Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by J. Venkateswara Rao.
Journal of Chemistry | 2011
K. Srinivasu; J. Venkateswara Rao; N. Appala Raju; K. Mukkanti
A validated RP HPLC method for the estimation of atazanavir in capsule dosage form on YMC ODS 150 × 4.6 mm, 5 μ column using mobile phase composition of ammonium dihydrogen phosphate buffer (pH 2.5) with acetonitrile (55:45 v/v). Flow rate was maintained at 1.5 mL/min with 288 nm UV detection. The retention time obtained for atazanavir was at 4.7 min. The detector response was linear in the concentration range of 30 - 600 μg/mL. This method has been validated and shown to be specific, sensitive, precise, linear, accurate, rugged, robust and fast. Hence, this method can be applied for routine quality control of atazanavir in capsule dosage forms as well as in bulk drug.
Journal of Chemistry | 2008
N. Appala Raju; J. Venkateswara Rao; K. Vanitha Prakash; K. Mukkanti; K. Srinivasu
A simple, precise, rapid and accurate reverse phase HPLC method developed for the estimation of levetiracetam in tablet dosage form. A Sun Fire C18, 250 x 4.6 mm, 5 μm partical size, with mobile phase consisting of acetonitrile and 0.03 M potassium dihydrogen phosphate (pH adjusted to 3.0 with orthophosphoric acid) in the ratio of 15:85 v/v was used. The flow rate was 1 mL /min and the effluents were monitored at 210 nm. The retention time was 5.53 min. The detector response was linear in the concentration of 20-240 μg/mL. The respective linear regression equation being Y= 22119.684 x 6829.3428. The limit of detection and limit of quantification was 0.16 and 0.5 μg/mL respectively. The percentage assay of levetiracetam was 99.87%. The method was validated by determining its accuracy, precision and system suitability. The results of the study showed that the proposed RP-HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of levetiracetam in bulk drug and in its pharmaceutical dosage form.
Journal of Chemistry | 2007
K. Vanitha Prakash; J. Venkateswara Rao; N. Appala Raju
A reverse phase HPLC method is described for the determination of Nelfinavir Mesylate in tablet dosage form. Chromatography was carried on an ODS column using a mixture of acetonitrile and phosphate buffer pH 6 (90:10 v/v) as the mobile phase at a flow rate of 1.2 mL/min with detection at 230 nm. The retention time of the drug was 6.68 min. The detector response was linear in the concentration of 1-20 mcg/mL. The limit of detection and limit of quantification was 1.0 and 10.0 mcg/ mL respectively. The percentage assay of Nelfinavir Mesylate was 99.77 %. The method was validated by determining its sensitivity, accuracy and precision. The proposed method is simple, fast, accurate and precise and hence can be applied for routine quality control of Nelfinavir Mesylate in bulk and tablet dosage form.
Journal of Chemistry | 2008
N. Appala Raju; J. Venkateswara Rao; K. Vanitha Prakash; K. Mukkanti
Two simple, accurate, rapid and sensitive methods (A and B) have been developed for the estimation of abacavir sulphate in its pharmaceutical dosage form. The method A and B are based on the formation of chloroform extractable complex of abacavir sulphate with bromophenol blue (method A) and bromocresol green (method B), which shows absorbance maxima at 460 nm and 469 nm respectively. The absorbance-concentration plot is linear over the range of 1-10 mcg/mL for method A and B respectively. Results of analysis for all the methods were validated statistically and by recovery studies. The proposed methods are economical and sensitive for the estimation of abacavir sulphate in bulk drug and in its tablet dosage form.
Archive | 2008
K. Srinivasu; J. Venkateswara Rao; N. Appala Raju; K. Mukkanti
Archive | 2008
N. Appala Raju; J. Venkateswara Rao; K. Vanitha Prakash
Oriental journal of chemistry | 2007
K. Vanitha Prakash; J. Venkateswara Rao; N. Appala Raju
Biosciences, Biotechnology Research Asia | 2016
Appala Raju; J. Venkateswara Rao; K. Vanitha Prakash; K. Mukkanti
Biomedical and Pharmacology Journal | 2015
Appala Raju; J. Venkateswara Rao; K. Vanitha Prakash; K. Mukkanti
Archive | 2010
J. V. C. Sharma; D. Satyavathi; J. Venkateswara Rao; Banjara Hills