Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where J.M. Cordero García is active.

Publication


Featured researches published by J.M. Cordero García.


Revista Espanola De Medicina Nuclear | 2012

Análisis de costo-efectividad en el diagnóstico de fiebre de origen desconocido y el papel de la 18F-FDG PET-TC: propuesta de algoritmo diagnóstico

E.M. Becerra Nakayo; A.M. García Vicente; A. Soriano Castrejón; J.A. Mendoza Narváez; M.P. Talavera Rubio; V.M. Poblete García; J.M. Cordero García

AIM To analyze the costs of Fever of Unknown Origin (FUO) prior to the PET-CT study. To determine the effectiveness of PET-CT in the diagnosis of FUO. A proposal of diagnostic algorithm. MATERIAL AND METHODS A retrospective study was performed that included 20 patients who had been studied between January 2007 and January 2011, with a mean age of 57.75 years and FUO diagnosis. All underwent a PET-CT study with (18)F-FDG. Individual and mean costs of FUO in these patients were assessed, including hospitalization days and complementary tests prior to the PET-CT study. The effectiveness of the PET-CT study in the diagnosis of FUO was analyzed. Costs of the FUO process were determined, including those of the PET-CT study, and if it had been done earlier in the diagnostic process. RESULTS Mean hospital stay per patient until the PET-CT study was 28 days. The cost per hospitalization day was 342 €. Average cost per patient in complementary tests was 1395 €. Total cost of the FUO process until the PET-CT study was around 11167 € per patient. The PET-CT study showed a 78% sensitivity, 83% specificity, 92% PPV and 62% NPV. If PET-CT had been performed earlier in the FUO process, assuming the same effectiveness, 5471 € per patient would have been saved. CONCLUSION The PET-CT study could be cost-effective in the FUO process if used at an early stage, helping to establish an early diagnosis, reducing hospitalization days due to diagnostic purposes and the repetition of unnecessary tests.


Revista Espanola De Medicina Nuclear | 2012

18F-FDG semi-quantitative parameters and biological prognostic factors in locally advanced breast cancer

A.M. García Vicente; A. Soriano Castrejón; F. Relea Calatayud; V. Muñoz Madero; M.J. Molina Garrido; A. León Martín; J.M. Cordero García; J.P. Pilkington Woll; I. Chacón López-Muñiz; A. Palomar Muñoz

AIM To analyse the correlation between (18)F-FDG uptake assessed by PET/CT in locally advanced breast tumours and histopathological and immunohistochemical prognostic factors. MATERIAL AND METHODS Thirty-six women with breast cancer were prospectively evaluated. PET/CT was requested in the initial staging previous to adjuvant chemotherapy (multicentric study). All the patients underwent an (18)F-FDG PET/CT with a dual-time-point acquisition. Both examinations were evaluated qualitatively and semiquantitatively with calculation of SUVmax values in PET-1 (SUV-1) and in PET-2 (SUV-2) and the percentage variation of the standard uptake values (retention index) between PET-1 and PET-2. Clinical and metabolic stages were assessed according to TNM classification. The biological prognostic parameters, such as the steroid receptor status, p53 and c-erbB-2 expression, proliferation rate (Ki-67), and grading were determined from tissue of the primary tumour. Metabolic and biological parameters were correlated. RESULTS A positive relationship was found between semiquantitative metabolic parameters and biological parameters. SUV-1 and SUV-2 values did not show significant statistical correlation (p<.05) except for the clinical tumour size. About the biological parameters, retention index showed the best results with positive and significant relation (p<.05) with estrogen and progesterone receptor status and Ki-67. Isolated SUV values did not show significant relation to these parameters. CONCLUSION Retention index showed the best relation with biological parameters compared to isolated SUVmax values. These data suggest that SUV change over time is a prognostic marker.


Revista Espanola De Medicina Nuclear | 2009

PET-TAC con contraste intravenoso en la valoración de pacientes con linfoma. Aproximación hacia las indicaciones diagnósticas

M.P. Talavera Rubio; A.M. García Vicente; E. Domínguez Ferreras; C. Calle Primo; V.M. Poblete García; B. Hernández Ruiz; M.E. Bellón Guardia; A. Palomar Muñoz; I. Cepedello Boiso; P. Pilkington Woll; B. González García; J.M. Cordero García; C. Molino Trinidad; A. Soriano Castrejón

AIM To define the utility of intravenous contrast administration in the PET-CT (PET-CTc) in patients with lymphoma in order to determine its possible indications. MATERIAL AND METHODS 78 patients with lymphoma were prospectively evaluated. All underwent simultaneous PET-CTc scans in a hybrid system for staging (8), evaluation of response to treatment (29), suspicion of recurrence (9) and complete remission control (48). The PET scan was acquired by a conventional method and the diagnostic CT scan was performed according to radiological protocol. Both examinations were evaluated blinded and independently, analyzing 28 anatomical locations in order to determine the degree of agreement. Final diagnosis was established by the clinician based on the histological study, results of other diagnostic techniques or clinical follow-up. RESULTS The final result of both techniques were concordant in 87/94 studies (92.5%). A total of 158 (36 FP) pathological locations were detected with PET-CT and 189 (71 FP) with CTc, with 72 locations being discordant between both techniques. Global sensitivity, specificity, PPV and NPV were 93%, 98%, 77% and 99%; and 94%, 97%, 62% and 99%, respectively. CONCLUSIONS Administration of intravenous contrast does not seem to provide any advantage in the determination of nodal and extranodal disease in lymphoma patients. The low prevalence of disease probably accounts for the limited PPV of both techniques. An increase of our sample size, with a greater homogeneity of the groups, should offer more reliable results.


Revista Espanola De Medicina Nuclear | 2013

Implantación de un sistema de gestión de calidad según norma UNE-UN-ISO 9001:2008 en un servicio de medicina nuclear

V.M. Poblete García; M.P. Talavera Rubio; A. Palomar Muñoz; J.P. Pilkington Woll; J.M. Cordero García; A.M. García Vicente; M.E. Bellón Guardia; B. González García; T. Cañuelo Merino; A. Núñez García; V. Peiró Valgañón; A. Soriano Castrejón

OBJECTIVE To describe the process of implementing a quality management system according to UNE-EN-ISO 9001:2008 standard in a Nuclear Medicine Department. MATERIAL AND METHOD In February 2008, the committee on internal quality of the Department was established, naming a responsible physician. The general operating plan was drawn up, following the requirements established by the ISO 9001:2008 standard. It defined the scope of the standard, defining, preparing and transcribing the various activities of our Department. Four training sessions were carried out. RESULTS A total of nine general and two specific procedures were documented in which all the activities performed in our Department were included. Personnel records of each worker were created, including their profiles and training plan. A record of the equipment and service providers was created, as well as issues with the latter. Satisfaction surveys were obtained from external (patients) and internal customers (faculty applicants). Targets for improvement and activity markers were established. Two audits were performed to complete the process, one internal and one external. The Department was accredited in April 2010. CONCLUSION The quality accreditation process is a tool that requires reflection on how we do things and how they can be improved. It makes it possible to measure what we do, to analyze and introduce improvement measures, and therefore, to achieve a higher level of quality in the service we provide our customers. The involvement of the Department workers with a commitment to team performance was essential.OBJECTIVE To describe the process of implementing a quality management system according to UNE-EN-ISO 9001:2008 standard in a Nuclear Medicine Department. MATERIAL AND METHOD In February 2008, the committee on internal quality of the Department was established, naming a responsible physician. The general operating plan was drawn up, following the requirements established by the ISO 9001:2008 standard. It defined the scope of the standard, defining, preparing and transcribing the various activities of our Department. Four training sessions were carried out. RESULTS A total of nine general and two specific procedures were documented in which all the activities performed in our Department were included. Personnel records of each worker were created, including their profiles and training plan. A record of the equipment and service providers was created, as well as issues with the latter. Satisfaction surveys were obtained from external (patients) and internal customers (faculty applicants). Targets for improvement and activity markers were established. Two audits were performed to complete the process, one internal and one external. The Department was accredited in April 2010. CONCLUSION The quality accreditation process is a tool that requires reflection on how we do things and how they can be improved. It makes it possible to measure what we do, to analyze and introduce improvement measures, and therefore, to achieve a higher level of quality in the service we provide our customers. The involvement of the Department workers with a commitment to team performance was essential.


Revista Espanola De Medicina Nuclear | 2010

Impacto diagnóstico y terapéutico de la 18F-FDG-PET/TAC en pacientes con sospecha de recidiva de cáncer de mama

A. Palomar Muñoz; A.M. García Vicente; M.P. Talavera Rubio; J.P. Pilkington Woll; V.M. Poblete García; M.E. Bellón Guardia; A. León Martín; J.M. Cordero García; A. Soriano Castrejón

Breast cancer is a tumor with high prevalence in our environment. Thus, it is essential to make an early diagnosis in both the primary disease and its recurrence, given the high mortality of the cases with the advanced disease. Our study has aimed to evaluate the impact of (18)F-FDG-PET/CT in patients with suspected breast cancer recurrence and their therapeutic management. This study analyzed the PET/CT of 70 patients with a background of breast cancer and suspicion of recurrence, either because of elevation of tumor markers (n=28), doubtful findings on other imaging techniques (n=56) and/or suspicious symptoms (n=1). All the patients underwent a standard FDG-PET study acquired in combination with low-dose CT. The studies were considered pathological in 34 of the 70 patients, with 29 true positive, 32 true negative, 5 false positive and 4 false negative results. The final diagnosis was established either by histopathologic confirmation (n=17), other imaging techniques (n=26) and/or clinical radiological follow-up (n=27, mean 12.7 months). The sensitivity, specificity, positive predictive value and negative predictive values obtained were 87.8%, 86.4%, 85.2% and 88.8%, respectively. Therapeutic management was modified in 41% of the patients. In conclusion, PET/CT is a technique with high diagnostic yield in patients with suspected breast cancer recurrence.


Revista Espanola De Medicina Nuclear | 2012

PET-TAC con 18F-FDG en el seguimiento de pacientes con linfoma, detección de recidivas asintomáticas

A.M. García Vicente; M.E. Bellón Guardia; A. Soriano Castrejón; C. Calle Primo; J.M. Cordero García; A. Palomar Muñoz; J.P. Pilkington Woll; M.P. Talavera Rubio; B. Hernández Ruiz

AIM To assess the diagnostic accuracy of (18)F-FDG-PET/CT in detecting asymptomatic recurrences in patients with lymphoma. To define uptake patterns of recurrence indicative of recurrence. MATERIAL AND METHODS Those patients with lymphoma who fulfilled the following inclusion criteria of clinical complete remission and negative PET/CT study were included retrospectively and longitudinally. Conventional surveillance of these patients was performed only by (18)F-FDG PET/CT following a standardized procedure. Pathologic locations (supra- and infradiaphragmatic) and their character (single or multiple) were analyzed in order to determine reliable metabolic patterns of recurrence. The final diagnosis was established by histopathological analysis or clinical follow-up greater than 8 months. RESULTS A total of 199 explorations belonging to 106 patients with lymphoma were included. Of these patients, 59 had Hodgkins lymphoma and 47 non-Hodgkins lymphoma. There was suspicion of relapse from the metabolic point of view in 27 of the PET/CT scans. Of these, 14 (10 patients) were false positive (FP), and 13 (8 patients) true positive. The remaining studies were true negative, no false negatives being detected. The pattern most frequently related to recurrence was infradiaphragmatic lymph node involvement while most of the FP had isolated supradiaphragmatic involvement. Sensitivity, specificity, PPV, NPV and diagnostic accuracy of PET/CT parameters for the study were 100%, 92%, 48%, 100% and 93%, respectively. CONCLUSION (18)F-FDG-PET/CT is a sensitive technique in the detection of asymptomatic recurrences in patients with lymphoma during their follow-up. Multiple character and infradiaphragmatic locations were the patterns that best correlated to the diagnosis of recurrence.AIM To assess the diagnostic accuracy of (18)F-FDG-PET/CT in detecting asymptomatic recurrences in patients with lymphoma. To define uptake patterns of recurrence indicative of recurrence. MATERIAL AND METHODS Those patients with lymphoma who fulfilled the following inclusion criteria of clinical complete remission and negative PET/CT study were included retrospectively and longitudinally. Conventional surveillance of these patients was performed only by (18)F-FDG PET/CT following a standardized procedure. Pathologic locations (supra- and infradiaphragmatic) and their character (single or multiple) were analyzed in order to determine reliable metabolic patterns of recurrence. The final diagnosis was established by histopathological analysis or clinical follow-up greater than 8 months. RESULTS A total of 199 explorations belonging to 106 patients with lymphoma were included. Of these patients, 59 had Hodgkins lymphoma and 47 non-Hodgkins lymphoma. There was suspicion of relapse from the metabolic point of view in 27 of the PET/CT scans. Of these, 14 (10 patients) were false positive (FP), and 13 (8 patients) true positive. The remaining studies were true negative, no false negatives being detected. The pattern most frequently related to recurrence was infradiaphragmatic lymph node involvement while most of the FP had isolated supradiaphragmatic involvement. Sensitivity, specificity, PPV, NPV and diagnostic accuracy of PET/CT parameters for the study were 100%, 92%, 48%, 100% and 93%, respectively. CONCLUSION (18)F-FDG-PET/CT is a sensitive technique in the detection of asymptomatic recurrences in patients with lymphoma during their follow-up. Multiple character and infradiaphragmatic locations were the patterns that best correlated to the diagnosis of recurrence.


Revista Espanola De Medicina Nuclear | 2010

Micrometástasis en el ganglio centinela y macrometástasis ganglionares axilares en el cáncer de mama

J.M. Cordero García; M. Delgado Portela; A.M. García Vicente; J.P. Pilkington Woll; M.A. Palomar Muñoz; V.M. Poblete García; M.E. Bellón Guardia; R. Pardo García; L. Rabadán Ruiz; A. Soriano Castrejón

AIM The study of the sentinel node has made it possible to obtain more comprehensive knowledge about the extent of axillary involvement in breast cancer. It has also decreased the surgical morbidity associated to the surgical examination of the axilla. The systematic use of immunohistochemical staining and molecular biology techniques improves the ability to detect the presence of micrometastasis or isolated tumor cells in a significant number of cases when this is the only sign of the lymph node extension of the disease. The possibility of avoiding complete axillary lymphadenectomy in those patients who are only affected by micrometastasis is proposed because of the low incidence of further involvement of the remaining lymph nodes. MATERIAL AND METHOD 159 patients diagnosed of stage T1 or T2 breast cancer, in which the sentinel node had been identified by scintigraphy and intraoperative localization, were included in the study. Complete axillary lymphadenectomy was performed when micro- or macrometastases were found in the sentinel node, in order to determine the degree of axillary involvement. RESULTS A total of 40 patients (25%) showed infiltration of the sentinel node. This infiltration was only by micrometastasis in 17 of them (10.7%). Of these 17 patients, only 2 (11.8%) showed macro-metastasis in the lymphadenectomy. In the remaining subjects, the final staging reached after the sentinel node study was not modified. CONCLUSION It is possible to speculate that, in the future, axillary dissection can be avoided in those patients diagnosed of micrometastasis in the sentinel node, pending the conclusions of the on-going multicenter studies.


Revista Espanola De Medicina Nuclear | 2013

Falsos positivos en PET-TC con 18F-Colina en pacientes con cáncer de próstata

A.M. García Vicente; A. Núñez García; A. Soriano Castrejón; G.A. Jiménez Londoño; J.M. Cordero García; A. Palomar Muñoz

The (18)F-choline PET-CT (FCH) has better performance in the assessment of patients with prostate cancer than (18)F-FDG. However, similarly, it is also not a tumor specific radiotracer. We present four (18)F-FCH PET-CT scans in which false positive findings were correctly assessed after evaluation with CT, clinical parameters and/or histological analysis.


Revista Espanola De Medicina Nuclear | 2010

[Diagnostic and therapeutic impact of 18F-FDG-PET/CT in patients with suspected breast cancer recurrence].

A. Palomar Muñoz; A.M. García Vicente; M.P. Talavera Rubio; J.P. Pilkington Woll; V.M. Poblete García; M.E. Bellón Guardia; A. León Martín; J.M. Cordero García; A. Soriano Castrejón

Abstract Breast cancer is a tumor with high prevalence in our environment. Thus, it is essential to make an early diagnosis in both the primary disease and its recurrence, given the high mortality of the cases with the advanced disease. Our study has aimed to evaluate the impact of 18 F-FDG-PET/CT in patients with suspected breast cancer recurrence and their therapeutic management. This study analyzed the PET/CT of 70 patients with a background of breast cancer and suspicion of recurrence, either because of elevation of tumor markers (n=28), doubtful findings on other imaging techniques (n=56) and/or suspicious symptoms (n=1). All the patients underwent a standard FDG-PET study acquired in combination with low-dose CT. The studies were considered pathological in 34 of the 70 patients, with 29 true positive, 32 true negative, 5 false positive and 4 false negative results. The final diagnosis was established either by histopathologic confirmation (n=17), other imaging techniques (n=26) and/or clinical radiological follow-up (n=27, mean 12.7 months). The sensitivity, specificity, positive predictive value and negative predictive values obtained were 87.8%, 86.4%, 85.2% and 88.8%, respectively. Therapeutic management was modified in 41% of the patients. In conclusion, PET/CT is a technique with high diagnostic yield in patients with suspected breast cancer recurrence.


Revista Espanola De Medicina Nuclear | 2009

18F-FDG PET/CT and respiratory synchronization: effect in the detection and classification of pulmonary lesions

A.M. García Vicente; A. Soriano Castrejón; P. Talavera Rubio; V.M. Poblete García; A. Palomar Muñoz; I. Cepedello Boiso; B. González García; J.M. Cordero García; M.E. Bellón Guardia; J.P. Pilkington Woll

Abstract Respiratory movement reduces sensitivity in the detection of pulmonary lesions. This disadvantage can be reduced with synchronized acquisition of PET with respiratory movement (4D). Our objective was to assess the effect of 4D PET/CT in the metabolic activity of 18F FDG and the final classification of pulmonary lesions. Material and Methods 12 patients with 18 pulmonary lesions whose sizes were within 0.8-4 cm were assessed. Maximum SUV was obtained in the image acquired under standard conditions (3D) and that obtained in the respiratory period with higher metabolic activity in 4D images. The percentage of difference between both values was calculated. Furthermore, changes in classification of pulmonary nodes (benign or malignant) obtained from the assessment of 4D and 3D PET images were evaluated. Results 17/18 pulmonary lesions showed an increase in the SUV max value in the 4D in regards to 3D image. Five lesions showed SUV max values > 2.5 in 4D image and Conclusion 18F-FDG 4D PET/CT shows values of metabolic activity that are more in accordance with the correct classification of malignant lesions, thus reducing the false negatives although the false positives increase.

Collaboration


Dive into the J.M. Cordero García's collaboration.

Top Co-Authors

Avatar

A. Soriano Castrejón

Rafael Advanced Defense Systems

View shared research outputs
Top Co-Authors

Avatar

A.M. García Vicente

Rafael Advanced Defense Systems

View shared research outputs
Top Co-Authors

Avatar

V. Peiró Valgañón

University of Texas MD Anderson Cancer Center

View shared research outputs
Researchain Logo
Decentralizing Knowledge