Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where J. Paul Finn is active.

Publication


Featured researches published by J. Paul Finn.


Circulation | 1999

Relationship of MRI Delayed Contrast Enhancement to Irreversible Injury, Infarct Age, and Contractile Function

Raymond J. Kim; David S. Fieno; Todd B. Parrish; Kathleen E. Harris; Enn-Ling Chen; Orlando P. Simonetti; Jeffrey M. Bundy; J. Paul Finn; Francis J. Klocke; Robert M. Judd

BACKGROUND Contrast MRI enhancement patterns in several pathophysiologies resulting from ischemic myocardial injury are controversial or have not been investigated. We compared contrast enhancement in acute infarction (AI), after severe but reversible ischemic injury (RII), and in chronic infarction. METHODS AND RESULTS In dogs, a large coronary artery was occluded to study AI and/or chronic infarction (n = 18), and a second coronary artery was chronically instrumented with a reversible hydraulic occluder and Doppler flowmeter to study RII (n = 8). At 3 days after surgery, cine MRI revealed reduced wall thickening in AI (5+/-6% versus 33+/-6% in normal, P<0.001). In RII, wall thickening before, during, and after inflation of the occluder for 15 minutes was 35+/-5%, 1+/-8%, and 21+/-10% and Doppler flow was 19.8+/-5.3, 0.2+/-0.5, and 56.3+/-17.7 (peak hyperemia) cm/s, respectively, confirming occlusion, transient ischemia, and reperfusion. Gd-DTPA-enhanced MR images acquired 30 minutes after contrast revealed hyperenhancement of AI (294+/-96% of normal, P<0.001) but not of RII (98+/-6% of normal, P = NS). Eight weeks later, the chronically infarcted region again hyperenhanced (253+/-54% of normal, n = 8, P<0.001). High-resolution (0.5 x 0.5 x 0.5 mm) ex vivo MRI demonstrated that the spatial extent of hyperenhancement was the same as the spatial extent of myocyte necrosis with and without reperfusion at 1 day (R = 0.99, P<0.001) and 3 days (R = 0.99, P<0.001) and collagenous scar at 8 weeks (R = 0.97, P<0.001). CONCLUSIONS In the pathophysiologies investigated, contrast MRI distinguishes between reversible and irreversible ischemic injury independent of wall motion and infarct age.


Circulation | 2010

ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance A Report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents

W. Gregory Hundley; David A. Bluemke; J. Paul Finn; Scott D. Flamm; Mark A. Fogel; Matthias G. Friedrich; Vincent B. Ho; Michael Jerosch-Herold; Christopher M. Kramer; Warren J. Manning; Manesh R. Patel; Gerald M. Pohost; Arthur E. Stillman; Richard D. White; Pamela K. Woodard

Robert A. Harrington, MD, FACC, FAHA, Chair Jeffrey L. Anderson, MD, FACC, FAHA[††][1] Eric R. Bates, MD, FACC Charles R. Bridges, MD, MPH, FACC, FAHA Mark J. Eisenberg, MD, MPH, FACC, FAHA Victor A. Ferrari, MD, FACC, FAHA Cindy L. Grines, MD, FACC[††][1] Mark A. Hlatky, MD, FACC,


American Journal of Roentgenology | 2006

Cardiovascular Function in Multi-Ethnic Study of Atherosclerosis: Normal Values by Age, Sex, and Ethnicity

Shunsuke Natori; Shenghan Lai; J. Paul Finn; Antoinette S. Gomes; W. Gregory Hundley; Michael Jerosch-Herold; Gregory D. N. Pearson; Shantanu Sinha; Andrew E. Arai; Joao A.C. Lima; David A. Bluemke

OBJECTIVE MRI provides accurate and high-resolution measurements of cardiac anatomy and function. The purpose of this study was to describe the imaging protocol and normal values of left ventricular (LV) function and mass in the Multi-Ethnic Study of Atherosclerosis (MESA). SUBJECTS AND METHODS Eight hundred participants (400 men, 400 women) in four age strata (45-54, 55-64, 65-74, 75-84 years) were chosen at random. Participants with the following known cardiovascular risk factors were excluded: current smoker, systolic blood pressure > 140 mm Hg, diastolic blood pressure > 90 mm Hg, fasting glucose > 110 mg/dL, total cholesterol > 240 mg/dL, and high-density lipoprotein (HDL) cholesterol < 40 mg/dL. Cardiac MR images were analyzed using MASS software (version 4.2). Mean values, SDs, and correlation coefficients in relationship to patient age were calculated. RESULTS There were significant differences in LV volumes and mass between men and women. LV volumes were inversely associated with age (p < 0.05) for both sexes except for the LV end-systolic volume index. For men, LV mass was inversely associated with age (slope = -0.72 g/year, p = 0.0021), but LV mass index was not associated with age (slope = -0.179 g/m2/year, p = 0.075). For women, LV mass (slope = -0.15 g/year, p = 0.30) and LV mass index (slope = 0.0044 g/m2/year, p = 0.95) were not associated with age. LV mass was the largest in the African-American group (men, 181.6 +/- 35.8 [SD] g; women, 128.8 +/- 28.1 g) and was smallest in the Asian-American group (men, 129.1 +/- 20.0 g; women, 89.4 +/- 13.3 g). CONCLUSION The normal LV differs in volume and mass between sexes and among certain ethnic groups. When indexed by body surface area, LV mass was independent of age for both sexes. Studies that assess cardiovascular risk factors in relationship to cardiac function and structure need to account for these normal variations in the population.


Journal of the American College of Cardiology | 2010

Expert Consensus DocumentACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance: A Report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents

W. Gregory Hundley; David A. Bluemke; J. Paul Finn; Scott D. Flamm; Mark A. Fogel; Matthias G. Friedrich; Vincent B. Ho; Michael Jerosch-Herold; Christopher M. Kramer; Warren J. Manning; Manesh R. Patel; Gerald M. Pohost; Arthur E. Stillman; Richard D. White; Pamela K. Woodard

American College of Cardiology Foundation Representative; †North merican Society for Cardiovascular Imaging Representative; ‡Society or Cardiovascular Magnetic Resonance Representative; §American cademy of Pediatrics; American College of Radiology Representaive; ¶ACCF Task Force Liaison; #American Heart Association epresentative. **The findings and conclusions in this expert consensus ocument reflect ACCF policy and do not necessarily represent the iews of the Uniformed Services University of the Health Sciences, the .S. Department of Defense, or the U.S. Government, by whom Dr.


Magnetic Resonance in Medicine | 2001

3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries

Vibhas S. Deshpande; Steven M. Shea; Gerhard Laub; Orlando P. Simonetti; J. Paul Finn; Debiao Li

The purpose of this work was to develop an ECG‐triggered, segmented 3D true‐FISP (fast imaging with steady‐state precession) technique to improve the signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) of breath‐hold coronary artery imaging. The major task was to optimize an appropriate magnetization preparation scheme to permit saturation of the epicardial fat signal. An α/2 preparation pulse was used to speed up the approach to steady‐state following a frequency‐selective fat‐saturation pulse in each heartbeat. The application of dummy cycles was found to reduce the oscillation of the magnetization during data acquisition. The fat saturation and magnetization preparation scheme was validated with simulations and phantom studies. Volunteer studies demonstrated substantially increased SNR (55%) and CNR (178%) for coronary arteries compared to FLASH (fast low‐angle shot) with the same imaging time. In conclusion, true‐FISP is a promising technique for coronary artery imaging. Magn Reson Med 46:494–502, 2001.


Bioinformatics | 2011

The Cardiac Atlas Project—an imaging database for computational modeling and statistical atlases of the heart

Carissa G. Fonseca; Michael Backhaus; David A. Bluemke; Randall Britten; Jae Do Chung; Brett R. Cowan; Ivo D. Dinov; J. Paul Finn; Peter Hunter; Alan H. Kadish; Daniel C. Lee; Joao A.C. Lima; Pau Medrano-Gracia; Kalyanam Shivkumar; Avan Suinesiaputra; Wenchao Tao; Alistair A. Young

Motivation: Integrative mathematical and statistical models of cardiac anatomy and physiology can play a vital role in understanding cardiac disease phenotype and planning therapeutic strategies. However, the accuracy and predictive power of such models is dependent upon the breadth and depth of noninvasive imaging datasets. The Cardiac Atlas Project (CAP) has established a large-scale database of cardiac imaging examinations and associated clinical data in order to develop a shareable, web-accessible, structural and functional atlas of the normal and pathological heart for clinical, research and educational purposes. A goal of CAP is to facilitate collaborative statistical analysis of regional heart shape and wall motion and characterize cardiac function among and within population groups. Results: Three main open-source software components were developed: (i) a database with web-interface; (ii) a modeling client for 3D + time visualization and parametric description of shape and motion; and (iii) open data formats for semantic characterization of models and annotations. The database was implemented using a three-tier architecture utilizing MySQL, JBoss and Dcm4chee, in compliance with the DICOM standard to provide compatibility with existing clinical networks and devices. Parts of Dcm4chee were extended to access image specific attributes as search parameters. To date, approximately 3000 de-identified cardiac imaging examinations are available in the database. All software components developed by the CAP are open source and are freely available under the Mozilla Public License Version 1.1 (http://www.mozilla.org/MPL/MPL-1.1.txt). Availability: http://www.cardiacatlas.org Contact: [email protected] Supplementary information: Supplementary data are available at Bioinformatics online.


Neurobiology of Aging | 2010

Lifespan trajectory of myelin integrity and maximum motor speed.

George Bartzokis; Po H. Lu; Kathleen Tingus; Mario F. Mendez; Aurore Richard; Douglas G. Peters; Bolanle Oluwadara; Katherine A. Barrall; J. Paul Finn; Pablo Villablanca; Paul M. Thompson; Jim Mintz

OBJECTIVE Myelination of the human brain results in roughly quadratic trajectories of myelin content and integrity, reaching a maximum in mid-life and then declining in older age. This trajectory is most evident in vulnerable later myelinating association regions such as frontal lobes and may be the biological substrate for similar trajectories of cognitive processing speed. Speed of movement, such as maximal finger tapping speed (FTS), requires high-frequency action potential (AP) bursts and is associated with myelin integrity. We tested the hypothesis that the age-related trajectory of FTS is related to brain myelin integrity. METHODS A sensitive in vivo MRI biomarker of myelin integrity (calculated transverse relaxation rates (R(2))) of frontal lobe white matter (FLwm) was measured in a sample of very healthy males (N=72) between 23 and 80 years of age. To assess specificity, R(2) of a contrasting early-myelinating region (splenium of the corpus callosum) was also measured. RESULTS FLwm R(2) and FTS measures were significantly correlated (r=.45, p<.0001) with no association noted in the early-myelinating region (splenium). Both FLwm R(2) and FTS had significantly quadratic lifespan trajectories that were virtually indistinguishable and both reached a peak at 39 years of age and declined with an accelerating trajectory thereafter. CONCLUSIONS The results suggest that in this very healthy male sample, maximum motor speed requiring high-frequency AP burst may depend on brain myelin integrity. To the extent that the FLwm changes assessed by R(2) contribute to an age-related reduction in AP burst frequency, it is possible that other brain functions dependent on AP bursts may also be affected. Non-invasive measures of myelin integrity together with testing of basic measures of processing speed may aid in developing and targeting anti-aging treatments to mitigate age-related functional declines.


Journal of Magnetic Resonance Imaging | 2002

TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model

David S. Fieno; Wyatt C. Jaffe; Orlando P. Simonetti; Robert M. Judd; J. Paul Finn

To test the accuracy of a high performance true fast imaging with steady‐state precession (TrueFISP) pulse sequence for the assessment of left ventricular (LV) mass in a large animal model on 1.5‐T scanners.


Journal of Cardiovascular Electrophysiology | 2009

Rationale and design for the Defibrillators to Reduce Risk by Magnetic Resonance Imaging Evaluation (DETERMINE) trial.

Alan H. Kadish; David Bello; J. Paul Finn; Robert O. Bonow; Andi Schaechter; Haris Subacius; Christine M. Albert; James P. Daubert; Carissa G. Fonseca; Jeffrey J. Goldberger

Background: Cardiac magnetic resonance imaging (CMR) can accurately determine infarct size. Prior studies using indirect methods and CMR to assess infarct size have shown that patients with larger myocardial infarctions have worse prognoses. Implantable cardioverter defibrillators (ICD) have been shown to improve survival among patients with severe left ventricular (LV) dysfunction. However, the majority of cardiac arrests occur in patients with higher ejection fractions.


Radiographics | 2009

Coronary Artery Fistulas: CT Findings

Navid A. Zenooz; Reza Habibi; Leena Mammen; J. Paul Finn; Robert C. Gilkeson

Coronary artery fistulas are anomalous terminations of the coronary arteries. Most often, these fistulas are incidentally identified in the adult and pediatric populations. Many patients are asymptomatic; however, an awareness of these fistulas is important because they have been associated with various clinical features, including chest pain or heart failure in young patients. Correct diagnosis of coronary artery fistulas is important, and early surgical correction is indicated because of the high prevalence of late symptoms and complications. Traditionally, conventional angiography has been used for the diagnosis of coronary anomalies. With more frequent use of 64-row multi-detector computed tomography (CT) in chest and cardiac imaging, the number of incidentally found coronary artery fistulas has been increasing. CT angiography and conventional angiography can have additive value in diagnosis of this cardiac anomaly. In every CT study of the heart, special attention should be paid to the courses and terminations of the coronary arteries to detect these potentially fatal anomalies.

Collaboration


Dive into the J. Paul Finn's collaboration.

Top Co-Authors

Avatar

Gerhard Laub

Northwestern University

View shared research outputs
Top Co-Authors

Avatar

Kambiz Nael

Icahn School of Medicine at Mount Sinai

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Peng Hu

University of California

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Debiao Li

Cedars-Sinai Medical Center

View shared research outputs
Top Co-Authors

Avatar

Roya Saleh

University of California

View shared research outputs
Top Co-Authors

Avatar

James Carr

Northwestern University

View shared research outputs
Top Co-Authors

Avatar

Anderanik Tomasian

University of Southern California

View shared research outputs
Researchain Logo
Decentralizing Knowledge