Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Javier A. Jo is active.

Publication


Featured researches published by Javier A. Jo.


Review of Scientific Instruments | 2004

Time-domain laser-induced fluorescence spectroscopy apparatus for clinical diagnostics

Qiyin Fang; Thanassis Papaioannou; Javier A. Jo; Russel Vaitha; Kumar Shastry; Laura Marcu

We report the design and development of a compact optical fiber-based apparatus for in situ time-resolved laser-induced fluorescence spectroscopy (tr-LIFS) of biological systems. The apparatus is modular, optically robust, and compatible with the clinical environment. It incorporates a dual output imaging spectrograph, a gated multichannel plate photomultiplier (MCP-PMT), an intensified charge-coupled-device (ICCD) camera, and a fast digitizer. It can accommodate various types of light sources and optical fiber probes for selective excitation and remote light delivery/collection as required by different applications. The apparatus allows direct recording of the entire fluorescence decay with high sensitivity (nM range fluorescein dye concentration with signal-to-noise ratio of 46) and with four decades dynamic range. It is capable of resolving a broad range of fluorescence lifetimes from hundreds of picoseconds (as low as 300 ps) using the MCP-PMT coupled to the digitizer to milliseconds using the ICCD. T...


Journal of Biomedical Optics | 2004

Fast model-free deconvolution of fluorescence decay for analysis of biological systems

Javier A. Jo; Qiyin Fang; Thanassis Papaioannou; Laura Marcu

For complex biological systems, conventional analysis of fluorescence intensity decay in terms of discrete exponential components cannot readily provide a true representation of the underlying fluorescence dynamics. We investigate an alternative nonparametric method for the analysis of time-resolved fluorescence data from biochemical and biological systems based on the expansion of fluorescence decay in a discrete Laguerre basis. We report that a unique Laguerre expansion can be found for fluorescence intensity decays of arbitrary form with convergence to a correct solution significantly faster than conventional multiexponential approximation methods. The Laguerre expansion coefficients are shown to be highly correlated with intrinsic fluorescence lifetimes and allow direct characterization of the fluorescence dynamics. A novel method for prediction of concentrations in mixtures of biochemical components using these coefficients is developed and successfully tested (prediction error <2%) using data from different mixtures of fluorescence lifetime standards. These findings suggest that the use of Laguerre expansion coefficients is a fast approach for the characterization and discrimination of complex biological systems such as tissues and cells, and that the method has potential for applications of fluorescence lifetime techniques to tissue diagnostics and imaging microscopy of living cells.


Photochemistry and Photobiology | 2004

Fluorescence Lifetime Spectroscopy of Glioblastoma Multiforme

Laura Marcu; Javier A. Jo; Pramod Butte; William H. Yong; Brian K. Pikul; Keith L. Black; Reid C. Thompson

Abstract Fluorescence spectroscopy of the endogenous emission of brain tumors has been researched as a potentially important method for the intraoperative localization of brain tumor margins. We investigated the use of time-resolved, laser-induced fluorescence spectroscopy for demarcation of primary brain tumors by studying the time-resolved spectra of gliomas. The fluorescence of human brain samples (glioblastoma multiforme, cortex and white matter: six patients, 23 sites) was induced ex vivo with a pulsed nitrogen laser (337 nm, 3 ns). The time-resolved spectra were detected in a 360–550 nm wavelength range using a fast digitizer and gated detection. Parameters derived from both the spectral- (intensities from narrow spectral bands) and the time domain (average lifetime) measured at 390 and 460 nm were used for tissue characterization. We determined that high-grade gliomas are characterized by fluorescence lifetimes that varied with the emission wavelength (>3 ns at 390 nm, <1 ns at 460 nm) and their emission is overall longer than that of normal brain tissue. Our study demonstrates that the use of fluorescence lifetime not only improves the specificity of fluorescence measurements but also allows a more robust evaluation of data collected from brain tissue. Combined information from both the spectral- and the time domain can enhance the ability of fluorescence-based techniques to diagnose and detect brain tumor margins intraoperatively.


Atherosclerosis | 2009

Detection of rupture-prone atherosclerotic plaques by time-resolved laser-induced fluorescence spectroscopy

Laura Marcu; Javier A. Jo; Qiyin Fang; Thanassis Papaioannou; Todd D. Reil; Jian Hua Qiao; J. Dennis Baker; Julie A. Freischlag; Michael C. Fishbein

OBJECTIVE Plaque with dense inflammatory cells, including macrophages, thin fibrous cap and superficial necrotic/lipid core is thought to be prone-to-rupture. We report a time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) technique for detection of such markers of plaque vulnerability in human plaques. METHODS The autofluorescence of carotid plaques (65 endarterectomy patients) induced by a pulsed laser (337 nm, 0.7 ns) was measured from 831 distinct areas. The emission was resolved spectrally (360-550 nm range) and temporally (0.3 ns resolution) using a prototype fiber-optic TR-LIFS apparatus. Lesions were evaluated microscopically and quantified as to the % of different components (fibrous cap, necrotic core, inflammatory cells, foam cells, mature and degraded collagen, elastic fibers, calcification, and smooth muscle cell of the vessel wall). RESULTS We determined that the spectral intensities and time-dependent parameters at discrete emission wavelengths (1) allow for discrimination (sensitivity >81%, specificity >94%) of various compositional and pathological features associated with plaque vulnerability including infiltration of macrophages into intima and necrotic/lipid core under a thin fibrous cap, and (2) show a linear correlation with plaque biochemical content: elastin (P<0.008), collagen (P<0.02), inflammatory cells (P<0.003), necrosis (P<0.004). CONCLUSION Our results demonstrate the feasibility of TR-LIFS as a method for the identification of markers of plaque vulnerability. Current findings enable future development of TR-LIFS-based clinical devices for rapid investigation of atherosclerotic plaques and detection of those at high-risk.


Biomedical Optics Express | 2014

Optical axial scanning in confocal microscopy using an electrically tunable lens

Joey M. Jabbour; Bilal H. Malik; Cory Olsovsky; Rodrigo Cuenca; Shuna Cheng; Javier A. Jo; Yi-Shing Lisa Cheng; John M. Wright; Kristen C. Maitland

This paper presents the use and characterization of an electrically focus tunable lens to perform axial scanning in a confocal microscope. Lateral and axial resolution are characterized over a >250 µm axial scan range. Confocal microscopy using optical axial scanning is demonstrated in epithelial tissue and compared to traditional stage scanning. By enabling rapid axial scanning, minimizing motion artifacts, and reducing mechanical complexity, this technique has potential to enhance in vivo three-dimensional imaging in confocal endomicroscopy.


Journal of Biomedical Optics | 2010

Intraoperative delineation of primary brain tumors using time-resolved fluorescence spectroscopy.

Pramod Butte; Qiyin Fang; Javier A. Jo; William H. Yong; Brian K. Pikul; Keith L. Black; Laura Marcu

The goal of this study is to determine the potential of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) as an adjunctive tool for delineation of brain tumor from surrounding normal tissue in order to assist the neurosurgeon in near-complete tumor excision. A time-domain TR-LIFS prototype apparatus (gated photomultiplier detection, fast digitizer) was used for recording tissue autofluorescence in normal cortex (NC), normal white matter (NWM), and various grades of gliomas intraoperatively. Tissue fluorescence was induced with a pulsed nitrogen laser (337 nm, 700 ps), and the intensity decay profiles were recorded in the 360- to 550-nm spectral range (10-nm interval). Histopathological analysis (hematoxylin & eosin) of the biopsy samples taken from the site of TR-LIFS measurements was used for validation of spectroscopic results. Preliminary results on 17 patients demonstrate that normal cortex (N=16) and normal white matter (N=3) show two peaks of fluorescence emission at 390 nm (lifetime=1.8+/-0.3 ns) and 460 nm (lifetime=0.8+/-0.1 ns). The 390-nm emission peak is absent in low-grade glioma (N=5; lifetime=1.1 ns) and reduced in high-grade glioma (N=9; lifetime=1.7+/-0.4 ns). The emission characteristics at 460 nm in all tissues correlated with the nicotinamide adenine dinucleotide fluorescence (peak: 440 to 460 nm; lifetime: 0.8 to 1.0 ns). These findings demonstrate the potential of using TR-LIFS as a tool for enhanced delineation of brain tumors during surgery. In addition, this study evaluates similarities and differences between TR-LIFS signatures of brain tumors obtained in vivo and those previously reported in ex vivo brain tumor specimens.


Biomedical Optics Express | 2010

A dual-modality optical coherence tomography and fluorescence lifetime imaging microscopy system for simultaneous morphological and biochemical tissue characterization

Jesung Park; Javier A. Jo; Sebina Shrestha; Paritosh Pande; Qiujie Wan; Brian E. Applegate

Most pathological conditions elicit changes in the tissue optical response that may be interrogated by one or more optical imaging modalities. Any single modality typically only furnishes an incomplete picture of the tissue optical response, hence an approach that integrates complementary optical imaging modalities is needed for a more comprehensive non-destructive and minimally-invasive tissue characterization. We have developed a dual-modality system, incorporating optical coherence tomography (OCT) and fluorescence lifetime imaging microscopy (FLIM), that is capable of simultaneously characterizing the 3-D tissue morphology and its biochemical composition. The Fourier domain OCT subsystem, at an 830 nm center wavelength, provided high-resolution morphological volumetric tissue images with an axial and lateral resolution of 7.3 and 13.4 µm, respectively. The multispectral FLIM subsystem, based on a direct pulse-recording approach (upon 355 nm laser excitation), provided two-dimensional superficial maps of the tissue autofluorescence intensity and lifetime at three customizable emission bands with 100 µm lateral resolution. Both subsystems share the same excitation/illumination optical path and are simultaneously raster scanned on the sample to generate coregistered OCT volumes and FLIM images. The developed OCT/FLIM system was capable of a maximum A-line rate of 59 KHz for OCT and a pixel rate of up to 30 KHz for FLIM. The dual-modality system was validated with standard fluorophore solutions and subsequently applied to the characterization of two biological tissue types: postmortem human coronary atherosclerotic plaques, and in vivo normal and cancerous hamster cheek pouch epithelial tissue.


Journal of Biomedical Optics | 2006

Laguerre-based method for analysis of time-resolved fluorescence data: application to in-vivo characterization and diagnosis of atherosclerotic lesions

Javier A. Jo; Qiyin Fang; Thanassis Papaioannou; J. Dennis Baker; Amir H. Dorafshar; Todd D. Reil; Jian Hua Qiao; Michael C. Fishbein; Julie A. Freischlag; Laura Marcu

We report the application of the Laguerre deconvolution technique (LDT) to the analysis of in-vivo time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data and the diagnosis of atherosclerotic plaques. TR-LIFS measurements were obtained in vivo from normal and atherosclerotic aortas (eight rabbits, 73 areas), and subsequently analyzed using LDT. Spectral and time-resolved features were used to develop four classification algorithms: linear discriminant analysis (LDA), stepwise LDA (SLDA), principal component analysis (PCA), and artificial neural network (ANN). Accurate deconvolution of TR-LIFS in-vivo measurements from normal and atherosclerotic arteries was provided by LDT. The derived Laguerre expansion coefficients reflected changes in the arterial biochemical composition, and provided a means to discriminate lesions rich in macrophages with high sensitivity (>85%) and specificity (>95%). Classification algorithms (SLDA and PCA) using a selected number of features with maximum discriminating power provided the best performance. This study demonstrates the potential of the LDT for in-vivo tissue diagnosis, and specifically for the detection of macrophages infiltration in atherosclerotic lesions, a key marker of plaque vulnerability.


New Journal of Physics | 2007

Miniaturized side-viewing imaging probe for fluorescence lifetime imaging (FLIM): validation with fluorescence dyes, tissue structural proteins and tissue specimens

Daniel S. Elson; Javier A. Jo; Laura Marcu

We report a side viewing fibre-based endoscope that is compatible with intravascular imaging and fluorescence lifetime imaging microscopy (FLIM). The instrument has been validated through testing with fluorescent dyes and collagen and elastin powders using the Laguerre expansion deconvolution technique to calculate the fluorescence lifetimes. The instrument has also been tested on freshly excised unstained animal vascular tissues.


Optics Letters | 2010

High-speed multispectral fluorescence lifetime imaging implementation for in vivo applications

Sebina Shrestha; Brian E. Applegate; Jesung Park; Xudong Xiao; Paritosh Pande; Javier A. Jo

Fluorescence lifetime imaging microscopy (FLIM) offers a noninvasive approach for characterizing the biochemical composition of biological tissue. In recent years, there has been an increasing interest in the application of multispectral FLIM for medical diagnosis. Central to the clinical translation of FLIM technology is the development of robust, fast, and cost-effective FLIM instrumentation suitable for in vivo tissue imaging. Unfortunately, the predominant multispectral FLIM approaches suffer from limitations that impede the development of high-speed instruments for in vivo applications. We present a cost-effective scanning multispectral FLIM implementation capable of achieving pixel rates on the order of tens of kilohertz, which will facilitate the evaluation of FLIM for in vivo applications.