J. Pinto da Cunha
University of Coimbra
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by J. Pinto da Cunha.
Physical Review D | 2009
V. N. Lebedenko; H.M. Araújo; E. J. Barnes; A. Bewick; R. Cashmore; V. Chepel; A. Currie; D. Davidge; J. Dawson; T. Durkin; B. Edwards; C. Ghag; M. Horn; A.S. Howard; A. J. Hughes; W.G. Jones; M. Joshi; G. Kalmus; A.G. Kovalenko; A. Lindote; I. Liubarsky; M.I. Lopes; R. Lüscher; P. Majewski; A. St. J. Murphy; F. Neves; J. Pinto da Cunha; R. Preece; J. J. Quenby; P.R. Scovell
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12 kg two-phase xenon time-projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionization produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected from WIMPs and the electron-recoil background signals down to {approx}10 keV nuclear-recoil energy. An analysis of 847 kg{center_dot}days of data acquired between February 27, 2008, and May 20, 2008, has excluded a WIMP-nucleon elastic scattering spin-independent cross section above 8.1x10{sup -8} pb at 60 GeVc{sup -2} with a 90% confidence limit. It has also demonstrated that the two-phase xenon technique is capable of better discrimination between electron and nuclear recoils at low-energy than previously achieved by other xenon-based experiments.
Physics Letters B | 2012
D. Yu. Akimov; H.M. Araújo; E. J. Barnes; V. A. Belov; A. Bewick; A. Burenkov; V. Chepel; A. Currie; L. DeViveiros; B. Edwards; C. Ghag; A. Hollingsworth; M. Horn; W.G. Jones; G. Kalmus; A. S. Kobyakin; A. G. Kovalenko; V. N. Lebedenko; A. Lindote; M.I. Lopes; R. Lüscher; P. Majewski; A. St. J. Murphy; F. Neves; S. M. Paling; J. Pinto da Cunha; R. Preece; J. J. Quenby; L. Reichhart; P.R. Scovell
Abstract We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1344 kg⋅days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7–29 keV, which is compatible with background expectations. This allows the exclusion of the scalar cross-section above 4.8 × 10 − 8 pb near 50 GeV / c 2 WIMP mass with 90% confidence. Combined with data from the first run, this result improves to 3.9 × 10 − 8 pb . The corresponding WIMP-neutron spin-dependent cross-section limit is 8.0 × 10 − 3 pb . The ZEPLIN programme reaches thus its conclusion at Boulby, having deployed and exploited successfully three liquid xenon experiments of increasing reach.
Astroparticle Physics | 2007
D. Yu. Akimov; G. J. Alner; H.M. Araújo; A. Bewick; C. Bungau; A. A. Burenkov; M.J. Carson; H. Chagani; V. Chepel; D. Cline; D. Davidge; E. Daw; J. Dawson; T. Durkin; B. Edwards; T. Gamble; C. Chag; R. Hollingworth; A.S. Howard; W.G. Jones; M. Joshi; K. Mavrokoridis; E.V. Korolkova; A. G. Kovalenko; V.A. Kudryavtsev; I. S. Kuznetsov; T.B. Lawson; V. N. Lebedenko; J.D. Lewin; P. K. Lightfoot
We present details of the technical design, manufacture and testing of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
Journal of Non-crystalline Solids | 1996
H. V. Alberto; J. Pinto da Cunha; Bjorn O. Mysen; J. M. Gil; N. Ayres de Campos
A new method is proposed to evaluate the hyperfine parameter distribution in Mossbauer spectra of silicate glasses. The method assumes a distribution of isomer shift and quadrupole splitting with a two-dimensional Gaussian shape. Application of the method to Mossbauer spectra of CaOSiO2FeO glasses containing different redox ratios, Fe3+/Fe2+, is discussed. It is shown that the two-dimensional Gaussian distribution method leads to a very good description of the data with a relatively small number of free parameters.
Physics Letters B | 1995
R. Adler; K. Jon-And; A. Liolios; J. Derre; Eef van Beveren; Dimitri V. Nanopoulos; L. Sakeliou; R. Rickenbach; P. Fassnacht; P. Carlson; Theo Geralis; A. Schopper; R. Gamet; Jorge L. Lopez; E. Machado; C.W.E. van Eijk; Philippe Schune; D. Francis; P. Weber; A. Apostolakis; T. Ruf; J. Pinto da Cunha; D. Garreta; J. Carvalho; M. Carroll; Marc Dejardin; M. Mikuz; M. Fidecaro; I. Mandić; Ch. Yèche
Abstract We use fits to recent published CPLEAR data on neutral kaon decays to π + π − and πeν to constrain the CPT-violation parameters appearing in a formulation of the neutral kaon system as an open quantum-mechanical system. The obtained upper limits of the CPT-violation parameters are approaching the range suggested by certain ideas concerning quantum gravity.
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | 2000
J. Pinto da Cunha; F. Neves; M.I. Lopes
Abstract An event reconstruction algorithm to analyze Cherenkov rings in a Ring Imaging Cherenkov (RICH) detector is considered and the results of a Monte Carlo simulation are discussed. It is demonstrated that aerogel radiators can be used in RICH detectors despite the Rayleigh scattering of light if filtered by a pattern recognition program. The velocity of the particle radiating Cherenkov light, β, is determined by a fit to the photon hit pattern, assuming prior momentum measurement by a tracking system. The charge of the particle, z, is obtained from the collected light. The results show that, for the geometries considered, velocity resolutions σβ/β≃1×10−3 and charge resolutions σZ/Z≃10% can be achieved for 5 GeV /c protons and a 2 cm thick aerogel radiator.
Physical Review Letters | 2009
V. N. Lebedenko; H.M. Araújo; E. J. Barnes; A. Bewick; R. Cashmore; V. Chepel; A. Currie; D. Davidge; J. Dawson; T. Durkin; B. Edwards; C. Ghag; M. Horn; A.S. Howard; A. J. Hughes; W.G. Jones; M. Joshi; G. Kalmus; A.G. Kovalenko; A. Lindote; I. Liubarsky; M.I. Lopes; R. Lüscher; K. Lyons; P. Majewski; A. St. J. Murphy; F. Neves; J. Pinto da Cunha; R. Preece; J. J. Quenby
We present new experimental constraints on the WIMP-nucleon spin-dependent elastic cross sections using data from the first science run of ZEPLIN-III, a two-phase xenon experiment searching for galactic dark matter weakly interacting massive particles based at the Boulby mine. Analysis of approximately 450 kg x days fiducial exposure allow us to place a 90%-confidence upper limit on the pure WIMP-neutron cross section of sigma(n)=1.9x10(-2) pb at 55 GeV/c(2) WIMP mass. Recent calculations of the nuclear spin structure based on the Bonn charge-dependent nucleon-nucleon potential were used for the odd-neutron isotopes 129Xe and 131Xe. These indicate that the sensitivity of xenon targets to the spin-dependent WIMP-proton interaction could be much lower than implied by previous calculations, whereas the WIMP-neutron sensitivity is impaired only by a factor of approximately 2.
Physics Letters B | 2011
M. Horn; V. A. Belov; D. Yu. Akimov; H.M. Araújo; E. J. Barnes; A. Burenkov; V. Chepel; A. Currie; B. Edwards; C. Ghag; A. Hollingsworth; G. Kalmus; A. S. Kobyakin; A. G. Kovalenko; V. N. Lebedenko; A. Lindote; M.I. Lopes; R. Lüscher; P. Majewski; A. St. J. Murphy; F. Neves; S. M. Paling; J. Pinto da Cunha; R. Preece; J. J. Quenby; L. Reichhart; P.R. Scovell; Catarina Silva; V. Solovov; N.J.T. Smith
Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keVnr (nuclear recoil energy) are deduced from data acquired using broadband Am–Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below ∼40 keVnr is found, together with a rising ionisation yield; both are in agreement with the latest independent measurements. The analysis method is applied to the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am–Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.
ieee nuclear science symposium | 2011
V. Solovov; V. A. Belov; D. Y. Akimov; H.M. Araújo; E. J. Barnes; A. Burenkov; V. Chepel; A. Currie; L. DeViveiros; Blair Edwards; C. Ghag; A. Hollingsworth; M. Horn; G. Kalmus; A. S. Kobyakin; A. G. Kovalenko; V. N. Lebedenko; A. Lindote; M.I. Lopes; R. Lüscher; P. Majewski; Asj Murphy; F. Neves; S. M. Paling; J. Pinto da Cunha; R. Preece; J. J. Quenby; L. Reichhart; P.R. Scovell; Catarina Silva
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated γ -ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV γ-rays. For the inner part of the detector (R <; 100 mm) , spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
Journal of High Energy Physics | 2011
E. Santos; B. Edwards; V. Chepel; H.M. Araújo; D. Y. Akimov; E. J. Barnes; V. A. Belov; A. Burenkov; A. Currie; L. DeViveiros; C. Ghag; A. Hollingsworth; M. Horn; G. Kalmus; A. S. Kobyakin; A. G. Kovalenko; V. N. Lebedenko; A. Lindote; M.I. Lopes; R. Lüscher; P. Majewski; A. St. J. Murphy; F. Neves; S. M. Paling; J. Pinto da Cunha; R. Preece; J. J. Quenby; L. Reichhart; P.R. Scovell; Catarina Silva
A bstractWe present an experimental study of single electron emission in ZEPLIN-III, a two-phase xenon experiment built to search for dark matter WIMPs, and discuss appli-cations enabled by the excellent signal-to-noise ratio achieved in detecting this signature. Firstly, we demonstrate a practical method for precise measurement of the free electron lifetime in liquid xenon during normal operation of these detectors. Then, using a realistic detector response model and backgrounds, we assess the feasibility of deploying such an instrument for measuring coherent neutrino-nucleus elastic scattering using the ionisation channel in the few-electron regime. We conclude that it should be possible to measure this elusive neutrino signature above an ionisation threshold of ~3 electrons both at a stopped pion source and at a nuclear reactor. Detectable signal rates are larger in the reactor case, but the triggered measurement and harder recoil energy spectrum afforded by the accelerator source enable lower overall background and fiducialisation of the active volume.