Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where James Chang is active.

Publication


Featured researches published by James Chang.


Journal of Agricultural and Food Chemistry | 2012

Application of ultrahigh-performance liquid chromatography and electrospray ionization quadrupole orbitrap high-resolution mass spectrometry for determination of 166 pesticides in fruits and vegetables.

Jian Wang; Willis Chow; Daniel Leung; James Chang

This paper presents an application of ultrahigh-performance liquid chromatography and electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap) for determination of 166 pesticide residues in fruits and vegetables. Pesticides were extracted from the samples using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure. UHPLC/ESI Q-Orbitrap MS (i.e., full MS scan) acquired full MS data for quantification, and UHPLC/ESI Q-Orbitrap dd-MS(2) (i.e., data-dependent scan) obtained product-ion spectra for confirmation. UHPLC/ESI Q-Orbitrap MS quantification was achieved using matrix-matched standard calibration curves with isotopically labeled standards or chemical analogues as internal standards. The method performance characteristics that included overall recovery, intermediate precision, and measurement uncertainty were evaluated according to a nested experimental design. For the matrices studied, about 90.3-91.5% of the pesticides had recoveries between 81 and 110%, 92.1-97.6% had intermediate precision ≤20%, and 89.7-95.2% had measurement uncertainty ≤40%. Confirmation was based on mass accuracy ≤5 ppm and LC retention time tolerance within ±2.5%. Overall, the UHPLC/ESI Q-Orbitrap has demonstrated great performance for quantification and confirmation of pesticide residues in fresh fruits and vegetables.


Journal of Chromatography A | 2014

High-throughput screening of pesticide and veterinary drug residues in baby food by liquid chromatography coupled to quadrupole Orbitrap mass spectrometry

Wei Jia; Xiaogang Chu; Yun Ling; Junrong Huang; James Chang

A new analytical method was developed and validated for simultaneous analysis of 333 pesticide and veterinary drug residues in baby food. Response surface methodology was employed to optimize a generic extraction method. Ultrahigh-performance liquid chromatography and electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC-ESI Q-Orbitrap) was used for the separation and detection of all the analytes. The method was validated by taking into consideration the guidelines specified in Commission Decision 2002/657/EC and SANCO/12571/2013. The extraction recoveries were in a range of 79.8-110.7%, with coefficient of variation <8.3%. The 333 compounds behave dynamic in the range 0.1-1000μgkg(-1) concentration, with correlation coefficient >0.99. The limits of detection for the analytes are in the range 0.01-5.35μgkg(-1). The limits of quantification for the analytes are in the range 0.01-9.27μgkg(-1). This method has been successfully applied on screening of pesticide and veterinary drugs in ninety-three commercial baby food samples, and tilmicosin, fenbendazole, tylosin tartrate and thiabendazole were detected in some samples tested in this study. The present study is very useful for fast screening of different food contaminants.


Journal of Agricultural and Food Chemistry | 2014

Ultrahigh-Performance Liquid Chromatography Electrospray Ionization Q-Orbitrap Mass Spectrometry for the Analysis of 451 Pesticide Residues in Fruits and Vegetables: Method Development and Validation

Jian Wang; Willis Chow; James Chang; Jon W. Wong

This paper presents an application of ultrahigh-performance liquid chromatography electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap MS) for the determination of 451 pesticide residues in fruits and vegetables. Pesticides were extracted from samples using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure. UHPLC/ESI Q-Orbitrap MS in full MS scan mode acquired full MS data for quantification, and UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) (i.e., data-dependent scan mode) obtained product ion spectra for identification. UHPLC/ESI Q-Orbitrap MS quantification was achieved using matrix-matched standard calibration curves along with the use of isotopically labeled standards or a chemical analogue as internal standards to achieve optimal method accuracy. The method performance characteristics include overall recovery, intermediate precision, and measurement uncertainty evaluated according to a nested experimental design. For the 10 matrices studied, 94.5% of the pesticides in fruits and 90.7% in vegetables had recoveries between 81 and 110%; 99.3% of the pesticides in fruits and 99.1% of the pesticides in vegetables had an intermediate precision of ≤20%; and 97.8% of the pesticides in fruits and 96.4% of the pesticides in vegetables showed measurement uncertainty of ≤50%. Overall, the UHPLC/ESI Q-Orbitrap MS demonstrated acceptable performance for the quantification of pesticide residues in fruits and vegetables. The UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) along with library matching showed great potential for identification and is being investigated further for routine practice.


Journal of Chromatography A | 2014

Multi-mycotoxin analysis in dairy products by liquid chromatography coupled to quadrupole orbitrap mass spectrometry.

Wei Jia; Xiaogang Chu; Yun Ling; Junrong Huang; James Chang

A new analytical method was developed and validated for simultaneous analysis of 58 mycotoxins in dairy products. Response surface methodology was employed to optimize a quick, easy, cheap, effective, rugged, and safe (QuEChERS) sample preparation method. Ultrahigh-performance liquid chromatography and electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap) was used for the separation and detection of all the analytes. The method was validated by taking into consideration the guidelines specified in Commission Decision 2002/657/EC and 401/2006/EC. The extraction recoveries were in a range of 86.6-113.7%, with coefficient of variation <6.2%. The 58 compounds could be detected in the 0.001-100 μg kg(-1) concentration range, with correlation coefficient >0.99. The limits of detection for the analytes are in the range 0.001-0.92 μg kg(-1). The repeatability was lower than 6.4%. This method has been successfully applied on screening of mycotoxins in commercial dairy product samples, and it is very useful for fast screening of different food contaminants.


Journal of Agricultural and Food Chemistry | 2015

Development and Validation of a Multiclass Method for Analysis of Veterinary Drug Residues in Milk Using Ultrahigh Performance Liquid Chromatography Electrospray Ionization Quadrupole Orbitrap Mass Spectrometry.

Jian Wang; Daniel Leung; Willis Chow; James Chang; Jon W. Wong

This paper presents the development and validation of a multiclass method for the analysis of veterinary drug residues in milk using ultrahigh performance liquid chromatography electrospray ionization quadrupole Orbitrap mass spectrometry (UHPLC/ESI Q-Orbitrap). The 12 classes of veterinary drugs (a total of 125) included in this study were endectocides, fluoroquinolones, ionophores, macrolides, nitroimidazole, NSAIDs, β-lactams, penicillins, phenicols, sulfonamides, tetracyclines, and aminoglycosides. Veterinary drug residues in milk were extracted using a modified salting-out supported liquid extraction (SOSLE) method, which entailed the precipitation of milk proteins using an extraction buffer (oxalic acid and EDTA, pH 3) and acetonitrile, a salting-out acetonitrile/water phase separation using ammonium sulfate, and solid-phase extraction (SPE) using polymeric reversed-phase sorbent cartridges. The final extracts were concentrated and reconstituted into a buffer solution and analyzed using UHPLC/ESI Q-Orbitrap mass spectrometry. The developed method was validated using a nested experimental design to evaluate the method performance characteristics, such as overall recovery, intermediate precision, and measurement uncertainty. The method was able to quantify or screen up to 105 veterinary drugs from 11 different classes, except aminoglycosides. The limits of quantification were as low as 1.0 μg/kg, with an analytical range from 1.0 to 100.0 μg/kg in milk.


Journal of Chromatography A | 2014

Analysis of phthalates in milk and milk products by liquid chromatography coupled to quadrupole Orbitrap high-resolution mass spectrometry

Wei Jia; Xiaogang Chu; Yun Ling; Junrong Huang; James Chang

A new analytical method was developed and validated for simultaneous analysis of 27 phthalates in milk and milk products. Response surface methodology was employed to optimize a quick, easy, cheap, effective, rugged, and safe (QuEChERS) sample preparation method. Ultrahigh-performance liquid chromatography and electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap) was used for the separation and detection of all the analytes. The method was validated by taking into consideration the guidelines specified in Commission Decision 2002/657/EC and 2007/19/EC. The extraction recoveries were in a range of 90.7% to 104.6%, with coefficient of variation <5.6%. The 27 compounds behave dynamic range in the 0.1-1000μgkg(-1) concentration, with correlation coefficient >0.99. The limits of detection for the analytes are in the range 0.32-2.6μgkg(-1). This method has been successfully applied on screening of phthalates in 96 commercial milk and milk product samples.


Journal of Agricultural and Food Chemistry | 2015

Effect of sample dilution on matrix effects in pesticide analysis of several matrices by liquid chromatography-high-resolution mass spectrometry.

Paul Yang; James Chang; Jon W. Wong; Kai Zhang; Alexander J. Krynitsky; Maciej Bromirski; Jian Wang

This study used two LC columns of different adsorbents and liquid chromatography-electrospray ionization-high-resolution mass spectrometry to study the relationship between matrix effects (ME), the LC separations, and elution patterns of pesticides and those of matrix components. Using calibration standards of 381 pesticides at three dilution levels of 1×, 1/10×, and 1/100×, 108 samples were prepared in solvent and five different sample matrices for the study. Results obtained from principal component analysis and slope ratios of calibration curves provided measurements of the ME and showed the 1/100× sample dilution could minimize suppression ME for most pesticides analyzed. Should a pesticide coeluting with matrix components have a peak intensity of 25 times or higher, the suppression for that pesticide would persist even at 1/100× dilution. The number of pesticides had enhancement ME increased with increasing dilution from 1× to 1/100×, with those early eluting, hydrophilic pesticides affected the most.


Journal of Chromatography A | 2014

Analysis of additives in dairy products by liquid chromatography coupled to quadrupole-orbitrap mass spectrometry.

Wei Jia; Yun Ling; Yuanhui Lin; James Chang; Xiaogang Chu

A new method combining QuEChERS with ultrahigh-performance liquid chromatography and electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap) was developed for the highly accurate and sensitive screening of 43 antioxidants, preservatives and synthetic sweeteners in dairy products. Response surface methodology was employed to optimize a quick, easy, cheap, effective, rugged, and safe (QuEChERS) sample preparation method for the determination of 42 different analytes in dairy products for the first time. After optimization, the maximum predicted recovery was 99.33% rate for aspartame under the optimized conditions of 10 mL acetionitrile, 1.52 g sodium acetate, 410 mg PSA and 404 mgC18. For the matrices studied, the recovery rates of the other 42 compounds ranged from 89.4% to 108.2%, with coefficient of variation <6.4%. UHPLC/ESI Q-Orbitrap Mass full scan mode acquired full MS data was used to identify and quantify additives, and data-dependent scan mode obtained fragment ion spectra for confirmation. The mass accuracy typically obtained is routinely better than 1.5ppm, and only need to calibrate once a week. The 43 compounds behave dynamic in the range 0.001-1000 μg kg(-1) concentration, with correlation coefficient >0.999. The limits of detection for the analytes are in the range 0.0001-3.6 μg kg(-1). This method has been successfully applied on screening of antioxidants, preservatives and synthetic sweeteners in commercial dairy product samples, and it is very useful for fast screening of different food additives.


Journal of Agricultural and Food Chemistry | 2015

Multi-mycotoxin Analysis of Finished Grain and Nut Products Using Ultrahigh-Performance Liquid Chromatography and Positive Electrospray Ionization–Quadrupole Orbital Ion Trap High-Resolution Mass Spectrometry

Chia-Ding Liao; Jon W. Wong; Kai Zhang; Paul Yang; James B. Wittenberg; Mary W. Trucksess; Douglas G. Hayward; Nathaniel S. Lee; James Chang

Ultrahigh-performance liquid chromatography using positive electrospray ionization and quadrupole orbital ion trap high-resolution mass spectrometry was evaluated for analyzing mycotoxins in finished cereal and nut products. Optimizing the orbital ion trap mass analyzer in full-scan mode using mycotoxin-fortified matrix extracts gave mass accuracies, δM, of < ± 2.0 ppm at 70,000 full width at half maximum (FWHM) mass resolution (RFWHM). The limits of quantitation were matrix- and mycotoxin-dependent, ranging from 0.02 to 11.6 μg/kg. Mean recoveries and standard deviations for mycotoxins from acetonitrile/water extraction at their relevant fortification levels were 91 ± 10, 94 ± 10, 98 ± 12, 91 ± 13, 99 ± 15, and 93 ± 17% for corn, rice, wheat, almond, peanut, and pistachio, respectively. Nineteen mycotoxins with concentrations ranging from 0.3 (aflatoxin B1 in peanut and almond) to 1175 μg/kg (fumonisin B1 in corn flour) were found in 35 of the 70 commercial grain and nut samples surveyed. Mycotoxins could be identified at δM < ± 5 ppm by identifying the precursor and product ions in full-scan MS and data-dependent MS/MS modes. This method demonstrates a new analytical approach for monitoring mycotoxins in finished grain and nut products.


Journal of Agricultural and Food Chemistry | 2017

Development and Validation of a Qualitative Method for Target Screening of 448 Pesticide Residues in Fruits and Vegetables Using UHPLC/ESI Q-Orbitrap Based on Data-Independent Acquisition and Compound Database

Jian Wang; Willis Chow; James Chang; Jon W. Wong

A semiautomated qualitative method for target screening of 448 pesticide residues in fruits and vegetables was developed and validated using ultrahigh-performance liquid chromatography coupled with electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap). The Q-Orbitrap Full MS/dd-MS2 (data dependent acquisition) was used to acquire product-ion spectra of individual pesticides to build a compound database or an MS library, while its Full MS/DIA (data independent acquisition) was utilized for sample data acquisition from fruit and vegetable matrices fortified with pesticides at 10 and 100 μg/kg for target screening purpose. Accurate mass, retention time and response threshold were three key parameters in a compound database that were used to detect incurred pesticide residues in samples. The concepts and practical aspects of in-spectrum mass correction or solvent background lock-mass correction, retention time alignment and response threshold adjustment are discussed while building a functional and working compound database for target screening. The validated target screening method is capable of screening at least 94% and 99% of 448 pesticides at 10 and 100 μg/kg, respectively, in fruits and vegetables without having to evaluate every compound manually during data processing, which significantly reduced the workload in routine practice.

Collaboration


Dive into the James Chang's collaboration.

Top Co-Authors

Avatar

Wei Jia

Shaanxi University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Xiaogang Chu

Shaanxi University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Jian Wang

Canadian Food Inspection Agency

View shared research outputs
Top Co-Authors

Avatar

Jon W. Wong

Center for Food Safety and Applied Nutrition

View shared research outputs
Top Co-Authors

Avatar

Willis Chow

Canadian Food Inspection Agency

View shared research outputs
Top Co-Authors

Avatar

Junrong Huang

Shaanxi University of Science and Technology

View shared research outputs
Top Co-Authors

Avatar

Daniel Leung

Canadian Food Inspection Agency

View shared research outputs
Top Co-Authors

Avatar

Kai Zhang

Center for Food Safety and Applied Nutrition

View shared research outputs
Top Co-Authors

Avatar

Paul Yang

University of California

View shared research outputs
Top Co-Authors

Avatar

Ying Chen

National Kaohsiung First University of Science and Technology

View shared research outputs
Researchain Logo
Decentralizing Knowledge