Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jack Wolfsdorf is active.

Publication


Featured researches published by Jack Wolfsdorf.


Critical Care Medicine | 1999

Experimental critical care in rats: gender differences in anesthesia, ventilation, and gas exchange.

Dan Torbati; Jeronimo Ramirez; Ellis Hon; Maria T. Camacho; Jeffrey B. Sussmane; Andre Raszynski; Jack Wolfsdorf

OBJECTIVE To compare normative ventilatory and gas-exchange data and anesthetic requirements in male and female rats subjected to critical care conditions. DESIGN Prospective study. SETTING Critical care research laboratory in a hospital. SUBJECTS Twenty-two age-matched young male and female rats (Sprague-Dawley, Long Evans strain). INTERVENTIONS Anesthesia was induced with 65 and 45 mg/kg pentobarbital in male and female rats, respectively. The rats were then tracheostomized and cannulated in one femoral vein and artery. Anesthesia was maintained using 8-15 mg/kg/hr pentobarbital (iv) and controlled by continuous hemodynamic monitoring. MEASUREMENTS AND MAIN RESULTS Normoxic baselines for breathing frequency, tidal volume, minute volume, inspiratory-to-expiratory ratio, inspiratory drive (tidal volume/inspiratory time), respiratory system compliance, peak airway pressure, and gas-exchange profiles were established. Ventilatory and gas-exchange responses to oxygen and CO2 were then determined by exposure to 10 mins of hyperoxia (100% oxygen), two levels of mild and severe hypercapnic hyperoxia (inspired Pco2 of 30 and 60 torr; 4 and 8 kPa), and two levels of mild and severe normocapnic hypoxia (inspired PO2 of 81 and 48 torr; 10.7 and 6.3 kPa). The average anesthetic requirement (during a 5- to 6-hr experiment) was 30% less in the female rats than in the male rats (p < .05). Female rats showed significantly lower breathing frequency, minute volume (mL/min/kg), and inspiratory drive (mL/kg/sec) during hyperoxia, mild and severe hypercapnia, and mild hypoxia. Pulmonary peak airway pressure was significantly lower in the female rats, consistent with a significantly higher weight-indexed compliance during all exposures. The female rats also had significantly higher inspiratory-to-expiratory ratio and higher PaCO2 with lower pH during normoxia, hyperoxia, and mild hypercapnia. These gender differences had no effect on PaO2, which was similar in all exposures. CONCLUSIONS There are significant gender differences in ventilation, gas exchange, and anesthetic requirements in rats subjected to critical care conditions. The gas-exchange values observed in these spontaneously breathing rats may represent the optimal levels attainable during pentobarbital anesthesia with normal lungs. They may serve as standards for ventilator settings in the rat models used for critical care studies.


Critical Care Medicine | 1998

Acute hypercapnia increases the oxygen-carrying capacity of the blood in ventilated dogs

Dan Torbati; Martin J. Mangino; Enzo Garcia; Maria Estrada; Bala R Totapally; Jack Wolfsdorf

OBJECTIVE To test the hypothesis that PaCO2 levels generated during permissive hypercapnia may enhance arterial oxygenation, when ventilation is maintained. DESIGN Prospective study. SETTING Research laboratory in a hospital. SUBJECTS One group of eight mongrel dogs (four male; four female). INTERVENTIONS The dogs were anesthetized (30 mg/kg iv pentobarbital), intubated, and cannulated in one femoral artery and vein. While paralyzed with 0.1 mg/kg/hr iv vecouronium bromide, all subjects were ventilated with room air. Anesthesia was maintained, using 2 to 3 mg/kg/hr iv pentobarbital. Arterial hypercapnia at the levels generated during permissive hypercapnia was produced by stepwise increases in the dry, inspired Pco2 (PiCO2) (0, 30, 45, 60 and 75 torr [0, 4, 6, 8, and 10 kPa]; 15 mins each). MEASUREMENTS AND MAIN RESULTS Blood gas profiles were determined at each level of hypercapnia. The minute volume was maintained at the baseline level during all exposures. Arterial hypercapnia produced gradual and significant increases in the hemoglobin concentration. These increases were approximately 6%, 7%, 11%, and 14% at PiCO2 of 30, 45, 60, and 75 torr (4, 6, 8, and 10 kPa), respectively (p < .05; repeated analysis of variance followed by Dunnett multiple comparisons test). In parallel, the oxygen content increased by approximately 6%, 7%, 11%, and 13%, respectively. During hypercapnic trials, the PaO2 remained at the normal range, whereas the dry, inspired PO2 (PiO2) was reduced from 150 to 138 torr (20 to 18.4 kPa). The average PaO2 at the highest investigated level of arterial hypercapnia was at a normal range. The hemoglobin concentration and oxygen content returned to baseline values 30 mins after hypercapnic trials. The PaCO2 and pH became normalized 15 mins after hypercapnic trials. Indirect evidence for a similar response to hypercapnia in humans is presented. CONCLUSIONS Permissive hypercapnia due to inhaled CO2 increases oxygen-carrying capacity in dogs. The PaO2 remains at normal range even at a PiCO2 of 75 torr (10 kPa). The benefits of these effects during permissive hypercapnia, due to controlled hypoventilation, warrants investigation.


Intensive Care Medicine | 2000

Effect of hypothermia on ventilation in anesthetized, spontaneously breathing rats: theoretical implications for mechanical ventilation

Dan Torbati; Maria T. Camacho; Andre Raszynski; Jeffrey B. Sussmane; Balagangadhar R. Totapally; Karl Hultquist; Jack Wolfsdorf

Objective: To test if hypothermia, induced by a sustained pentobarbital anesthesia, in rats can reduce ventilatory demands without compromising pulmonary gas-exchange efficiency. Design: Prospective study. Setting: Research laboratory in a hospital. Subjects: One group of 11 female Sprague Dawley rats. Interventions: The rats were anesthetized with 45 mg/kg pentobarbital, tracheostomized and intubated; their femoral veins and arteries were cannulated. After surgery, anesthesia and fluid balance were maintained (10 mg/kg per h pentobarbital, and 5 ml/kg per h saline, i. v.). Rectal temperature, mean arterial blood pressure (MAP), and heart rate (HR) were continuously monitored. The respiratory variables and gas-exchange profiles were determined at 38 °C (normothermia), and during stepwise hypothermia at 37, 35, 33, 31 and 29 °C. The arterial pressure of carbon dioxide (PaCO2), pH and arterial pressure of oxygen (PaO2) during hypothermia were corrected at body temperature. Measurements and results: Graded systemic hypothermia, with maintained anesthesia, produced a strong correlation between reduction in the respiratory frequency and rectal temperature (r2 = 0.55; p < 0.0001; n = 66). The minute volume was significantly reduced, starting at 35 °C, without significant changes in the tidal volume (repeated measures of analyses of variance followed by Dunnett multiple comparisons test). No significant changes occurred in the PaCO2, pH, PaO2, hemoglobin oxygen saturation, the calculated arterial oxygen content and estimated alveolar-arterial oxygen difference during mild hypothermia (37–33 °C). The PaO2, however, was significantly reduced below 31 °C. The MAP remained stable at different levels of hypothermia, whereas HR was significantly reduced below 33 °C. Conclusions: Mild hypothermia in rats, induced by a sustained pentobarbital anesthesia, reduces ventilation without compromising arterial oxygenation or acid-base balance, as measured at body temperature. Theoretically, our observations in spontaneously breathing rats imply that a combination of mild hypothermia with anesthesia could be safely utilized to maintain adequate ventilation, using relatively low minute ventilation. We speculate that such a maneuver, if applied during mechanical ventilation, may prevent secondary pulmonary damage by allowing the use of lower ventilator volume-pressure settings.


Critical Care Medicine | 2000

Oxygen-carrying capacity during 10 hours of hypercapnia in ventilated dogs

Jeronimo Ramirez; Bala R Totapally; Ellis Hon; Dan Torbati; Martin J. Mangino; Karl Hultquist; Jack Wolfsdorf

Objective To test if a relatively long-term exogenous hypercapnia, equivalent to those maintained during permissive hypercapnia, can persistently increase oxygen-carrying capacity in ventilated dogs. Design Prospective study. Setting Research laboratory in a hospital. Subjects Six mongrel dogs (3 males; 3 females). Interventions The dogs were anesthetized (30 mg/kg pentobarbital, iv), intubated, and cannulated in one femoral artery, one femoral vein, and the right jugular vein. The mean arterial blood pressure, heart rate, and mean pulmonary artery pressure were continuously recorded. Anesthesia, fluid balance, and normothermia were maintained. Arterial hypercapnia was generated by the addition of 60 torr dry CO2 (8 kPa) to the inspired air for 10 hrs, continuously. All subjects were paralyzed (vecuronium bromide) and ventilated with room air, while the ventilator settings were kept constant. Measurements and Main Results Arterial and venous gas exchange profiles, hemoglobin concentration, oxygen saturation, oxygen content, cardiac output, and oxygen consumption were determined, before, during, and after 10 hrs of hypercapnia, periodically. Both hemoglobin concentration and oxygen content were gradually increased during hypercapnia and reached significant levels at 8 and 10 hrs of hypercapnia, respectively. These increases continued up to 2 hrs after termination of hypercapnia. The Pao2/Fio2, as an index of arterial oxygenation, was significantly increased during the first 3 hrs of hypercapnia and then remained at the normoxic level up to 10 hrs of hypercapnia. No significant changes occurred in the mean arterial blood pressure and oxygen consumption. The heart rate and cardiac output were significantly reduced at 4 and 8 hrs of hypercapnia, respectively. The mean pulmonary artery pressure was increased throughout the hypercapnic trial. Conclusions A relatively long-term exogenous hypercapnia can significantly increase oxygen-carrying capacity in normal ventilated dogs. Whether this effect can occur during permissive hypercapnia because of controlled ventilation in patients warrants investigation.


Journal of Critical Care | 1999

Experimental critical care in ventilated rats: Effect of hypercapnia on arterial oxygen-carrying capacity

Dan Torbati; Bala R Totapally; Maria T. Camacho; Jack Wolfsdorf

PURPOSE We have previously demonstrated an increased arterial O2-carrying capacity in normal ventilated dogs subjected to both acute and prolonged exogenous hypercapnia. In the present study, we tested if arterial hypercapnia, during controlled ventilation, can increase O2-carrying capacity also in rats. MATERIALS AND METHODS Twenty young male Sprague Dawley rats were anesthetized (60 mg/kg pentobarbital), tracheostomized, intubated, and one femoral vein and artery were cannulated. Anesthesia and paralysis were maintained using 15 mg/kg/h pentobarbital intravenously, and 2 mg/kg/h vecuronium bromide. The fluid balance (5 mL/kg/h saline), normothermia, and minute volume were maintained. The mean arterial blood pressure and heart rate were continuously monitored. Experiments included the following: (1) a control group, ventilated with normoxic air for 150 minutes (n = 5); (2) mild hypercapnia, a group of eight rats ventilated with normoxic air for 30 minutes and then ventilated with a mixture of normoxic air at 60 mm Hg CO2 (8 kPa) for 1 hour; and (3) severe hypercapnia, a group of seven rats were treated exactly as in group II, except a 90 mm Hg (12 kPa) CO2 during hypercapnia. Gas-exchange profile, arterial hemoglobin (Hb) concentration, arterial Hb-oxygen saturation (Hb-O2), and arterial O2 content were periodically determined during normocapnia and 1 hour of hypercapnia. RESULTS Exposures to mild and severe hypercapnia, in rats with maintained ventilation, significantly reduced the arterial O2 content by 20% and 33%, respectively, without significant changes in the arterial Hb concentration (-2%). Severe hypercapnia generated a significant reduction of -14% in the PaO2, but not in PaO2/ FiO2 ratio. CONCLUSION Rats subjected to controlled ventilation and permissive hypercapnia, unlike dogs and perhaps humans, show no augmentation of Hb concentration. Hypercapnia in rats also provokes much stronger Bohr effect than in dogs. Hypercapnia-induced Bohr effect in rats is accompanied with extreme desaturations of Hb-O2, and substantial reduction in the O2-carrying capacity. We speculate that the strong hypercapnia-induced Bohr effect in rats may prevent hypoxia at the tissue level. However, to maintain a stable oxygen-carrying capacity in rats used for pulmonary critical care studies with hypercapnia, we suggest to use hyperoxia, with or without a mild hypothermia.


Critical Care Medicine | 2001

Effects of arteriovenous extracorporeal therapy on hemodynamic stability, ventilation, and oxygenation in normal lambs.

Jeffrey B. Sussmane; Balagangadhar R. Totapally; Karl A. Hultquist; Dan Torbati; Jack Wolfsdorf

ObjectiveTo evaluate hemodynamic stability and gas exchange in a neonatal animal model of pumpless arteriovenous extracorporeal membrane oxygenation (AV-ECMO) with extracorporeal shunt flow of up to 15% of cardiac output during variable ventilation and oxygenation. DesignProspective study. SettingResearch laboratory in a hospital. SubjectsSeven lambs (5.5 ± 0.6 kg, mean ± sd). InterventionsThe lambs initially were anesthetized by 50 mg/kg ketamine intravenously. After tracheostomy, the lambs were mechanically ventilated and paralyzed by using 1 mg/kg vecuronium bromide followed by 0.1 mg·kg−1·hr−1. One femoral vein was cannulated with a pulmonary artery flotation catheter and used for cardiac output and pulmonary artery pressure measurements. A femoral artery was cannulated for measuring mean arterial blood pressure, measuring heart rate, and blood sampling for gas exchange analyses. Finally, the right internal jugular vein and carotid artery were cannulated and used for the AV-ECMO. Normothermia (38 ± 0.5°C), fluid balance (5 mL·kg−1·hr−1 normal saline), and anesthesia (5 mg·kg−1·hr−1, intravenous ketamine) were maintained. Ventilator settings were adjusted to establish a baseline Paco2 (25–35 mm Hg) at an Fio2 of 0.4. The AV-ECMO circuit was established by using a hollow fiber oxygenator, primed with maternal sheep blood (150–200 mL). Measurements and Main Results The physiologic effects of the AV-ECMO shunt were evaluated at 15, 25, and 40 mL·kg−1·hr−1 ECMO flow, corresponding roughly to 4%, 8%, and 15% of the cardiac output values. The baseline minute volume was maintained during stepwise increases in arteriovenous shunt. A significant increase in endogenous cardiac output occurred at arteriovenous shunt of 25 and 40 mL·kg−1·hr−1 (analysis of variance followed by Tukey-Kramer multiple comparisons test), which was attributed to a significant increase of 30% in the heart rate. Effective cardiac output (difference between the thermodilution value and the AV-ECMO flow rate) and mean arterial blood pressure were not significantly changed. CO2 removal, measured at 15% arteriovenous shunt, was significantly increased with decreasing ventilation to 25% and 50% of the baseline (analysis of variance and Tukey-Kramer test). Oxygenation through the membrane was measured after reducing inspired Fio2 from 0.4 to 0.21, 0.15, and 0.10 with 15% arteriovenous shunt and baseline minute ventilation. Oxygen delivery by the oxygenator was significantly increased at Fio2 of 0.10, providing a maximum of 19.5% of the total oxygen consumption at an arterial hemoglobin-oxygen saturation of 60%. ConclusionsHealthy lambs are capable of maintaining effective cardiac output in the presence of moderate arteriovenous shunts (15%). AV-ECMO may provide efficient ventilatory support in the neonatal population with hypercapnia. The amount of oxygen delivery with AV-ECMO depends on arterial desaturation.


Journal of Parenteral and Enteral Nutrition | 1986

Estimation of Nitrogen Balance Based on a Six-Hour Urine Collection in Infants

Ana Mari Lopez; Jack Wolfsdorf; Andre Raszynski; Virginia Contijoch-Serrano

The accuracy of a 6-hr vs a 24-hr urine collection for the determination of urinary urea nitrogen was studied in 15 infants. Patients age ranged from 2 weeks to 3 yr, encompassing a wide variety of diagnoses. All patients had normal renal function at the time of the study. Participants had indwelling foley catheters throughout the study. Urine specimens were collected over a continuous 24-hr period. Aliquots obtained from urine collected over 0 to 6 hr and the total urine collection were analyzed utilizing the urease enzymatic method in the Astra. Statistical analysis was performed comparing the actual 24-hr determination to the estimation based on the 6-hr collection, utilizing linear regression. The analysis of data produced a highly significant correlation (r = 0.904, p less than 0.0001). When a 24-hr urine collection is not possible, a 6-hr collection is a useful alternative for the calculation of nitrogen balance in infants.


Critical Care Medicine | 1992

Effect of extracorporeal membrane oxygenation on tobramycin pharmacokinetics in sheep.

Jens C. Möller; Jamie T. Gilman; Gregory L. Kearns; Jeffrey B. Sussmane; Andre Raszynski; Jack Wolfsdorf; Michael D. Reed

Background and MethodsCritically ill infants undergoing extracorporeal membrane oxygenation (ECMO) therapy often receive multiple pharmacologic agents. Although the disposition of many drugs has been assessed in patients undergoing cardiopulmonary bypass and in patients receiving mechanical ventilation, only limited data exist for selected medications in patients undergoing ECMO. To evaluate the potential influence of ECMO on aminoglycoside pharmacokinetics, we studied the disposition of tobramycin in ten sheep before and during ECMO therapy. Each sheep received a single iv dose of tobramycin during a control period before ECMO and on a study day during ECMO. Identically timed serial blood samples over 4 hrs were obtained after each tobramycin dose. Paired serum tobramycin concentrations were obtained pre- and postmembrane oxygenator during ECMO in six sheep. ResultsAlterations in specific pharmocokinetic variables for tobramycin were observed as a result of ECMO. Estimates of elimination halflife and volume of distribution for tobramycin were significantly increased during ECMO as compared with control (pre-ECMO) values (1.8 ±PT 0.3 vs. 2.7 ±PT 0.8 [SD] hrs [p < .01] and 0.3 ±PT 0.1 vs. 0.5 ±PT 0.2 L/kg [p < .005], respectively). Tobramycin body clearance was unaffected by the procedure (1.8 ±PT 0.8 vs. 1.7 ±PT 0.4 mL/min/kg). Paired serum tobramycin concentrations obtained pre- and postmembrane oxygenator demonstrated no drug removal. ConclusionsThese data suggest that ECMO circuitry does not sequester tobramycin and that the prolonged elimination half-life observed during ECMO therapy is not due to a change in drug clearance but is due to an ECMO-induced increase in tobramycin volume of distribution. To achieve and maintain preselected target tobramycin serum concentrations during ECMO, the usual dosage interval should remain unchanged, but the dose should be increased to compensate for the alteration in the drugs volume of distribution. The clinical applicability of these findings needs to be confirmed in carefully controlled clinical studies involving infants receiving ECMO therapy.


Critical Care | 2004

Cardiovascular stability during arteriovenous extracorporeal therapy: a randomized controlled study in lambs with acute lung injury

Balagangadhar R. Totapally; Jeffrey B. Sussmane; Dan Torbati; Javier Gelvez; Harun Fakioglu; Yongming Mao; Jose Luis Olarte; Jack Wolfsdorf

IntroductionClinical application of arteriovenous (AV) extracorporeal membrane oxygenation (ECMO) requires assessment of cardiovascular ability to respond adequately to the presence of an AV shunt in the face of acute lung injury (ALI). This ability may be age dependent and vary with the experimental model. We studied cardiovascular stability in a lamb model of severe ALI, comparing conventional mechanical ventilation (CMV) with AV-ECMO therapy.MethodsSeventeen lambs were anesthetized, tracheotomized, paralyzed, and ventilated to maintain normocapnia. Femoral and jugular veins, and femoral and carotid arteries were instrumented for the AV-ECMO circuit, systemic and pulmonary artery blood pressure monitoring, gas exchange, and cardiac output determination (thermodilution technique). A severe ALI (arterial oxygen tension/inspired fractional oxygen <200) was induced by lung lavage (repeated three times, each with 5 ml/kg saline) followed by tracheal instillation of 2.5 ml/kg of 0.1 N HCl. Lambs were consecutively assigned to CMV treatment (n = 8) or CMV plus AV-ECMO therapy using up to 15% of the cardiac output for the AV shunt flow during a 6-hour study period (n = 9). The outcome measures were the degree of inotropic and ventilator support needed to maintain hemodynamic stability and normocapnia, respectively.ResultsFive of the nine lambs subjected to AV-ECMO therapy (56%) died before completion of the 6-hour study period, as compared with two out of eight lambs (25%) in the CMV group (P > 0.05; Fishers exact test). Surviving and nonsurviving lambs in the AV-ECMO group, unlike the CMV group, required continuous volume expansion and inotropic support (P < 0.001; Fishers exact test). Lambs in the AV-ECMO group were able to maintain normocapnia with a maximum of 30% reduction in the minute ventilation, as compared with the CMV group (P < 0.05).ConclusionAV-ECMO therapy in lambs subjected to severe ALI requires continuous hemodynamic support to maintain cardiovascular stability and normocapnia, as compared with lambs receiving CMV support.


Asaio Journal | 2000

Insensible water loss during extracorporeal membrane oxygenation : An in vitro study

Teresa Camacho; Balagangadhar R. Totapally; Karl A. Hultquist; Gary Nelson; Damoon Eawaz; Jeffrey B. Sussmane; Jack Wolfsdorf

To measure insensible fluid loss from silicone membrane oxygenators during extracorporeal membrane oxygenation (ECMO), an in vitro system was used. A standard neonatal ECMO circuit (Avecor) was connected to a noncompliant reservoir, which was then primed with normal saline. The experiment was conducted by using two silicone oxygenators (Avecor 0.4 and 0.8 m2), three gas flow rates (0.5, 1.0, and 2.0 L/min) (sweep), and two fluid flow rates (200 and 400 ml/min). Two methods were used to measure the water loss. One method was to replace the water to the noncompliant circuit by using a calibrated burette, and the other method was to collect condensed water after cooling the postmembrane sweep gas to 0°C. The influence of the amount of sweep, fluid flow rate, size of membrane, and inlet and outlet sweep gas temperatures on measured water loss was statistically determined. The amount of water loss correlated with sweep (r2 = 0.81;p < 0.00001) but was not related to the fluid flow rate, membrane size, or inlet and outlet sweep gas temperature. The average daily fluid loss measured with replacement and collection methods for each liter of sweep per minute were 72.0 ± 12.6 and 62.3 ± 10.0 ml, respectively. This information may be applied to clinical practice to accurately manage fluid balance in the sick neonate on ECMO.

Collaboration


Dive into the Jack Wolfsdorf's collaboration.

Top Co-Authors

Avatar

Dan Torbati

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar

Andre Raszynski

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Karl Hultquist

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar

Bala R Totapally

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar

Maria T. Camacho

Boston Children's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Harun Fakioglu

Boston Children's Hospital

View shared research outputs
Researchain Logo
Decentralizing Knowledge