Jaciara Miranda Gomes-Silva
University of São Paulo
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Jaciara Miranda Gomes-Silva.
Microscopy Research and Technique | 2009
Maria Angélica Hueb De Menezes Oliveira; Carolina Paes Torres; Jaciara Miranda Gomes-Silva; Michelle Alexandra Chinelatti; Fernando Carlos Hueb De Menezes; Regina Guenka Palma-Dibb; Maria Cristina Borsatto
Purpose: This study evaluated and compared in vitro the microstructure and mineral composition of permanent and deciduous teeths dental enamel. Methods: Sound third molars (n = 12) and second primary molars (n = 12) were selected and randomly assigned to the following groups, according to the analysis method performed (n = 4): Scanning electron microscopy (SEM), X‐Ray diffraction (XRD) and Energy dispersive X‐ray spectrometer (EDS). Qualitative and quantitative comparisons of the dental enamel were done. The microscopic findings were analyzed statistically by a nonparametric test (Kruskal‐Wallis). The measurements of the prisms number and thickness were done in SEM photomicrographs. The relative amounts of calcium (Ca) and phosphorus (P) were determined by EDS investigation. Chemical phases present in both types of teeth were observed by the XRD analysis. Results: The mean thickness measurements observed in the deciduous teeth enamel was 1.14 mm and in the permanent teeth enamel was 2.58 mm. The mean rod head diameter in deciduous teeth was statistically similar to that of permanent teeth enamel, and a slightly decrease from the outer enamel surface to the region next to the enamel‐dentine junction was assessed. The numerical density of enamel rods was higher in the deciduous teeth, mainly near EDJ, that showed statistically significant difference. The percentage of Ca and P was higher in the permanent teeth enamel. Conclusions: The primary enamel structure showed a lower level of Ca and P, thinner thickness and higher numerical density of rods. Microsc. Res. Tech., 2010.
Brazilian Dental Journal | 2010
Carolina Paes Torres; Michelle Alexandra Chinelatti; Jaciara Miranda Gomes-Silva; Fátima Aparecida Rizóli; Maria Angélica Hueb de Menezes Oliveira; Regina Guenka Palma-Dibb; Maria Cristina Borsatto
This study evaluated the influence of a cola-type soft drink and a soy-based orange juice on the surface and subsurface erosion of primary enamel, as a function of the exposure time. Seventy-five primary incisors were divided for microhardness test (n=45) or scanning electron microscopy (SEM) analysis (n=30). The specimens were randomly assigned to 3 groups: 1 - artificial saliva (control); 2 - cola-type soft drink; and 3 - soy-based orange juice. Immersion cycles in the beverages were undertaken under agitation for 5 min, 3 times a day, during 60 days. Surface microhardness was measured at 7, 15, 30, 45 and 60 days. After 60 days, specimens were bisected and subsurface microhardness was measured at 30, 60, 90, 120, 150 and 200 µm from the surface exposed. Data were analyzed by ANOVA and Tukeys test (a=0.05). Groups 2 and 3 presented similar decrease of surface microhardness. Regarding subsurface microhardness, group 2 presented the lowest values. SEM images revealed that after 60 days the surfaces clearly exhibited structural loss, unlike those immersed in artificial saliva. It may be concluded that erosion of the surfaces exposed to the cola-type soft drink was more accentuated and directly proportional to the exposure time.
Brazilian Dental Journal | 2008
Jaciara Miranda Gomes-Silva; Carolina Paes Torres; Marta Maria Martins Giamatei Contente; Maria Angélica Hueb de Menezes Oliveira; Regina Guenka Palma-Dibb; Maria Cristina Borsatto
This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fishers test (alpha=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (+/-4.29); II-8.57 (+/-3.19); III-7.97 (+/-2.16); IV-12.56 (+/-3.11); V-11.45 (+/-3.77); and VI-7.47 (+/-1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.
Lasers in Medical Science | 2011
Camila Scatena; Carolina Paes Torres; Jaciara Miranda Gomes-Silva; Marta Maria Martins Giamatei Contente; Jesus Djalma Pécora; Regina Guenka Palma-Dibb; Maria Cristina Borsatto
The aim of this study was to assess in vitro the influence of Er:YAG laser irradiation distance on the shear strength of the bond between an adhesive restorative system and primary dentin. A total of 60 crowns of primary molars were embedded in acrylic resin and mechanically ground to expose a flat dentin surface and were randomly assigned to six groups (nu2009=u200910). The control group was etched with 37% phosphoric acid. The remaining five groups were irradiated (80xa0mJ, 2xa0Hz) at different irradiation distances (11, 12, 16, 17 and 20xa0mm), followed by acid etching. An adhesive agent (Single Bond) was applied to the bonding sites, and resin cylinders (Filtek Z250) were prepared. The shear bond strength tests were performed in a universal testing machine (0.5xa0mm/min). Data were submitted to statistical analysis using one-way ANOVA and the Kruskal-Wallis test (p<0.05). The mean shear bond strengths were: 7.32u2009±u20093.83, 5.07u2009±u20092.62, 6.49u2009±u20091.64, 7.71u2009±u20090.66, 7.33u2009±u20090.02, and 9.65u2009±u20092.41xa0MPa in the control group and the groups irradiated at 11, 12, 16, 17, and 20xa0mm, respectively. The differences between the bond strengths in groups II and IV and between the bond strengths in groups II and VI were statistically significant (p<0.05). Increasing the laser irradiation distance resulted in increasing shear strength of the bond to primary dentin.
Brazilian Dental Journal | 2014
Camila Scatena; Daniel Galafassi; Jaciara Miranda Gomes-Silva; Maria Cristina Borsatto; Mônica Campos Serra
This study evaluated, in vitro, the erosive potential of pediatric liquid medicines in primary tooth enamel, depending on the exposure time. Sixty deciduous incisors were randomly assigned to 4 groups (n=15), according to the immersion solutions: guaifenesin; ferrous sulfate; salbutamol sulfate and artificial saliva. The immersion cycles in the medicines were undertaken under a 1-min agitation, which wasperformed three times daily, during 28 days. Surface microhardness was measured at 7,14, 21 and 28 days. The titratable acidity and buffering capacity of the immersion media were determined. Data were analyzed by Analysis of Variance and Tukeys test (α=0.05). Salbutamol sulfate caused a gradual loss in enamel microhardness deciduous, observed at all times (p<0.005). Exposure to guaifenesin or ferrous sulfate resulted in significant decrease of enamel microhardness only after 28 days (p<0.005). In the control group (artificial saliva), microhardness did not changed (p>0.005) at any of the studied times. Scanning Electron Microscopy (SEM) images revealed that after 28 days the surfaces clearly exhibited structural loss, which was unlike those immersed in artificial saliva. Erosion of deciduous enamel was dependent on the type of medicine and exposure time.
Brazilian Dental Journal | 2011
Carolina Paes Torres; Jaciara Miranda Gomes-Silva; Thalita Siqueira Mellara; Lívia Pasqualini Carvalho; Maria Cristina Borsatto
Epidermolysis bullosa (EB) is a heterogeneous group of rare genetic disorders characterized by marked fragility of the skin and mucous membranes in which vesiculobullous lesions occur in response to trauma, heat or no apparent cause. The recessive form of EB presents the greatest oral alterations including repeated blistering and scar formation leading to limited oral opening, ankyloglossia, tongue denudation, microstomia, vestibule obliteration and predisposition to oral carcinoma. Routine dental care may cause bullae formation on the lips and oral mucosa. Together with the ingestion of soft and frequently carbohydrate food, these anomalies lead to a high caries risk. This paper documents a case of a child diagnosed with recessive dystrophic epidermolysis bullosa (RDEB); describes the phases and difficulties of dental treatment and the measures that dentists and health care providers should adopt in order to provide a safe and effective dental treatment as well as earlier prevention to these patients.
Photomedicine and Laser Surgery | 2009
Andréa Soares de Oliveira Ortolan; Carolina Paes Torres; Jaciara Miranda Gomes-Silva; Maria Angélica Hueb de Menezes-Oliveira; Jesus Djalma Pécora; Regina Guenka Palma-Dibb; Maria Cristina Borsatto
OBJECTIVEnTo evaluate the ablation capacity of different energies and pulse repetition rates of an erbium-doped yttrium aluminium garnet (Er:YAG) laser on primary dentin by assessing mass loss and to analyze the surface morphology using scanning electron microscopy (SEM).nnnBACKGROUND DATAnPrevious studies have demonstrated the ability of the Er:YAG laser to ablate dentin substrate.nnnMETHODSnForty-eight sound primary molars were bisected in the mesiodistal direction. The dentin surfaces were flattened, and initial mass (mg) was obtained. A 4-mm2 area was delimited. Specimens were randomly assigned to 12 groups according to the combination of energy (160, 200, 250, and 300 mJ) and pulse repetition rate (2, 3, and 4 Hz). Er:YAG laser irradiation was performed for 20 s. After irradiation, the final mass was obtained, and specimens were prepared for SEM. The data obtained by subtracting the final mass from the initial mass were statistically analyzed using analysis of variance and Tukey test (alpha=0.05).nnnRESULTSnThe pulse repetition rate of 4 Hz provided greater mass loss, and it was different from 2 Hz and 3 HZ. The energy of 300 mJ resulted in greater mass loss, similar to 200 and 160 mJ. SEM micrographs showed dentinal tubule obliteration, structural alterations, and the presence of cracked areas in all specimens.nnnCONCLUSIONnThe settings of 160, 200, and 250 mJ at 2 and 3 Hz promoted a good ablation rate with fewer surface alterations in primary dentin.
Brazilian Dental Journal | 2012
Fábio Lourenço Romano; Rodrigo Alexandre Valério; Jaciara Miranda Gomes-Silva; José Tarcísio Lima Ferreira; Gisele Faria; Maria Cristina Borsatto
The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.
Brazilian Dental Journal | 2009
Alexandra Mussolino de Queiroz; Regina Aparecida Segatto Saiani; Cristhiane Ristum Bagatin Rossi; Jaciara Miranda Gomes-Silva; Paulo Nelson-Filho
Myelomeningocele (MMC) is a congenital malformation of the neural tube that occurs in the first weeks of pregnancy. This malformation refers to the caudal non-closure of the neural tube and neural tissue exposure, which lead to neurological problems, such as hydrocephalus, motor disability, genitourinary tract and skeletal abnormalities and mental retardation. Patients with MMC have an acknowledged predisposition to latex allergy and are usually at a high caries risk and activity due to poor oral hygiene, fermentable carbon hydrate-rich diet and prolonged use of sugar-containing medications. This paper addresses the common oral findings in pediatric patients with MMC, discusses the strategies and precautions to deal with these individuals and reports the dental care to a young child diagnosed with this condition.
European Journal of Dentistry | 2013
Maria Cristina Borsatto; Jackelline de Lemes Giuntini; Marta Maria Martins Giamatei Contente; Jaciara Miranda Gomes-Silva; Carolina Paes Torres; Rodrigo Galo
Objectives: This study evaluated the in vitro shear bond strength (SBS) of a resin-based pit-and-fissure sealant (Fluroshield [F], Dentsply/Caulk) associated with either an etch-and-rinse (Adper Single Bond 2 [SB], 3M/ESPE) or a two-step self-etch adhesive system (Adper SE Plus [SE], 3M/ESPE) on Er: YAG laser-irradiated enamel. Materials and Methods: Seventeen sound third molar crowns were embedded in acrylic resin, and the mesial-distal enamel surfaces were flattened. The enamel sites were irradiated with a 2.94-μm wavelength Er: YAG laser (120 mJ, 4 Hz, noncontact mode/17 mm, 20 s). The specimens were randomly assigned to three groups according to the bonding technique: I - 37% phosphoric acid etching + SB + F; II - SE + F and III - F applied to acid-etched enamel, without an intermediate layer of bonding agent. In all of the groups, a 3-mm diameter enamel-bonding site was demarcated and the sealant cylinders were bonded. After 24 hours in distilled water, the shear bond strength was tested at a crosshead speed of 0.5 mm/minute. The data were analyzed by one-way ANOVA and Tukey′s test. The debonded specimens were examined with a stereomicroscope to assess the failure modes. Results: The mean SBS values in MPa were I = 6.39 (±1.44); II = 9.50 (±2.79); and III = 5.26 (±1.82). No statistically significant differences were observed between groups I and III; SE/F presented a significantly higher SBS than that of the other groups (P = 0.001). With regard to the failure mode, groups I (65%) and II (75%) presented adhesive failures, while group III showed 50% adhesive failure. Cohesive failure did not occur. Conclusion: The application of the two-step self-etch bonding agent (Adper SE Plus) beneath the resin pit-and-fissure sealant placement resulted in a significantly higher bond strength for the Er:YAG laser-irradiated enamel.