Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jansen Seheult is active.

Publication


Featured researches published by Jansen Seheult.


American Journal of Respiratory and Critical Care Medicine | 2017

Objective Assessment of Adherence to Inhalers by COPD Patients.

Imran Sulaiman; Breda Cushen; Garrett Greene; Jansen Seheult; Dexter Seow; Fiona Rawat; Elaine MacHale; Matshediso Mokoka; Catherine Moran; Aoife Sartini Bhreathnach; Philippa MacHale; Shahed Tappuni; Brenda Deering; Mandy Jackson; Hannah McCarthy; Lisa Mellon; Frank Doyle; Fiona Boland; Richard B. Reilly; Richard W. Costello

Rationale: Objective adherence to inhaled therapy by patients with chronic obstructive pulmonary disease (COPD) has not been reported. Objectives: To objectively quantify adherence to preventer Diskus inhaler therapy by patients with COPD with an electronic audio recording device (INCA). Methods: This was a prospective observational study. On discharge from hospital patients were given a salmeterol/fluticasone inhaler with an INCA device attached. Analysis of this audio quantified the frequency and proficiency of inhaler use. Measurements and Main Results: Patients with COPD (n = 244) were recruited. The mean age was 71 years, mean FEV1 was 1.3 L, and 59% had evidence of mild/moderate cognitive impairment. By combining time of use, interval between doses, and critical technique errors, thus incorporating both intentional and unintentional nonadherence, a measure “actual adherence” was calculated. Mean actual adherence was 22.6% of that expected if the doses were taken correctly and on time. Six percent had an actual adherence greater than 80%. Hierarchical clustering found three equally sized well‐separated clusters corresponding to distinct patterns. Cluster 1 (34%) had low inhaler use and high error rates. Cluster 2 (25%) had high inhaler use and high error rates. Cluster 3 (36%) had overall good adherence. Poor lung function and comorbidities were predictive of poor technique, whereas age and cognition with poor lung function distinguished those with poor adherence and frequent errors in technique. Conclusions: These data may inform clinicians in understanding why a prescribed inhaler is not effective and to devise strategies to promote adherence in COPD.


PLOS ONE | 2014

A Method to Assess Adherence in Inhaler Use through Analysis of Acoustic Recordings of Inhaler Events

Shona D'Arcy; Elaine MacHale; Jansen Seheult; Martin S. Holmes; Cian Hughes; Imran Sulaiman; Deirdre Hyland; Conor O'Reilly; Senan Glynn; Thekra Al-Zaabi; John McCourt; Terence E. Taylor; Frank Keane; Isabelle Killane; Richard B. Reilly; Richard W. Costello

Rationale Poor adherence to inhaler use can be due to poor temporal and/or technique adherence. Up until now there has been no way of reliably tracking both these factors in everyday inhaler use. Objectives This paper introduces a device developed to create time stamped acoustic recordings of an individuals inhaler use, in which empirical evidence of temporal and technique adherence in inhaler use can be monitored over time. The correlation between clinical outcomes and adherence, as determined by this device, was compared for temporal adherence alone and combined temporal and technique adherence. Findings The technology was validated by showing that the doses taken matched the number of audio recordings (r2 = 0.94, p<0.01). To demonstrate that audio analysis of inhaler use gives objective information, in vitro studies were performed. These showed that acoustic profiles of inhalations correlated with the peak inspiratory flow rate (r2 = 0.97, p<0.01), and that the acoustic energy of exhalations into the inhaler was related to the amount of drug removed. Despite training, 16% of participants exhaled into the mouthpiece after priming, in >20% of their inhaler events. Repeated training reduced this to 7% of participants (p = 0.03). When time of use was considered, there was no evidence of a relationship between adherence and changes in AQLQ (r2 = 0.2) or PEFR (r2 = 0.2). Combining time and technique the rate of adherence was related to changes in AQLQ (r2 = 0.53, p = 0.01) and PEFR (r2 = 0.29, p = 0.01). Conclusions This study presents a novel method to objectively assess how errors in both time and technique of inhaler use impact on clinical outcomes. Trial Registration EudraCT 2011-004149-42


Transfusion Medicine | 2017

Measurement of haemolysis markers following transfusion of uncrossmatched, low‐titer, group O+ whole blood in civilian trauma patients: initial experience at a level 1 trauma centre

Jansen Seheult; Darrell J. Triulzi; Louis H. Alarcon; Jason L. Sperry; Alan Murdock; Mark H. Yazer

The safety of administering uncrossmatched, group O, cold‐stored, whole blood (cWB) during civilian trauma resuscitation was evaluated.


SpringerPlus | 2014

Investigating the relationship between peak inspiratory flow rate and volume of inhalation from a Diskus™ Inhaler and baseline spirometric parameters: a cross-sectional study

Jansen Seheult; Simon Costello; Kee Chun Tee; Tariq Bholah; Hasan Al Bannai; Imran Sulaiman; Richard W. Costello

Drug delivery from a Dry Powder Inhaler (DPI) is dependent on the peak inspiratory flow rate (PIFR) generated. Currently available methods for estimating PIFR from most DPIs are limited and mainly rely on subjective assessment. We aim to show that spirometric and Diskus™ PIFR and Inspiratory Vital Capacity (IVC) are related to the underlying respiratory condition and that spirometric PIFR can be used to assess whether Diskus™ PIFR will be adequate when using this DPI. Healthy volunteers and patients with asthma, COPD, neuromuscular disease and non-respiratory disorders were recruited (n = 85). Demographics and baseline lung function by spirometry were recorded. Flow and volume readings were taken while patients used a Diskus™ DPI, housed in an airtight container connected to a spirometer. T-tests were performed to compare mean spirometric and Diskus™ PIFR/ IVC between groups. Stepwise regression analysis of Diskus™ PIFR versus spirometric PIFR, spirometric IVC, age, gender, condition, BMI, FEV1 and FVC was performed.The Diskus™ PIFR for the COPD and Neuromuscular Disease group was more than 10 L/min lower than the Healthy or Asthma groups (p < 0.05). The mean spirometric and Diskus™ IVC of the Healthy group was significantly (>0.75 L) higher than the mean for the other three groups (p < 0.05). Diskus™ PIFR was moderately correlated with spirometric PIFR and age (Adjusted R2 = 0.58, p < 0.0001). PIFR generated using a Diskus™ DPI is dependent on the underlying disease and age. A spirometric PIFR of less than 196 L/min should prompt further investigation into the suitability of a patient for a Diskus™ DPI, with possible consideration of alternate devices.


Journal of Aerosol Medicine and Pulmonary Drug Delivery | 2014

An Acoustic-Based Method to Detect and Quantify the Effect of Exhalation into a Dry Powder Inhaler.

Martin S. Holmes; Jansen Seheult; Peter O'Connell; Shona D'Arcy; Carsten Ehrhardt; Anne Marie Healy; Richard W. Costello; Richard B. Reilly

BACKGROUND Dry powder inhaler (DPI) users frequently exhale into their inhaler mouthpiece before the inhalation step. This error in technique compromises the integrity of the drug and results in poor bronchodilation. This study investigated the effect of four exhalation factors (exhalation flow rate, distance from mouth to inhaler, exhalation duration, and relative air humidity) on dry powder dose delivery. Given that acoustic energy can be related to the factors associated with exhalation sounds, we then aimed to develop a method of identifying and quantifying this critical inhaler technique error using acoustic based methods. METHODS An in vitro test rig was developed to simulate this critical error. The effect of the four factors on subsequent drug delivery were investigated using multivariate regression models. In a further study we then used an acoustic monitoring device to unobtrusively record the sounds 22 asthmatic patients made whilst using a Diskus(™) DPI. Acoustic energy was employed to automatically detect and analyze exhalation events in the audio files. RESULTS All exhalation factors had a statistically significant effect on drug delivery (p<0.05); distance from the inhaler mouthpiece had the largest effect size. Humid air exhalations were found to reduce the fine particle fraction (FPF) compared to dry air. In a dataset of 110 audio files from 22 asthmatic patients, the acoustic method detected exhalations with an accuracy of 89.1%. We were able to classify exhalations occurring 5 cm or less in the direction of the inhaler mouthpiece or recording device with a sensitivity of 72.2% and specificity of 85.7%. CONCLUSIONS Exhaling into a DPI has a significant detrimental effect. Acoustic based methods can be employed to objectively detect and analyze exhalations during inhaler use, thus providing a method of remotely monitoring inhaler technique and providing personalized inhaler technique feedback.


European Respiratory Journal | 2018

A randomised clinical trial of feedback on inhaler adherence and technique in patients with severe uncontrolled asthma

Imran Sulaiman; Garrett Greene; Elaine MacHale; Jansen Seheult; Matshediso Mokoka; Shona D'Arcy; Terence E. Taylor; Desmond M. Murphy; Eoin Hunt; Stephen J. Lane; Gregory B. Diette; J. Mark FitzGerald; Fiona Boland; Aoife Sartini Bhreathnach; Breda Cushen; Richard B. Reilly; Frank Doyle; Richard W. Costello

In severe asthma, poor control could reflect issues of medication adherence or inhaler technique, or that the condition is refractory. This study aimed to determine if an intervention with (bio)feedback on the features of inhaler use would identify refractory asthma and enhance inhaler technique and adherence. Patients with severe uncontrolled asthma were subjected to a stratified-by-site random block design. The intensive education group received repeated training in inhaler use, adherence and disease management. The intervention group received the same intervention, enhanced by (bio)feedback-guided training. The primary outcome was rate of actual inhaler adherence. Secondary outcomes included a pre-defined assessment of clinical outcome. Outcome assessors were blinded to group allocation. Data were analysed on an intention-to-treat and per-protocol basis. The mean rate of adherence during the third month in the (bio)feedback group (n=111) was higher than that in the enhanced education group (intention-to-treat, n=107; 73% versus 63%; 95% CI 2.8%–17.6%; p=0.02). By the end of the study, asthma was either stable or improved in 54 patients (38%); uncontrolled, but poorly adherent in 52 (35%); and uncontrolled, but adherent in 40 (27%). Repeated feedback significantly improved inhaler adherence. After a programme of adherence and inhaler technique assessment, only 40 patients (27%) were refractory and adherent, and might therefore need add-on therapy. On a period of monitored adherence only 27% of patients were refractory and adherent and thus need add-on therapy http://ow.ly/ddQr30gTpmb


BMJ Open | 2016

A protocol for a randomised clinical trial of the effect of providing feedback on inhaler technique and adherence from an electronic device in patients with poorly controlled severe asthma

Imran Sulaiman; Elaine Mac Hale; Martin S. Holmes; Cian Hughes; Shona D'Arcy; Terrence Taylor; Viliam Rapcan; Frank Doyle; Aoife Breathnach; Jansen Seheult; Desmond M. Murphy; Eoin Hunt; Stephen J. Lane; Abhilash Sahadevan; Gloria Crispino; Greg Diette; Isabelle Killane; Richard B. Reilly; Richard W. Costello

Introduction In clinical practice, it is difficult to distinguish between patients with refractory asthma from those with poorly controlled asthma, where symptoms persist due to poor adherence, inadequate inhaler technique or comorbid diseases. We designed an audio recording device which, when attached to an inhaler, objectively identifies the time and technique of inhaler use, thereby assessing both aspects of adherence. This study will test the hypothesis that feedback on these two aspects of adherence when passed on to patients improves adherence and helps clinicians distinguish refractory from difficult-to-control asthma. Methods This is a single, blind, prospective, randomised, clinical trial performed at 5 research centres. Patients with partially controlled or uncontrolled severe asthma who have also had at least one severe asthma exacerbation in the prior year are eligible to participate. The effect of two types of nurse-delivered education interventions to promote adherence and inhaler technique will be assessed. The active group will receive feedback on their inhaler technique and adherence from the new device over a 3-month period. The control group will also receive training in inhaler technique and strategies to promote adherence, but no feedback from the device. The primary outcome is the difference in actual adherence, a measure that incorporates time and technique of inhaler use between groups at the end of the third month. Secondary outcomes include the number of patients who remain refractory despite good adherence, and differences in the components of adherence after the intervention. Data will be analysed on an intention-to-treat and a per-protocol basis. The sample size is 220 subjects (110 in each group), and loss to follow-up is estimated at 10% which will allow results to show a 10% difference (0.8 power) in adherence between group means with a type I error probability of 0.05. Trial registration number NCT01529697; Pre-results.


Clinical Chemistry and Laboratory Medicine | 2017

Lactic acidosis: an update

Jansen Seheult; Gerard Fitzpatrick; Gerard Boran

Abstract Lactate is one of the most crucial intermediates in carbohydrate and nonessential amino acid metabolism. The complexity of cellular interactions and metabolism means that lactate can be considered a waste product for one cell but a useful substrate for another. The presence of elevated lactate levels in critically ill patients has important implications for morbidity and mortality. In this review, we provide a brief outline of the metabolism of lactate, the pathophysiology of lactic acidosis, the clinical significance of D-lactate, the role of lactate measurement in acutely ill patients, the methods used to measure lactate in blood or plasma and some of the methodological issues related to interferences in these assays, especially in the case of ethylene glycol poisoning.


international conference of the ieee engineering in medicine and biology society | 2013

Using acoustics to estimate inspiratory flow rate and drug removed from a dry powder inhaler

Martin S. Holmes; Jansen Seheult; Colm Geraghty; Shona D'Arcy; Richard W. Costello; Richard B. Reilly

Morbidity and mortality rates of chronic respiratory diseases such as asthma and chronic obstructive pulmonary disease (COPD) are rising. There is a strong requirement for more effective management of these chronic diseases. Dry powder inhalers (DPIs) are one kind of devices currently employed to deliver medication aimed at controlling asthma and COPD symptoms. Despite their proven effectiveness when used correctly, some patients are unable to reach the inspiratory flow rate required to remove medication from the breath actuated devices and as a result, the medication does not reach the airways. This study employs an acoustic recording device, attached to a common DPI to record the audio signals of simulated inhalations. A rotameter was used to measure the flow rate through the inhaler while a milligram weighing scale was used to measure the amount of drug removed from each simulated inhalation. It was found that a strong correlation existed (R2>0.96) when average power, median amplitude, root mean square and mean absolute deviation were used to predict peak inspiratory flow rate. At a flow of 30L/Min (mean absolute deviation=0.0049), it was found that 77% of the total emitted dose was removed from the inhaler. Results indicate that acoustic measurements may be used in the prediction of inspiratory flow rate and quantity of medication removed from an inhaler.


Transfusion | 2018

Who's afraid of incompatible plasma? A balanced approach to the safe transfusion of blood products containing ABO-incompatible plasma: INCOMPATIBLE PLASMA TRANSFUSION

Mark H. Yazer; Jansen Seheult; Steven H. Kleinman; Steven R. Sloan; Philip C. Spinella

S ince the early 1950s, blood banks and transfusion services have sought to identify a titer threshold for the labeling of blood components containing potentially ABO-incompatible plasma as low risk and thus less likely to cause hemolysis. Some transfusion services have shied away from ABO-incompatible plasma transfusion altogether citing the small and difficult-to-quantify risk of an acute hemolytic transfusion reaction (HTR) or other uncommon adverse events. There are, however, three main situations where ABOincompatible plasma is issued by today’s blood banks. First, inventory limitations have made transfusion of platelet (PLT) concentrates across ABO barriers a very common practice in the United States with up to 40% of PLT transfusions being ABO incompatible with the recipient. Second, the shortage of AB donors and increasing use of plasma in trauma resuscitation protocols has led to increased utilization of group A plasma for trauma patients of unknown ABO group. Third, building on the successful military experience, there has been renewed interest in cold-stored group O whole blood (WB) as the first blood component to use during civilian trauma resuscitation. In addition, other potential sources of incompatible plasma include large-volume cryoprecipitate transfusions and use of CPDA-1 RBCs that contain significant quantities of plasma. This commentary explores the evidence on the safety of transfusing blood components containing ABO-incompatible plasma and reviews the strategies available to mitigate the small risk of hemolysis associated with ABO-incompatible plasma transfusions in the absence of a consensus definition for a low-titer plasma-containing product.

Collaboration


Dive into the Jansen Seheult's collaboration.

Top Co-Authors

Avatar

Richard W. Costello

Royal College of Surgeons in Ireland

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Imran Sulaiman

Royal College of Surgeons in Ireland

View shared research outputs
Top Co-Authors

Avatar

Elaine MacHale

Royal College of Surgeons in Ireland

View shared research outputs
Top Co-Authors

Avatar

Mark H. Yazer

University of Pittsburgh

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Breda Cushen

Royal College of Surgeons in Ireland

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Fiona Boland

Royal College of Surgeons in Ireland

View shared research outputs
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge