Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jesper Gantelius is active.

Publication


Featured researches published by Jesper Gantelius.


Angewandte Chemie | 2016

3D Bioprinting of Tissue/Organ Models

Falguni Pati; Jesper Gantelius; Helene Andersson Svahn

Inu2005vitro tissue/organ models are useful platforms that can facilitate systematic, repetitive, and quantitative investigations of drugs/chemicals. The primary objective when developing tissue/organ models is to reproduce physiologically relevant functions that typically require complex culture systems. Bioprinting offers exciting prospects for constructing 3D tissue/organ models, as it enables the reproducible, automated production of complex living tissues. Bioprinted tissues/organs may prove useful for screening novel compounds or predicting toxicity, as the spatial and chemical complexity inherent to native tissues/organs can be recreated. In this Review, we highlight the importance of developing 3D inu2005vitro tissue/organ models by 3D bioprinting techniques, characterization of these models for evaluating their resemblance to native tissue, and their application in the prioritization of lead candidates, toxicity testing, and as disease/tumor models.


Journal of Virological Methods | 2009

Development of a magnetic bead microarray for simultaneous and simple detection of four pestiviruses.

Neil LeBlanc; Jesper Gantelius; Jochen M. Schwenk; Karl Ståhl; Jonas Blomberg; Helene Andersson-Svahn; Sándor Belák

This study reports a novel method for the rapid detection and identification of the four recognized species in the pestivirus genus of the Flaviviridae family, i.e. classical swine fever virus (CSFV), border disease virus (BDV), bovine viral diarrhoea virus type 1 (BVDV1) and type 2 (BVDV2). The analysis of pestivirus PCR products was performed on microarrays by means of magnetic bead detection. The process utilizes an oligonucleotide array, onto which 5 biotinylated PCR products were hybridized, followed by visualization with streptavidin-coated magnetic particles by the naked eye, microscope or biochip reader. The assay was tested on a collection of pestiviruses that included all four species and allowed a specific and sensitive detection. Sensitivity was compared with other post-PCR detection methods, namely gel electrophoresis and suspension microarray. The results indicate that due to its high sensitivity, specificity and simple detection procedure, the magnetic bead assay provides a powerful tool for detection and identification of viral pathogens. Considering the simplicity of the assay, the protocols for hybridization and magnetic bead detection offer an emerging application for molecular diagnoses in virology that is amenable for use in a modestly equipped laboratory.


Journal of Microbiological Methods | 2010

A lateral flow protein microarray for rapid determination of contagious bovine pleuropneumonia status in bovine serum

Jesper Gantelius; Carl Hamsten; Maja Neiman; Jochen M. Schwenk; Anja Persson; Helene Andersson-Svahn

Novel analytical methods for a next generation of diagnostic devices combine attributes from sensitive, accurate, fast, simple and multiplexed analysis methods. Here, we describe a possible contribution to these by the application of a lateral flow microarray where a panel of recombinant protein antigens was used to differentiate bovine serum samples in the context of the lung disease contagious bovine pleuropneumonia (CBPP). Lateral flow arrays were produced by attaching nitrocellulose onto microscopic slides and spotting of the recombinant proteins onto the membranes. The developed assay included evaluations of substrate matrix and detection reagents to allow for short assay times and convenient read-out options, and to yield a total assay time from sample application to data acquisition of less than ten minutes. It was found that healthy and disease-affected animals could be discriminated (AUC=97%), and we suggest that the use of an antigen panel in combination with the lateral flow device offers an emerging analytical tool towards a simplified but accurate on-site diagnosis.


Clinical Chemistry | 2014

Point-of-Care Vertical Flow Allergen Microarray Assay: Proof of Concept

Thiruppathiraja Chinnasamy; Loes Irene Segerink; Mats Nystrand; Jesper Gantelius; Helene Andersson Svahn

BACKGROUNDnSophisticated equipment, lengthy protocols, and skilled operators are required to perform protein microarray-based affinity assays. Consequently, novel tools are needed to bring biomarkers and biomarker panels into clinical use in different settings. Here, we describe a novel paper-based vertical flow microarray (VFM) system with a multiplexing capacity of at least 1480 microspot binding sites, colorimetric readout, high sensitivity, and assay time of <10 min before imaging and data analysis.nnnMETHODnAffinity binders were deposited on nitrocellulose membranes by conventional microarray printing. Buffers and reagents were applied vertically by use of a flow controlled syringe pump. As a clinical model system, we analyzed 31 precharacterized human serum samples using the array system with 10 allergen components to detect specific IgE reactivities. We detected bound analytes using gold nanoparticle conjugates with assay time of ≤10 min. Microarray images were captured by a consumer-grade flatbed scanner.nnnRESULTSnA sensitivity of 1 ng/mL was demonstrated with the VFM assay with colorimetric readout. The reproducibility (CV) of the system was <14%. The observed concordance with a clinical assay, ImmunoCAP, was R(2) = 0.89 (n = 31).nnnCONCLUSIONSnIn this proof-of-concept study, we demonstrated that the VFM assay, which combines features from protein microarrays and paper-based colorimetric systems, could offer an interesting alternative for future highly multiplexed affinity point-of-care testing.


Analyst | 2014

A lateral flow paper microarray for rapid allergy point of care diagnostics

Thiruppathiraja Chinnasamy; Loes Irene Segerink; Mats Nystrand; Jesper Gantelius; Helene Andersson Svahn

There is a growing need for multiplexed specific IgE tests that can accurately evaluate patient sensitization profiles. However, currently available commercial tests are either single/low-plexed or require sophisticated instrumentation at considerable cost per assay. Here, we present a novel convenient lateral flow microarray-based device that employs a novel dual labelled gold nanoparticle-strategy for rapid and sensitive detection of a panel of 15 specific IgE responses in 35 clinical serum samples. Each gold nanoparticle was conjugated to an optimized ratio of HRP and anti-IgE, allowing significant enzymatic amplification to improve the sensitivity of the assay as compared to commercially available detection reagents. The mean inter-assay variability of the developed LFM assay was 12% CV, and analysis of a cohort of clinical samples (n = 35) revealed good general agreement with ImmunoCAP, yet with a varying performance among allergens (AUC = [0.54-0.88], threshold 1 kU). Due to the rapid and simple procedure, inexpensive materials and read-out by means of a consumer flatbed scanner, the presented assay may provide an interesting low-cost alternative to existing multiplexed methods when thresholds >1 kU are acceptable.


International Journal of Molecular Sciences | 2011

A Lateral Flow Protein Microarray for Rapid and Sensitive Antibody Assays

Jesper Gantelius; Tarek Bass; Ronald Sjöberg; Peter Nilsson; Helene Andersson-Svahn

Protein microarrays are useful tools for highly multiplexed determination of presence or levels of clinically relevant biomarkers in human tissues and biofluids. However, such tools have thus far been restricted to laboratory environments. Here, we present a novel 384-plexed easy to use lateral flow protein microarray device capable of sensitive (<30 ng/mL) determination of antigen-specific antibodies in ten minutes of total assay time. Results were developed with gold nanobeads and could be recorded by a cell-phone camera or table top scanner. Excellent accuracy with an area under curve (AUC of 98% was achieved in comparison with an established glass microarray assay for 26 antigen-specific antibodies. We propose that the presented framework could find use in convenient and cost-efficient quality control of antibody production, as well as in providing a platform for multiplexed affinity-based assays in low-resource or mobile settings.


New Biotechnology | 2009

Magnetic bead-based detection of autoimmune responses using protein microarrays.

Jesper Gantelius; Michael Hartmann; Jochen M. Schwenk; Johan Roeraade; Helene Andersson-Svahn; Thomas O. Joos

In the present study, a magnetic bead-based detection approach for protein microarrays is described as an alternative approach to the commonly used fluorescence-based detection system. Using the bead-based detection approach with applied magnetic force, it was possible to perform the detection step more rapidly as a result of the accelerated binding between the captured analyte in the microspot and the detection antibody, which was coupled to the magnetic beads. The resulting strong opacity shift on the microspots could be recorded with an ordinary flatbed scanner. In the context of autoimmunity, a set of 24 serum samples was analyzed for the presence of antibodies against 12 autoantigens using standard fluorescence and magnetic bead-based detection methods. Dynamic range, sensitivity, and specificity were determined for both detection methods. We propose from our findings that the magnetic bead-based detection option provides a simplified and cost effective readout method for protein microarrays.


Biomicrofluidics | 2014

Dean flow-coupled inertial focusing in curved channels

Harisha Ramachandraiah; Sahar Ardabili; Asim Faridi; Jesper Gantelius; Jacob M. Kowalewski; Gustaf Mårtensson; Aman Russom

Passive particle focusing based on inertial microfluidics was recently introduced as a high-throughput alternative to active focusing methods that require an external force field to manipulate particles. In inertial microfluidics, dominant inertial forces cause particles to move across streamlines and occupy equilibrium positions along the faces of walls in flows through straight micro channels. In this study, we systematically analyzed the addition of secondary Dean forces by introducing curvature and show how randomly distributed particles entering a simple u-shaped curved channel are focused to a fixed lateral position exiting the curvature. We found the lateral particle focusing position to be fixed and largely independent of radius of curvature and whether particles entering the curvature are pre-focused (at equilibrium) or randomly distributed. Unlike focusing in straight channels, where focusing typically is limited to channel cross-sections in the range of particle size to create single focusing point, we report here particle focusing in a large cross-section area (channel aspect ratio 1:10). Furthermore, we describe a simple u-shaped curved channel, with single inlet and four outlets, for filtration applications. We demonstrate continuous focusing and filtration of 10u2009μm particles (with >90% filtration efficiency) from a suspension mixture at throughputs several orders of magnitude higher than flow through straight channels (volume flow rate of 4.25u2009ml/min). Finally, as an example of high throughput cell processing application, white blood cells were continuously processed with a filtration efficiency of 78% with maintained high viability. We expect the study will aid in the fundamental understanding of flow through curved channels and open the door for the development of a whole set of bio-analytical applications.


Analyst | 2015

An 8 minute colorimetric paper-based reverse phase vertical flow serum microarray for screening of hyper IgE syndrome

Philippa Reuterswärd; Jesper Gantelius; Helene Andersson Svahn

Reverse phase microarrays are useful tools for affinity-based detection in hundreds of samples simultaneously. However, current methods typically require long assay times and fluorescent detection. Here we describe a paper-based Vertical Flow Microarray (VFM) assay as a rapid 8-minute colorimetric alternative for reverse phase microarray analysis. The VFM platform was optimized for detection of IgE with a detection limit of 1.9 μg mL(-1) in whole serum. Optimized conditions were then used to screen 113 serum samples simultaneously for hyper IgE syndrome (hIgE), a rare primary immunodeficiency characterized by elevated levels of IgE. The same set of samples were then analysed with a conventional planar microarray with fluorescent detection for head-to-head testing. Both assays found elevated levels in three out of four hIgE patient samples, whereas no control samples displayed elevated levels in either method. The comparison experiments showed a good correlation between the two assays, as determined from a linear correlation study (Pearsons r = 0.76). Further, the assay-time reduction and reproducibility (intra assay CV = 12.4 ± 4.11%) demonstrate the applicability of the VFM platform for high throughput reverse phase screening.


Talanta | 2018

A vertical flow paper-microarray assay with isothermal DNA amplification for detection of Neisseria meningitidis

Lourdes Rivas; Philippa Reuterswärd; Reza Rasti; Björn Herrmann; Andreas Mårtensson; Tobias Alfvén; Jesper Gantelius; Helene Andersson-Svahn

Paper-based biosensors offer a promising technology to be used at the point of care, enabled by good performance, convenience and low-cost. In this article, we describe a colorimetric vertical-flow DNA microarray (DNA-VFM) that takes advantage of the screening capability of DNA microarrays in a paper format together with isothermal amplification by means of Recombinase Polymerase Amplification (RPA). Different assay parameters such as hybridization buffer, flow rate, printing buffer and capture probe concentration were optimized. A limit of detection (LOD) of 4.4u202fnM was achieved as determined by tabletop scanning. The DNA-VFM was applied as a proof of concept for detection of Neisseria meningitidis, a primary cause of bacterial meningitis. The LOD was determined to be between 38 and 2.1u202f×u202f106 copies/VFMassay, depending on the choice of DNA capture probes. The presented approach provides multiplex capabilities of DNA microarrays in a paper-based format for future point-of-care applications.

Collaboration


Dive into the Jesper Gantelius's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Mats Nystrand

Thermo Fisher Scientific

View shared research outputs
Top Co-Authors

Avatar

Gustav Svedberg

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Jochen M. Schwenk

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Jorge T. Dias

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Peter Nilsson

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar

Philippa Reuterswärd

Royal Institute of Technology

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Loes Irene Segerink

MESA+ Institute for Nanotechnology

View shared research outputs
Researchain Logo
Decentralizing Knowledge