Jeongtaek Ahn
Seoul National University
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Jeongtaek Ahn.
Veterinary Ophthalmology | 2011
Young Woo Park; Manbok Jeong; Taehyun Kim; Jaesang Ahn; Jeongtaek Ahn; Shin-Ae Park; Seeun Kim; Kangmoon Seo
OBJECTIVE To evaluate the effect of central corneal thickness (CCT) on the measurement of intraocular pressure (IOP) with the rebound (TonoVet(®)) and applanation (TonoPen XL(®)) tonometers in beagle dogs. ANIMAL STUDIED Both eyes of 60 clinically normal dogs were used. PROCEDURES The IOP was measured by the TonoVet(®), followed by the TonoPen XL(®) in half of the dogs, while the other half was measured in the reverse order. All CCT measurements were performed 10 min after the use of the second tonometer. RESULTS The mean IOP value measured by the TonoVet(®) (16.9 ± 3.7 mmHg) was significantly higher than the TonoPen XL(®) (11.6 ± 2.7 mmHg; P < 0.001). The IOP values obtained by both tonometers were correlated in the regression analysis (γ(2) = 0.4393, P < 0.001). Bland-Altman analysis showed that the lower and upper limits of agreement between the two devices were -0.1 and +10.8 mmHg, respectively. The mean CCT was 549.7 ± 51.0 μm. There was a correlation between the IOP values obtained by the two tonometers and CCT readings in the regression analysis (TonoVet(®) : P = 0.002, TonoPen XL(®) : P = 0.035). The regression equation demonstrated that for every 100 μm increase in CCT, there was an elevation of 1 and 2 mmHg in IOP measured by the TonoPen XL(®) and TonoVet(®), respectively. CONCLUSIONS The IOP obtained by the TonoVet(®) and TonoPen XL(®) would be affected by variations in the CCT. Therefore, the CCT should be considered when interpreting IOP values measured by tonometers in dogs.
Journal of Veterinary Science | 2013
Taehyun Kim; Young Woo Park; Jaesang Ahn; Jeongtaek Ahn; Seeun Kim; Manbok Jeong; Min-Su Seo; Kyung-Sun Kang; Kangmoon Seo
This study was performed to evaluate the effects of conditioned media (CM) from human amniotic epithelial cells (HAECs) on the corneal wound healing process. Eighteen rabbits (36 eyes) were used and randomly assigned to three groups according treatment: CM from HAECs (group 1), vehicle alone (group 2), and saline (group 3). Corneal alkali injuries were induced with 1 N sodium hydroxide. Each reagent used for treatment evaluation was injected into the dorsal bulbar subconjunctiva and the area of the corneal epithelial defect was measured every other day. Two animals from each group were euthanized at a time on days 3, 7, and 15, and the cornea was removed for histological examination. The sum of the epithelial defect areas measured on day 0 to day 6 as well as day 0 to day 14 in group 1 was significantly smaller than those of other groups. Histological examination revealed that the group 1 corneas had less inflammatory cell infiltration and showed more intact epithelial features compared to the other groups. These results suggest that CM from HAECs promote corneal wound healing in rabbits.
Veterinary Ophthalmology | 2012
Jeongtaek Ahn; Manbok Jeong; Young Woo Park; Seeun Kim; Jaesang Ahn; Euiri Lee; Kangmoon Seo
OBJECTIVE To compare and evaluate the accuracy of intraocular pressure (IOP) measured through a therapeutic contact lens, using applanation (TonoPen XL(®)) and rebound (TonoVet(®)) tonometers in enucleated dog eyes. ANIMALS STUDIED A total of 30 enucleated eyes from 15 beagle dogs. PROCEDURES To measure accurate IOP, the anterior chamber of each enucleated eye was cannulated with two 26-gauge needles and two polyethylene tubes were connected vertically to an adjustable reservoir bag of normal saline and a pressure transducer. IOP was measured by the TonoPen XL(®) followed by the TonoVet(®) without a contact lens. After a contact lens was applied to the cornea, IOP was re-measured in the same order. Three consecutive IOP measurements were performed using both tonometers. RESULTS Without the contact lens, the IOP values obtained by both tonometers correlated well according to the regression analysis (TonoVet(®): γ(2) = 0.98, TonoPen XL(®): γ(2) = 0.97, P < 0.001). The TonoPen XL(®) consistently underestimated values as transducer IOP increased; however, IOP values measured with the TonoPen XL(®) were in close agreement and were less variable than those determined with the TonoVet(®) when a contact lens was applied to the cornea. Bland-Altman analysis was used to determine the lower and upper limits of agreement (TonoVet(®): -29.7 and +21.1 mmHg, TonoPen XL(®): -3.9 and +3.6 mmHg) between the two devices. CONCLUSIONS This study suggests that the TonoPen XL(®) is a useful tonometer for dogs wearing therapeutic contact lenses, and importantly, contact lenses would not need to be removed prior to IOP measurement.
Journal of Veterinary Clinics | 2010
Jeongtaek Ahn; Manbok Jeong; Seeun Kim; Young Woo Park; Taehyun Kim; Jaesang Ahn; Sora Lee; Chang Woo Lee; Kangmoon Seo
한국임상수의학회지 | 2011
Jaesang Ahn; Seeun Kim; Young Woo Park; Jeongtaek Ahn; Euiri Lee; Kangmoon Seo; Manbok Jeong
한국임상수의학회지 | 2011
Young Woo Park; Seeun Kim; Jaesang Ahn; Jeongtaek Ahn; Euiri Lee; Na-Young Yi; Kangmoon Seo; Manbok Jeong
한국임상수의학회 학술대회논문집 | 2009
Taehyun Kim; Manbok Jeong; Seeun Kim; Young Woo Park; Jaesang Ahn; Jeongtaek Ahn; Y. Ha; Chanhee Chae; Kangmoon Seo
한국임상수의학회 학술대회논문집 | 2009
Young Woo Park; Shin-Ae Park; Won-Tae Kim; Seeun Kim; Taehyun Kim; Jaesang Ahn; Jeongtaek Ahn; Manbok Jeong; Kangmoon Seo
한국임상수의학회 학술대회논문집 | 2009
Jeongtaek Ahn; Manbok Jeong; Seeun Kim; Young Woo Park; Taehyun Kim; Jaesang Ahn; Sora Lee; Chang Woo Lee; Kangmoon Seo
한국임상수의학회 학술대회논문집 | 2009
Seeun Kim; Won-Tae Kim; Young Woo Park; Taehyun Kim; Jaesang Ahn; Jeongtaek Ahn; Junyoung Kim; Jaeyun Ko; Manbok Jeong; Oh-Kyeong Kweon; Kangmoon Seo