Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jacques Montreuil is active.

Publication


Featured researches published by Jacques Montreuil.


Medical Physics | 2008

Mechanically assisted 3D ultrasound guided prostate biopsy system

Jeffrey Bax; Derek W. Cool; Lori Gardi; Kerry Knight; David Smith; Jacques Montreuil; Shi Sherebrin; Cesare Romagnoli; Aaron Fenster

There are currently limitations associated with the prostate biopsy procedure, which is the most commonly used method for a definitive diagnosis of prostate cancer. With the use of two-dimensional (2D) transrectal ultrasound (TRUS) for needle-guidance in this procedure, the physician has restricted anatomical reference points for guiding the needle to target sites. Further, any motion of the physicians hand during the procedure may cause the prostate to move or deform to a prohibitive extent. These variations make it difficult to establish a consistent reference frame for guiding a needle. We have developed a 3D navigation system for prostate biopsy, which addresses these shortcomings. This system is composed of a 3D US imaging subsystem and a passive mechanical arm to minimize prostate motion. To validate our prototype, a series of experiments were performed on prostate phantoms. The 3D scan of the string phantom produced minimal geometric distortions, and the geometric error of the 3D imaging subsystem was 0.37 mm. The accuracy of 3D prostate segmentation was determined by comparing the known volume in a certified phantom to a reconstructed volume generated by our system and was shown to estimate the volume with less then 5% error. Biopsy needle guidance accuracy tests in agar prostate phantoms showed that the mean error was 2.1 mm and the 3D location of the biopsy core was recorded with a mean error of 1.8 mm. In this paper, we describe the mechanical design and validation of the prototype system using an in vitro prostate phantom. Preliminary results from an ongoing clinical trial show that prostate motion is small with an in-plane displacement of less than 1 mm during the biopsy procedure.


Radiology | 2012

Prostate: Registration of Digital Histopathologic Images to in Vivo MR Images Acquired by Using Endorectal Receive Coil

Aaron D. Ward; Cathie Crukley; Charles A. McKenzie; Jacques Montreuil; Eli Gibson; Cesare Romagnoli; Jose A. Gomez; Madeleine Moussa; Joseph L. Chin; Glenn Bauman; Aaron Fenster

PURPOSE To develop and evaluate a technique for the registration of in vivo prostate magnetic resonance (MR) images to digital histopathologic images by using image-guided specimen slicing based on strand-shaped fiducial markers relating specimen imaging to histopathologic examination. MATERIALS AND METHODS The study was approved by the institutional review board (the University of Western Ontario Health Sciences Research Ethics Board, London, Ontario, Canada), and written informed consent was obtained from all patients. This work proposed and evaluated a technique utilizing developed fiducial markers and real-time three-dimensional visualization in support of image guidance for ex vivo prostate specimen slicing parallel to the MR imaging planes prior to digitization, simplifying the registration process. Means, standard deviations, root-mean-square errors, and 95% confidence intervals are reported for all evaluated measurements. RESULTS The slicing error was within the 2.2 mm thickness of the diagnostic-quality MR imaging sections, with a tissue block thickness standard deviation of 0.2 mm. Rigid registration provided negligible postregistration overlap of the smallest clinically important tumors (0.2 cm(3)) at histologic examination and MR imaging, whereas the tested nonrigid registration method yielded a mean target registration error of 1.1 mm and provided useful coregistration of such tumors. CONCLUSION This method for the registration of prostate digital histopathologic images to in vivo MR images acquired by using an endorectal receive coil was sufficiently accurate for coregistering the smallest clinically important lesions with 95% confidence.


Medical Physics | 2011

A compact mechatronic system for 3D ultrasound guided prostate interventions.

Jeffrey Bax; David Smith; Laura Bartha; Jacques Montreuil; Shi Sherebrin; Lori Gardi; Chandima Edirisinghe; Aaron Fenster

PURPOSE Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. METHODS The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. RESULTS To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 degree from the preplanned trajectory. At oblique angles of up to 15 degrees relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 degrees. CONCLUSIONS By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physicians ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.


medical image computing and computer-assisted intervention | 2010

Registration of in vivo prostate magnetic resonance images to digital histopathology images

Aaron D. Ward; Cathie Crukley; Charles A. McKenzie; Jacques Montreuil; Eli Gibson; Jose A. Gomez; Madeleine Moussa; Glenn Bauman; Aaron Fenster

Early and accurate diagnosis of prostate cancer enables minimally invasive therapies to cure the cancer with less morbidity. The purpose of this work is to non-rigidly register in vivo pre-prostatectomy prostate medical images to regionally-graded histopathology images from post-prostatectomy specimens, seeking a relationship between the multi parametric imaging and cancer distribution and aggressiveness. Our approach uses image-based registration in combination with a magnetically tracked probe to orient the physical slicing of the specimen to be parallel to the in vivo imaging planes, yielding a tractable 2D registration problem. We measured a target registration error of 0.85 mm, a mean slicing plane marking error of 0.7 mm, and a mean slicing error of 0.6 mm; these results compare favourably with our 2.2 mm diagnostic MR image thickness. Qualitative evaluation of in vivo imaging-histopathology fusion reveals excellent anatomic concordance between MR and digital histopathology.


Brachytherapy | 2016

Three-dimensional transrectal ultrasound guided high-dose-rate prostate brachytherapy: A comparison of needle segmentation accuracy with two-dimensional image guidance

William Thomas Hrinivich; Douglas A. Hoover; Kathleen Surry; Chandima Edirisinghe; Jacques Montreuil; David D'Souza; Aaron Fenster; Eugene Wong

PURPOSE Conventional transrectal ultrasound guided high-dose-rate prostate brachytherapy (HDR-BT) uses an axially acquired image set for organ segmentation and 2D sagittal images for needle segmentation. Sagittally reconstructed 3D (SR3D) transrectal ultrasound enables both organ and needle segmentation and has the potential to reduce organ-needle alignment uncertainty. This study compares the accuracy of needle tip localization between the conventional 2D sagittally assisted axially reconstructed (SAAR) and SR3D approaches. METHODS AND MATERIALS Twelve patients underwent SAAR-guided HDR-BT, during which SR3D images were acquired for subsequent segmentation and analysis. A total of 183 needles were investigated. Needle end-length measurements were taken, providing a gold standard for insertion depths. Dosimetric impact of insertion depth errors (IDEs) on clinical treatment plans was assessed. RESULTS SR3D guidance provided statistically significantly smaller IDEs than SAAR guidance with a mean ± SD of -0.6 ± 3.2 mm and 2.8 ± 3.2 mm, respectively (p < 0.001). Shadow artifacts were found to obstruct the view of some needle tips in SR3D images either partially (12%) or fully (10%); however, SR3D IDEs had a statistically significantly smaller impact on prostate V100% than SAAR IDEs with mean ± SD decreases of -1.2 ± 1.3% and -6.5 ± 6.7%, respectively (p < 0.05). CONCLUSIONS SR3D-guided HDR-BT eliminates a source of systematic uncertainty from the SAAR-guided approach, providing decreased IDEs for most needles, leading to a significant decrease in dosimetric uncertainty. Although imaging artifacts can limit the accuracy of tip localization in a subset of needles, we identified a method to mitigate these artifacts for clinical implementation.


medical image computing and computer assisted intervention | 2010

Evaluation of inter-session 3D-TRUS to 3D-TRUS image registration for repeat prostate biopsies

Vaishali V. Karnik; Aaron Fenster; Jeff Bax; Lori Gardi; Igor Gyacskov; Jacques Montreuil; Cesare Romagnoli; Aaron D. Ward

To ensure accurate targeting and repeatability, 3D TRUS-guided biopsies require registration to determine coordinate transformations to (1) incorporate pre-procedure biopsy plans and (2) compensate for inter-session prostate motion and deformation between repeat biopsy sessions. We evaluated prostate surface- and image-based 3D-to-3D TRUS registration by measuring the TRE of manually marked, corresponding, intrinsic fiducials in the whole gland and peripheral zone, and also evaluated the error anisotropy. The image-based rigid and non-rigid methods yielded the best results with mean TREs of 2.26 mm and 1.96 mm, respectively. These results compare favorably with a clinical need for an error of less than 2.5 mm.


Medical Physics | 2015

Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

Éric Poulin; Lori Gardi; Kevin Barker; Jacques Montreuil; Aaron Fenster; Luc Beaulieu

PURPOSE In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. METHODS For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. RESULTS The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. CONCLUSIONS A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.


Medical Imaging 2007: Visualization and Image-Guided Procedures | 2007

A compact robotic apparatus and method for 3-D ultrasound guided prostate therapy

Jeffrey Bax; Lori Gardi; Jacques Montreuil; David Smith; Aaron Fenster

Ultrasound imaging has revolutionized the treatment of prostate cancer by producing increasingly accurate models of the prostate and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. Three-dimensional (3D) ultrasound imaging, which allows 3D models of the prostate to be constructed from a series of two-dimensional images, helps to accurately target and implant seeds into the prostate. We have developed a compact robotic apparatus, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This device has been designed to accurately guide a needle in 3D space so that the needle can be inserted into the prostate at an angle that does not interfere with the pubic arch. The physician can adjust manually or automatically the position of the apparatus in order to place several radioactive seeds into the prostate at designated target locations. Because many physicians are wary of conducting robotic surgical procedures, the apparatus has been developed so that the physician can position the needle for manual insertion and apply a method for manually releasing the needle without damaging the apparatus or endangering the patient.


Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling | 2008

3D transrectal ultrasound prostate biopsy using a mechanical imaging and needle-guidance system

Jeffrey Bax; Derek W. Cool; Lori Gardi; Jacques Montreuil; Elena Gil; Jeremy Bluvol; Kerry Knight; David Smith; Cesare Romagnoli; Aaron Fenster

Prostate biopsy procedures are generally limited to 2D transrectal ultrasound (TRUS) imaging for biopsy needle guidance. This limitation results in needle position ambiguity and an insufficient record of biopsy core locations in cases of prostate re-biopsy. We have developed a multi-jointed mechanical device that supports a commercially available TRUS probe with an integrated needle guide for precision prostate biopsy. The device is fixed at the base, allowing the joints to be manually manipulated while fully supporting its weight throughout its full range of motion. Means are provided to track the needle trajectory and display this trajectory on a corresponding TRUS image. This allows the physician to aim the needle-guide at predefined targets within the prostate, providing true 3D navigation. The tracker has been designed for use with several end-fired transducers that can be rotated about the longitudinal axis of the probe to generate 3D images. The tracker reduces the variability associated with conventional hand-held probes, while preserving user familiarity and procedural workflow. In a prostate phantom, biopsy needles were guided to within 2 mm of their targets, and the 3D location of the biopsy core was accurate to within 3 mm. The 3D navigation system is validated in the presence of prostate motion in a preliminary patient study.


Proceedings of SPIE | 2016

A comparison of needle tip localization accuracy using 2D and 3D trans-rectal ultrasound for high-dose-rate prostate cancer brachytherapy treatment planning

W. Thomas Hrinivich; Douglas A. Hoover; Kathleen Surry; Chandima Edirisinghe; Jacques Montreuil; David D'Souza; Aaron Fenster; Eugene Wong

Background: High-dose-rate brachytherapy (HDR-BT) is a prostate cancer treatment option involving the insertion of hollow needles into the gland through the perineum to deliver a radioactive source. Conventional needle imaging involves indexing a trans-rectal ultrasound (TRUS) probe in the superior/inferior (S/I) direction, using the axial transducer to produce an image set for organ segmentation. These images have limited resolution in the needle insertion direction (S/I), so the sagittal transducer is used to identify needle tips, requiring a manual registration with the axial view. This registration introduces a source of uncertainty in the final segmentations and subsequent treatment plan. Our lab has developed a device enabling 3D-TRUS guided insertions with high S/I spatial resolution, eliminating the need to align axial and sagittal views. Purpose: To compare HDR-BT needle tip localization accuracy between 2D and 3D-TRUS. Methods: 5 prostate cancer patients underwent conventional 2D TRUS guided HDR-BT, during which 3D images were also acquired for post-operative registration and segmentation. Needle end-length measurements were taken, providing a gold standard for insertion depths. Results: 73 needles were analyzed from all 5 patients. Needle tip position differences between imaging techniques was found to be largest in the S/I direction with mean±SD of -2.5±4.0 mm. End-length measurements indicated that 3D TRUS provided statistically significantly lower mean±SD insertion depth error of -0.2±3.4 mm versus 2.3±3.7 mm with 2D guidance (p < .001). Conclusions: 3D TRUS may provide more accurate HDR-BT needle localization than conventional 2D TRUS guidance for the majority of HDR-BT needles.

Collaboration


Dive into the Jacques Montreuil's collaboration.

Top Co-Authors

Avatar

Aaron Fenster

University of Western Ontario

View shared research outputs
Top Co-Authors

Avatar

Lori Gardi

Robarts Research Institute

View shared research outputs
Top Co-Authors

Avatar

Jeffrey Bax

University of Western Ontario

View shared research outputs
Top Co-Authors

Avatar

Cesare Romagnoli

University of Western Ontario

View shared research outputs
Top Co-Authors

Avatar

Aaron D. Ward

University of Western Ontario

View shared research outputs
Top Co-Authors

Avatar

David Smith

Robarts Research Institute

View shared research outputs
Top Co-Authors

Avatar

Cathie Crukley

University of Western Ontario

View shared research outputs
Top Co-Authors

Avatar

Charles A. McKenzie

University of Western Ontario

View shared research outputs
Top Co-Authors

Avatar

Derek W. Cool

University of Western Ontario

View shared research outputs
Top Co-Authors

Avatar

Glenn Bauman

University of Western Ontario

View shared research outputs
Researchain Logo
Decentralizing Knowledge