Network


Latest external collaboration on country level. Dive into details by clicking on the dots.

Hotspot


Dive into the research topics where Joakim Jonsson is active.

Publication


Featured researches published by Joakim Jonsson.


Radiation Oncology | 2010

Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions

Joakim Jonsson; Magnus Karlsson; Mikael Karlsson; Tufve Nyholm

BackgroundBecause of superior soft tissue contrast, the use of magnetic resonance imaging (MRI) as a complement to computed tomography (CT) in the target definition procedure for radiotherapy is increasing. To keep the workflow simple and cost effective and to reduce patient dose, it is natural to strive for a treatment planning procedure based entirely on MRI. In the present study, we investigate the dose calculation accuracy for different treatment regions when using bulk density assignments on MRI data and compare it to treatment planning that uses CT data.MethodsMR and CT data were collected retrospectively for 40 patients with prostate, lung, head and neck, or brain cancers. Comparisons were made between calculations on CT data with and without inhomogeneity corrections and on MRI or CT data with bulk density assignments. The bulk densities were assigned using manual segmentation of tissue, bone, lung, and air cavities.ResultsThe deviations between calculations on CT data with inhomogeneity correction and on bulk density assigned MR data were small. The maximum difference in the number of monitor units required to reach the prescribed dose was 1.6%. This result also includes effects of possible geometrical distortions.ConclusionsThe dose calculation accuracy at the investigated treatment sites is not significantly compromised when using MRI data when adequate bulk density assignments are made. With respect to treatment planning, MRI can replace CT in all steps of the treatment workflow, reducing the radiation exposure to the patient, removing any systematic registration errors that may occur when combining MR and CT, and decreasing time and cost for the extra CT investigation.


Medical Physics | 2015

Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm.

Carl Siversson; Fredrik Nordström; Terese Nilsson; Tufve Nyholm; Joakim Jonsson; Adalsteinn Gunnlaugsson; Lars E. Olsson

PURPOSE In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region. METHODS The study comprised ten prostate cancer patients, for whom a 3D T2 weighted MRI and a conventional planning CT were acquired. For each patient, sCT images were generated from the acquired MRI using the SDA. In order to decouple the effect of variations in patient geometry between imaging modalities from the effect of uncertainties in the SDA, the conventional CT was nonrigidly registered to the MRI to assure that their geometries were well aligned. For each patient, a volumetric modulated arc therapy plan was created for the registered CT (rCT) and recalculated for both the sCT and the conventional CT. The results were evaluated using several methods, including mean average error (MAE), a set of dose-volume histogram parameters, and a restrictive gamma criterion (2% local dose/1 mm). RESULTS The MAE within the body contour was 36.5 ± 4.1 (1 s.d.) HU between sCT and rCT. Average mean absorbed dose difference to target was 0.0% ± 0.2% (1 s.d.) between sCT and rCT, whereas it was -0.3% ± 0.3% (1 s.d.) between CT and rCT. The average gamma pass rate was 99.9% for sCT vs rCT, whereas it was 90.3% for CT vs rCT. CONCLUSIONS The SDA enables a highly accurate MRI only workflow in prostate radiotherapy planning. The dosimetric uncertainties originating from the SDA appear negligible and are notably lower than the uncertainties introduced by variations in patient geometry between imaging sessions.


Seminars in Radiation Oncology | 2014

Counterpoint: Opportunities and Challenges of a Magnetic Resonance Imaging–Only Radiotherapy Work Flow

Tufve Nyholm; Joakim Jonsson

Magnetic resonance (MR) imaging plays an important role in modern radiotherapy. The benefits of MR as compared with those of computed tomography for the definition of target volumes is evident for many soft tissue tumor types. It has been suggested that for these patient groups, the computed tomography examination is unnecessary as part of the preparation for radiotherapy. Here, we review the rationale for an MR-only radiotherapy work flow, as well as the technical challenges and solutions connected to it.


Radiotherapy and Oncology | 2013

Treatment planning of intracranial targets on MRI derived substitute CT data

Joakim Jonsson; Adam Johansson; Karin Söderström; Thomas Asklund; Tufve Nyholm

BACKGROUND The use of magnetic resonance imaging (MRI) as a complement to computed tomography (CT) in the target definition procedure for radiotherapy is increasing. To eliminate systematic uncertainties due to image registration, a workflow based entirely on MRI may be preferable. In the present pilot study, we investigate dose calculation accuracy for automatically generated substitute CT (s-CT) images of the head based on MRI. We also produce digitally reconstructed radiographs (DRRs) from s-CT data to evaluate the feasibility of patient positioning based on MR images. METHODS AND MATERIALS Five patients were included in the study. The dose calculation was performed on CT, s-CT, s-CT data without inhomogeneity correction and bulk density assigned MRI images. Evaluation of the results was performed using point dose and dose volume histogram (DVH) comparisons, and gamma index evaluation. RESULTS The results demonstrate that the s-CT images improve the dose calculation accuracy compared to the method of non-inhomogeneity corrected dose calculations (mean improvement 2.0% points) and that it performs almost identically to the method of bulk density assignment. The s-CT based DRRs appear to be adequate for patient positioning of intra-cranial targets, although further investigation is needed on this subject. CONCLUSION The s-CT method is very fast and yields data that can be used for treatment planning without sacrificing accuracy.


International Journal of Radiation Oncology Biology Physics | 2012

INTERNAL FIDUCIAL MARKERS AND SUSCEPTIBILITY EFFECTS IN MRI—SIMULATION AND MEASUREMENT OF SPATIAL ACCURACY

Joakim Jonsson; Anders Garpebring; Magnus Karlsson; Tufve Nyholm

BACKGROUND It is well-known that magnetic resonance imaging (MRI) is preferable to computed tomography (CT) in radiotherapy target delineation. To benefit from this, there are two options available: transferring the MRI delineated target volume to the planning CT or performing the treatment planning directly on the MRI study. A precondition for excluding the CT study is the possibility to define internal structures visible on both the planning MRI and on the images used to position the patient at treatment. In prostate cancer radiotherapy, internal gold markers are commonly used, and they are visible on CT, MRI, x-ray, and portal images. The depiction of the markers in MRI are, however, dependent on their shape and orientation relative the main magnetic field because of susceptibility effects. In the present work, these effects are investigated and quantified using both simulations and phantom measurements. METHODS AND MATERIALS Software that simulated the magnetic field distortions around user defined geometries of variable susceptibilities was constructed. These magnetic field perturbation maps were then reconstructed to images that were evaluated. The simulation software was validated through phantom measurements of four commercially available gold markers of different shapes and one in-house gold marker. RESULTS Both simulations and phantom measurements revealed small position deviations of the imaged marker positions relative the actual marker positions (<1 mm). CONCLUSION Cylindrical gold markers can be used as internal fiducial markers in MRI.


Radiation Oncology | 2011

Registration accuracy for MR images of the prostate using a subvolume based registration protocol

Joakim Jonsson; Patrik Brynolfsson; Anders Garpebring; Mikael Karlsson; Karin Söderström; Tufve Nyholm

BackgroundIn recent years, there has been a considerable research effort concerning the integration of magnetic resonance imaging (MRI) into the external radiotherapy workflow motivated by the superior soft tissue contrast as compared to computed tomography. Image registration is a necessary step in many applications, e.g. in patient positioning and therapy response assessment with repeated imaging. In this study, we investigate the dependence between the registration accuracy and the size of the registration volume for a subvolume based rigid registration protocol for MR images of the prostate.MethodsTen patients were imaged four times each over the course of radiotherapy treatment using a T2 weighted sequence. The images were registered to each other using a mean square distance metric and a step gradient optimizer for registration volumes of different sizes. The precision of the registrations was evaluated using the center of mass distance between the manually defined prostates in the registered images. The optimal size of the registration volume was determined by minimizing the standard deviation of these distances.ResultsWe found that prostate position was most uncertain in the anterior-posterior (AP) direction using traditional full volume registration. The improvement in standard deviation of the mean center of mass distance between the prostate volumes using a registration volume optimized to the prostate was 3.9 mm (p < 0.001) in the AP direction. The optimum registration volume size was 0 mm margin added to the prostate gland as outlined in the first image series.ConclusionsRepeated MR imaging of the prostate for therapy set-up or therapy assessment will both require high precision tissue registration. With a subvolume based registration the prostate registration uncertainty can be reduced down to the order of 1 mm (1 SD) compared to several millimeters for registration based on the whole pelvis.


Medical Physics | 2018

MR and CT data with multiobserver delineations of organs in the pelvic area—Part of the Gold Atlas project

Tufve Nyholm; Stina Svensson; Sebastian Andersson; Joakim Jonsson; Maja Sohlin; Christian Gustafsson; Elisabeth Kjellén; Karin Söderström; Per Albertsson; Lennart Blomqvist; Björn Zackrisson; Lars E. Olsson; Adalsteinn Gunnlaugsson

PURPOSE We describe a public dataset with MR and CT images of patients performed in the same position with both multiobserver and expert consensus delineations of relevant organs in the male pelvic region. The purpose was to provide means for training and validation of segmentation algorithms and methods to convert MR to CT like data, i.e., so called synthetic CT (sCT). ACQUISITION AND VALIDATION METHODS T1- and T2-weighted MR images as well as CT data were collected for 19 patients at three different departments. Five experts delineated nine organs for each patient based on the T2-weighted MR images. An automatic method was used to fuse the delineations. Starting from each fused delineation, a consensus delineation was agreed upon by the five experts for each organ and patient. Segmentation overlap between user delineations with respect to the consensus delineations was measured to describe the spread of the collected data. Finally, an open-source software was used to create deformation vector fields describing the relation between MR and CT images to further increase the usability of the dataset. DATA FORMAT AND USAGE NOTES The dataset has been made publically available to be used for academic purposes, and can be accessed from https://zenodo.org/record/583096. POTENTIAL APPLICATIONS The dataset provides a useful source for training and validation of segmentation algorithms as well as methods to convert MR to CT-like data (sCT). To give some examples: The T2-weighted MR images with their consensus delineations can directly be used as a template in an existing atlas-based segmentation engine; the expert delineations are useful to validate the performance of a segmentation algorithm as they provide a way to measure variability among users which can be compared with the result of an automatic segmentation; and the pairwise deformably registered MR and CT images can be a source for an atlas-based sCT algorithm or for validation of sCT algorithm.


Magnetic Resonance in Medicine | 2018

Zero TE-based pseudo-CT image conversion in the head and its application in PET/MR attenuation correction and MR-guided radiation therapy planning

Florian Wiesinger; Mikael Bylund; Jaewon Yang; Sandeep Suryanarayana Kaushik; Dattesh Shanbhag; Sangtae Ahn; Joakim Jonsson; Josef A. Lundman; Thomas A. Hope; Tufve Nyholm; Peder E. Z. Larson; Cristina Cozzini

To describe a method for converting Zero TE (ZTE) MR images into X‐ray attenuation information in the form of pseudo‐CT images and demonstrate its performance for (1) attenuation correction (AC) in PET/MR and (2) dose planning in MR‐guided radiation therapy planning (RTP).


European urology focus | 2017

Imaging for the Detection of Locoregional Recurrences in Biochemical Progression After Radical Prostatectomy—A Systematic Review

Kristina Sandgren; Philippe Westerlinck; Joakim Jonsson; Lennart Blomqvist; Camilla Thellenberg Karlsson; Tufve Nyholm; P. Dirix

CONTEXT Local and regional recurrence after radical prostatectomy (RP) can be treated using salvage radiotherapy (SRT). If the recurrence can be delineated on diagnostic imaging, this could allow for increasingly individualized SRT. OBJECTIVE This systematic review aimed at evaluating the evidence regarding the usefulness of positron emission tomography (PET) and magnetic resonance imaging (MRI) in identifying local and regional recurrences, with the aim to further individualize the SRT treatment. EVIDENCE ACQUISITION A systematic PubMed/Medline search was conducted in December 2015. Studies included were imaging studies of post-RP patients focusing on local and/or regional recurrence where sensitivity and specificity of MRI or PET were the primary end points. Only studies using biopsy, other histological analysis, and/or treatment follow-up as reference standard were included. Quality Assessment of Diagnostic Accuracy Studies-2 was used to score the study quality. Twenty-five articles were deemed of sufficient quality and included in the review. EVIDENCE SYNTHESIS [11C]Acetate had the highest pooled sensitivity (92%), while [11C]choline and [18F]choline had pooled sensitivities of 71% and 84%, respectively. The PET tracer with highest pooled specificity was [11C]choline (86%). Regarding MRI, MR spectroscopy combined with dynamic contrast enhanced (DCE) MRI showed the highest pooled sensitivity (89%). High pooled sensitivities were also seen using multiparametric MRI (84%), diffusion-weighted MRI combined with T2-weigthed (T2w) imaging (82%), and DCE MRI combined with T2w imaging (82%). These also showed high pooled specificities (85%, 89%, and 92%, respectively). CONCLUSIONS Both MRI and PET have adequate sensitivity and specificity for the detection of prostate cancer recurrences post-RP. Multiparametric MRI, using diffusion-weighted and/or DCE imaging, and the choline-labeled tracers showed high pooled sensitivity and specificity, although their ranges were broad. PATIENT SUMMARY After reviewing imaging studies of recurrent prostate cancer after prostatectomy, we concluded that choline positron emission tomography and diffusion-weighted magnetic resonance imaging can be proposed as the current standard, with high sensitivity and specificity.


Medical Physics | 2018

Technical Note: Adapting a GE SIGNA PET/MR scanner for radiotherapy

Patrik Brynolfsson; Jan Axelsson; August Holmberg; Joakim Jonsson; David Goldhaber; Yiqiang Jian; Fredrik Illerstam; Mathias Engström; Björn Zackrisson; Tufve Nyholm

PURPOSE Simultaneous collection of PET and MR data for radiotherapy purposes are useful for, for example, target definition and dose escalations. However, a prerequisite for using PET/MR in the radiotherapy workflow is the ability to image the patient in treatment position. The aim of this work was to adapt a GE SIGNA PET/MR scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (SNR) of the MR images, and the accuracy of the PET attenuation correction. METHOD A flat tabletop and a coil holder were developed to image patients in the treatment position, avoid patient contour deformation, and facilitate attenuation correction of flex coils. Attenuation corrections for the developed hardware and an anterior array flex coil were also measured and implemented to the PET/MR system to minimize PET quantitation errors. The reduction of SNR in the MR images due to the added distance between the coils and the patient was evaluated using a large homogenous saline-doped water phantom, and the activity quantitation errors in PET imaging were evaluated with and without the developed attenuation corrections. RESULT We showed that the activity quantitation errors in PET imaging were within ±5% when correcting for attenuation of the flat tabletop, coil holder, and flex coil. The SNR of the MRI images were reduced to 74% using the tabletop, and 66% using the tabletop and coil holders. CONCLUSION We present a tabletop and coil holder for an anterior array coil to be used with a GE SIGNA PET/MR scanner, for scanning patients in the radiotherapy work flow. Implementing attenuation correction of the added hardware from the radiotherapy setup leads to acceptable PET image quantitation. The drop in SNR in MR images may require adjustment of the imaging protocols.

Collaboration


Dive into the Joakim Jonsson's collaboration.

Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar

Lennart Blomqvist

Karolinska University Hospital

View shared research outputs
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Top Co-Authors

Avatar
Researchain Logo
Decentralizing Knowledge