the lamination of low-cost organic electronic structures.
IEEE\/OSA Journal of Display Technology | 2013
J. Du; Tiffany Tong; Wali O. Akande; Androniki Tsakiridou; W. O. Soboyejo
This paper presents the results of finite element simulations of the lamination process for the fabrication of organic light-emitting diodes (OLEDs). The simulations utilize mechanical properties of the individual layers of the OLED structures that are obtained using nanoindentation techniques. The simulations show that applied pressure can cause contact evolution and sink-in around dust particles that are interposed between the organic materials layers, or the organic/inorganic layers. The implications of the results are discussed for the fabrication of robust OLEDs.
Acta Biomaterialia | 2012
Wanliang Shan; J. Du; E.P. Hampp; H. Li; G. Papandreou; Cynthia A. Maryanoff; W. O. Soboyejo
This paper presents a novel technique for the characterization of adhesion and cohesion in suspended micro-scale polymeric films. The technique involves push-out testing with probes that are fabricated using focused ion beam techniques. The underlying stresses associated with different probe tip sizes were computed using a finite element model. The critical force for failure of the film substrate interface is used to evaluate adhesion, while the critical force for penetration of the film determines cohesion. When testing a standard material, polycarbonate, a shear strength of approximately 70 MPa was calculated using the Mohr-Coulomb theory. This value was shown to be in agreement with the results in the literature. The technique was also applied to the measurement of adhesion and cohesion in a model drug-eluting stent (the Nevo™ Sirolimus Eluting Coronary Stent) containing suspended microscopic polymeric films in metallic Co-Cr alloy reservoirs. The cohesive strength of the formulation was found to be comparable with that of plastics such as those produced by reaction injection molding and high-density polyethylene.
AIP Advances | 2016
J. Asare; S. A. Adeniji; O. K. Oyewole; B. Agyei-Tuffour; J. Du; Emmanuel Kwesi Arthur; A. A. Fashina; M. G. Zebaze Kana; W. O. Soboyejo
This paper presents the results of an analytical and computational study of the contacts and interfacial fracture associated with the cold welding of Organic Light Emitting diodes (OLEDs). The effects of impurities (within the possible interfaces) are explored for contacts and interfacial fracture between layers that are relevant to model OLEDs. The models are used to study the effects of adhesion, pressure, thin film layer thickness and dust particle modulus (between the contacting surfaces) on contact profiles around impurities between cold-welded thin films. The lift-off stage of thin films (during cold welding) is then modeled as an interfacial fracture process. A combination of adhesion and interfacial fracture theories is used to provide new insights for the design of improved contact and interfacial separation during cold welding. The implications of the results are discussed for the design and fabrication of cold welded OLED structures.
Journal of The Mechanical Behavior of Biomedical Materials | 2015
J. Du; Xinrui Niu; W. O. Soboyejo
Ceramic crown structures under occlusal contact are often idealized as flat multilayered structures that are deformed under Hertzian contact loading. Previous models treated each layer as linear elastic materials and resulted in differences between the measured and predicted critical loads. This paper examines the combined effects of creep (in the adhesive and substrate layers) and creep-assisted slow crack growth (in the ceramic layer) on the contact-induced deformation of bio-inspired, functionally graded multilayer (FGM) structures and the conventional tri-layers. The time-dependent moduli of each of the layers were determined from constant load creep tests. The resulting modulus-time characteristics were modeled using Prony series. These were then incorporated into a finite element model for the computation of stress distributions in the sub-surface regions of the top ceramic layer, in which sub-surface radial cracks, are observed as the clinical failure mode. The time-dependent stresses are incorporated into a slow crack growth (SCG) model that is used to predict the critical loads of the dental multilayers under Hertzian contact loading. The predicted loading rate dependence of the critical loads is shown to be consistent with experimental results. The implications of the results are then discussed for the design of robust dental multilayers.