J. Matthew Dubach
Northeastern University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by J. Matthew Dubach.
Analytical Chemistry | 2010
Kelvin Billingsley; Mary K. Balaconis; J. Matthew Dubach; Ning Zhang; Ed Lim; Kevin P. Francis; Heather A. Clark
We have designed fluorescent nanosensors based on ion-selective optodes capable of detecting small molecules. By localizing the sensor components in a hydrophobic core, these nanosensors are able to monitor dynamic changes in concentration of the model analyte, glucose. The nanosensors demonstrated this response in vitro and also when injected subcutaneously into mice. The response of the nanosensors tracked changes in blood glucose levels in vivo that were comparable to measurements taken using a glucometer. The development of these nanosensors offers an alternative, minimally invasive tool for monitoring glucose levels in such fields as diabetes research. Furthermore, the extension of the ion-selective optode sensor platform to small molecule detection will allow for enhanced monitoring of physiological processes.
Proceedings of the National Academy of Sciences of the United States of America | 2009
J. Matthew Dubach; Saumya Das; Anthony Rosenzweig; Heather A. Clark
Regulation of sodium flux across the cell membrane plays a vital role in the generation of action potentials and regulation of membrane excitability in cells such as cardiomyocytes and neurons. Alteration of sodium channel function has been implicated in diseases such as epilepsy, long QT syndrome, and heart failure. However, single cell imaging of sodium dynamics has been limited due to the narrow selection of fluorescent sodium indicators available to researchers. Here we report, the detection of spatially defined sodium activity during action potentials. Fluorescent nanosensors that measure sodium in real-time, are reversible and are completely selective over other cations such as potassium that were used to image sodium. The use of the nanosensors in vitro was validated by determining drug-induced activation in heterologous cells transfected with the voltage-gated sodium channel NaV1.7. Spatial information of sodium concentrations during action potentials will provide insight at the cellular level on the role of sodium and how slight changes in sodium channel function can affect the entirety of an action potential.
Biomacromolecules | 2008
Salmaan H. Baxamusa; Laura Montero; J. Matthew Dubach; Heather A. Clark; Salvador Borrós; Karen K. Gleason
We report photoinitiated chemical vapor deposition (piCVD), a gentle synthetic method for the preparation of ultrathin films (approximately 100 nm) of the hydrogel poly(hydroxyethyl methacrylate) (pHEMA). piCVD occurs near room temperature and requires only mild vacuum conditions. The deposited films swell rapidly and reversibly in buffer solution, and the swelling properties can be controlled via the deposition conditions. Analysis of the swelling data indicates that the mesh size of the hydrogel creates a selectively permeable coating. The mesh is large enough to allow small molecule analytes to permeate the film but small enough to prevent the transport of large biomolecules such as proteins. X-ray photoelectron spectroscopy (XPS) shows that the films decrease nonspecific adhesion of the protein albumin by nearly 8-fold over bare silicon. A dry process, piCVD is suitable for coating particles with diameters as small as 5 microm. The absence of solvents and plasmas in piCVD allows films to be directly synthesized on optode sensors without degradation of sensitivity or response time.
Proceedings of the National Academy of Sciences of the United States of America | 2011
Gozde Ozaydin-Ince; J. Matthew Dubach; Karen K. Gleason; Heather A. Clark
There have been a variety of nanoparticles created for in vivo uses ranging from gene and drug delivery to tumor imaging and physiological monitoring. The use of nanoparticles to measure physiological conditions while being fluorescently addressed through the skin provides an ideal method toward minimally invasive health monitoring. Here we create unique particles that have all the necessary physical characteristics to serve as in vivo reporters, but with minimized diffusion from the point of injection. These particles, called microworms, have a cylindrical shape coated with a biocompatible porous membrane that possesses a large surface-area-to-volume ratio while maintaining a large hydrodynamic radius. We use these microworms to create fluorescent sodium sensors for use as in vivo sodium concentration detectors after subcutaneous injection. However, the microworm concept has the potential to extend to the immobilization of other types of polymers for continuous physiological detection or delivery of molecules.
Nature Communications | 2017
Michael F. Cuccarese; J. Matthew Dubach; Christina Pfirschke; Camilla Engblom; Christopher Garris; Miles A. Miller; Mikael J. Pittet; Ralph Weissleder
Involvement of the immune system in tumour progression is at the forefront of cancer research. Analysis of the tumour immune microenvironment has yielded a wealth of information on tumour biology, and alterations in some immune subtypes, such as tumour-associated macrophages (TAM), can be strong prognostic indicators. Here, we use optical tissue clearing and a TAM-targeting injectable fluorescent nanoparticle (NP) to examine three-dimensional TAM composition, tumour-to-tumour heterogeneity, response to colony-stimulating factor 1 receptor (CSF-1R) blockade and nanoparticle-based drug delivery in murine pulmonary carcinoma. The method allows for rapid tumour volume assessment and spatial information on TAM infiltration at the cellular level in entire lungs. This method reveals that TAM density was heterogeneous across tumours in the same animal, overall TAM density is different among separate pulmonary tumour models, nanotherapeutic drug delivery correlated with TAM heterogeneity, and successful response to CSF-1R blockade is characterized by enhanced TAM penetration throughout and within tumours.
Nature Chemical Biology | 2017
J. Matthew Dubach; Eunha Kim; Katherine S. Yang; Michael F. Cuccarese; Randy J. Giedt; Labros G. Meimetis; Claudio Vinegoni; Ralph Weissleder
Quantitation of drug target engagement in single cells has proven to be difficult, often leaving unanswered questions in the drug development process. We found that intracellular target engagement of unlabeled new therapeutics can be quantitated using polarized microscopy combined with competitive binding of matched fluorescent companion imaging probes. We quantitated the dynamics of target engagement of covalent BTK inhibitors, as well as reversible PARP inhibitors, in populations of single cells using a single companion imaging probe for each target. We then determined average in vivo tumor concentrations and found marked population heterogeneity following systemic delivery, revealing single cells with low target occupancy at high average target engagement in vivo.
Journal of diabetes science and technology | 2011
Mary K. Balaconis; Kelvin Billingsley; J. Matthew Dubach; Kevin J. Cash; Heather A. Clark
Background: The advent of fluorescent nanosensors has enabled intracellular monitoring of several physiological analytes, which was previously not possible with molecular dyes or other invasive techniques. We have extended the capability of these sensors to include the detection of small molecules with the development of glucose-sensitive nano-optodes. Herein, we discuss the design and development of glucose-sensitive nano-optodes, which have been proven functional both in vitro and in vivo. Methods: Throughout the design process, each of the sensor formulations was evaluated based on their response to changes in glucose levels. The percent change in signal, sensor reversibility, and the overall fluorescence intensity were the specific parameters used to assess each formulation. Results: A hydrophobic boronic acid was selected that yielded a fully reversible fluorescence response to glucose in accordance with the sensor mechanism. The change in fluorescence signal in response to glucose was approximately 11%. The use of different additives or chromophores did not improve the response; however, modifications to the plasticized polymeric membrane extended sensor lifetime. Conclusions: Sensors were developed that yielded a dynamic response to glucose and through further modification of the components, sensor lifetime was improved. By following specific design criteria for the macrosensors, the sensors were miniaturized into nano-optodes that track changes in glucose levels in vivo.
Scientific Reports | 2013
Timothy T. Ruckh; Ankeeta A. Mehta; J. Matthew Dubach; Heather A. Clark
This work introduces a polymer-free optode nanosensor for ratiometric sodium imaging. Transmembrane ion dynamics are often captured by electrophysiology and calcium imaging, but sodium dyes suffer from short excitation wavelengths and poor selectivity. Optodes, optical sensors composed of a polymer matrix with embedded sensing chemistry, have been translated into nanosensors that selectively image ion concentrations. Polymer-free nanosensors were fabricated by emulsification and were stable by diameter and sensitivity for at least one week. Ratiometric fluorescent measurements demonstrated that the nanosensors are selective for sodium over potassium by ~1.4 orders of magnitude, have a dynamic range centered at 20 mM, and are fully reversible. The ratiometric signal changes by 70% between 10 and 100 mM sodium, showing that they are sensitive to changes in sodium concentration. These nanosensors will provide a new tool for sensitive and quantitative ion imaging.
Macromolecular Rapid Communications | 2009
Daniel I. Harjes; J. Matthew Dubach; Anthony Rosenzweig; Saumya Das; Heather A. Clark
Optodes have been used for detection of ionic concentrations and fluxes for several years. However, their uses in biomedical applications have not yet been fully explored. This study investigates optodes as a potential sensor platform for monitoring cellular ion flux with attendant implications in the field of drug screening and toxicology. A prototype system was developed to quantitatively measure extracellular potassium flux from a monolayer of cardiomyocytes. Optodes were created and immobilized on a glass coverslip for fluorescent imaging. The system detected potassium (K(+) ) ion flux during the repolarization phase of the cardiac action potential and further detected a decrease in the magnitude of the flux in the presence of a known K(+) channel inhibitor by optically monitoring local K(+) ion concentrations during field stimulation of the cardiomyocyte monolayer.
Drug Discovery Today | 2015
Claudio Vinegoni; J. Matthew Dubach; Miles A. Miller; Ralph Mazitschek; Ralph Weissleder
Measuring key pharmacokinetic and pharmacodynamic parameters in vivo at the single cell level is likely to enhance drug discovery and development. In this review, we summarize recent advances in this field and highlight current and future capabilities.