Jeffrey P. Otjen
University of Washington
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Jeffrey P. Otjen.
Pediatric Radiology | 2013
Jeffrey P. Otjen; Charles A. Rohrmann; Ramesh S. Iyer
Foreign body ingestion is a common problem in the pediatric population and a frequent cause for emergency room visits. Magnets are common household objects that when ingested can bring about severe, possibly fatal gastrointestinal complications. Radiography is an integral component of the management of these children. Pediatric and emergency radiologists alike must be aware of imaging manifestations of magnet ingestion, as their identification drives decision-making for consulting surgeons and gastroenterologists. Radiology can thus substantially augment the clinical history and physical exam, facilitating appropriate management. This manuscript sequentially presents cases of magnet ingestion featuring imaging findings coupled with surgical and pathological correlation. Each case is presented to highlight ways in which the radiologist can make impactful contributions to diagnosis and management. Clinical overview with pitfalls of magnet ingestion imaging and an imaging decision tree will also be presented.
Pediatric Emergency Care | 2013
Julie C. Brown; Jeffrey P. Otjen; George T. Drugas
Background Small, powerful magnets are increasingly available in toys and other products and pose a health risk. Small spherical neodymium magnets marketed since 2008 are of particular concern. Objective The objective of this study was to determine the incidence, characteristics, and management of single and multiple-magnet ingestions over time. Methods Magnet ingestion cases at a tertiary children’s hospital were identified using radiology reports from June 2002 to December 2012. Cases were verified by chart and imaging review. Relative risk regressions were used to determine changes in the incidence of ingestions and interventions over time. Results Of 56 cases of magnet ingestion, 98% occurred in 2006 or later, and 57% involved multiple magnets. Median age was 8 years (range, 0–18 years). Overall, 21% of single and 88% of multiple ingestions had 2 or more imaging series obtained, whereas no single and 56.3% of multiple ingestions required intervention (25.0% endoscopy, 18.8% surgery, 12.5% both). Magnet ingestions increased in 2010 to 2012 compared with 2007 to 2009 (relative risk, 1.9; 95% confidence interval, 1.2–3.0). Small, spherical magnets likely from magnet sets comprised 27% of ingestions, all ingested 2010 or later: 86% involved multiple magnets, 50% of which required intervention. Excluding these cases, ingestions of other magnets did not increase in 2010 to 2012 compared with 2007 to 2009 (relative risk, 0.94; 95% confidence interval, 0.6–1.4). Conclusions The incidence of pediatric magnet ingestions and subsequent interventions has increased over time. Multiple-magnet ingestions result in high utilization of radiological imaging and surgical interventions. Recent increases parallel the increased availability of small, spherical magnet sets. Young and at-risk children should not have access to these and other small magnets. Improved regulation and magnet safety standards are needed.
Pediatric Radiology | 2015
Anh Vu Ngo; Jeffrey P. Otjen; Marguerite T. Parisi; Mark R. Ferguson; Randolph K. Otto; A. Luana Stanescu
Imaging is crucial in expediting the diagnosis and guiding definitive therapy in children with ovarian torsion. This article reviews the multimodality spectrum of imaging findings in pediatric ovarian torsion, focusing primarily on US appearances. We describe predisposing conditions that can lead to torsion, the pathological basis of the radiologic findings in ovarian torsion, and the common diagnostic pitfalls.
American Journal of Forensic Medicine and Pathology | 2012
Ben Buelow; Jeffrey P. Otjen; Annette P. Sabath; Richard C. Harruff
Liver rupture is a serious, life-threatening event that is commonly due to blunt abdominal trauma, which should be suspected in a patient who is unconscious or unable to communicate. We report an autopsy case of a 28-year-old woman with severe developmental delay who presented to the emergency department with hemoperitoneum due to massive liver rupture and subsequently died without a diagnosis. An autopsy performed by the hospital pathology department confirmed hemoperitoneum due to hepatic rupture. The case was then referred to the medical examiner to exclude a traumatic etiology. After review of the clinical data, radiological images, and gross and microscopic pathological features, a diagnosis of peliosis hepatis was established. This rare entity has been reported previously as a cause of spontaneous, nontraumatic liver rupture and is reported here to demonstrate its characteristic features and potential to present as fatal hepatic rupture in circumstances in which occult injury must be excluded.
Pediatric Radiology | 2015
Jeffrey P. Otjen; Shawn E. Parnell; Sarah J. Menashe; Mahesh M. Thapa
In children, MR arthrography is typically performed using fluoroscopic guidance. This article explores the role of US-guided joint injections as an alternative for MR arthrography in children, discussing its advantages and disadvantages compared to standard methods. We describe techniques for performing US-guided injection of the shoulder, elbow, hip, knee, ankle and posterior subtalar joints, highlighting pertinent anatomy, routes of access and unique considerations for this modality in children. Written descriptions, images and links to video clips are used to illustrate proper arthrographic technique. We conclude that US provides effective guidance for intra-articular injection prior to MR arthrography, with the advantages of improved visualization of internal structures, reduced radiation exposure, convenience of performing the procedure portably and ease of performance. Although this paper does not address therapeutic steroid injections, these techniques could easily be translated for such purposes. We propose US guidance as a viable alternative to fluoroscopic technique for arthrography in children.
Laryngoscope | 2014
Julie C. Brown; Fred M. Baik; Henry C. Ou; Jeffrey P. Otjen; Hannah G. Parish; Dylan K. Chan
Small, powerful magnets are increasingly available in toys and other products, and are responsible for increasing numbers of foreign body injuries in children. Small, spherical, neodymium magnets available since 2008 are of particular concern. We aimed to identify all cases of upper aerodigestive foreign bodies at our institution over 15.5 years of study.
Journal of The American College of Radiology | 2013
Ramesh S. Iyer; Jeffrey P. Otjen; Edward Weinberger
Quality assurance measures have been at the forefront of medicine in the past decade. Many of these initiatives were generated in response to the 2000 Institute of Medicine report To Err Is Human [1], which attributed nearly 100,000 annual deaths to preventable medical errors. Numerous specialties established committees to address such concerns, with the goal of providing safe and effective health care. TheACRtaskforceonsafetyandthe ImageGentlycampaignareexamples of such efforts within radiology. The use of checklists for quality assurance is not unique to medicine. They are widely used in manufacturing, finance, and human resources, among numerous other fields. The industry that has received greatest acclaim in the medical literature for its adherence to checklists is aviation. The pressure to reduce errors is magnified when dozens of lives are at stake with every takeoff. Larson and Nance [2] elegantly characterized the aviation industry’s approach to quality improvement. They contrasted the traditional method of quality improvement, identifying and removing poor individual performers, with the more modern method, which involves disseminating best practices to reduce errors at the system level. David Levin [3] recently
Journal of Magnetic Resonance Imaging | 2015
Jeffrey P. Otjen; Kara Mallon; Julie C. Brown
The use of magnets as a component of complementary and alternative medicine is increasingly common. Magnet therapy is used to treat a variety of conditions and often involves tiny magnets adhered to the skin. In auriculotherapy, magnets are placed in specific locations of the ear pinnae which represent particular parts of the body. While generally considered safe, these magnets have the potential to cause imaging problems and serious injury during MRI. We report a case of auriculotherapy magnets which escaped detection despite the use of screening forms and a walk‐through metal detector. The magnets caused image artifact but no other patient harm. We recommend updating patient screening practices and educating providers placing therapeutic magnets and performing MRIs of this new potential MRI hazard. J. Magn. Reson. Imaging 2015;41:858–860.
Journal of Clinical Ultrasound | 2015
Jeffrey P. Otjen; Luana A. Stanescu; Adam B. Goldin; Marguerite T. Parisi
The clinical and radiologic diagnosis of adnexal torsion is challenging. The patients history, physical examination, and laboratory evaluation may overlap significantly with other causes of abdominal pain. Ultrasound is the most common radiologic tool to assess for torsion, and the imaging findings can be equally equivocal. We present a case of adnexal torsion in an 18‐year‐old emergency room patient with abdominal pain, diagnosed by ultrasound based solely on an abnormal medial position of the ovary–a finding that has been only rarely mentioned in the literature, and never in isolation.
Current Problems in Diagnostic Radiology | 2018
Jeffrey P. Otjen; Jonathan O. Swanson; Assaf P. Oron; Robert M DiBlasi; Tim Swortzel; Jade Adriana Marie van Well; Eva Anna Elisabeth Gommers; Margaret Rosenfeld
BACKGROUND Image quality of high resolution chest computed tomographies (HRCTs) depends on adequate breath holds at end inspiration and end expiration. We hypothesized that implementation of spirometry-assisted breath holds in children undergoing HRCTs would improve image quality over that obtained with voluntary breath holds by decreasing motion artifact and atelectasis. METHODS This is a retrospective case-control study of HRCTs obtained at a tertiary care childrens hospital before and after implementation of a spirometry-assisted CT protocol, in which children ≥8 years of age are first trained in supine slow vital capacity maneuvers and then repeat the maneuvers in the CT scanner, coached by a respiratory therapist. Spirometry-assisted CT scans (cases) were matched by age, gender and diagnosis (cystic fibrosis vs other) to CT scans obtained with voluntary breath holds in the 6 years before implementation of the spirometry assistance protocol (controls), and evaluated by 2 blinded pediatric radiologists. RESULTS Among both cases and controls (N = 50 each), 10 carried the diagnosis of cystic fibrosis and 40 had other diagnoses. Mean age was 12.9 years (range: 7.5-20.1) among cases and 13.0 (7.1-19.7) among controls. Mean (SD) inspiratory image density among cases was -852 (37) Hounsfield units (HU) and -828 (43) among controls (p = 0.006). Mean (SD) expiratory image density was -629 (95) HU among cases and -688 (83) HU among controls (p = 0.002). Mean (SD) change in image density between inspiratory and expiratory images was +222 (85) HU among cases and +140 (76) HU among controls (p < 0.001). Motion artifact was present on inspiratory images in 5 cases and 9 controls (p = 0.39 by Fishers exact test), and on expiratory images in 20 cases and 18 controls (p > 0.80). Atelectasis was present on inspiratory images in 8 cases and 9 controls and on expiratory images in 9 cases and 10 controls (p > 0.80). CONCLUSIONS Spirometry-assisted CTs had a significantly greater difference in lung density between inspiratory and expiratory scans than those performed with voluntary breath holds, likely improving the ability to detect air trapping. No appreciable difference in image quality was detected for the presence of motion artifact or atelectasis.