IEEE Transactions on Biomedical Engineering | 2009

A Robust Monte Carlo Model for the Extraction of Biological Absorption and Scattering In Vivo

Janelle E. Bender; Karthik Vishwanath; Laura Moore; J.Q. Brown; Vivide Tuan-Chyan Chang; Gregory M. Palmer; Nirmala Ramanujam

We have a toolbox to quantify tissue optical properties that is composed of specialized fiberoptic probes for UV-visible diffuse reflectance spectroscopy and a fast, scalable inverse Monte Carlo (MC) model. In this paper, we assess the robustness of the toolbox for quantifying physiologically relevant parameters from turbid tissue-like media. In particular, we consider the effects of using different instruments, fiberoptic probes, and instrument-specific settings for a wide range of optical properties. Additionally, we test the quantitative accuracy of the inverse MC model for extracting the biologically relevant parameters of hemoglobin saturation and total hemoglobin concentration. We also test the effect of double-absorber phantoms (hemoglobin and crocin to model the absorption of hemoglobin and beta carotene, respectively, in the breast) for a range of absorption and scattering properties. We include an assessment on which reference phantom serves as the best calibration standard to enable accurate extraction of the absorption and scattering properties of the target sample. We found the best reference-target phantom combinations to be ones with similar scattering levels. The results from these phantom studies provide a set of guidelines for extracting optical parameters from clinical studies.


Physics in Medicine and Biology | 2006

Introduction to neutron stimulated emission computed tomography

Carey E. Floyd; Janelle E. Bender; Amy C. Sharma; Anuj J. Kapadia; Jessie Q. Xia; Brian P. Harrawood; Georgia D. Tourassi; Joseph Y. Lo; Alexander S. Crowell; C.R. Howell

Neutron stimulated emission computed tomography (NSECT) is presented as a new technique for in vivo tomographic spectroscopic imaging. A full implementation of NSECT is intended to provide an elemental spectrum of the body or part of the body being interrogated at each voxel of a three-dimensional computed tomographic image. An external neutron beam illuminates the sample and some of these neutrons scatter inelastically, producing characteristic gamma emission from the scattering nuclei. These characteristic gamma rays are acquired by a gamma spectrometer and the emitting nucleus is identified by the emitted gamma energy. The neutron beam is scanned over the body in a geometry that allows for tomographic reconstruction. Tomographic images of each element in the spectrum can be reconstructed to represent the spatial distribution of elements within the sample. Here we offer proof of concept for the NSECT method, present the first single projection spectra acquired from multi-element phantoms, and discuss potential biomedical applications.


Journal of Biomedical Optics | 2005

Depth-sensitive reflectance measurements using obliquely oriented fiber probes

Adrien Wang; Janelle E. Bender; Joshua Pfefer; Urs Utzinger; Rebekah A. Drezek

Computer simulation is used to facilitate the design of fiber-probe geometries that enable enhanced detection of optical signals arising from specific tissue depths. Obtaining understanding of the relationship between fiber-probe design and tissue interrogation is critical when developing strategies for optical detection of epithelial precancers that originate at known depths from the tissue surface. The accuracy of spectroscopic diagnostics may be enhanced by discretely probing the optical properties of epithelium and underlying stroma, within which the morphological and biochemical features vary as a function of depth. While previous studies have investigated controlling tissue-probing depth for fluorescence-based modalities, in this study we focus on the detection of reflected light scattered by tissue. We investigate how the depth of optical interrogation may be controlled through combinations of collection angles, source-detector separations, and numerical apertures. We find that increasing the obliquity of collection fibers at a given source-detector separation can effectively enhance the detection of superficially scattered signals. Fiber numerical aperture provides additional depth selectivity; however, the perturbations in sampling depth achieved through this means are modest relative to the changes generated by modifying the angle of collection and source-detection separation.


Journal of Biomedical Optics | 2008

Cost-effective diffuse reflectance spectroscopy device for quantifying tissue absorption and scattering in vivo

Bing Yu; Justin Y. Lo; T. F. Kuech; Gregory M. Palmer; Janelle E. Bender; Nirmala Ramanujam

A hybrid optical device that uses a multimode fiber coupled to a tunable light source for illumination and a 2.4-mm photodiode for detection in contact with the tissue surface is developed as a first step toward our goal of developing a cost-effective, miniature spectral imaging device to map tissue optical properties in vivo. This device coupled with an inverse Monte Carlo model of reflectance is demonstrated to accurately quantify tissue absorption and scattering in tissue-like turbid synthetic phantoms with a wide range of optical properties. The overall errors for quantifying the absorption and scattering coefficients are 6.0+/-5.6 and 6.1+/-4.7%, respectively. Compared with fiber-based detection, having the detector right at the tissue surface can significantly improve light collection efficiency, thus reducing the requirement for sophisticated detectors with high sensitivity, and this design can be easily expanded into a quantitative spectral imaging system for mapping tissue optical properties in vivo.


IEEE Transactions on Nuclear Science | 2008

Neutron Stimulated Emission Computed Tomography for Diagnosis of Breast Cancer

Anuj J. Kapadia; Amy C. Sharma; Georgia D. Tourassi; Janelle E. Bender; C.R. Howell; Alexander S. Crowell; Matthew R. Kiser; Brian P. Harrawood; R.S. Pedroni; Carey E. Floyd

Neutron stimulated emission computed tomography (NSECT) is being developed as a non-invasive spectroscopic imaging technique to determine element concentrations in the human body. NSECT uses a beam of fast neutrons that scatter inelastically from atomic nuclei in tissue, causing them to emit characteristic gamma photons that are detected and identified using an energy-sensitive gamma detector. By measuring the energy and number of emitted gamma photons, the system can determine the elemental composition of the target tissue. Such determination is useful in detecting several disorders in the human body that are characterized by changes in element concentration, such as breast cancer. In this paper we describe our experimental implementation of a prototype NSECT system for the diagnosis of breast cancer and present experimental results from sensitivity studies using this prototype. Results are shown from three sets of samples: (a) excised breast tissue samples with unknown element concentrations, (b) a multi-element calibration sample used for sensitivity studies, and (c) a small-animal specimen, to demonstrate detection ability from in-vivo tissue. Preliminary results show that NSECT has the potential to detect elements in breast tissue. Several elements were identified common to both benign and malignant samples, which were confirmed through neutron activation analysis (NAA). Statistically significant differences were seen for peaks at energies corresponding to 37Cl, 56Fe, 58Ni, 59Co, 79Br and 87Rb. The spectrum from the small animal specimen showed the presence of 12C from tissue, from bone, and elements 39K, 27Al, 37Cl, 56Fe, 68Zn and 25Mg. Threshold sensitivity for the four elements analyzed was found to range from 0.3 grams to 1 gram, which is higher than the microgram sensitivity required for cancer detection. Patient dose levels from NSECT were found to be comparable to those of screening mammography.


Optics Express | 2009

A strategy for quantitative spectral imaging of tissue absorption and scattering using light emitting diodes and photodiodes.

Justin Y. Lo; Bing Yu; Henry L. Fu; Janelle E. Bender; Gregory M. Palmer; T. F. Kuech; Nirmala Ramanujam

A diffuse reflectance spectroscopy system was modified as a step towards miniaturization and spectral imaging of tissue absorption and scattering. The modified system uses a tunable source and an optical fiber for illumination and a photodiode in contact with tissue for detection. Compared to the previous system, it is smaller, less costly, and has comparable performance in extracting optical properties in tissue phantoms. Wavelength reduction simulations show the feasibility of replacing the source with LEDs to further decrease system size and cost. Simulated crosstalk analysis indicates that this evolving system can be multiplexed for spectral imaging in the future.


Optics Express | 2009

Noninvasive monitoring of tissue hemoglobin using UV-VIS diffuse reflectance spectroscopy: a pilot study.

Janelle E. Bender; Allan Bruce Shang; Eugene W. Moretti; Bing Yu; Lisa M. Richards; Nirmala Ramanujam

We conducted a pilot study on 10 patients undergoing general surgery to test the feasibility of diffuse reflectance spectroscopy in the visible wavelength range as a noninvasive monitoring tool for blood loss during surgery. Ratios of raw diffuse reflectance at wavelength pairs were tested as a first-pass for estimating hemoglobin concentration. Ratios can be calculated easily and rapidly with limited post-processing, and so this can be considered a near real-time monitoring device. We found the best hemoglobin correlations were when ratios at isosbestic points of oxy- and deoxyhemoglobin were used, specifically 529/500 nm. Baseline subtraction improved correlations, specifically at 520/509 nm. These results demonstrate proof-of-concept for the ability of this noninvasive device to monitor hemoglobin concentration changes due to surgical blood loss. The 529/500 nm ratio also appears to account for variations in probe pressure, as determined from measurements on two volunteers.


Medical Physics | 2007

Breast cancer detection using neutron stimulated emission computed tomography: prominent elements and dose requirements.

Janelle E. Bender; Anuj J. Kapadia; Amy C. Sharma; Georgia D. Tourassi; Brian P. Harrawood; Carey E. Floyd

Neutron stimulated emission computed tomography (NSECT) is being developed to noninvasively determine concentrations of trace elements in biological tissue. Studies have shown prominent differences in the trace element concentration of normal and malignant breast tissue. NSECT has the potential to detect these differences and diagnose malignancy with high accuracy with dose comparable to that of a single mammogram. In this study, NSECT imaging was simulated for normal and malignant human breast tissue samples to determine the significance of individual elements in determining malignancy. The normal and malignant models were designed with different elemental compositions, and each was scanned spectroscopically using a simulated 2.5 MeV neutron beam. The number of incident neutrons was varied from 0.5 million to 10 million neutrons. The resulting gamma spectra were evaluated through receiver operating characteristic (ROC) analysis to determine which trace elements were prominent enough to be considered markers for breast cancer detection. Four elemental isotopes (133Cs, 81Br, 79Br, and 87Rb) at five energy levels were shown to be promising features for breast cancer detection with an area under the ROC curve (A(Z)) above 0.85. One of these elements--87Rb at 1338 keV--achieved perfect classification at 10 million incident neutrons and could be detected with as low as 3 million incident neutrons. Patient dose was calculated for each gamma spectrum obtained and was found to range from between 0.05 and 0.112 mSv depending on the number of neutrons. This simulation demonstrates that NSECT has the potential to noninvasively detect breast cancer through five prominent trace element energy levels, at dose levels comparable to other breast cancer screening techniques.


Journal of Biomedical Optics | 2010

Preferential accumulation of 5-aminolevulinic acid-induced protoporphyrin IX in breast cancer: a comprehensive study on six breast cell lines with varying phenotypes

Stacy R. Millon; Julie H. Ostrander; Siavash Yazdanfar; J. Quincy Brown; Janelle E. Bender; Anita Rajeha; Nirmala Ramanujam

We describe the potential of 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence as a source of contrast for margin detection in commonly diagnosed breast cancer subtypes. Fluorescence intensity of PpIX in untreated and ALA-treated normal mammary epithelial and breast cancer cell lines of varying estrogen receptor expression were quantitatively imaged with confocal microscopy. Percentage change in fluorescence intensity integrated over 610-700 nm (attributed to PpIX) of posttreated compared to pretreated cells showed statistically significant differences between four breast cancer and two normal mammary epithelial cell lines. However, a direct comparison of post-treatment PpIX fluorescence intensities showed no differences between breast cancer and normal mammary epithelial cell lines due to confounding effects by endogenous fluorescence from flavin adenine dinucleotide (FAD). Clinically, it is impractical to obtain pre- and post-treatment images. Thus, spectral imaging was demonstrated as a means to remove the effects of endogenous FAD fluorescence allowing for discrimination between post-treatment PpIX fluorescence of four breast cancer and two normal mammary epithelial cell lines. Fluorescence spectral imaging of ALA-treated breast cancer cells showed preferential PpIX accumulation regardless of malignant phenotype and suggests a useful contrast mechanism for discrimination of residual cancer at the surface of breast tumor margins.


Optics Letters | 2008

Diffuse reflectance spectroscopy with a self-calibrating fiber optic probe

Bing Yu; Henry Fu; Torre M. Bydlon; Janelle E. Bender; Nirmala Ramanujam

Calibration of the diffuse reflectance spectrum for instrument response and time-dependent fluctuation as well as interdevice variations is complicated, time consuming, and potentially inaccurate. We describe a novel fiber optic probe with a real-time self-calibration capability that can be used for tissue optical spectroscopy. The probe was tested in a number of liquid phantoms over a relevant range of tissue optical properties. Absorption and scattering coefficients are extracted with an average absolute error and standard deviation of 6.9%+/-7.2% and 3.5%+/-1.5%, respectively.

Collaboration


Dive into the Janelle E. Bender's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge