International Journal of Radiation Oncology Biology Physics | 2015

Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences

Jason Dowling; Jidi Sun; Peter Pichler; David Rivest-Hénault; Soumya Ghose; Haylea Richardson; Chris Wratten; Jarad Martin; Jameen Arm; Leah Best; Shekhar S. Chandra; Jurgen Fripp; F. W. Menk; Peter B. Greer

PURPOSE To validate automatic substitute computed tomography CT (sCT) scans generated from standard T2-weighted (T2w) magnetic resonance (MR) pelvic scans for MR-Sim prostate treatment planning. PATIENTS AND METHODS A Siemens Skyra 3T MR imaging (MRI) scanner with laser bridge, flat couch, and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole-pelvis MRI scan (1.6 mm 3-dimensional isotropic T2w SPACE [Sampling Perfection with Application optimized Contrasts using different flip angle Evolution] sequence) was acquired. Three additional small field of view scans were acquired: T2w, T2*w, and T1w flip angle 80° for gold fiducials. Patients received a routine planning CT scan. Manual contouring of the prostate, rectum, bladder, and bones was performed independently on the CT and MR scans. Three experienced observers contoured each organ on MRI, allowing interobserver quantification. To generate a training database, each patient CT scan was coregistered to their whole-pelvis T2w using symmetric rigid registration and structure-guided deformable registration. A new multi-atlas local weighted voting method was used to generate automatic contours and sCT results. RESULTS The mean error in Hounsfield units between the sCT and corresponding patient CT (within the body contour) was 0.6 ± 14.7 (mean ± 1 SD), with a mean absolute error of 40.5 ± 8.2 Hounsfield units. Automatic contouring results were very close to the expert interobserver level (Dice similarity coefficient): prostate 0.80 ± 0.08, bladder 0.86 ± 0.12, rectum 0.84 ± 0.06, bones 0.91 ± 0.03, and body 1.00 ± 0.003. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same dose prescription was found to be 0.3% ± 0.8%. The 3-dimensional γ pass rate was 1.00 ± 0.00 (2 mm/2%). CONCLUSIONS The MR-Sim setup and automatic sCT generation methods using standard MR sequences generates realistic contours and electron densities for prostate cancer radiation therapy dose planning and digitally reconstructed radiograph generation.


Physics in Medicine and Biology | 2015

MRI simulation: end-to-end testing for prostate radiation therapy using geometric pelvic MRI phantoms.

Jidi Sun; Jason Dowling; Peter Pichler; F. W. Menk; David Rivest-Hénault; Jonathan Lambert; Joel Parker; Jameen Arm; Leah Best; Jarad Martin; James W. Denham; Peter B. Greer

To clinically implement MRI simulation or MRI-alone treatment planning requires comprehensive end-to-end testing to ensure an accurate process. The purpose of this study was to design and build a geometric phantom simulating a human male pelvis that is suitable for both CT and MRI scanning and use it to test geometric and dosimetric aspects of MRI simulation including treatment planning and digitally reconstructed radiograph (DRR) generation.A liquid filled pelvic shaped phantom with simulated pelvic organs was scanned in a 3T MRI simulator with dedicated radiotherapy couch-top, laser bridge and pelvic coil mounts. A second phantom with the same external shape but with an internal distortion grid was used to quantify the distortion of the MR image. Both phantoms were also CT scanned as the gold-standard for both geometry and dosimetry. Deformable image registration was used to quantify the MR distortion. Dose comparison was made using a seven-field IMRT plan developed on the CT scan with the fluences copied to the MR image and recalculated using bulk electron densities. Without correction the maximum distortion of the MR compared with the CT scan was 7.5 mm across the pelvis, while this was reduced to 2.6 and 1.7 mm by the vendors 2D and 3D correction algorithms, respectively. Within the locations of the internal organs of interest, the distortion was <1.5 and <1 mm with 2D and 3D correction algorithms, respectively. The dose at the prostate isocentre calculated on CT and MRI images differed by 0.01% (1.1 cGy). Positioning shifts were within 1 mm when setup was performed using MRI generated DRRs compared to setup using CT DRRs.The MRI pelvic phantom allows end-to-end testing of the MRI simulation workflow with comparison to the gold-standard CT based process. MRI simulation was found to be geometrically accurate with organ dimensions, dose distributions and DRR based setup within acceptable limits compared to CT.


International Journal of Radiation Oncology Biology Physics | 2016

Audiovisual Biofeedback Improves Cine–Magnetic Resonance Imaging Measured Lung Tumor Motion Consistency

Danny Lee; Peter B. Greer; Joanna Ludbrook; Jameen Arm; Perry Hunter; Sean Pollock; Kuldeep Makhija; R. O'Brien; Taeho Kim; P Keall

PURPOSE To assess the impact of an audiovisual (AV) biofeedback on intra- and interfraction tumor motion for lung cancer patients. METHODS AND MATERIALS Lung tumor motion was investigated in 9 lung cancer patients who underwent a breathing training session with AV biofeedback before 2 3T magnetic resonance imaging (MRI) sessions. The breathing training session was performed to allow patients to become familiar with AV biofeedback, which uses a guiding wave customized for each patient according to a reference breathing pattern. In the first MRI session (pretreatment), 2-dimensional cine-MR images with (1) free breathing (FB) and (2) AV biofeedback were obtained, and the second MRI session was repeated within 3-6 weeks (mid-treatment). Lung tumors were directly measured from cine-MR images using an auto-segmentation technique; the centroid and outlier motions of the lung tumors were measured from the segmented tumors. Free breathing and AV biofeedback were compared using several metrics: intra- and interfraction tumor motion consistency in displacement and period, and the outlier motion ratio. RESULTS Compared with FB, AV biofeedback improved intrafraction tumor motion consistency by 34% in displacement (P=.019) and by 73% in period (P<.001). Compared with FB, AV biofeedback improved interfraction tumor motion consistency by 42% in displacement (P<.046) and by 74% in period (P=.005). Compared with FB, AV biofeedback reduced the outlier motion ratio by 21% (P<.001). CONCLUSIONS These results demonstrated that AV biofeedback significantly improved intra- and interfraction lung tumor motion consistency for lung cancer patients. These results demonstrate that AV biofeedback can facilitate consistent tumor motion, which is advantageous toward achieving more accurate medical imaging and radiation therapy procedures.


Journal of Physics: Conference Series | 2014

Audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI

Danny Lee; Peter B. Greer; Jameen Arm; P Keall; Taeho Kim

The purpose of this study was to test the hypothesis that audiovisual (AV) biofeedback can improve image quality and reduce scan time for respiratory-gated 3D thoracic MRI. For five healthy human subjects respiratory motion guidance in MR scans was provided using an AV biofeedback system, utilizing real-time respiratory motion signals. To investigate the improvement of respiratory-gated 3D MR images between free breathing (FB) and AV biofeedback (AV), each subject underwent two imaging sessions. Respiratory-related motion artifacts and imaging time were qualitatively evaluated in addition to the reproducibility of external (abdominal) motion. In the results, 3D MR images in AV biofeedback showed more anatomic information such as a clear distinction of diaphragm, lung lobes and sharper organ boundaries. The scan time was reduced from 401±215 s in FB to 334±94 s in AV (p-value 0.36). The root mean square variation of the displacement and period of the abdominal motion was reduced from 0.4±0.22 cm and 2.8±2.5 s in FB to 0.1±0.15 cm and 0.9±1.3 s in AV (p- value of displacement <0.01 and p-value of period 0.12). This study demonstrated that audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI. These results suggest that AV biofeedback has the potential to be a useful motion management tool in medical imaging and radiation therapy procedures.


British Journal of Radiology | 2014

MR simulation for prostate radiation therapy: effect of coil mounting position on image quality.

Jidi Sun; Peter Pichler; Jason Dowling; F. W. Menk; Peter Stanwell; Jameen Arm; Peter B. Greer

OBJECTIVE To eliminate the effects of body deformation for MR-based prostate treatment planning, coil mounts are essential. In this study, we evaluated the effect of the coil set-up on image quality. METHODS A custom-designed pelvic-shaped phantom was scanned by systematically increasing the anterior body-to-coil (BTC) distance from 30 to 90 mm. The image quality near the organs of interest was determined in order to characterize the relationship between image quality and BTC distance at the critical organ structures. The half intensity reduction (HIR) was calculated to determine the sensitivity of each organ structure to the BTC distance change. RESULTS As the BTC distance increased, the uniformity reduced at 3% per millimetre. The HIR value indicated that the bladder signal is most sensitive to the change in BTC distance. By maintaining a constant BTC distance set-up, the intensity uniformity was improved by 28% along the B0 directions. CONCLUSION Positioning the MRI coil on mounts can reduce body deformation but adversely degrades the image quality. The magnitude of this effect has been quantified for prostate MR simulation scanning. The coil needs to be positioned not only with a minimal but also uniform BTC distance in order to maximize image quality. ADVANCES IN KNOWLEDGE A method to characterize the effect on image quality due to the use of coil mounts was demonstrated. Coil mounts whose height can be adjusted individually to keep BTC distance constant are necessary to maintain a uniform image across the entire field of view.


Journal of Applied Clinical Medical Physics | 2015

Investigation on the performance of dedicated radiotherapy positioning devices for MR scanning for prostate planning

Jidi Sun; Jason Dowling; Peter Pichler; Joel Parker; Jarad Martin; Peter Stanwell; Jameen Arm; F. W. Menk; Peter B. Greer

The purpose of this study was to investigate performance of the couch and coil mounts designed for MR‐simulation prostate scanning using data from ten volunteers. Volunteers were scanned using the standard MR scanning protocol with the MR coil directly strapped on the external body and the volunteer lying on the original scanner table. They also were scanned using a MR‐simulation table top and pelvic coil mounts. MR images from both setups were compared in terms of body contour variation and image quality effects within particular organs of interest. Six‐field conformal plans were generated on the two images with assigned bulk density for dose calculation. With the MR‐simulation devices, the anterior skin deformation was reduced by up to 1.7 cm. The hard tabletop minimizes the posterior body deformation which can be up to 2.3 cm on the standard table, depending on the weight of volunteer. The image signal‐to‐noise ratio reduced by 14% and 25% on large field of view (FOV) and small FOV images, respectively, after using the coil mount; the prostate volume contoured on two images showed difference of 1.05±0.66 cm3. The external body deformation caused a mean dose reduction of 0.6±0.3 Gy, while the coverage reduced by 22%±13% and 27%±6% in V98 and V100, respectively. A dedicated MR simulation setup for prostate radiotherapy is essential to ensure the agreement between planning anatomy and treatment anatomy. The image signal was reduced after applying the coil mount, but no significant effect was found on prostate contouring. PACS numbers: 87.55.D‐, 87.61.‐c, 87.57.C‐


Medical Physics | 2014

SU-E-J-29: Audiovisual Biofeedback Improves Tumor Motion Consistency for Lung Cancer Patients

Danny Lee; Peter B. Greer; Jameen Arm; Perry Hunter; Sean Pollock; Kuldeep Makhija; Taeho Kim; P Keall

PURPOSE To investigate whether the breathing-guidance system: audiovisual (AV) biofeedback improves tumor motion consistency for lung cancer patients. This will minimize respiratory-induced tumor motion variations across cancer imaging and radiotherapy procedues. This is the first study to investigate the impact of respiratory guidance on tumor motion. METHODS Tumor motion consistency was investigated with five lung cancer patients (age: 55 to 64), who underwent a training session to get familiarized with AV biofeedback, followed by two MRI sessions across different dates (pre and mid treatment). During the training session in a CT room, two patient specific breathing patterns were obtained before (Breathing-Pattern-1) and after (Breathing-Pattern-2) training with AV biofeedback. In each MRI session, four MRI scans were performed to obtain 2D coronal and sagittal image datasets in free breathing (FB), and with AV biofeedback utilizing Breathing-Pattern-2. Image pixel values of 2D images after the normalization of 2D images per dataset and Gaussian filter per image were used to extract tumor motion using image pixel values. The tumor motion consistency of the superior-inferior (SI) direction was evaluated in terms of an average tumor motion range and period. RESULTS Audiovisual biofeedback improved tumor motion consistency by 60% (p value = 0.019) from 1.0±0.6 mm (FB) to 0.4±0.4 mm (AV) in SI motion range, and by 86% (p value < 0.001) from 0.7±0.6 s (FB) to 0.1±0.2 s (AV) in period. CONCLUSION This study demonstrated that audiovisual biofeedback improves both breathing pattern and tumor motion consistency for lung cancer patients. These results suggest that AV biofeedback has the potential for facilitating reproducible tumor motion towards achieving more accurate medical imaging and radiation therapy procedures.


Journal of Magnetic Resonance Imaging | 2018

Reliability of neurometabolite detection with two-dimensional localized correlation spectroscopy at 3T: Neurometabolite Detection With 2D L-COSY at 3T

Jameen Arm; Oun Al-iedani; Scott Quadrelli; Karen Ribbons; Rod A. Lea; Jeannette Lechner-Scott; Saadallah Ramadan

Two‐dimensional localized correlational spectroscopy (2D L‐COSY) has been applied in vivo to investigate metabolic profiles in many disorders due to its ability to detect several metabolites simultaneously. Successful application of this technique depends on the reliability of the detection and understanding of the variability result from test–retest measurements.


European Journal of Radiology | 2018

Diurnal stability and long-term repeatability of neurometabolites using single voxel 1H magnetic resonance spectroscopy

Oun Al-iedani; Jameen Arm; Karen Ribbons; Rodney Arthur Lea; Jeannette Lechner-Scott; Saadallah Ramadan

PURPOSE This study was designed to evaluate the diurnal stability and long-term repeatability and reliability of one-dimensional (1D) hydrogen magnetic resonance spectroscopy (1H-MRS) in vitro and in vivo at 3 T. MATERIAL AND METHOD A standard brain phantom was used for in vitro study. In vivo diurnal evaluation involved ten healthy subjects, while repeatability study involved six subjects. MRS was acquired from posterior cingulate gyrus (PCG), and processed with LCModel. Diurnal effects were assessed with repeated measures ANOVAs, repeatability was evaluated using coefficient of variation (CV), while reliability was assessed with standard error measurement (SEM) and intra-class correlation coefficient (ICC). RESULTS Diurnal metabolic changes in vitro were non-significant. The intra/inter-in vitro CVs for the major metabolites; N-acetylaspartate (NAA), creatine (Cr), myo-inositol (mI), glutamate + glutamine (Glx) and total choline (tCho) were 1-3%/2-6%, respectively. Statistically significant in vivo diurnal effects were only seen for glycerophosphocholine (GPC, +10%, F = 10.6, p = 0.001) and Glx (+6%, F = 5.1, p = 0.018). The intra/inter-subject CVs for the major metabolites ranged from 2-5%/ 5-9%, respectively. The major metabolites displayed ICC ranging from 0.5-0.7 and low SEM (0.001-0.078) reflecting high reliability in detecting neurometabolites. The inter-week interval for in vivo measurements had minimal effect on metabolite ratios (F = 1.4, p = 0.09). CONCLUSION In vitro MRS showed no diurnal effects and minimal variation in metabolite levels. Most PCG metabolites are not altered diurnally. The low in vivo variability of metabolite concentration supports the use of localised MRS on clinical 3 T scanners for reliable neurometabolic profiling of the brain.


Advances in radiation oncology | 2017

Audiovisual biofeedback guided breath-hold improves lung tumor position reproducibility and volume consistency

Danny Lee; Peter B. Greer; Carminia Lapuz; Joanna Ludbrook; Perry Hunter; Jameen Arm; Sean Pollock; Kuldeep Makhija; R. O'Brien; Taeho Kim; P Keall

Purpose Respiratory variation can increase the variability of tumor position and volume, accounting for larger treatment margins and longer treatment times. Audiovisual biofeedback as a breath-hold technique could be used to improve the reproducibility of lung tumor positions at inhalation and exhalation for the radiation therapy of mobile lung tumors. This study aimed to assess the impact of audiovisual biofeedback breath-hold (AVBH) on interfraction lung tumor position reproducibility and volume consistency for respiratory-gated lung cancer radiation therapy. Methods Lung tumor position and volume were investigated in 9 patients with lung cancer who underwent a breath-hold training session with AVBH before 2 magnetic resonance imaging (MRI) sessions. During the first MRI session (before treatment), inhalation and exhalation breath-hold 3-dimensional MRI scans with conventional breath-hold (CBH) using audio instructions alone and AVBH were acquired. The second MRI session (midtreatment) was repeated within 6 weeks after the first session. Gross tumor volumes (GTVs) were contoured on each dataset. CBH and AVBH were compared in terms of tumor position reproducibility as assessed by GTV centroid position and position range (defined as the distance of GTV centroid position between inhalation and exhalation) and tumor volume consistency as assessed by GTV between inhalation and exhalation. Results Compared with CBH, AVBH improved the reproducibility of interfraction GTV centroid position by 46% (P = .009) from 8.8 mm to 4.8 mm and GTV position range by 69% (P = .052) from 7.4 mm to 2.3 mm. Compared with CBH, AVBH also improved the consistency of intrafraction GTVs by 70% (P = .023) from 7.8 cm3 to 2.5 cm3. Conclusions This study demonstrated that audiovisual biofeedback can be used to improve the reproducibility and consistency of breath-hold lung tumor position and volume, respectively. These results may provide a pathway to achieve more accurate lung cancer radiation treatment in addition to improving various medical imaging and treatments by using breath-hold procedures.

Collaboration


Dive into the Jameen Arm's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar

Saadallah Ramadan

Brigham and Women's Hospital

View shared research outputs
Top Co-Authors

Avatar

Jarad Martin

University of Newcastle

View shared research outputs
Top Co-Authors

Avatar

Jason Dowling

Commonwealth Scientific and Industrial Research Organisation

View shared research outputs
Top Co-Authors

Avatar

Jidi Sun

University of Newcastle

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Carolyn E. Mountford

Brigham and Women's Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

F. W. Menk

University of Newcastle

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge