Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where J. Ramos-Castro is active.

Publication


Featured researches published by J. Ramos-Castro.


Classical and Quantum Gravity | 2009

LISA Pathfinder: the experiment and the route to LISA

M. Armano; M. Benedetti; J. Bogenstahl; D. Bortoluzzi; P. Bosetti; N. Brandt; A. Cavalleri; G. Ciani; I. Cristofolini; A. M. Cruise; Karsten Danzmann; I. Diepholz; G. Dixon; R. Dolesi; J. Fauste; L. Ferraioli; D. Fertin; Walter Fichter; M. Freschi; Antonio Garcia; C. Garcia; A. Grynagier; F. Guzman; E. Fitzsimons; Gerhard Heinzel; M. Hewitson; D. Hollington; J. Hough; M. Hueller; D. Hoyland

LISA Pathfinder (LPF) is a science and technology demonstrator planned by the European Space Agency in view of the LISA mission. As a scientific payload, the LISA Technology Package on board LPF will be the most precise geodesics explorer flown as of today, both in terms of displacement and acceleration sensitivity. The challenges embodied by LPF make it a unique mission, paving the way towards the space-borne detection of gravitational waves with LISA. This paper summarizes the basics of LPF, and the progress made in preparing its effective implementation in flight. We hereby give an overview of the experiment philosophy and assumptions to carry on the measurement. We report on the mission plan and hardware design advances and on the progress on detailing measurements and operations. Some light will be shed on the related data processing algorithms. In particular, we show how to single out the acceleration noise from the spacecraft motion perturbations, how to account for dynamical deformation parameters distorting the measurement reference and how to decouple the actuation noise via parabolic free flight.


Classical and Quantum Gravity | 2011

LISA Pathfinder: mission and status

F. Antonucci; M. Armano; H. Audley; G. Auger; M. Benedetti; P. Binetruy; C. Boatella; J. Bogenstahl; D. Bortoluzzi; Paolo Bosetti; M. Caleno; A. Cavalleri; M. Cesa; M. Chmeissani; G. Ciani; A. Conchillo; Giuseppe Congedo; I. Cristofolini; M. Cruise; Karsten Danzmann; F. De Marchi; M. Diaz-Aguilo; I. Diepholz; G. Dixon; R. Dolesi; N. Dunbar; J. Fauste; L. Ferraioli; D. Fertin; Walter Fichter

LISA Pathfinder, the second of the European Space Agencys Small Missions for Advanced Research in Technology (SMART), is a dedicated technology demonstrator for the joint ESA/NASA Laser Interferometer Space Antenna (LISA) mission. The technologies required for LISA are many and extremely challenging. This coupled with the fact that some flight hardware cannot be fully tested on ground due to Earth-induced noise led to the implementation of the LISA Pathfinder mission to test the critical LISA technologies in a flight environment. LISA Pathfinder essentially mimics one arm of the LISA constellation by shrinking the 5 million kilometre armlength down to a few tens of centimetres, giving up the sensitivity to gravitational waves, but keeping the measurement technology: the distance between the two test masses is measured using a laser interferometric technique similar to one aspect of the LISA interferometry system. The scientific objective of the LISA Pathfinder mission consists then of the first in-flight test of low frequency gravitational wave detection metrology. LISA Pathfinder is due to be launched in 2013 on-board a dedicated small launch vehicle (VEGA). After a series of apogee raising manoeuvres using an expendable propulsion module, LISA Pathfinder will enter a transfer orbit towards the first Sun?Earth Lagrange point (L1). After separation from the propulsion module, the LPF spacecraft will be stabilized using the micro-Newton thrusters, entering a 500?000 km by 800?000 km Lissajous orbit around L1. Science results will be available approximately 2 months after launch.


international conference of the ieee engineering in medicine and biology society | 2012

Heart rate variability analysis using a seismocardiogram signal

J. Ramos-Castro; Jordi Moreno; H. Miranda-Vidal; M A García-González; Mireya Fernández-Chimeno; G. Rodas; Ll. Capdevila

Seismocardiography is a simple and non invasive method of recording cardiac activity from the movements of the body caused by heart pumping. In this preliminary study we use a smartphone to record this acceleration and estimate the heart rate. We compare the heart rate variability parameters from the seismocardiogram and ECG reference signal. The results show a great similarity and are strongly influenced by the instability in the sampling frequency of the device. The differences between RR series are lower than 10 ms.


Classical and Quantum Gravity | 2012

The LISA Pathfinder Mission

F. Antonucci; M. Armano; H. Audley; G. Auger; M. Benedetti; P. Binetruy; J. Bogenstahl; D. Bortoluzzi; Paolo Bosetti; N. Brandt; M. Caleno; Priscilla Canizares; A. Cavalleri; M. Cesa; M. Chmeissani; A. Conchillo; Giuseppe Congedo; I. Cristofolini; M. Cruise; Karsten Danzmann; F. De Marchi; M. Diaz-Aguilo; I. Diepholz; G. Dixon; R. Dolesi; N. Dunbar; J. Fauste; L. Ferraioli; V. Ferrone; Walter Fichter

In this paper, we describe the current status of the LISA Pathfinder mission, a precursor mission aimed at demonstrating key technologies for future space-based gravitational wave detectors, like LISA. Since much of the flight hardware has already been constructed and tested, we will show that performance measurements and analysis of these flight components lead to an expected performance of the LISA Pathfinder which is a significant improvement over the mission requirements, and which actually reaches the LISA requirements over the entire LISA Pathfinder measurement band.


IEEE Transactions on Biomedical Engineering | 2009

Errors in the Estimation of Approximate Entropy and Other Recurrence-Plot-Derived Indices Due to the Finite Resolution of RR Time Series

M A García-González; Mireya Fernández-Chimeno; J. Ramos-Castro

An analysis of the errors due to the finite resolution of RR time series in the estimation of the approximate entropy (ApEn) is described. The quantification errors in the discrete RR time series produce considerable errors in the ApEn estimation (bias and variance) when the signal variability or the sampling frequency is low. Similar errors can be found in indices related to the quantification of recurrence plots. An easy way to calculate a figure of merit [the signal to resolution of the neighborhood ratio (SRN)] is proposed in order to predict when the bias in the indices could be high. When SRN is close to an integer value n, the bias is higher than when near n-1/2 or n+1/2. Moreover, if SRN is close to an integer value, the lower this value, the greater the bias is.


Classical and Quantum Gravity | 2009

Data analysis for the LISA Technology Package

M. Hewitson; M. Armano; M. Benedetti; J. Bogenstahl; D. Bortoluzzi; Paolo Bosetti; N. Brandt; A. Cavalleri; G. Ciani; I. Cristofolini; M. Cruise; Karsten Danzmann; I. Diepholz; R. Dolesi; J. Fauste; L. Ferraioli; D. Fertin; Walter Fichter; Antonio Garcia; C. Garcia; A. Grynagier; F. Guzman; E. Fitzsimons; Gerhard Heinzel; D. Hollington; J. Hough; M. Hueller; D. Hoyland; O. Jennrich; B. Johlander

The LISA Technology Package (LTP) on board the LISA Pathfinder mission aims to demonstrate some key concepts for LISA which cannot be tested on ground. The mission consists of a series of preplanned experimental runs. The data analysis for each experiment must be designed in advance of the mission. During the mission, the analysis must be carried out promptly so that the results can be fed forward into subsequent experiments. As such a robust and flexible data analysis environment needs to be put in place. Since this software is used during mission operations and effects the mission timeline, it must be very robust and tested to a high degree. This paper presents the requirements, design and implementation of the data analysis environment (LTPDA) that will be used for analysing the data from LTP. The use of the analysis software to perform mock data challenges (MDC) is also discussed, and some highlights from the first MDC are presented.


Physiological Measurement | 2004

Bias and uncertainty in heart rate variability spectral indices due to the finite ECG sampling frequency

M A García-González; Mireya Fernández-Chimeno; J. Ramos-Castro

Spectral analysis of the heart rate variability is becoming a usual tool as a marker of the autonomic nervous system. The final output of the spectral analysis is a set of indices that are always estimators due to technical limitations. In this work, the bias and the uncertainty in the VLF, LF, HF and LF/HF indices due to the finite sampling frequency of the ECG are analysed. The results indicate that for low sampling frequency (125 Hz), the bias and uncertainty in the HF and LF/HF indices can blur the results of the analysis, especially if the RR time series has low variability. The HF index is overestimated and, accordingly, the LF/HF index is underestimated. Then, results from RR time series with low sampling frequency must be used with care. The uncertainty of the spectral indices is proportional to the inverse of the sampling frequency and the bias is proportional to the inverse of the square sampling frequency.


International Journal of Sports Medicine | 2015

Facial Video-Based Photoplethysmography to Detect HRV at Rest.

Jordi Moreno; J. Ramos-Castro; J. Movellan; Eva Parrado; Gil Rodas; Lluís Capdevila

Our aim is to demonstrate the usefulness of photoplethysmography (PPG) for analyzing heart rate variability (HRV) using a standard 5-min test at rest with paced breathing, comparing the results with real RR intervals and testing supine and sitting positions. Simultaneous recordings of R-R intervals were conducted with a Polar system and a non-contact PPG, based on facial video recording on 20 individuals. Data analysis and editing were performed with individually designated software for each instrument. Agreement on HRV parameters was assessed with concordance correlations, effect size from ANOVA and Bland and Altman plots. For supine position, differences between video and Polar systems showed a small effect size in most HRV parameters. For sitting position, these differences showed a moderate effect size in most HRV parameters. A new procedure, based on the pixels that contained more heart beat information, is proposed for improving the signal-to-noise ratio in the PPG video signal. Results were acceptable in both positions but better in the supine position. Our approach could be relevant for applications that require monitoring of stress or cardio-respiratory health, such as effort/recuperation states in sports.


Classical and Quantum Gravity | 2006

On-ground tests of the LISAPathFinder thermal diagnostics system

Alberto Lobo; M. Nofrarias; J. Ramos-Castro; J. Sanjuan

Thermal conditions in the LTP, the LISA Technology Package, are required to be very stable, and in such environments precision temperature measurements are also required for various diagnostics objectives. A sensitive temperature gauging system for the LTP is being developed at IEEC, which includes a set of thermistors and associated electronics. In this paper, we discuss the derived requirements applying to the temperature sensing system, and address the problem of how to create in the laboratory a thermally quiet environment, suitable for performing meaningful on-ground tests of the system. The concept is a two-layer spherical body, with a central aluminium core for sensor implantation surrounded by a layer of polyurethane. We construct the insulator transfer function, which relates the temperature at the core to the laboratory ambient temperature, and evaluate the losses caused by heat leakage through connecting wires. The results of the analysis indicate that, in spite of the very demanding stability conditions, a sphere of outer diameter of the order 1 m is sufficient. We provide experimental evidence confirming the model predictions.


Physiological Measurement | 2003

A new index for the analysis of heart rate variability dynamics: characterization and application

M A García-González; J. Ramos-Castro; Mireya Fernández-Chimeno

A new index for the analysis of the heart rate variability (HRV) dynamics is presented. The proposed index (acceleration change index (ACI)) characterizes the sign of the differences of a time series. A theoretical study shows an expression that relates ACI and the autocorrelation function of the time series. This formula is tested and validated with different simulated time series (uncorrelated noise, sinusoidal and fractional Brownian motion). Next, ACI is applied to RR time series from healthy subjects showing that ACI decreases with periodic controlled breathing, increases during exercise, and it has a lower value at night than during the day. In a preliminary study, ACI has been shown to be lower in healthy subjects than in patients who had suffered a myocardial infarction one month previously. ACI can be employed as a fast and robust new marker of the HRV dynamics.

Collaboration


Dive into the J. Ramos-Castro's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

M. Armano

European Space Agency

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Alberto Lobo

Institut de Ciències de l'Espai

View shared research outputs
Top Co-Authors

Avatar

M A García-González

Polytechnic University of Catalonia

View shared research outputs
Top Co-Authors

Avatar

C. Grimani

Istituto Nazionale di Fisica Nucleare

View shared research outputs
Top Co-Authors

Avatar

Mireya Fernández-Chimeno

Polytechnic University of Catalonia

View shared research outputs
Researchain Logo
Decentralizing Knowledge