Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jae-Min Seo is active.

Publication


Featured researches published by Jae-Min Seo.


The Journal of Advanced Prosthodontics | 2010

Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study

Si Hoon Jo; Kyoung Il Kim; Jae-Min Seo; Kwang Yeob Song; Ju-Mi Park; Seung Geun Ahn

PURPOSE The purpose of this study was to compare the accuracy of the implant master cast according to the type (pick-up, transfer) and the length (long, short) of the impression copings. MATERIALS AND METHODS The metal master cast was fabricated with three internal connection type implant analogs (Osstem GS III analog), embedded parallel and with 10° of mesial angulation to the center analog. Four types of impression coping were prepared with different combinations of types (transfer, pick-up) and lengths (long, short) of the coping. The impressions were made using vinyl polysiloxane (one step, heavy + light body) with an individual tray, and 10 impressions were made for each group. Eventually, 40 experimental casts were produced. Then, the difference in the distance between the master cast and the experimental cast were measured, and the error rate was determined. The analysis of variance was performed using the SPSS (v 12.0) program (α = .05), and the statistical significance was set at P < .05. RESULTS The ANOVA showed that the pick-up type impression coping exhibited a significantly lower error rate than the transfer type. However, no significant difference was observed with respect to the length of the impression coping. Additionally, no significant difference was observed between the parallel and mesial angulated groups. CONCLUSION Within the limitations of this study, the pick-up type impression coping exhibited a more accurate implant master cast than the transfer type in parallel group. The accuracy of the implant master cast did not differ for different lengths of impression coping of at least 11 mm. Additionally, the accuracy of the implant cast was not different for the parallel and 10° mesial angulated groups.


The Journal of Advanced Prosthodontics | 2015

Evaluation of shear bond strength between dual cure resin cement and zirconia ceramic after thermocycling treatment

Jung-Jin Lee; Cheol-Kyun Kang; Ju-Won Oh; Jae-Min Seo; Ju-Mi Park

PURPOSE This study was performed to evaluate shear bond strength (SBS) between three dual-cured resin cements and silica coated zirconia, before and after thermocycling treatment. MATERIALS AND METHODS Sixty specimens were cut in 15 × 2.75 mm discs using zirconia. After air blasting of 50 µm alumina, samples were prepared by tribochemical silica coating with Rocatec™ plus. The specimens were divided into three groups according to the dual-cure resin cement used: (1) Calibra silane+Calibra®, (2) Monobond S+Multilink® N and (3) ESPN sil+RelyX™ Unicem Clicker. After the resin cement was bonded to the zirconia using a Teflon mold, photopolymerization was carried out. Only 10 specimens in each group were thermocycled 6,000 times. Depending on thermocycling treatment, each group was divided into two subgroups (n=10) and SBS was measured by applying force at the speed of 1 mm/min using a universal testing machine. To find out the differences in SBS according to the types of cements and thermocycling using the SPSS, two-way ANOVA was conducted and post-hoc analysis was performed by Turkeys test. RESULTS In non-thermal aged groups, SBS of Multilink group (M1) was higher than that of Calibra (C1) and Unicem (U1) group (P<.05). Moreover, even after thermocycling treatment, SBS of Multilink group (M2) was higher than the other groups (C2 and U2). All three cements showed lower SBS after the thermocycling than before the treatments. But Multilink and Unicem had a significant difference (P<.05). CONCLUSION In this experiment, Multilink showed the highest SBS before and after thermocycling. Also, bond strengths of all three cements decreased after thermocycling.


The International Journal of Biochemistry & Cell Biology | 2015

Role of transcription factor Sp1 in the 4-O-methylhonokiol-mediated apoptotic effect on oral squamous cancer cells and xenograft

Jin Hyoung Cho; Ra Ham Lee; Young Joo Jeon; Jae Cheon Shin; Seon Min Park; Nag Jin Choi; Kang Seok Seo; Goo Yoon; Seung Sik Cho; Ka Hwi Kim; Jung Jae Cho; Young Sik Cho; Dae Hwan Kim; Jin Tae Hong; Tae-Hoon Lee; Hong Ju Park; Seunggon Jung; Jae-Min Seo; Hanyong Chen; Zigang Dong; Jung Il Chae; Jung Hyun Shim

Recently, biphenolic components derived from the Magnolia family have been studied for anti-cancer, anti-stress, and anti-inflammatory pharmacological effects. However, the pharmacological mechanism of action of 4-O-methylhonokiol (MH) is not clear in oral cancer. The aim of this study was to investigate the role of MH in apoptosis and its molecular mechanism in oral squamous cell carcinoma (OSCC) cell lines, HN22 and HSC4, as well as tumor xenografts. Here, we demonstrated that MH decreased cell growth and induced apoptosis in HN22 and HSC4 cells through the regulation of specificity protein 1 (Sp1). We employed several experimental techniques such as MTS assay, DAPI staining, PI staining, Annexin-V/7-ADD staining, RT-PCR, western blot analysis, immunocytochemistry, immunohistochemistry, TUNEL assay and in vivo xenograft model analysis. MH inhibited Sp1 protein expression and reduced Sp1 protein levels via both proteasome-dependent protein degradation and inhibition of protein synthesis in HN22 and HSC4 cells; MH did not alter Sp1 mRNA levels. We found that MH directly binds Sp1 by Sepharose 4B pull-down assay and molecular modeling. In addition, treatment with MH or knocking down Sp1 expression suppressed oral cancer cell colony formation. Moreover, MH treatment effectively inhibited tumor growth and Sp1 levels in BALB/c nude mice bearing HN22 cell xenografts. These results indicated that MH inhibited cell growth, colony formation and also induced apoptosis via Sp1 suppression in OSCC cells and xenograft tumors. Thus, MH is a potent anti-cancer drug candidate for oral cancer.


The Journal of Advanced Prosthodontics | 2015

Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

Jung-Jin Lee; Kwang-Yeob Song; Seung-Geun Ahn; Jung-Yun Choi; Jae-Min Seo; Ju-Mi Park

PURPOSE The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens (10×10×1.5 mm) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbeccos modified Eagles medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukeys tests. RESULTS The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity.


The Journal of Advanced Prosthodontics | 2015

Effects of core characters and veneering technique on biaxial flexural strength in porcelain fused to metal and porcelain veneered zirconia

Ju-Won Oh; Kwang-Yeob Song; Seung-Geun Ahn; Ju-Mi Park; Min-Ho Lee; Jae-Min Seo

PURPOSE The purpose of this study was to assess the impact of the core materials, thickness and fabrication methods of veneering porcelain on prosthesis fracture in the porcelain fused to metal and the porcelain veneered zirconia. MATERIALS AND METHODS Forty nickel-chrome alloy cores and 40 zirconia cores were made. Half of each core group was 0.5 mm-in thickness and the other half was 1.0 mm-in thickness. Thus, there were four groups with 20 cores/group. Each group was divided into two subgroups with two different veneering methods (conventional powder/liquid layering technique and the heat-pressing technique). Tensile strength was measured using the biaxial flexural strength test based on the ISO standard 6872:2008 and Weibull analysis was conducted. Factors influencing fracture strength were analyzed through three-way ANOVA (α≤.05) and the influence of core thickness and veneering method in each core materials was assessed using two-way ANOVA (α≤.05). RESULTS The biaxial flexural strength test showed that the fabrication method of veneering porcelain has the largest impact on the fracture strength followed by the core thickness and the core material. In the metal groups, both the core thickness and the fabrication method of the veneering porcelain significantly influenced on the fracture strength, while only the fabrication method affected the fracture strength in the zirconia groups. CONCLUSION The fabrication method is more influential to the strength of a prosthesis compared to the core character determined by material and thickness of the core.


The Journal of Advanced Prosthodontics | 2017

Influence of nano-structured alumina coating on shear bond strength between Y-TZP ceramic and various dual-cured resin cements

Jung-Jin Lee; Jung-Yun Choi; Jae-Min Seo

PURPOSE The purpose of this study was to evaluate the effect of nano-structured alumina surface coating on shear bond strength between Y-TZP ceramic and various dual-cured resin cements. MATERIALS AND METHODS A total of 90 disk-shaped zirconia specimens (HASS CO., Gangneung, Korea) were divided into three groups by surface treatment method: (1) airborne particle abrasion, (2) tribochemicalsilica coating, and (3) nano-structured alumina coating. Each group was categorized into three subgroups of ten specimens and bonded with three different types of dual-cured resin cements. After thermocycling, shear bond strength was measured and failure modes were observed through FE-SEM. Two-way ANOVA and the Tukeys HSD test were performed to determine the effects of surface treatment method and type of cement on bond strength (P<.05). To confirm the correlation of surface treatment and failure mode, the Chi-square test was used. RESULTS Groups treated with the nanostructured alumina coating showed significantly higher shear bond strength compared to other groups treated with airborne particle abrasion or tribochemical silica coating. Clearfil SA Luting showed a significantly higher shear bond strength compared to RelyX ARC and RelyX Unicem. The cohesive failure mode was observed to be dominant in the groups treated with nano-structured alumina coating, while the adhesive failure mode was prevalent in the groups treated with either airborne particle abrasion or tribochemical silica coating. CONCLUSION Nano-structured alumina coating is an effective zirconia surface treatment method for enhancing the bond strength between Y-TZP ceramic and various dual-cured resin cements.


Journal of Prosthetic Dentistry | 2017

A technique for minimizing subgingival residual cement by using rubber dam for cement-retained implant crowns

Chi-Won Seo; Jae-Min Seo

Excellent esthetics and a passive fit are facilitated by using cement-retained prostheses. However, eliminating residual cement is difficult in the subgingival area. Residual cement may cause periimplantitis, gingival swelling, pain, bleeding on probing, and other complications. Generally, the margin of an anterior implant crown is placed in the subgingival area for esthetic reasons. Because removing residual cement in subgingival areas is difficult, techniques using abutment replicas or Teflon tape have been introduced to minimize the problem. The presented technique uses rubber dam to allow only the minimal amount of residual cement to flow into the subgingival area when cement-retained prostheses


Asian-australasian Journal of Animal Sciences | 2016

Regional Differences of Proteins Expressing in Adipose Depots Isolated from Cows, Steers and Bulls as Identified by a Proteomic Approach

Jin Hyoung Cho; Jin Young Jeong; Ra Ham Lee; Mi Na Park; Seokho Kim; Seon-Min Park; Jae-Cheon Shin; Young-Joo Jeon; Jung-Hyun Shim; Nag-Jin Choi; Kang Seok Seo; Young Sik Cho; Minseok S. Kim; Sungho Ko; Jae-Min Seo; Seung-Youp Lee; Jung-Il Chae; Hyun-Jeong Lee

Adipose tissue in the loin muscle area of beef cattle as a marbling factor is directly associated with beef quality. To elucidate whether properties of proteins involved in depot specific adipose tissue were sex-dependent, we analyzed protein expression of intramuscular adipose tissue (IMAT) and omental adipose tissue (OMAT) from Hanwoo cows, steers, and bulls of Korean native beef cattle by liquid chromatography-tandem mass spectrometry (LC-MS/MS)–based proteomic analysis, quantitative polymerase chain reaction (PCR) and western blot analysis. Two different adipose depots (i.e. intramuscular and omental) were collected from cows (n = 7), steers (n = 7), or bulls (n = 7). LC-MS/MS revealed a total of 55 and 35 proteins in IMAT and OMAT, respectively. Of the 55 proteins identified, 44, 40, and 42 proteins were confirmed to be differentially expressed in IMAT of cows, steers, and bulls, respectively. In OMAT of cows, steers, and bulls, 33, 33, and 22 were confirmed to be differentially expressed, respectively. Tropomyosin (TPM) 1, TPM 2, and TPM3 were subjected to verification by quantitative PCR and western blot analysis in IMAT and OMAT of Hanwoo cows, steers, and bulls as key factors closely associated with muscle development. Both mRNA levels and protein levels of TPM1, TPM2, and TPM3 in IMAT were lower in bulls compared to in cows or steers suggesting that they were positively correlated with marbling score and quality grade. Our results may aid the regulation of marbling development and improvement of meat quality grades in beef cattle.


The Journal of Advanced Prosthodontics | 2014

Fabrication of a metal-ceramic crown to fit an existing partial removable dental prosthesis using ceramic pressed to metal technique: a clinical report

Jae-Min Seo; Seung-Geun Ahn

Fabricating a crown to retrofit an existing abutment tooth for a partial removable dental prosthesis (PRDP) is one of the most time-consuming and labor-intensive clinical procedures. In particular, when the patient is concerned with esthetic aspects of restoration, the task of fabricating becomes more daunting. Many techniques for the fabrication of all-metallic or metal-ceramic crowns have been discussed in the literature. This article was aimed to describe a simple fabrication method in which a retrofitting crown was fabricated for a precise fit using a ceramic-pressed-to-metal system.


The Journal of Advanced Prosthodontics | 2012

Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report

Jun-Won Hong; Seung-Geun Ahn; Dae-Ho Leem; Jae-Min Seo

Conventional implant protocols required a load-free healing period of three to six months between placement and functional loading of the implants. Many efforts have been made to minimize the duration of treatment time. Several literatures have documented immediate function with provisional or definitive prosthesis within a week of the placement in response to these demands. In addition, immediate implant placement has advantages such as shortened treatment time and preservation of soft tissue architectures. This article presents immediate implant placement into fresh extraction sockets followed by functional immediate loading with provisional prosthesis on canine and premolars for a patient having canine protected occlusion.

Collaboration


Dive into the Jae-Min Seo's collaboration.

Top Co-Authors

Avatar

Jung-Jin Lee

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Ju-Mi Park

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Seung-Geun Ahn

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Kyoung-A Kim

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Kwang-Yeob Song

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Ra Ham Lee

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Jae-Cheon Shin

Mokpo National University

View shared research outputs
Top Co-Authors

Avatar

Jin Hyoung Cho

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Jung-Il Chae

Chonbuk National University

View shared research outputs
Top Co-Authors

Avatar

Young-Joo Jeon

Chonbuk National University

View shared research outputs
Researchain Logo
Decentralizing Knowledge