Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jennifer M. Thomasen is active.

Publication


Featured researches published by Jennifer M. Thomasen.


Annals of Occupational Hygiene | 2009

Quantification and Statistical Modeling—Part I: Breathing-Zone Concentrations of Monomeric and Polymeric 1,6-Hexamethylene Diisocyanate

Kenneth W. Fent; Linda G. Trelles Gaines; Jennifer M. Thomasen; Sheila L. Flack; Kai Ding; Amy H. Herring; Stephen G. Whittaker; Leena A. Nylander-French

We conducted a repeated exposure-assessment survey for task-based breathing-zone concentrations (BZCs) of monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) during spray painting on 47 automotive spray painters from North Carolina and Washington State. We report here the use of linear mixed modeling to identify the primary determinants of the measured BZCs. Both one-stage (N = 98 paint tasks) and two-stage (N = 198 paint tasks) filter sampling was used to measure concentrations of HDI, uretidone, biuret, and isocyanurate. The geometric mean (GM) level of isocyanurate (1410 microg m(-3)) was higher than all other analytes (i.e. GM < 7.85 microg m(-3)). The mixed models were unique to each analyte and included factors such as analyte-specific paint concentration, airflow in the paint booth, and sampler type. The effect of sampler type was corroborated by side-by-side one- and two-stage personal air sampling (N = 16 paint tasks). According to paired t-tests, significantly higher concentrations of HDI (P = 0.0363) and isocyanurate (P = 0.0035) were measured using one-stage samplers. Marginal R(2) statistics were calculated for each model; significant fixed effects were able to describe 25, 52, 54, and 20% of the variability in BZCs of HDI, uretidone, biuret, and isocyanurate, respectively. Mixed models developed in this study characterize the processes governing individual polyisocyanate BZCs. In addition, the mixed models identify ways to reduce polyisocyanate BZCs and, hence, protect painters from potential adverse health effects.


Annals of Occupational Hygiene | 2009

Quantification and Statistical Modeling—Part II: Dermal Concentrations of Monomeric and Polymeric 1,6-Hexamethylene Diisocyanate

Kenneth W. Fent; Linda G. Trelles Gaines; Jennifer M. Thomasen; Sheila L. Flack; Kai Ding; Amy H. Herring; Stephen G. Whittaker; Leena A. Nylander-French

We conducted a quantitative dermal and inhalation exposure assessment of monomeric and polymeric 1,6-hexamethylene diisocyanates (HDI) in 47 automotive spray painters from North Carolina and Washington State. We report here the use of linear mixed modeling (LMM) to identify the primary determinants of dermal exposure. Dermal concentrations of HDI, uretidone, biuret, and isocyanurate were significantly higher in 15 painters who did not wear coveralls or gloves (N = 51 paint tasks) than in 32 painters who did wear coveralls and gloves (N = 192 paint tasks) during spray painting. Regardless of whether protective clothing was worn, isocyanurate was the predominant species measured in the skin [geometric mean (GM) = 33.8 ng mm(-3)], with a 95% detection rate. Other polyisocyanates (GM < or = 0.17 ng mm(-3)) were detected in skin during <23% of the paint tasks. According to marginal R(2) statistics, mixed models generated in this study described no <36% of the variability in dermal concentrations of the different polyisocyanates measured in painters who did not wear protective clothing. These models also described 55% of the variability in dermal concentrations of isocyanurate measured in all painters (N = 288 paint tasks). The product of analyte-specific breathing-zone concentration (BZC) and paint time was the most significant variable in all the models. Through LMM, a better understanding of the exposure pathways governing individual polyisocyanate exposures may be achieved. In particular, we were able to establish a link between BZC and dermal concentration, which may be useful for exposure reconstruction and quantitatively characterizing the protective effect of coveralls and gloves. This information can be used to reduce dermal exposures and better protect automotive spray painters from potential adverse health effects.


Annals of Occupational Hygiene | 2010

Urine 1,6-hexamethylene diamine (HDA) levels among workers exposed to 1,6-hexamethylene diisocyanate (HDI).

Linda G. Trelles Gaines; Kenneth W. Fent; Sheila L. Flack; Jennifer M. Thomasen; Louise M. Ball; David B. Richardson; Kai Ding; Stephen G. Whittaker; Leena A. Nylander-French

Urinary 1,6-hexamethylene diamine (HDA) may serve as a biomarker for systemic exposure to 1,6-hexamethylene diisocyanate (HDI) in occupationally exposed populations. However, the quantitative relationships between dermal and inhalation exposure to HDI and urine HDA levels have not been established. We measured acid-hydrolyzed urine HDA levels along with dermal and breathing-zone levels of HDI in 48 automotive spray painters. These measurements were conducted over the course of an entire workday for up to three separate workdays that were spaced approximately 1 month apart. One urine sample was collected before the start of work with HDI-containing paints and subsequent samples were collected during the workday. HDA levels varied throughout the day and ranged from nondetectable to 65.9 microg l(-1) with a geometric mean and geometric standard deviation of 0.10 microg l(-1) +/- 6.68. Dermal exposure and inhalation exposure levels, adjusted for the type of respirator worn, were both significant predictors of urine HDA levels in the linear mixed models. Creatinine was a significant covariate when used as an independent variable along with dermal and respirator-adjusted inhalation exposure. Consequently, exposure assessment models must account for the water content of a urine sample. These findings indicate that HDA exhibits a biphasic elimination pattern, with a half-life of 2.9 h for the fast elimination phase. Our results also indicate that urine HDA level is significantly associated with systemic HDI exposure through both the skin and the lungs. We conclude that urinary HDA may be used as a biomarker of exposure to HDI, but biological monitoring should be tailored to reliably capture the intermittent exposure pattern typical in this industry.


Journal of Occupational and Environmental Hygiene | 2012

Airborne isocyanate exposures in the collision repair industry and a comparison to occupational exposure limits.

Carolyn Reeb-Whitaker; Stephen G. Whittaker; Diana M. Ceballos; Elisa C. Weiland; Sheila L. Flack; Kenneth W. Fent; Jennifer M. Thomasen; Linda G. Trelles Gaines; Leena A. Nylander-French

Isocyanate exposure was evaluated in 33 spray painters from 25 Washington State autobody shops. Personal breathing zone samples (n = 228) were analyzed for isophorone diisocyanate (IPDI) monomer, 1,6-hexamethylene diisocyanate (HDI) monomer, IPDI polyisocyanate, and three polyisocyanate forms of HDI. The objective was to describe exposures to isocyanates while spray painting, compare them with short-term exposure limits (STELs), and describe the isocyanate composition in the samples. The composition of polyisocyanates (IPDI and HDI) in the samples varied greatly, with maximum amounts ranging from up to 58% for HDI biuret to 96% for HDI isocyanurate. There was a significant inverse relationship between the percentage composition of HDI isocyanurate to IPDI and to HDI uretdione. Two 15-min STELs were compared: (1) Oregons Occupational Safety and Health Administration (OR-OSHA) STEL of 1000 μg/m3 for HDI polyisocyanate, and (2) the United Kingdoms Health and Safety Executive (UK-HSE) STEL of 70 μg NCO/m3 for all isocyanates. Eighty percent of samples containing HDI polyisocyanate exceeded the OR-OSHA STEL while 98% of samples exceeded the UK-HSE STEL. The majority of painters (67%) wore half-face air-purifying respirators while spray painting. Using the OR-OSHA and the UK-HSE STELs as benchmarks, 21% and 67% of painters, respectively, had at least one exposure that exceeded the respirators OSHA-assigned protection factor. A critical review of the STELs revealed the following limitations: (1) the OR-OSHA STEL does not include all polyisocyanates, and (2) the UK-HSE STEL is derived from monomeric isocyanates, whereas the species present in typical spray coatings are polyisocyanates. In conclusion, the variable mixtures of isocyanates used by autobody painters suggest that an occupational exposure limit is required that includes all polyisocyanates. Despite the limitations of the STELs, we determined that a respirator with an assigned protection factor of 25 or greater is required to protect against isocyanate exposures during spray painting. Consequently, half-face air-purifying respirators, which are most commonly used and have an assigned protection factor of 10, do not afford adequate respiratory protection.


Annals of Occupational Hygiene | 2010

Quantitative Plasma Biomarker Analysis in HDI Exposure Assessment

Sheila L. Flack; Kenneth W. Fent; Linda G. Trelles Gaines; Jennifer M. Thomasen; Steve Whittaker; Louise M. Ball; Leena A. Nylander-French

Quantification of amines in biological samples is important for evaluating occupational exposure to diisocyanates. In this study, we describe the quantification of 1,6-hexamethylene diamine (HDA) levels in hydrolyzed plasma of 46 spray painters applying 1,6-hexamethylene diisocyanate (HDI)-containing paint in vehicle repair shops collected during repeated visits to their workplace and their relationship with dermal and inhalation exposure to HDI monomer. HDA was detected in 76% of plasma samples, as heptafluorobutyryl derivatives, and the range of HDA concentrations was < or =0.02-0.92 microg l(-1). After log-transformation of the data, the correlation between plasma HDA levels and HDI inhalation exposure measured on the same workday was low (N = 108, r = 0.22, P = 0.026) compared with the correlation between plasma HDA levels and inhalation exposure occurring approximately 20 to 60 days before blood collection (N = 29, r = 0.57, P = 0.0014). The correlation between plasma HDA levels and HDI dermal exposure measured on the same workday, although statistically significant, was low (N = 108, r = 0.22, P = 0.040) while the correlation between HDA and dermal exposure occurring approximately 20 to 60 days before blood collection was slightly improved (N = 29, r = 0.36, P = 0.053). We evaluated various workplace factors and controls (i.e. location, personal protective equipment use and paint booth type) as modifiers of plasma HDA levels. Workers using a downdraft-ventilated booth had significantly lower plasma HDA levels relative to semi-downdraft and crossdraft booth types (P = 0.0108); this trend was comparable to HDI inhalation and dermal exposure levels stratified by booth type. These findings indicate that HDA concentration in hydrolyzed plasma may be used as a biomarker of cumulative inhalation and dermal exposure to HDI and for investigating the effectiveness of exposure controls in the workplace.


Biomarkers | 2011

Hemoglobin adducts in workers exposed to 1,6-hexamethylene diisocyanate

Sheila L. Flack; Kenneth W. Fent; Linda G. Trelles Gaines; Jennifer M. Thomasen; Stephen G. Whittaker; Louise M. Ball; Leena A. Nylander-French

We investigated the utility of 1,6-hexamethylene diamine (HDA) hemoglobin adducts as biomarkers of exposure to 1,6-hexamethylene diisocyanate (HDI) monomer. Blood samples from 15 spray painters applying HDI-containing paint were analyzed for hemoglobin HDA (HDA-Hb) and N-acetyl-1,6-hexamethylene diamine (monoacetyl-HDA-Hb) by GC-MS. HDA-Hb was detected in the majority of workers (≤1.2–37 ng/g Hb), whereas monoacetyl-HDA-Hb was detected in one worker (0.06 ng/g Hb). The stronger, positive association between HDA-Hb and cumulative HDI exposure (r2 = 0.3, p < 0.06) than same day exposure (p ≥ 0.13) indicates long-term elimination kinetics for HDA-Hb adducts. This association demonstrates the suitability of HDA-Hb adducts for further validation as a biomarker of HDI exposure.


Journal of Occupational and Environmental Hygiene | 2011

Survey of Dermal Protection in Washington State Collision Repair Industry

Diana M. Ceballos; Kenneth W. Fent; Stephen G. Whittaker; Linda G. Trelles Gaines; Jennifer M. Thomasen; Sheila L. Flack; Leena A. Nylander-French; Michael G. Yost; Carolyn Reeb-Whitaker

Substantial exposure to isocyanates may occur during spray painting in autobody shops, yet information is lacking on the efficacy of the protective clothing used during spray painting. We investigated the personal and workplace factors associated with painters’ dermal protection use during a large-scale exposure assessment study. Survey data indicated that 69% of painters always used gloves, with latex gloves (47%) and nitrile gloves (34%) used most frequently. Among latex glove users, 53% used thin latex (0.05–0.13 mm), 6% used medium latex (0.15–0.20 mm), and 12% used thick latex (> 0.20 mm). Among nitrile glove users, 27% used thin nitrile and 45% used medium nitrile. Sixty-three percent of painters always used coveralls, 44% preferring one particular brand. Although overspray presents an opportunity for dermal exposure to the neck and face, only 19% of painters protected these areas with personal protective equipment. Painters who always used coveralls were more likely to use gloves (odds ratio = 7.9, p = 0.061). Painters who reported ever having smoked cigarettes used gloves (p = 0.05) and coveralls (p = 0.04) more frequently. Painters who sprayed more than 34 clear coat jobs per month used coveralls most frequently (p = 0.038). Exact logistic regressions along with random sample calculations indicated that the survey results were independent of the shops. Because of the small sample size in this study, future research is warranted to corroborate these results. Studying the effectiveness of gloves and coveralls against polyurethane paints and understanding the underlying motivators and preferences for painters and business owners is needed for the development of best practices for the selection and use of dermal protection.


Journal of Environmental Monitoring | 2012

Penetration patterns of monomeric and polymeric 1,6-hexamethylene diisocyanate monomer in human skin

Jennifer M. Thomasen; Leena A. Nylander-French

We investigated penetration patterns of monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI), experimentally and as part of commercial products, in excised full-thickness human skin at 5, 10, 30, or 60 min after exposure. We observed that both monomeric and polymeric HDI were readily absorbed into the skin and that the clearcoat composition affects the penetration rate of the individual isocyanates. The short-term absorption rates for HDI monomer, biuret, and isocyanurate were determined and used to estimate the exposure time required to reach a body burden equal to the American Conference of Governmental Industrial Hygienists (ACGIH) inhalation threshold limit value (TLV) or Oregon State occupational exposure limit (OEL). Oregon is the only government entity in the United States to promulgate a short-term exposure limit (STEL) for HDI-based polyisocyanates biuret and isocyanurate. Based on these absorption rates for a slow-drying clearcoat after 10 min (1.33 μg cm(-2) h(-1)) or 60 min (0.219 μg cm(-2) h(-1)), we calculated that 6.5 and 40 min dermal exposure, respectively, is required to achieve a dose of HDI equivalent to the ACGIH TLV. For biuret, the time to achieve a dose equivalent to the Oregon OEL for slow-drying clearcoat was much shorter (<31 min) than that for fast-drying clearcoat (618 min). Isocyanurate had the shortest skin absorption times regardless of clearcoat formulation (14 s-1.7 min). These results indicate that the dose received through dermal exposure to HDI-containing clearcoats has a significant potential to exceed the dose equivalent to that received through inhalation exposure at established regulatory limits. A critical need exists to monitor dermal exposure quantitatively in exposed workers, to use proper protective equipment to reduce dermal exposure, and to re-evaluate regulatory exposure limits for isocyanates.


Journal of Occupational and Environmental Hygiene | 2011

Development of a Sampling Patch to Measure Dermal Exposures to Monomeric and Polymeric 1,6-Hexamethylene Diisocyanate: A Pilot Study

Jennifer M. Thomasen; Kenneth W. Fent; Leena A. Nylander-French

The purpose of this study was to develop and evaluate a patch sampler to monitor dermal exposures to monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) in the automotive refinishing industry. Different patch materials were used to construct the patches, and patches impregnated with a derivatizing solution were compared with those that were not impregnated. We observed that impregnated felt patches measured significantly more HDI monomer (p = 0.04) than non-impregnated patches in a controlled experiment. Both impregnated and non-impregnated patches were compared with the tape-strip method by monitoring three spray painters’ dermal exposure to monomeric and polymeric HDI. Isocyanurate was the predominant species measured by all three sampler types with detectable levels in >86% of samples. Overall, tape-strips of exposed skin measured lower levels of monomeric and polymeric HDI than impregnated patch samplers at the same sampling site on the skin. Unlike tape-strips, impregnated patches are not as prone to evaporative or reactive losses or losses due to rapid penetration into the skin. Further investigations are warranted to evaluate these and other methods to measure dermal exposure to workers under occupational conditions to better understand the relationship between dermal exposure and internal dose.


Journal of Occupational and Environmental Hygiene | 2011

Field comparison of air sampling methods for monomeric and polymeric 1,6-hexamethylene diisocyanate.

Jennifer M. Thomasen; Kenneth W. Fent; Carolyn Reeb-Whitaker; Stephen G. Whittaker; Leena A. Nylander-French

This study was to critically compared 13 different air samplers for their ability to monitor air exposures to monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) in the automotive refinishing industry. Using both fast- and slow-drying clearcoat, we tested the following types of samplers: single- and dual-stage 37-mm polypropylene (PP) and polystyrene (PS) samplers (open- and closed-face), IOM (with plastic and stainless steel inserts), OSHA42, IsoChek, and WA-DOSH samplers. Midget impingers with frit were used as reference samplers. We observed the PP, PS, and IOM samplers to measure greater levels of HDI monomer and biuret when a fast-drying clearcoat was applied compared with a slow-drying clearcoat. When a slow-drying clearcoat was applied, the open-face PP and PS samplers measured significantly more monomeric and polymeric HDI (2-fold; p < 0.003) than the closed-face PP and PS samplers. We determined that significantly more monomeric and polymeric HDI were measured by impingers (1.3–1.9-fold) compared with single-stage PP/PS (N = 59), dual-stage PP/PS (N = 59), or IOM (N = 24) samplers. However, when stratified by cassette characteristics, the open-face single-stage PP and PS samplers performed equally to the impingers for HDI monomer when a fast-drying clearcoat was applied, and for all analytes when a slow-drying clearcoat was applied. Significantly higher HDI monomer concentrations (1.2–3.1-fold; p = 0.001) were measured with OSHA42 compared with the impinger. The IsoChek did not detect HDI monomer, and of the three samplers analyzed by laboratories other than UNC (i.e., OSHA42, IsoChek, and WA-DOSH), the WA-DOSH was in the best agreement with the impingers. The influence of clearcoat drying time on the samplers ability to measure monomeric and polymeric HDI emphasizes the importance of the speciation of diisocyanates in chemical analysis and the careful consideration for the selection of the air sampler to be used when measuring exposures during automotive spray painting.

Collaboration


Dive into the Jennifer M. Thomasen's collaboration.

Top Co-Authors

Avatar

Leena A. Nylander-French

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Kenneth W. Fent

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Linda G. Trelles Gaines

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Sheila L. Flack

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Carolyn Reeb-Whitaker

United States Department of State

View shared research outputs
Top Co-Authors

Avatar

Louise M. Ball

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Kai Ding

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Amy H. Herring

University of North Carolina at Chapel Hill

View shared research outputs
Top Co-Authors

Avatar

Elisa C. Weiland

United States Department of State

View shared research outputs
Researchain Logo
Decentralizing Knowledge