Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Jo-Yu Chin is active.

Publication


Featured researches published by Jo-Yu Chin.


Indoor Air | 2012

Particulate matter concentrations in residences: an intervention study evaluating stand‐alone filters and air conditioners

Stuart Batterman; Liuliu Du; Graciela Mentz; B. Mukherjee; Edith A. Parker; Christopher Godwin; Jo-Yu Chin; Ashley O'Toole; Thomas G. Robins; Z. Rowe; Toby C. Lewis

UNLABELLED This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the childs sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the childs bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84±27%, but dropped to 63±33% in subsequent seasons. In months when households were not visited, use averaged only 34±30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. PRACTICAL IMPLICATIONS Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 μg/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and thus strategies are needed to encourage and maintain use of filters. The variability in filter use suggests that exposure misclassification is a potential problem in intervention studies using filters. The installation of a room AC in the bedroom, intended to limit air exchange ratios, along with an air filter, did not lower PM levels more than the filter alone.


Indoor Air | 2014

Levels and sources of volatile organic compounds in homes of children with asthma

Jo-Yu Chin; Christopher Godwin; Edith A. Parker; Thomas G. Robins; Toby C. Lewis; Paul Harbin; Stuart Batterman

UNLABELLED Many volatile organic compounds (VOCs) are classified as known or possible carcinogens, irritants, and toxicants, and VOC exposure has been associated with the onset and exacerbation of asthma. This study characterizes VOC levels in 126 homes of children with asthma in Detroit, Michigan, USA. The total target VOC concentration ranged from 14 to 2274 μg/m(3) (mean = 150 μg/m(3); median = 91 μg/m(3)); 56 VOCs were quantified; and d-limonene, toluene, p, m-xylene, and ethyl acetate had the highest concentrations. Based on the potential for adverse health effects, priority VOCs included naphthalene, benzene, 1,4-dichlorobenzene, isopropylbenzene, ethylbenzene, styrene, chloroform, 1,2-dichloroethane, tetrachloroethene, and trichloroethylene. Concentrations varied mostly due to between-residence and seasonal variation. Identified emission sources included cigarette smoking, solvent-related emissions, renovations, household products, and pesticides. The effect of nearby traffic on indoor VOC levels was not distinguished. While concentrations in the Detroit homes were lower than levels found in other North American studies, many homes had elevated VOC levels, including compounds that are known health hazards. Thus, the identification and control of VOC sources are important and prudent, especially for vulnerable individuals. Actions and policies to reduce VOC exposures, for example, sales restrictions, improved product labeling, and consumer education, are recommended. PRACTICAL IMPLICATIONS Total target VOC concentrations in the Detroit homes ranged from 14 to 2274 lg/m3, generally lower than found in earlier studies. However, a subset of houses had elevated concentrations, and levels of 1,4-dichlorobenzene, naphthalene, and benzene reached levels commensurate with excess individual cancer risks of 10(-2), 10(-3), and 10(-4), respectively. VOC concentrations varied mostly due to between-residence and season effects. The most important sources included cigarette smoking, vehicle-related emissions, building renovation, solvents, household products, and pesticides.


Indoor Air | 2012

Sources, concentrations, and risks of naphthalene in indoor and outdoor air

Stuart Batterman; Jo-Yu Chin; Chunrong Jia; Christopher Godwin; Edith A. Parker; Thomas G. Robins; Paul Max; Toby C. Lewis

UNLABELLED Naphthalene is a ubiquitous pollutant, and very high concentrations are sometimes encountered indoors when this chemical is used as a pest repellent or deodorant. This study describes the distribution and sources of vapor-phase naphthalene concentrations in four communities in southeast Michigan, USA. Outdoors, naphthalene was measured in the communities and at a near-road site. Indoors, naphthalene levels were characterized in 288 suburban and urban homes. The median outdoor concentration was 0.15 μg/m(3), and a modest contribution from rush-hour traffic was noted. The median indoor long-term concentration was 0.89 μg/m(3), but concentrations were extremely skewed and 14% of homes exceeded 3 μg/m(3), the chronic reference concentration for non-cancer effects, 8% exceeded 10 μg/m(3), and levels reached 200 μg/m(3). The typical excess individual lifetime cancer risk was about 10(-4) and reached 10(-2) in some homes. Important sources include naphthalenes use as a pest repellent and deodorant, migration from attached garages and, to lesser extents, cigarette smoke and vehicle emissions. Excessive use as a repellent caused the highest concentrations. Naphthalene presents high risks in a subset of homes, and policies and actions to reduce exposures, for example, sales bans or restrictions, improved labeling, and consumer education, should be considered. PRACTICAL IMPLICATIONS Long-term average concentrations of naphthalene in most homes fell into the 0.2-1.7 μg/m(3) range reported as representative in earlier studies. The highly skewed distribution of concentrations results in a subset of homes with elevated concentrations and health risks that greatly exceed US EPA and World Health Organization (WHO) guidelines. The most important indoor source is the use of naphthalene as a pest repellant or deodorant; secondary sources include presence of an attached garage, cigarette smoking, and outdoor sources. House-to-house variation was large, reflecting differences among the residences and naphthalene use practices. Stronger policies and educational efforts are needed to eliminate or modify indoor usage practices of this chemical.


Chemosphere | 2012

VOC composition of current motor vehicle fuels and vapors, and collinearity analyses for receptor modeling

Jo-Yu Chin; Stuart Batterman

The formulation of motor vehicle fuels can alter the magnitude and composition of evaporative and exhaust emissions occurring throughout the fuel cycle. Information regarding the volatile organic compound (VOC) composition of motor fuels other than gasoline is scarce, especially for bioethanol and biodiesel blends. This study examines the liquid and vapor (headspace) composition of four contemporary and commercially available fuels: gasoline (<10% ethanol), E85 (85% ethanol and 15% gasoline), ultra-low sulfur diesel (ULSD), and B20 (20% soy-biodiesel and 80% ULSD). The composition of gasoline and E85 in both neat fuel and headspace vapor was dominated by aromatics and n-heptane. Despite its low gasoline content, E85 vapor contained higher concentrations of several VOCs than those in gasoline vapor, likely due to adjustments in its formulation. Temperature changes produced greater changes in the partial pressures of 17 VOCs in E85 than in gasoline, and large shifts in the VOC composition. B20 and ULSD were dominated by C(9) to C(16)n-alkanes and low levels of the aromatics, and the two fuels had similar headspace vapor composition and concentrations. While the headspace composition predicted using vapor-liquid equilibrium theory was closely correlated to measurements, E85 vapor concentrations were underpredicted. Based on variance decomposition analyses, gasoline and diesel fuels and their vapors VOC were distinct, but B20 and ULSD fuels and vapors were highly collinear. These results can be used to estimate fuel related emissions and exposures, particularly in receptor models that apportion emission sources, and the collinearity analysis suggests that gasoline- and diesel-related emissions can be distinguished.


International Journal of Environmental Research and Public Health | 2012

Air Change Rates and Interzonal Flows in Residences, and the Need for Multi-Zone Models for Exposure and Health Analyses

Liuliu Du; Stuart Batterman; Christopher Godwin; Jo-Yu Chin; Edith A. Parker; Michael S. Breen; Wilma Brakefield; Thomas G. Robins; Toby C. Lewis

Air change rates (ACRs) and interzonal flows are key determinants of indoor air quality (IAQ) and building energy use. This paper characterizes ACRs and interzonal flows in 126 houses, and evaluates effects of these parameters on IAQ. ACRs measured using weeklong tracer measurements in several seasons averaged 0.73 ± 0.76 h−1 (median = 0.57 h−1, n = 263) in the general living area, and much higher, 1.66 ± 1.50 h−1 (median = 1.23 h−1, n = 253) in bedrooms. Living area ACRs were highest in winter and lowest in spring; bedroom ACRs were highest in summer and lowest in spring. Bedrooms received an average of 55 ± 18% of air from elsewhere in the house; the living area received only 26 ± 20% from the bedroom. Interzonal flows did not depend on season, indoor smoking or the presence of air conditioners. A two-zone IAQ model calibrated for the field study showed large differences in pollutant levels between the living area and bedroom, and the key parameters affecting IAQ were emission rates, emission source locations, air filter use, ACRs, interzonal flows, outdoor concentrations, and PM penetration factors. The single-zone models that are commonly used for residences have substantial limitations and may inadequately represent pollutant concentrations and exposures in bedrooms and potentially other environments other where people spend a substantial fraction of time.


Indoor Air | 2013

Concentrations and Risks of p-Dichlorobenzene in Indoor and Outdoor Air

Jo-Yu Chin; Christopher Godwin; Chunrong Jia; Thomas G. Robins; Toby C. Lewis; Edith A. Parker; Paul Max; Stuart Batterman

UNLABELLED p-dichlorobenzene (PDCB) is a chlorinated volatile organic compound that can be encountered at high concentrations in buildings owing to its use as pest repellent and deodorant. This study characterizes PDCB concentrations in four communities in southeast Michigan. The median concentration outside 145 homes was 0.04 μg/m(3), and the median concentration inside 287 homes was 0.36 μg/m(3). The distribution of indoor concentrations was extremely skewed. For example, 30% of the homes exceeded 0.91 μg/m(3), which corresponds to a cancer risk level of 10(-5) based on the California unit risk estimate, and 4% of homes exceeded 91 μg/m(3), equivalent to a 10(-3) risk level. The single highest measurement was 4100 μg/m(3). Estimates of whole-house emission rates were largely consistent with chamber test results in the literature. Indoor concentrations that exceed a few μg/m(3) indicate the use of PDCB products. PDCB concentrations differed among households and the four cities, suggesting the importance of locational, cultural, and behavioral factors in the use patterns of this chemical. The high PDCB levels found suggest the need for policies and actions to lower exposures, for example, sales or use restrictions, improved labeling, and consumer education. PRACTICAL IMPLICATIONS Distributions of p-dichlorobenzene concentrations in residences are highly right-skewed, and a subset of houses has very elevated concentrations that are equivalent to an excess cancer risk of 10(-3) or higher based on the California unit risk effect estimate. House-to-house variation is large, reflecting differences in use practices. Stronger policies and educational efforts are needed to eliminate or modify indoor usage practices of this chemical.


Journal of Occupational and Environmental Hygiene | 2010

Permeation of Gasoline, Diesel, Bioethanol (E85), and Biodiesel (B20) Fuels Through Six Glove Materials

Jo-Yu Chin; Stuart Batterman

Biofuels and conventional fuels differ in terms of their evaporation rates, permeation rates, and exhaust emissions, which can alter exposures of workers, especially those in the fuel refining and distribution industries. This study investigated the permeation of biofuels (bioethanol 85%, biodiesel 20%) and conventional petroleum fuels (gasoline and diesel) through gloves used in occupational settings (neoprene, nitrile, and Viton) and laboratories (latex, nitrile, and vinyl), as well as a standard reference material (neoprene sheet). Permeation rates and breakthrough times were measured using the American Society for Testing and Materials F739-99 protocol, and fuel and permeant compositions were measured by gas chromatography/mass spectrometry. In addition, we estimated exposures for three occupational scenarios and recommend chemical protective clothing suitable for use with motor fuels. Permeation rates and breakthrough times depended on the fuel-glove combination. Gasoline had the highest permeation rate among the four fuels. Bioethanol (85%) had breakthrough times that were two to three times longer than gasoline through neoprene, nitrile Sol-Vex, and the standard reference materials. Breakthrough times for biodiesel (20%) were slightly shorter than for diesel for the latex, vinyl, nitrile examination, and the standard neoprene materials. The composition of permeants differed from neat fuels, e.g., permeants were significantly enriched in the lighter aromatics including benzene. Viton was the best choice among the tested materials for the four fuels tested. Among the scenarios, fuel truck drivers had the highest uptake via inhalation based on the personal measurements available in the literature, and gasoline station attendants had highest uptake via dermal exposure if gloves were not worn. Appropriate selection and use of gloves can protect workers from dermal exposures; however, current recommendations from the National Institute for Occupational Safety and Health should be revised to account for contemporary fuel formulations that routinely contain ethanol.


Indoor Air | 2010

Sources and migration of volatile organic compounds in mixed-use buildings

Chunrong Jia; Stuart Batterman; Christopher Godwin; Simone M. Charles; Jo-Yu Chin


Fuel and Energy Abstracts | 2011

Particle concentrations and effectiveness of free-standing air filters in bedrooms of children with

Liuliu Du; Stuart Batterman; Edith A. Parker; Christopher Godwin; Jo-Yu Chin; Ashley O'Toole; Thomas G. Robins; Wilma Brakefield-Caldwell; Toby C. Lewis


Indoor Air | 2010

Sources and Migration of VOCs in Mixed- Use Buildings

Chunrong Jia; Christopher Godwin; Stuart Batterman; Simone M. Charles; Jo-Yu Chin

Collaboration


Dive into the Jo-Yu Chin's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Simone M. Charles

Georgia Southern University

View shared research outputs
Top Co-Authors

Avatar

Liuliu Du

University of Michigan

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge