Jill Odabashian
Cleveland Clinic
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Jill Odabashian.
Journal of the American College of Cardiology | 2000
Mario J. Garcia; Nicholas G. Smedira; Neil Greenberg; Michael L. Main; Michael S. Firstenberg; Jill Odabashian; James D. Thomas
OBJECTIVES To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.
Journal of the American College of Cardiology | 1996
M. John Williams; Jill Odabashian; Michael S. Lauer; James D. Thomas; Thomas H. Marwick
OBJECTIVES This study sought to establish the prognostic implications of ischemic and viable myocardium identified by dobutamine echocardiography in patients with left ventricular dysfunction. BACKGROUND Recent studies have suggested that in patients with viable myocardium identified by positron emission tomography, medical treatment is associated with recurrent cardiac events. Dobutamine echocardiography has been used to identify viable myocardium in patients with left ventricular dysfunction, but the prognostic significance of this test is undefined. METHODS One hundred thirty-six consecutive patients (mean [+/- SD] age 67 +/- 7.9 years; 104 men) with moderate or severe left ventricular dysfunction (left ventricular ejection fraction 30 +/- 5%) undergoing dobutamine echocardiography were included in the study. Dobutamine was administered using a standard incremental protocol (5 to 40 micrograms/kg body weight per min intravenously in 3-min stages) with additional atropine (1 mg intravenously) as required. Standard body weight echocardiographic views were digitized on-line and compared using a side-by-side display. Viable myocardium was identified by enhancement of regional function at low dose (< 10 micrograms); scar was diagnosed by akinesia at rest or dyskinesia without change and ischemia as new or worsening dysfunction. One hundred thirty patients (95%) were followed up for 16 +/- 8 months after the original study for major cardiac events (cardiac death, myocardial infarction or severe unstable angina requiring late myocardial revascularization). RESULTS No significant complications occurred during dobutamine echocardiography. Viable myocardium was detected in 26 patients (19%), ischemia in 23 (17%), both viability and ischemia in 13 (10%) and scar in 74 (54%). Of 108 patients treated medically, 46 had viable or ischemic myocardium, and 62 had scar only. There were no significant differences in age or other clinical characteristics, stress response, left ventricular dimensions and ejection fraction between the two groups. Cardiac events occurred in 26 medically treated patients (24%): 18 died of cardiac-related causes; 4 had a nonfatal myocardial infarction; and 4 had late revascularization because of unstable angina. The event rate was greater in patients with viable or ischemic myocardium than those with scar (43% vs. 8%, p = 0.01 by log-rank test). In a Cox regression model, the presence of viable or ischemic myocardium was found to predict subsequent events (relative risk 3.51, p = 0.02) independently of ejection fraction and age. CONCLUSIONS Viable or ischemic myocardium detected at dobutamine echocardiography in patients with left ventricular dysfunction is associated with an adverse prognosis, independent of age and ejection fraction.
Journal of the American College of Cardiology | 2000
Jian Xin Qin; Michael Jones; Takahiro Shiota; Neil L. Greenberg; Hiroyuki Tsujino; Michael S. Firstenberg; P.C. Gupta; Arthur D. Zetts; Yong Xu; Jing Ping Sun; Lisa A. Cardon; Jill Odabashian; Scott D. Flamm; Richard D. White; Julio A. Panza; James D. Thomas
OBJECTIVES To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpsons rule and apical biplane Simpsons rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7 ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes.
Echocardiography-a Journal of Cardiovascular Ultrasound and Allied Techniques | 2002
Irmien Vlassak; David N. Rubin; Jill Odabashian; Mario J. Garcia; Lisa M. King; Steve S. Lin; Jeanne K. Drinko; Annitta J. Morehead; David L. Prior; Craig R. Asher; Allan L. Klein; James D. Thomas
Background: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall‐motion analysis. Interpretation of dobutamine stress echocardiography is observer‐dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. Methods and Results: Twenty‐nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5–3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. Conclusion: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.
American Journal of Cardiology | 1999
Michael L. Main; Craig R. Asher; David N. Rubin; Jill Odabashian; Lisa A. Cardon; James D. Thomas; Allan L. Klein
Endocardial resolution during 2-dimensional echocardiography is technically limited in at least 10% to 15% of patients. Recently, several ultrasound imaging innovations have been introduced that may improve endocardial resolution and decrease the proportion of technically difficult studies. This study compares tissue harmonic imaging, intravenous sonicated albumin, and Doppler myocardial imaging in patients with technically difficult echocardiograms. Twenty-eight patients with known or suspected cardiac disease and poor baseline endocardial resolution were studied. Only harmonic imaging (conventional and optimized for tissue) was superior to baseline fundamental imaging (p <0.001). Harmonic imaging was superior to baseline imaging in all myocardial regions and in the majority of patients, including those with the worst baseline studies.
American Journal of Cardiology | 2000
Fatih Yalçin; Takahiro Shiota; Jill Odabashian; Debbie Agler; Neil L. Greenberg; Mario J. Garcia; Harry M. Lever; James D. Thomas
The data from the present nonrandomized observational study of 350 older persons with chronic atrial fibrillation showed that compared with aspirin, warfarin administered in a dose to maintain an INR between 2.0 and 3.0 caused a 40% significant reduction in thromboembolic stroke in persons with prior stroke, a 31% significant decrease in thromboembolic stroke in persons with no prior stroke, a 45% significant reduction in thromboembolic stroke in persons with abnormal LV ejection fraction, and a 36% significant decrease in thromboembolic stroke in persons with normal LV ejection fraction. Cox regression analysis showed that the use of warfarin in this study was a significant independent risk factor for reducing new thromboembolic stroke by 67%.
American Journal of Cardiology | 2000
Maran Thamilarasan; Richard A. Grimm; L. Leonardo Rodriguez; Jing Ping Sun; Jill Odabashian; Annitta Morehead; Mina K. Chung; Allan L. Klein; James D. Thomas
In this study, we sought evidence for an underlying atrial or ventricular myopathy in patients with paroxysmal lone atrial fibrillation using standard echocardiographic parameters in addition to Doppler tissue imaging of mitral annular motion. No impairment in atrial contractile function was found, but there was evidence for impaired diastolic function in these patients.
Circulation | 2002
Neil L. Greenberg; Michael S. Firstenberg; Peter L. Castro; Michael L. Main; Agnese Travaglini; Jill Odabashian; Jeanne K. Drinko; L. Leonardo Rodriguez; James D. Thomas; Mario J. Garcia
Journal of Applied Physiology | 2001
Michael S. Firstenberg; Neil L. Greenberg; Michael L. Main; Jeanne K. Drinko; Jill Odabashian; James D. Thomas; Mario J. Garcia
Journal of The American Society of Echocardiography | 2002
Hirotsugu Yamada; Ping Ping Goh; Jing Ping Sun; Jill Odabashian; Mario J. Garcia; James D. Thomas; Allan L. Klein