Jennifer Rice
Neogen Corporation
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Jennifer Rice.
Talanta | 2013
Waqass Jawaid; Julie P. Meneely; Katrina Campbell; Mark Hooper; Karrie Melville; Stephen J. Holmes; Jennifer Rice; Christopher T. Elliott
A lateral flow immunoassay (LFIA) has been developed and fully validated to detect the primary amnesic shellfish poisoning (ASP) toxin, domoic acid (DA). The performance characteristics of two versions of the test were investigated using spiked and naturally contaminated shellfish (mussels, scallops, oysters, clams, and cockles). The tests provide a qualitative result, to indicate the absence or presence of DA in extracts of shellfish tissues, at concentrations that are relevant to regulatory limits. The new rapid assay (LFIA version 2) was designed to overcome the performance limitations identified in the first version of the assay. The improved test uses an electronic reader to remove the subjective nature of the generated results, and the positive cut-off for screening of DA in shellfish was increased from 10 ppm (version 1) to 17.5 ppm (version 2). A simple extraction and test procedure was employed, which required minimal equipment and materials; results were available 15 min after sample preparation. Stability of the aqueous extracts at room temperature (22 °C) at four time points (up to 245 min after extraction) and across a range of DA concentrations was 100.3±1.3% and 98.8±2.4% for pre- and post-buffered extracts, respectively. The assay can be used both within laboratory settings and in remote locations. The accuracy of the new assay, to indicate negative results at or below 10 ppm DA, and positive results at or above 17.5 ppm, was 99.5% (n=216 tests). Validation data were obtained from a 2-day, randomised, blind study consisting of multiple LFIA lots (n=3), readers (n=3) and operators (n=3), carrying out multiple extractions of mussel tissue (n=3) at each concentration (0, 10, 17.5, and 20 ppm). No matrix effects were observed on the performance of the assay with different species (mussels, scallops, oysters, clams, and cockles). There was no impact on accuracy or interference from other phycotoxins, glutamic acid or glutamine with various strip incubations (8, 10, and 12 min). The accuracy of the assay, using naturally contaminated samples to indicate negative results at or below 12.5 ppm and positive results at or above 17.5 ppm, was 100%. Variability between three LFIA lots across a range of DA concentrations, expressed as coefficient of variation (% CV), was 1.1±0.4% (n=2 days) based on quantitative readings from the electronic reader. During an 8 week stability study, accuracy of the method with test strips stored at various temperatures (6, 22, 37 and 50 °C) was 100%. Validation for both versions included comparisons with results obtained using reference LC-UV methods.
Analytical Chemistry | 2015
Waqass Jawaid; Katrina Campbell; Karrie Melville; Stephen J. Holmes; Jennifer Rice; Christopher T. Elliott
A single-step lateral flow immunoassay (LFIA) was developed and validated for the rapid screening of paralytic shellfish toxins (PSTs) from a variety of shellfish species, at concentrations relevant to regulatory limits of 800 μg STX-diHCl equivalents/kg shellfish meat. A simple aqueous extraction protocol was performed within several minutes from sample homogenate. The qualitative result was generated after a 5 min run time using a portable reader which removed subjectivity from data interpretation. The test was designed to generate noncompliant results with samples containing approximately 800 μg of STX-diHCl/kg. The cross-reactivities in relation to STX, expressed as mean ± SD, were as follows: NEO: 128.9% ± 29%; GTX1&4: 5.7% ± 1.5%; GTX2&3: 23.4% ± 10.4%; dcSTX: 55.6% ± 10.9%; dcNEO: 28.0% ± 8.9%; dcGTX2&3: 8.3% ± 2.7%; C1&C2: 3.1% ± 1.2%; GTX5: 23.3% ± 14.4% (n = 5 LFIA lots). There were no indications of matrix effects from the different samples evaluated (mussels, scallops, oysters, clams, cockles) nor interference from other shellfish toxins (domoic acid, okadaic acid group). Naturally contaminated sample evaluations showed no false negative results were generated from a variety of different samples and profiles (n = 23), in comparison to reference methods (MBA method 959.08, LC-FD method 2005.06). External laboratory evaluations of naturally contaminated samples (n = 39) indicated good correlation with reference methods (MBA, LC-FD). This is the first LFIA which has been shown, through rigorous validation, to have the ability to detect most major PSTs in a reliable manner and will be a huge benefit to both industry and regulators, who need to perform rapid and reliable testing to ensure shellfish are safe to eat.
Journal of Agricultural and Food Chemistry | 2015
Waqass Jawaid; Julie P. Meneely; Katrina Campbell; Karrie Melville; Stephen J. Holmes; Jennifer Rice; Christopher T. Elliott
A single-step lateral flow immunoassay was developed and validated to detect okadaic acid (OA) and dinophysis toxins (DTXs), which cause diarrhetic shellfish poisoning. The performance characteristics of the test were investigated, in comparison to reference methods (liquid chromatography tandem mass spectrometry and/or bioassay), using both spiked and naturally contaminated shellfish. A portable reader was used to generate a qualitative result, indicating the absence or presence of OA-group toxins, at concentrations relevant to the maximum permitted level (MPL). Sample homogenates could be screened in 20 min (including extraction and assay time) for the presence of free toxins (OA, DTX1, DTX2). DTX3 detection could be included with the addition of a hydrolysis procedure. No matrix effects were observed from the species evaluated (mussels, scallops, oysters, and clams). Results from naturally contaminated samples (n = 72) indicated no false compliant results and no false noncompliant results at <50% MPL. Thus, the development of a new low-cost but highly effective tool for monitoring a range of important phycotoxins has been demonstrated.
Journal of AOAC International | 2015
Caballero O; Susan Alles; Quynh-Nhi Le; Mark Mozola; Jennifer Rice
NeoFilm Yeast and Mold (Y&M), also known as Sanita-kun Yeasts and Molds, is a simple, effective device used for the enumeration of yeasts and molds. It consists of a nonwoven fabric on which a layer of microbial nutrients is deposited in a film. A 1 mL sample homogenate is applied to the membrane and this, in turn, is incubated for 48-72 h at 25°C. Sample homogenates were prepared using two different diluents for customer convenience: phosphate buffered saline (PBS) and 0.1% peptone water. In comparative testing of breaded chicken nuggets, dry pet food, orange juice concentrate, yogurt, and cake mix, there were statistically significant differences in the counts obtained by the NeoFilm Y&M and U.S. Food and Drug Administration Bacteriological Analytical Manual reference culture methods only in the following instances: medium level for orange juice with PBS as diluent and low level for pet food with 0.1% peptone water as diluent, where reference method counts were higher than those of NeoFilm; medium level for cake mix with PBS, and low and medium levels for cake mix with 0.1% peptone water, where NeoFilm produced higher counts than the reference method. In addition to the method comparison study with five matrixes, robustness and stability/lot-to-lot testing were also performed. Results of robustness testing showed no significant effect on results even with perturbation to three assay parameters simultaneously. Results of testing of three lots of devices ranging in age from 2 to 26 months post-manufacture showed no significant differences in performance.
Journal of AOAC International | 2014
Debra Foti; Lei Zhang; Preetha Biswas; Mark Mozola; Jennifer Rice
A matrix extension study was conducted to validate the ANSR(®) Salmonella method for use with pasteurized egg products. Four diverse egg product types were tested by the ANSR method and the U.S. Department of Agricultures Microbiology Laboratory Guidebook reference culture procedure. There were no significant differences in the number of positive test portions by the two methods for any of the products examined. Independent laboratory testing of pasteurized liquid egg also found no significant difference in performance between the ANSR and reference culture procedures. There were no false-positive results obtained in either internal or independent laboratory testing. Inclusivity testing using a new enrichment medium specifically designed for use with pasteurized egg products produced 112 positive results out of 113 Salmonella spp. strains tested, with only a single strain of S. Weslaco testing negative by the ANSR assay. Exclusivity testing of 38 non-salmonellae produced all negative ANSR results. It is concluded that ANSR Salmonella is a reliable, sensitive, and specific method for detection of Salmonella spp. in pasteurized egg products.
Journal of AOAC International | 2017
Brooke Roman; Dana Driksna; Mohamed Abouzied; Frank Klein; Jennifer Rice
Neogen Corp. (Lansing, MI) has developed a common aqueous extraction method for the detection of mycotoxins in the ELISA or lateral flow format. The Veratox® for Total Aflatoxin ELISA extraction method uses a MAX 2 extraction packet and water in replacement of traditionally used organic solvents. Veratox for Total Aflatoxin has a detection range of 5-50 ppb neat or up to 300 ppb with dilution. The kit development focused on superior cross-reactivity, ability to accurately detect naturally contaminated samples, and utilization of an aqueous extraction method. In two separate validation studies, the Veratox for Total Aflatoxin test kit resulted in average yields of 91-114% in naturally contaminated mycotoxin reference material corn. The cross-reactivity profiles for aflatoxins B1, B2, G1, and G2 were 100, 113, 103, and 93%, respectively. This kit is approved by the Grain Inspection, Packers, and Stockyards Administration.
Journal of AOAC International | 2016
Ryan Viator; Susan Alles; Quynh-Nhi Le; Edan Hosking; Preetha Biswas; Lei Zhang; Tolan J; Evan Meister; Eric Tovar; Lisa Pinkava; Mark Mozola; Jennifer Rice; Yi Chen; Odumeru J; Wayne Ziemer
A performance validation of the ANSR® for Campylobacter method was conducted in selected matrixes. This assay used selective nicking enzyme amplification technology to amplify target genes. Samples were enriched for 20 to 24 h and then lysed. The assay was completed within 50 min using real-time detection in a combination incubator/fluorescence detector and software. When 50 distinct strains of Campylobacter jejuni, C. lari, or C. coli were tested for inclusivity, all 50 strains produced positive results. In exclusivity testing, 31 strains of related organisms, including seven nontarget Campylobacter strains and other common species, were evaluated. All 31 species generated negative ANSR assay results, including the nontarget Campylobacter strains. The ANSR for Campylobacter method was compared to the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method using naturally contaminated chicken carcass rinse or turkey carcass sponge samples. ANSR method performance was not statistically different from the reference method using two different enrichment options. Equivalent results were observed at both time points (20 and 24 h) and in both atmospheres (microaerobic and aerobic) to reference methods. Method performance with chicken carcass rinse was confirmed in an independent laboratory study. Additionally, in robustness testing, small, deliberate changes to the assay parameters minimally affected ANSR method performance. Finally, accelerated stability results from three independently manufactured lots supported a shelf life of 6 months when stored at 4°C. The ANSR assay offered greater efficiency and flexibility when compared to the reference method with a 20-24 h single-step enrichment in a microaerobic or an aerobic atmosphere.
Journal of AOAC International | 2016
Ryan Viator; Susan Alles; Quynh-Nhi Le; Edan Hosking; Evan Meister; Lisa Pinkava; Eric Tovar; Mark Mozola; Jennifer Rice
A performance validation of the ANSR(®) for E. coli O157:H7 method was conducted in selected food matrixes. This assay uses selective nicking enzyme amplification technology to amplify target genes. Samples are enriched for 12-24 h and then lysed. The assay is completed within 40 min using real-time detection in a combination incubator/fluorescence detector and software. When 44 distinct strains of Escherichia coli O157:H7 and 6 strains of E. coli O157:NM were tested for inclusivity, all 50 strains produced positive results. In exclusivity testing, 57 strains representing 33 species of closely related Gram-negative bacteria belonging to the Enterobacteriaceae family, including 11 non-H7 O157 strains and shiga toxin-producing E. coli other than O157:H7, were evaluated. All 57 nontarget strains generated negative ANSR assay results. Using 80% lean ground beef and beef trim (approximately 20% fat), ANSR method performance was compared to the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedure. ANSR performance with baby spinach and sprout irrigation water was measured against the U.S. Food and Drug Administration Bacteriological Analytical Manual reference method. ANSR method performance was not statistically different to that of the reference methods using two different enrichment options. For ground beef and beef trim, the standard enrichment in modified Tryptone Soya Broth can be analyzed using the ANSR assay with a 1:10 dilution of the enrichment in phosphate-buffered saline and produces equivalent results to the reference method. Additionally, in most matrixes tested (exception is spinach which required 24 h enrichment) the assay offers great efficiency and flexibility over the reference method with a 12-24 h single-step enrichment. Equivalent results were observed at both time points (12 and 24 h) to reference methods. Small changes to the assay parameters minimally affected ANSR method performance. Finally, accelerated stability results from three independently manufactured lots support a shelf-life of 6 months when stored at 4°C.
Journal of AOAC International | 2015
Caballero O; Susan Alles; Walton K; Gray Rl; Mark Mozola; Jennifer Rice
This paper describes the results of a study to validate minor reagent formulation and procedural changes to the ANSR® Salmonella method, AOAC Performance Tested Method™ 061203. In order to improve ease of use and diminish risk of amplicon contamination, the lyophilized reagent components were reformulated for increased solubility, thus eliminating the need to mix by pipetting. In the alternative procedure, an aliquot of the lysate is added to lyophilized ANSR reagents, immediately capped, and briefly mixed by vortex. Results of the validation study with ice cream, peanut butter, dry dog food, raw ground turkey, raw ground beef, and sponge samples from a stainless steel surface showed no statistically significant differences in performance between the ANSR method and the U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture-Food Safety and Inspection Services Microbiology Laboratory Guidebook reference culture procedures. Results of inclusivity and exclusivity testing were unchanged from those of the original validation study; exclusivity was 100% and inclusivity was 99.1% with only a single strain of Salmonella Weslaco testing negative. Robustness testing was also conducted, with variations to lysis buffer volume, lysis time, and sample volume having no demonstrable effect on assay results.
Journal of AOAC International | 2015
Caballero O; Susan Alles; Michael Wendorf; Gray Rl; Walton K; Lisa Pinkava; Mark Mozola; Jennifer Rice
ANSR® Listeria was previously certified as Performance Tested Method(SM) 101202 for detection of Listeria spp. on selected environmental surfaces. This study proposes a matrix extension to the method for detection of Listeria spp. in selected food matrixes. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in less than 50 min, requiring only simple instrumentation. Inclusivity testing was performed using a panel of 51 strains of Listeria spp., representing the species L. grayi, L. innocua, L. ivanovii, L. monocytogenes, L. seeligeri, and L. welshimeri. All strains tested were detected by the ANSR assay. Exclusivity testing of 30 strains representing non-Listeria Gram-positive bacteria yielded no evidence of cross-reactivity. Performance of the ANSR method for detection of Listeria spp. was compared to that of reference culture procedures for pasteurized liquid egg, pasteurized 2% milk, Mexican-style cheese, ice cream, smoked salmon, lettuce, cantaloupe, and guacamole. Data obtained in these unpaired studies and analyzed using a probability of detection model demonstrated that there were no statistically significant differences in results between the ANSR and reference culture methods, except for milk at 16 h and cantaloupe. In milk and smoked salmon, ANSR sensitivity was low at 16 h and therefore the recommended incubation time is 24 h. In cantaloupe, ANSR was found to be more sensitive than the reference culture method at both 16 and 24 h in independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in selected food types.