Joan Montanyà
Polytechnic University of Catalonia
Network
Latest external collaboration on country level. Dive into details by clicking on the dots.
Publication
Featured researches published by Joan Montanyà.
Journal of Geophysical Research | 2014
Joan Montanyà; Oscar van der Velde; Earle R. Williams
New observations with a 3-D Lightning Mapping Array and high-speed video are presented and discussed. The first set of observations shows that under certain thunderstorm conditions, wind turbine blades can produce electric discharges at regular intervals of ~3 s in relation to its rotation, over periods of time that range from a few minutes up to hours. This periodic effect has not been observed in static towers indicating that the effect of rotation is playing a critical role. The repeated discharges can occur tens of kilometers away from electrically active thunderstorm areas and may or may not precede a fully developed upward lightning discharge from the turbine. Similar to rockets used for triggering lightning, the fast movement of the blade tip plays an important role on the initiation of the discharge. The movement of the rotor blades allows the tip to “runaway” from the generated corona charge. The second observation is an uncommon upward/downward flash triggered by a wind turbine. In that flash, a negative upward leader was initiated from a wind turbine without preceding lightning activity. The flash produced a negative cloud-to-ground stroke several kilometers from the initiation point. The third observation corresponds to a high-speed video record showing simultaneous upward positive leaders from a group of wind turbines triggered by a preceding intracloud flash. The fact that multiple leaders develop simultaneously indicates a poor shielding effect among them. All these observations provide some special features on the initiation of lightning by nonstatic and complex tall structures.
Journal of Geophysical Research | 2011
Serge Soula; Oscar van der Velde; Joan Montanyà; Patrice Huet; Christelle Barthe; József Bór
Five gigantic jets (GJs) have been recorded with video and photograph cameras on 7 March 2010 above an isolated tropical storm east of Reunion Island. Three of them were produced before the storm reached its coldest cloud top temperature (approximately −81°C), and two others occurred during the cloud extension. Thanks to the close distance of observation (∼50 km), the luminosity within the cloud was recorded, and the events are analyzed in unprecedented detail. The tops of the GJs are estimated between 80 and 90 km. All these GJs are accompanied by long, continuous cloud illumination, and they are preceded and followed by intermittent optical flashes from the cloud, most of time without any cloud-to-ground (CG) flash simultaneously detected, which suggests they originated mainly as intracloud discharges and without any charge transfer to Earth. The CG lightning activity is observed to cease a few tens of seconds before the jets. According to ELF data recorded at Nagycenk, Hungary, the five GJs serve to raise negative charge. Their duration ranges from 333 to 850 ms. The leading jet has the most variable duration (33-167 ms) and propagates faster at higher altitudes. The trailing jet exhibits a continuous decrease of luminosity in different parts of the jet (lower channel, transition zone and, for most events, carrot sprite-like top) and in the cloud, with possible rebrightening. The lower channels (∼20-40 km altitude) produce blue luminosity which decreases with altitude and become more and more diffuse with time. The transition zone (around 40-65 km) consists of bright red, luminous beads slowly going up (∼104 m s−1), retracing the initial leading jet channels.
Journal of Geophysical Research | 2010
Joan Montanyà; O. van der Velde; D. Romero; V. March; G. Solà; Nicolau Pineda; M. Arrayas; José L. Trueba; V. Reglero; S. Soula
We report the first intensified high‐speed video images of elves, sprites, and halos observed in Europe. All the events corresponded to winter season thunderstorms over the Mediterranean Sea. The observations comprise many elves generated by both cloud‐to‐ground lightning current polarities. In 8 of the 14 sprite observations we observed an elve previous to the sprite. In three cases we observed also an elve quickly followed by a halo and a sprite. In several observations we observed lightning light before the mesospheric transient luminous event. We present a case where the lightning from cloud tops was visible during the entire event. Thanks to the high‐speed videos and their resolution and low intensifier phosphor persistence we analyzed the timing distribution of the development phase of sprite elements, the persisting luminosity phase, and the total duration. Finally, we summarize one particular observation where a streamer collides and bounces with a previous formed column; it may be a new phenomenon of collision between an existing column body that interacts with a later streamer point‐like tip which is not merged and attached.
Journal of Geophysical Research | 2010
Serge Soula; O. van der Velde; J. Palmiéri; Olivier Chanrion; Torsten Neubert; Joan Montanyà; F. Gangneron; Yves Meyerfeld; F. Lefeuvre; G. Lointier
On the night of 15/16 November 2007, cameras in southern France detected 30 transient luminous events (TLEs) over a storm located in the Corsican region (France). Among these TLEs, 19 were sprites, 6 were halos, and 5 were elves. For 26 of them, a positive “parent” cloud‐to‐ground lightning (P+CG) flash was identified. The peak current of the P+CG flashes for the sprites had an average value of 63 kA and had a maximum value of 125 kA. The flashes for the halos and the elves had average values of 272 and 351 kA, respectively, and they had maximum values of 312 and 384 kA, respectively. No TLEs were detected after negative CG flashes with very large peak currents. Among the 26 P+CG flashes, 23 were located in a stratiform region with reflectivity values lower than 45 dBZ. The CG flashes in this region were classified into two groups according to the time interval separating them from the following flash: one group with values less than 2 s and one with values greater than 2 s. About 79% of all CGs were produced in a sequence of at least two flashes less than 2 s apart. For 65.5% of the sequences, the first flash was positive with an average peak current of 73 kA, while the later +CG flashes in a sequence had much lower peak currents. Several triangulated sprites were found to be shifted from their P+CG flashes by about 10 to 50 km and preferentially downstream. The observations suggest that the P+CG flashes can initiate both sprites and other CG flashes in a storm.
Journal of Geophysical Research | 2014
Oscar van der Velde; Joan Montanyà; Serge Soula; Nicolau Pineda; Janusz Mlynarczyk
Thirty-five sprite-producing lightning flashes were recorded in nine nights in different seasons at the east coast of Spain with a 3D Lightning Mapping Array (LMA) since July 2011. A low-frequency time-of-arrival network provided data on emissions from return strokes and intracloud processes and a very-high-frequency interferometer network produced complementary lightning data. This study analyzes the bidirectional development of flashes in order to understand the positioning and timing of the positive cloud-to-ground stroke (+CG) and its consequences for charge neutralization by negative leaders, affecting sprite morphology. A summary of negative leader extents, altitudes, and speeds before and after the + CG stroke is provided, as well as positive leader origins and inferred speeds. Negative leader speeds exhibited modes at 105 and 5 × 105 m s−1. Five examples with different evolutions are discussed: (1) Slow bidirectional development with negative leader termination before the + CG stroke; (2) Fast bidirectional development with the negative leader continuing after the + CG stroke. (3) Slow-fast bidirectional development with a negative leader exhibiting a sudden lowering and speed increase; (4) Fast secondary bidirectional development from an in-cloud horizontal positive leader. Negative leaders propagated rapidly into the upper positive charge layer, continuing after the + CG stroke; (5) Slow bidirectional development with a long negative leader (50 km) subject to cutoff while the original positive leader remained trapped inside negative charge. A + CG stroke subsequently occurred under the old negative leader channel. Carrot sprites tended to be associated with fast extending leaders after the stroke, columniform/mixed sprites with slower side branches.
Journal of Geophysical Research | 2015
Thomas Gjesteland; N. Østgaard; Sante Laviola; Mario Marcello Miglietta; E. Arnone; M. Marisaldi; Fabio Fuschino; Andrew B. Collier; Ferran Fabró; Joan Montanyà
Abstract We present three terrestrial gamma ray flashes (TGFs) observed over the Mediterranean basin by the Reuven Ramaty High Energy Solar Spectroscope Imager (RHESSI) satellite. Since the occurrence of these events in the Mediterranean region is quite rare, the characterization of the events was optimized by combining different approaches in order to better define the cloud of origin. The TGFs on 7 November 2004 and 16 October 2006 came from clouds with cloud top higher than 10–12 km where often a strong penetration into the stratosphere is found. This kind of cloud is usually associated with heavy precipitation and intense lightning activity. Nevertheless, the analysis of the cloud type based on satellite retrievals shows that the TGF on 27 May 2004 was produced by an unusual shallow convection. This result appears to be supported by the model simulation of the particle distribution and phase in the upper troposphere. The TGF on 7 November 2004 is among the brightest ever measured by RHESSI. The analysis of the energy spectrum of this event is consistent with a production altitude ≤12 km, which is in the upper part of the cloud, as found by the meteorological analysis of the TGF‐producing thunderstorm. This event must be unusually bright at the source in order to produce such a strong signal in RHESSI. We estimate that this TGF must contain ∼3 × 1018 initial photons with energy >1 MeV. This is 1 order of magnitude brighter than earlier estimations of an average RHESSI TGF.
Scientific Reports | 2015
Joan Montanyà; Oscar van der Velde; Earle R. Williams
Lightning flashes are known to initiate in regions of strong electric fields inside thunderstorms, between layers of positively and negatively charged precipitation particles. For that reason, lightning inception is typically hidden from sight of camera systems used in research. Other technology such as lightning mapping systems based on radio waves can typically detect only some aspects of the lightning initiation process and subsequent development of positive and negative leaders. We report here a serendipitous recording of bidirectional lightning initiation in virgin air under the cloud base at ~11,000 images per second, and the differences in characteristics of opposite polarity leader sections during the earliest stages of the discharge. This case reveals natural lightning initiation, propagation and a return stroke as in negative cloud-to-ground flashes, upon connection to another lightning channel – without any masking by cloud.
Archive | 2009
Nicolau Pineda; Joan Montanyà
This chapter reviews the lightning detection in Spain. It focuses on the region of Catalonia (NE Spain), which has the particularity of being covered by two different lightning detection systems. Since 1992, the Spanish Lightning Detection Network provides the location and characteristics of the cloud-to-ground lightning activity for the whole country. In 2003, an interferometric detection system was installed in Catalonia, providing total lightning data for this region. The performance of this system was evaluated using experimental field measurements. Afterwards, the chapter summarizes some aspects of the lightning climatology in Spain and Catalonia. Finally, in the particular case of Catalonia, other aspects are reviewed, like the convective precipitation and the lightning relationship, and the total lightning activity in hail episodes.
Journal of Geophysical Research | 2015
Serge Soula; Eric Defer; Martin Füllekrug; Oscar van der Velde; Joan Montanyà; Olivier Bousquet; Janusz Mlynarczyk; Sylvain Coquillat; Jean-Pierre Pinty; W. Rison; Paul Krehbiel; Ron Thomas; S. Pedeboy
During the night of 22–23 October 2012, together with the Hydrology cycle in the Mediterranean eXperiment (HyMeX) Special Observation Period 1 campaign, optical observations of sprite events were performed above a leading stratiform Mesoscale Convective System in southeastern France. The total lightning activity of the storm was monitored in three dimensions with the HyMeX Lightning Mapping Array. Broadband Extremely Low Frequency/Very Low Frequency records and radar observations allowed characterizing the flashes and the regions of the cloud where they propagated. Twelve sprite events occurred over the stratiform region, during the last third of the lightning activity period, and well after the coldest satellite-based cloud top temperature (−62°C) and the maximum total lightning flash rate (11 min−1). The sprite-producing positive cloud-to-ground (SP + CG) strokes exhibit peak current from 14 to 247 kA, Charge Moment Changes (CMC) from 625 to 3086 C km, and Impulsive CMC (iCMC) between 242 and 1525 C km. The +CG flashes that do not trigger sprites are initiated outside the main convective core, have much lower CMC values, and in average, shorter durations, lower peak currents, and shorter distances of propagation. The CMC appears to be the best sprite predictor. The delay between the parent stroke and the sprite allows classifying the events as short delayed ( 20 ms). All long-delayed sprites, i.e., most of the time carrot sprites, are produced by SP + CG strokes with low iCMC values. All SP + CG flashes initiate close to the convective core and generate leaders in opposite directions. Negative leaders finally propagate toward lower altitudes, within the stratiform region that coincides with the projected location of the sprite elements.
Journal of Geophysical Research | 2014
Joan Montanyà; Ferran Fabró; Oscar van der Velde; D. Romero; G. Solà; Juan Ramon Hermoso; Serge Soula; Earle R. Williams; Nicolau Pineda
Electric fields and high-energy radiation of natural lightning measured at close range from a mountaintop tower are discussed. In none of the 12 negative cloud-to-ground upward flashes were X-rays observed. Also no energetic radiation was found in one negative upward leader at close range (20?m). In the first of two consecutive negative cloud-to-ground flashes, X-rays were detected during the last ~1.75?ms of the leader. During the time of energetic radiation in the flash an intense burst of intracloud VHF sources was located by the interferometers. The X-ray production is attributed to the high electric field runaway electron mechanism during leader stepping. Even though the second flash struck closer than the previous one, no X-rays were detected. The absence of energetic radiation is attributed to being outside of the beam of X-ray photons from the leader tip or to the stepping process not allowing sufficiently intense electric fields ahead of the leader tip. High-speed video of downward negative leaders at the time when X-rays are commonly detected on the ground revealed the increase of speed and luminosity of the leader. Both phenomena allow higher electric fields at the leader front favoring energetic radiation. Background radiation was also measured during thunderstorms. The count rate of a particular day is presented and discussed. The increases in the radiation count rate are more coincident with radar reflectivity levels above ~30 dBZ than with the total lightning activity close to the site. The increases of dose are attributed to radon daughter-ion precipitation