Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jessica Olofsson is active.

Publication


Featured researches published by Jessica Olofsson.


Current Opinion in Biotechnology | 2003

Single-cell electroporation

Jessica Olofsson; Kerstin Nolkrantz; Frida Ryttsén; Bradley A. Lambie; Stephen G. Weber; Owe Orwar

Electroporation is a widely used method for the introduction of polar and charged agents such as dyes, drugs, DNA, RNA, proteins, peptides, and amino acids into cells. Traditionally, electroporation is performed with large electrodes in a batch mode for treatment of a large number of cells in suspension. Recently, microelectrodes that can produce extremely localized electric fields, such as solid carbon fiber microelectrodes, electrolyte-filled capillaries and micropipettes as well as chip-based microfabricated electrode arrays, have proven useful to electroporate single cells and subcellular structures. Single-cell electroporation opens up a new window of opportunities in manipulating the genetic, metabolic, and synthetic contents of single targeted cells in tissue slices, cell cultures, in microfluidic channels or at specific loci on a chip-based device.


Soft Matter | 2010

Protrusive growth and periodic contractile motion in surface-adhered vesicles induced by Ca2+-gradients

Tatsiana Lobovkina; Irep Gözen; Yavuz Erkan; Jessica Olofsson; Stephen G. Weber; Owe Orwar

Local signaling, cell polarization, and protrusive growth are key steps in directed migration of biological cells guided by chemical gradients. Here we present a minimal system which captures several key features of cellular migration from signaling-to-motion. The model system consists of flat, negatively charged phospholipid vesicles, a negatively charged surface, and a local, and controllable point-source supply of calcium ions. In the presence of a Ca2+ gradient, the surface-adhered vesicles form protrusions in the direction of the gradient. We also observe membrane shape oscillations between expanded (flattened), and spherical states as a function of the Ca2+-concentration. The observed phenomena can be of importance in explaining motile action in prebiotic, primitive, and biomimetic systems, as well as in development of novel soft-matter nano- and microscale mechanical devices.


Analytical Chemistry | 2009

Control of the release of freely diffusing molecules in single-cell electroporation.

Aparna Agarwal; Manyan Wang; Jessica Olofsson; Owe Orwar; Stephen G. Weber

Single-cell electroporation using an electrolyte-filled capillary is an emerging technique for transient pore formation in adherent cells. Because adherent cells do not have a simple and consistent shape and because the electric field emanating from the tip of the capillary is inhomogeneous, the Schwan equation based on spherical cells in homogeneous electrical fields does not apply. We sought to determine experimental and cell parameters that influence the outcome of a single-cell electroporation experiment. A549 cells were exposed to the thiol-reactive dye Thioglo-1, leading to green fluorescence from intracellular thiol adducts. Electroporation causes a decrease with time of the intracellular fluorescence intensity of Thioglo-1-loaded cells from diffusive loss of thiol adducts. The transient curves thus obtained are well-described by a simple model originally developed by Puc et al. We find that the final fluorescence following electroporation is related to the capillary tip-to-cell distance and cell size (specifically, 2(A/pi)(1/2) where A is the area of the cells image in pixels. This quantity is the diameter if the image is a circle). In separate experiments, the relationship obtained can be used to control the final fluorescence following electroporation by adjusting the tip-to-cell distance based on cell size. The relationship was applied successfully to A549 as well as DU 145 and PC-3 cells. Finally, F-tests show that the variability in the final fluorescence (following electroporation) is decreased when the tip-to-cell distance is controlled according to the derived relationship in comparison to experiments in which the tip-cell distance is a constant irrespective of cell size.


Analytical Chemistry | 2012

Microfluidic Flow Cell for Sequential Digestion of Immobilized Proteoliposomes

Erik T. Jansson; Carolina Trkulja; Jessica Olofsson; Maria Millingen; Jennie Wikström; Aldo Jesorka; Anders Karlsson; Roger Karlsson; Max Davidson; Owe Orwar

We have developed a microfluidic flow cell where stepwise enzymatic digestion is performed on immobilized proteoliposomes and the resulting cleaved peptides are analyzed with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The flow cell channels consist of two parallel gold surfaces mounted face to face with a thin spacer and feature an inlet and an outlet port. Proteoliposomes (50-150 nm in diameter) obtained from red blood cells (RBC), or Chinese hamster ovary (CHO) cells, were immobilized on the inside of the flow cell channel, thus forming a stationary phase of proteoliposomes. The rate of proteoliposome immobilization was determined using a quartz crystal microbalance with dissipation monitoring (QCM-D) which showed that 95% of the proteoliposomes bind within 5 min. The flow cell was found to bind a maximum of 1 μg proteoliposomes/cm(2), and a minimum proteoliposome concentration required for saturation of the flow cell was determined to be 500 μg/mL. Atomic force microscopy (AFM) studies showed an even distribution of immobilized proteoliposomes on the surface. The liquid encapsulated between the surfaces has a large surface-to-volume ratio, providing rapid material transfer rates between the liquid phase and the stationary phase. We characterized the hydrodynamic properties of the flow cell, and the force acting on the proteoliposomes during flow cell operation was estimated to be in the range of 0.1-1 pN, too small to cause any proteoliposome deformation or rupture. A sequential proteolytic protocol, repeatedly exposing proteoliposomes to a digestive enzyme, trypsin, was developed and compared with a single-digest protocol. The sequential protocol was found to detect ~65% more unique membrane-associated protein (p < 0.001, n = 6) based on peptide analysis with LC-MS/MS, compared to a single-digest protocol. Thus, the flow cell described herein is a suitable tool for shotgun proteomics on proteoliposomes, enabling more detailed characterization of complex protein samples.


Analytical Chemistry | 2013

Probing Enzymatic Activity Inside Single Cells

Jessica Olofsson; Shijun Xu; Gavin D. M. Jeffries; Aldo Jesorka; Helen Bridle; Ida Isaksson; Stephen G. Weber; Owe Orwar

We report a novel approach for determining the enzymatic activity within a single suspended cell. Using a steady-state microfluidic delivery device and timed exposure to the pore-forming agent digitonin, we controlled the plasma membrane permeation of individual NG108-15 cells. Mildly permeabilized cells (~100 pores) were exposed to a series of concentrations of fluorescein diphosphate (FDP), a fluorogenic alkaline phosphatase substrate, with and without levamisole, an alkaline phosphatase inhibitor. We generated quantitative estimates for intracellular enzyme activity and were able to construct both dose-response and dose-inhibition curves at the single-cell level, resulting in an apparent Michaelis contant Km of 15.3 μM ± 1.02 (mean ± standard error of the mean (SEM), n = 16) and an inhibition constant Ki of 0.59 mM ± 0.07 (mean ± SEM, n = 14). Enzymatic activity could be monitored just 40 s after permeabilization, and five point dose-inhibition curves could be obtained within 150 s. This rapid approach offers a new methodology for characterizing enzyme activity within single cells.


Analytical Chemistry | 2005

Microfluidic gradient-generating device for pharmacological profiling

Johan Pihl; Jon Sinclair; Eskil Sahlin; Mattias Karlsson; Fredrik Petterson; Jessica Olofsson; Owe Orwar


Archive | 2003

Systems and methods for rapidly changing the solution environment around sensors

Owe Orwar; Daniel Chiu; Johan Pihl; Jon Sinclair; Jessica Olofsson; Matthias Karlsson; Kent Jardemark


Analytical Chemistry | 2007

Effect of cell size and shape on single-cell electroporation

Aparna Agarwal; Imants Zudans; Emily A. Weber; Jessica Olofsson; Owe Orwar; Stephen G. Weber


Archive | 2003

Nanoelectrodes and nanotips for recording transmembrane currents in a plurality of cells

Kent Jardemark; Aldo Jesorka; Mattias Karlsson; Jessica Olofsson; Owe Orwar; Johan Pihl; Eskil Sahlin


Analytical Chemistry | 2002

A Cell-Based Bar Code Reader for High-Throughput Screening of Ion Channel−Ligand Interactions

Jon Sinclair; Johan Pihl; Jessica Olofsson; Mattias Karlsson; Kent Jardemark; Daniel T. Chiu; Owe Orwar

Collaboration


Dive into the Jessica Olofsson's collaboration.

Top Co-Authors

Avatar

Owe Orwar

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar

Jon Sinclair

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar

Kent Jardemark

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Aldo Jesorka

Chalmers University of Technology

View shared research outputs
Top Co-Authors

Avatar

Cecilia Farre

University of Gothenburg

View shared research outputs
Top Co-Authors

Avatar

Eskil Sahlin

New Mexico State University

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Frida Ryttsén

University of Gothenburg

View shared research outputs
Researchain Logo
Decentralizing Knowledge